SDR SWAA114881Floorbeam · crackedDURING SCHEDULE 14Y CHECK, FOUND LONGITUDINAL FLOORBEAM WEB CRACKED AT BS 639, LBL 45.5. REPAIRED WEB IAW SRM AND ER.SDR KCSA111161Floorbeam · crackedUPPER DECK FLOORBEAM WEB AT STA 400 LBL 58 IS CRACKED.SDR ASOA201101292Floorbeam · corrodedFS 280 FWD FLOORBEAM ANGLE CORRODED. ANGLE CORRODED BEYOND REPAIR, REMOVED ANGLE, DRILLED NEW ANGLE, AND INSTALLED IAW SRM 51-42-06-001-001-A01. MINOR REPAIR.SDR DALA1146640672Floorbeam · corrodedMAIN CABIN FLOORBEAM CORRODED ON TOP SURFACE STA 680 AND FROM LBL 5 TO RBL 24. REMOVED CORROSION, FABRICATED AND INSTALLED REPAIR AT ST AEROSPACE SAN ANTONIO DURING HMV.SDR CALA2011070700461Floorbeam · corrodedAFT WET AREA FLOORBEAM UPPER SURFACE HAS CORROSION AT STA 1640 BL 0 - RBL 9.20 APPROX. REPAIRED CORRODED UPPER SURFACE OF FLOORBEAM AT STA 1640 AND BL-0 TO RBL 9.20 REF SRM 53-00-51 REPAIR 3.SDR SWAA114868Floorbeam · corrodedDURING SCHEDULED 20Y CHECK, FOUND FLOORBEAM UPPER FLANGE CORRODED AT BS 986.5, LBL 43. REPAIRED FLANGE PER SRM.SDR SWAA114846Floorbeam · crackedDURING SCHEDULED 26Y CHECK, FOUND CENTER WING BOX LONGITUDINAL FLOORBEAM LOWER CHORD CRACKED AT BS 663, LBL 24.8. REPAIRED CHORD PER EA.SDR R61A20110170Floorbeam · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND RT AFT FLOORBEAM FROM FR86-90 HAS CORROSION. MX REMOVED AND REPLACED RT AFT FLOOR BEAM FROM FR 86-90 IAW EMB 170 SRM 51-40-02, 51-40-01,51-43-02. FCS NOT AFFECTED. P/N 170-65669-004 A/C REMAINS IN CMH FOR HEAVY CHECK CSDR DALA1147280672Floorbeam · corrodedALL NUT PLATE STRIPS ATTACHED TO FWD SIDE OF 1681 FLOORBEAM HAVE CORROSION (14EA). REMOVED CORROSION AND REPAIRED DURING HMV.SDR DALA1146790672Floorbeam · corrodedMAIN CABIN FLOOR BEAM HAS CORROSION ON UPPER SURFACE AT STA 365 AND APPROX RBL 60. REMOVED CORROSION AND INSTALLED REPAIR DURING HMV.SDR ASOA201101401Floorbeam · corrodedCORROSION DAMAGE EXCEEDS GENERAL ALLOWABLE DAMAGE LIMITS OF SRM 53-00-00-101-001-A01, REMOVED FS 280 BEAM WL 72 IAW SRM 51-42-06-001-001-A01, 51-42-13-001-001-A01, 51-42-21-001-001-A01, 51-42-22-001-001-A01. CUT CROSSBEAM IAW REO 670-53-11-047. NDI IAW REOSDR IPXA11168199Floorbeam · bentINSPECTION TYPE:10YR, MAIN CABIN ABOVE WING BOX FLOOR SUPPORT AT FR47 UNDER FLOOR PANEL 241ZT IS BENT. ACCOMPLISHED REPAIR ON MAIN CABIN FLOOR SUPPORT AT FR 47 Y450-Y953 IAW EO A300-5310-43553-A, PARA 6A.SDR FDEA201107052591Floor Support · misrepairedREPAIR AT FR14-15A Y-1959 MAIN DECK FLOOR STRUCTURE SUPPORT