JASC 5315
Service difficulty reports · 44,220
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010110504120Floorbeam · corrodedCORROSION ON FLOORBEAM AT STA 1660, RBL 0 -15, AND MATERIAL REMAINING AFTER CORROSION BLEND OUT EXCEEDS LIMITS OF SRM. MAJOR REPAIR ACCOMPLISHED: REMOVED DAMAGED AREA AT UPPER FLANGE AND FABRICATED AND INSTALLED ANGLE DOUBLERS AND STRAPS.SDR QXEA2010110500712Floorbeam · corrodedC3 CHECK - AVIONICS BAY FLOOR SUPPORT ANGLE ATTACHED TO FS 280 IS CORRODED. REMOVED SUPPORT ANGLE IAW SRM 51-42-06-001-001-A01. LOCATED FASTENER HOLES IN NEW ANGLE IAW SRM 51-40-11-001-001-A01. INSTALLED NEW ANGLE IAW SRM 51-42-06-001-001-A01. TOPCOATED ISDR AALA20101105TUL13Floorbeam · corrodedT-CAP CORRODED STATION 740 RIGHT BUTTLINE 53. ACCOMPLISHED SPLICE REPAIR PER SRM 53-00-51-2R 3.SDR AALA20101105TUL08Floorbeam · corrodedCORROSION STATION 680 LEFT BUTTLINE 14. ACCOMPLISHED SPLICE REPAIR PER SRM 53-00-51-2R.SDR AALA20101105TUL01Support · corrodedCORROSION ON FLOORBEAM SUPPORT AT STATION 683 RIGHT BUTTLINES 24 TO 48. REPLACED FLOORBEAM SUPPORT PER SRM 51-10-02.SDR DALAFAR145SDR103Floorbeam · corrodedFOUND CORROSION ON FLOORBEAM UPPER CAP AT FS 325 RBL 30 TO RBL 51. CONDITION FOUND DURING FLOOR COVERING REPLACEMENT. REF DAL NON-ROUTINE CARD 336. REPAIRED PER SRM 53-00-51 FIG 201. CLASSIFIED AS LEVEL 2 CORROSION.SDR FDEA201011054259Floorbeam · corrodedBS 365, FLOORBEAM HAS CORROSION ON UPPER SURFACE FROM BL 0.0 TO RBL 65.0. AREA OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DETAIL III. ORIG MAT .125. AFTER REWORK .095 AREA OF DAMAGE L(.5") X W(2"). R & R UPPER T-CHORD IAW SRM 53-00-51. REPAIR NR3 FROM LBLSDR FDEA201011054258Floorbeam · corrodedBS 345 FLOORBEAM HAS CORROSION ON UPPER SURFACE AT RBL 2.0. AREA OUT OF LIMITS IAW SRM 53-00-51, FIG 101. AFTER REWORK .101, AREA OF DAMAGE L(2.5") X W(2"). R & R UPPER T-CHORD IAW SRM 53-00-51, REPAIR 3, FROM RBL 35 LBL 50. BS 345. CATEGORY "A" REPAIR. MAJOSDR DALA1031315523Floorbeam · corrodedDURING L-CHECK FOUND CORROSION ON MAIN CABIN FLOORBEAM AT BS 1661 LBL 58. REPAIRED PER SRM 53-00-51 PAGE 101 TO PAGE 103, SRM 53-10-51 PAGE 6, DWG BAC1518-338 REV C, SRM 51-40-02 PAGE 1-10, SRM 53-00-51.SDR AALA20101104TUL15Floorbeam · corrodedCORROSION STATION 363 LEFT BUTTLINE 12 TO RIGHT BUTTLINE 53. REPLACED T-CAP PER SRM 53-00-51-2R 3.SDR QXEA2010110500707Floorbeam · crackedC3 CHECK - 280 BEAM IS CRACKED ON LT AND RT SIDE. PERFORMED CUTLINE ON NEW BEAM IAW REO 670-53-11-047. REMOVED LT AND RT 280 DRIP PANS AND INTERCOSTALS IAW SRM 51-42-21-001-001-A01. FOUND COCKPIT FLOOR ANGLE OF FS 280 CRACKED. PERFORMED LPI ON CUTLINE NO SDR