FLANGE FOUND TO NOT BE IAW APPROVED DOCUMENTATION.SDR FDEA201107052582Crossbeam · misrepairedFR38.2 FWD CARGO BAY Y-970 CROSSBEAM SPLICE REPAIR FOUND TO NOT CONFORM TO SRM. REPLACED IAW SRM 53-10-15 FIG 207.SDR FDEA201107052581Crossbeam · misrepairedFR38.2, Y450 FWD CARGO BAY CROSSBEAM SPLICE REPAIR FOUND TO NOT COMPLY TO SRM. REPLACED IAW SRM 53-10-15 FIG 207.SDR FDEA201107052580Crossbeam · misrepairedFR38.2 Y-360 FWD CARGO BAY CROSSBEAM FLANGE SPLICE REPAIR FOUND TO NOT COMPLY WITH SRM. REPLACED IAW SRM 53-10-15 FIG 207.SDR FDEA201107052577Crossbeam · misrepairedFR60-61 Y450 CROSSBEAM SPLICE REPAIR DOES NOT COMPLY WITH SRM 53-10-15. REPLACED IAW SRM 53-10-15 FIG 207SDR FDEA201107052576Crossbeam · misrepairedFR60-61 Y-500 CROSSBEAM SPLICE REPAIR DOES NOT COMPLY WITH SRM 53-10-15. REPLACE IAW SRM 53-10-15 FIG 207SDR UALA2011070603340Floorbeam · corrodedFLOORBEAM AT STA 1660 HAS CORROSION APPROXIMATELY 12 INCHES LEFT AND RIGHT OF BL ON TOP SIDE. MAJOR REPAIR ACCOMPLISHED: RMV'D PREVIOUS REPAIR, FABBED AND INSTALLED T-CHORD, ANGLES AND STRAPS STA 1660, LBL 10 - RBL 02 PER SRM ON PEMCO NR 2808N00106.SDR UALA2011070603339Floorbeam · corrodedCORROSION ON FLOORBEAM AT BS 365.25 RBL 0 - RBL 58 MAIN CABIN (N-R 2775N00239). MAJOR REPAIR ACCOMPLISHED: FABBED T-CHORD, STRAPS, ANGLES, SHIMS AND INTERCOSTALS. INSTALLED T-CHORD, ANGLES AND STRAPS STA 365, RBL 0 - RBL 58. INSTALLED INTERCOSTALS STA 345 SDR FDEA201107052586Floorbeam · corrodedCTR CARGO COMPT BS 1781 FLOORBEAM UPPER CHORD AFT FLANGE LOWER SURFACE CORRODED RBL 26-31. REMOVED FLOORBEAM AND ROLLER TRAYS TO GAIN ACCESS TO DAMAGED AREAS IAW SRM 57-31-01 VII. CLEANED UP CORROSION AND FOUND OUT OF LIMITS IAW SRM 51-21-01 VII. AND 53-00-01SDR ASOA201101286Floorbeam · crackedFS 484 OTBD, RBL27 FLOOR SUPPORT ANGLE CRACKED PREVIOUS REPAIRED ANGLE MK7236. R & R FLOOR SUPPORT ANGLE IAW SRM 51-40-11, 51-42-21. THIS IS A MINOR REPAIR.SDR ASOA201101285Floorbeam · corrodedFLOOR SUPPORT AT FS 349.00 LT SIDE UNDER PANEL 231CLF CORRODED. CLEAN CORROSION IAW 51-21-06 AND VERIFY LIMITS. REMOVED CORROSION FROM FS 349 CROSSBEAM AT LBL 40, WL 73, TOP FLANGE IAW SRM 51-21-06. REPAIR DIMENSIONS: 1"X 1.5" X .003" DEEP ORIGINAL THICKNESSDR DALA1142496803Floorbeam · corrodedFUSELAGE STATION 1640 FLOORBEAM CORRODED MULTIPLE AREAS PSV 11 NR CARDS 44, 216, 217, 218.SDR SWAA114785Web · corrodedDURING SCHEDULED 20Y CHECK, FOUND WEB CORRODED BETWEEN BS 767 TO BS 787, STR 17L. REMOVED AND REPLACED WEB PER