REXA201000246Floorbeam · corrodedLBL 27.00 FLOORBEAM TOP CAP IS CORRODED FROM FS 589.00 TO FS 621.00. BLENDED CORROSION ON FLOOR SUPPORT CAP AND FITTING, FOUND TO BE OUT OF SERVICEABLE LIMITS IAW CRJ-200 SRM 53-61-43 AND 53-00-00 FIG 101. REMOVED AND INSTALLED NEW SERVICEABLE FLOOR SUPPORT SDR AALA20101103TUL10Floorbeam · corrodedCORROSION STATION 1640 RIGHT BUTTLINE 6 TO LEFT BUTTLINE 39. REPLACED T-CAP FLOOR SUPPORT BEAM PER SRM 53-00-51-2R 3.SDR ASOA201001720Floorbeam · corrodedFLOORBEAM CAP AT LBL 9 FS 605 IS CORRODED. REPAIRED FLOORBEAM.SDR FDEA201011034241Floorbeam · corrodedCABIN, FLOORBEAM AT STA 377.7, LBL 5.3 TO LBL 7 HAS EXISTING CORROSION BLEND THAT REQUIRES FURTHER CORROSION BLENDING. REPAIR CARRIED OUT IAW EA F-5310-142343 - BS 377 FLOORBEAM CORROSION REPAIR AT LBL 6 TO LBL 52. REPAIR IS CLASSIFIED AS MAJOR IAW GMM 6-2-SDR FOTR2016911134Floorbeam · corrodedAFT CARGO CABIN FLOORBEAM AT STA. 1309 IS CORRODED AT RBL 20. REPAIRED ON NR 11134 FASI WO 20169.SDR FOTR2016911132Floorbeam · corrodedAFT CARGO COMPARTMENT, BS. 1309 CABIN FLOORBEAM IS CORRODED ON BOTTOM SURFACE LBL.16 TO RBL.16. REPAIRED ON NR 11132 FASI W/O 20169.SDR DALA1052610909Floorbeam · corrodedMAIN PASSENGER CABIN FLOOR SUPPORT AT FS 200 HAS CORROSION FROM RBL 9 TO RBL 47, BEYOND LIMITS. REPAIRED IAW SRM 51-30-2 AND 53-14-1, FIG 11.SDR ASOA201001717Floorbeam · corrodedFROM LEFT TO RIGHT AT FS 280 FOUND HEAVY CORROSION ON TOP OF BEAM. REMOVED AND REPLACED BEAM AT FS 280 IAW SRM`S 51-40-06, 51-41-02, 51-42-06, 51-42-15, 51-42-28, 51-42-02, 51-40-11, 51-23-00, 51-21-11, & 51-21-16.SDR ASOA201001714Crossbeam · corrodedFS 280 CROSSBEAM CORRODED IN SEVERAL PLACES. INSTALLED TEE BRACKETS AND COMPLIED WITH STEPS 9 TO 17 OF REO 670-53-11-047. ALL WORK DONE IAW REO 670-53-11-047. COMPLIED WITH EC/TC REO 670-53-11-047 AND REO 670-53-11-047, REV E.SDR R61A20100519Floorbeam · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON FLOORBEAM O/B OF RIGHT LONG BEAM AT FRAME 14. MAINTENANCE REMOVED AND REPLACED FLOORBEAM AT FRAME 14 IAW EMB 170 SRM 51-41-02, 51-43-01, 51-40-02 & 51-41-01. A/C IS CURRENTLY STILL OUT OF SDR SWAA106764Floorbeam · corrodedDURING SCHEDULED 16Y CHECK, FOUND BEAM CHORD CORRODED AT BS 986.5, BETWEEN RBL 13 TO RBL 45. REPAIRED CHORD PER TI.SDR GTIA1000128Floorbeam · corrodedUPPER FUSELAGE PAX CABIN AFT SERVICE AREA STA 2884 BETWEEN -Y 800 AND -Y 1020 FLOOR SUPPORT STRAP WITH CORROSION. REPLACED FLOOR SUPPORT STRAP ON STA 2884 BETWEEN -Y 800 AND -Y 1020 IAW A319 SRM 51-72-11 PAR 4 AND 6.SDR DALA1030695523Floorbeam · corrodedDURING L-CHECK FOUND CORROSION ON MAIN CABIN FLOORBEAM FLANGE. REPAIRED