SRM AND DWG.SDR SWAA114777Channel · corrodedDURING SCHEDULED 20Y CHECK, FOUND AFT CARGO COMPARTMENT CHANNEL CORRODED AT BS 767+6, RBL 3.0. REPAIRED CHANNEL PER SRM AND EA.SDR DALA1142266803Floorbeam · corrodedFUSELAGE STATION 365 FLOORBEAM CORROSION APPROX B/L 0 THROUGH THE R1 DOOR.SDR COMA2011070590010Floorbeam · corrodedFS 280 FLOORBEAM UPPER FLANGE CORRODED FROM LBL 9 - RBL 9. REMOVED AND REPLACED FS 280 CROSS BEAM AS PER BOMBARDIER DRAWING CC670-34010 REV J, AND IAW SRM 51-42-06, SRM 51-42-21, SRM 51-42-27 AND REO 690-53-11-032.SDR UALA2011070503306Floorbeam · corrodedCORROSION ON FLOORBEAM AT BS 1640 FROM LBL 5 -RBL 58. (N-R 775N00395) MAJOR REPAIR ACCOMPLISHED: REMOVED OLD REPAIR, FABBED AND INSTALLED T-CHORD AT STA 1640, LBL 5 - RBL 58 PER SRM ON PEMCO NR 2775N00395.SDR UALA2011070503305Floorbeam · damagedFLOORBEAM AT BS 660 HAS TOOLING MARK AT RBL 37-41.5 (N-R 2775N00559). MAJOR REPAIR ACCOMPLISHED: FABBED AND INSTALLED SUPPORT BEAM, ANGLES AND STRAPS AT STA 660, RBL 35 - 51 PER SRM.SDR ASOA201101266Floorbeam · crackedFS 280 INBD & OTBD CLIPS ARE CRACKED AT LBL 9 AND RBL 9. THIS REPAIR IS CLASSIFIED AS A MINOR REPAIR IAW ASA SOP 5702. (CLOSED)SDR FDEA201107032558Floorbeam · damagedBULK CARGO COMPARTMENT, FR 63 FLOORBEAM BOTTOM CEILING PANEL ATTACHMENT BETWEEN SEAT TRACK 1 AND 2L HAS A DRILL START. COMPLIED WITH EA 6-5310-145342 PT1.SDR FDEA201107012528Floorbeam · corrodedSTA 345, FLOORBEAM, RBL 60 CORRODED AND PREVIOUS BLEND ON UPPER FLANGE. REMOVED DAMAGED AREA FROM UPPER FRAME STA 345 RBL 52- RBL 70 IAW SRM 51-10-02 AND SRM 53-00-51 FIG 201. DRILLED AND LOCATED HOLES FOR REPAIR IAW SRM 51-40-05. DRILLED AND LOCATED REPAISDR UALA2011070103259Floorbeam · corrodedCORROSION ON LOWER PART FLOORBEAM AT BS 345 RBL 58 RBL 12 (N-R 2775N00237). MAJOR REPAIR ACCOMPLISHED: REMOVED AND REPLACED STA 345 FLOORBEAM RBL 8 - RBL 60 USING BAC 1505-100880 7075-T6 IAW B757 SRM. REPAIR ANGLES FROM PO 1061690. INSTALLED REPAIR PER B75SDR EIAA2011076Floorbeam · brokenTOP FLANGE OF AFT PIT FLOOR BEAM IS BROKEN BS 1820 7.5 INCHES I/B OF DOOR THRESHOLD. REMOVED DAMAGED AREA, FABBED AND INSTALLED REPAIR PER B747 SRM 51-40-04 FIG 2.SDR SWAA114738Floorbeam · crackedDURING SCHEDULED 16Y CHECK, FOUND FLOORBEAM CRACKED AT BS 328, LBL 30. REMOVED AND REPLACED BEAM PER SRM.SDR SWAA114737Floorbeam · crackedDURING SCHEDULED 20Y CHECK, FOUND UPPER HORIZONTAL FLANGE FLOORBEAM CRACKED AT 294.5, LBL 54. REPAIRED BEAM IAW SRM AND DWG.SDR EIAA2011075Floorbeam · damagedUPPER DECK FLOORBEAM BS 340 RBL 62.75 1 HOLE HAS SHORT EDGE DISTANCE. TRIMMED OUT AREA, FABBED AND INSTALLED REPAIR PER ECRA 488-53-038-2.SDR SWAA114716Floorbeam · corrodedDURING SCHEDULED 12Y CHECK, FOUND FLOORBEAM CORRODED AT BS 967, RBL 5. REPAIRED BEAM PER SRM.SDR SWAA114697Floorbeam · crackedDURING SCHEDULED 18Y CHECK, FOUND LONGITUDINAL FLOORBEAM WEB CRACKED AT BS 639, LBL 45. REPAIRED WEB PER EA AND ER.SDR AALA20120613014Floorbeam · corrodedFLOORBEAM UPPER FLANGE CORROSION AT STATIONS 324 TO 339. REMOVED AND REPLACED FLOORBEAM CHORD CREASE ANGLE FROM STATIONS 259 TO 360 AT RIGHT NUMBER 1 DOOR PER AARD 53-00-00-7 AND EA B737-53-024412.SDR UALA2011062903218Strap · brokenON POST FLT WALK AROUND SCRATCHES ON SIDE OF FUSELAGE LEFT SIDE 10' FWD OF DOOR 2L AT FLOOR LEVEL. ALSO IN NLG TUNNEL FOUND 2 FLOORBEAM STRAPS BROKEN BEAM 365-25 & 377.7. BLENDED SCRATCHES.SDR FDEA201106292497Floorbeam · gougedSTA 950 FLOORBEAM TOP STRAP GOUGED, LBL 50. CUTOUT DAMAGED AREA OF BS 950 FLOORBEAM UPPER STRUCTURE, FABRICATED, AND INSTALLED REPAIR PARTS IAW SRM 53-10-8 FIG 11.SDR FDEA201106292495Floorbeam · corrodedMAIN CABIN, FLOORBEAM UPPER SURFACE HAS EXFOLIATION CORROSION AT BS 950, BTW LBL 24.75 AND LBL 45.50. REMOVED TEE SECTION OF FLOORBEAM IAW SRM 51-30-2. FABRICATED, LOCATED, AND DRILLED NEW TEE SECTION IAW SRM 51-30-5. INSTALLED TEE SECTION IAW SRM 51-30-2 SDR A6WA201140721Floorbeam · crackedCLIPS ARE CRACKED AT RBL 9.0, OTBD AND INBD, LBL 9.0 INBD. R & R CLIPS RBL 9.0 OTBD AND INBD AND LBL 9.0 INBD IAW SRM 51-42-06 AND REO 601R-53-21-064, REV NC.SDR FDEA201106282482Floorbeam · damagedFWD LAV AREA FLOORBEAM STA 348, RBL 12 UNDERSIDE OF TOP TEE ANGLE, REPAIR HAS MISSED DRILLED FASTENER HOLE ALONG BACKSIDE EDGE AND INTO VERTICAL FILLER. FABRICATED REPAIR ANGLE SPLICES, CUTOUT DAMAGED OF TOP TEE, FABRICATED TOP TEE, INSTALLED NEW SECTION OFSDR SWIA201126646Floorbeam · crackedFS 280 FLOORBEAM FLANGE CRACKED. (C-CHECK) REPAIR PER REO.SDR SWAA114628Floorbeam · corrodedDURING SCHEDULED 14Y CHECK FOUND, FLOORBEAM UPPER FLANGE CHORD CORRODED AT BS 986, RBL 44. REPAIRED BEAM PER EA AND ER.SDR SWAA114621Floorbeam · corrodedDURING SCHEDULED 16Y CHECK FOUND, FLOORBEAM CORRODED AT BS 967, RBL 4. REPAIRED BEAM PER SRM.SDR USAA2011071900019Floorbeam · corroded2S CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR64 TO FR66, Y254. REPLACED FLOORBEAM BETWEEN FR64 TO FR66, Y254 IAW A319 SRM 51-72-11.
Back to JASC 5315