PER SRM 53-00-51 PAGE 201-204 FIGURE 201.SDR SWAA106730Floorbeam · corrodedDURING SCHEDULED 16Y CHECK, FOUND FLOORBEAM CORRODED AT BS 328, LBL 28. REPAIRED BEAM PER SRM.SDR USAA2010110592521Floorbeam · corrodedMCN - C2 - MAJOR REPAIR - CORROSION ON FLOORBEAM UPPER SURFACE AT BS 1518, RBL 17. REPAIRED FLOORBEAM UPPER CHORD AT BS 1518, RBL 17 IAW B767 SRM 53-00-51.SDR USAA2010113092687Floorbeam · corrodedCWF - C2 - MAJOR REPAIR - INTERGRAINULAR CORROSION ON FLOOR AUXILLARY BEAM AT FR75A BETWEEN -Y450 TO -Y794.3. REPLACED FLOOR AUXILLARY BEAM AT FR75A BETWEEN -Y450 TO -Y794.3 IAW A330 SRM 57-72-11 & 51-42-11.SDR DALA1032376902Angle · corrodedUPON REMOVAL OF FLOOR SUPPORT CHANNEL AT STA 717 LBL 19 WHILE WORKING N/R 182637 FOUND CORROSION AT MATING SURFACE OF HORIZ FLANGE LWR SURFACE EXISTING REPAIR ANGLE ON FLOORBEAM. REMOVED AND REPLACED REPAIR ANGLES AND FILLER REF SRM 53-00-51 REPAIR 5 PG 201 FSDR DALA1031949853Support · crackedDURING M-CHECK FOUND FORWARD CARGO COMPT STA 408 ABOVE DOOR OPENING FLOORBEAM SUPPORT IS CRACKED. REMOVED CRACKED SUPPORT, OBTAINED NEW SUPPORT PO 0307W016 PN 9957907-3, DRILLED AND DEBURRED AND INSTALLED IAW DC-9 SRM 51-30-5 & 51-10-4SDR FOTR2016911059Floorbeam · corrodedFLOORBEAM SUPPORT ANGLES CORRODED STA 148- 200 BETWEEN LBL 60 AND RBL 60. REPAIRED ON NR 11059 FASI W/O 20169.SDR COEA2010102866803Floorbeam · damagedHEAVY CHECK COE / MAJOR REPAIR: FLOORBEAM 38 MISDRILLED: FABRICATED AND INSTALLED REPLACEMENT FLOORBEAM PER ATR STRUCTURAL REPAIR MANUAL.SDR USAA2010112392647Floorbeam · corrodedCWF - C2 - MAJOR REPAIR - CORROSION ON FLOORBEAM ASSEMBLY BETWEEN FR75A TO FR76, -Y1448. REPLACED FLOORBEAM ASSEMBLY BETWEEN FR75A TO FR76, -Y1448 IAW A330 SRM 51-42-11 & 51-41-14.SDR FDEA201010284187Floorbeam · dentedMAIN CARGO COMPARTMENT FLOORBEAM HAS DENT BS 310.5. DENTS ON FLOOR BEAM STA 310.5 NOT PERMITTED IAW SRM 53-00-51 FIG 101. REMOVED AND REPLACED FLOORBEAM IAW SRM 51-40-02. CLASSIFIED CAT "A" MAJOR REPAIRSDR ASOA201001687Floorbeam · corrodedTEE ANGLES AT 280 RBL9 & LBL9 FWD FLOORBEAM TO 280 ATTACHED ANGLES CORRODED. REMOVED UNSERVICEABLE TEE ANGLES AND REPLACED WITH SERVICEABLE TEE ANGLES. ALL WORK DONE IAW SRM 51-42-21-001-001-A01 AND SRM 51-42-22-001-001-A01.SDR ASOA201001686Floorbeam · crackedSUPPORT ANGLE FOR RT WEB AT FS 280, RBL26 FOUND CRACKED. R & R SUPPORT ANGLE FOR RT WEB AT FS280, RBL 26 IAW SRM 51-40-11-001-001-A01 AND 51-42-06-001-001-A01. (CLOSED)SDR UALA2010102904004Floorbeam · corrodedCORROSION IN FLOOR CHANNEL IN FWD GALLEY AREA AT STATION 330 FROM RBL 0 TO 40. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION FROM AREA AND FOUND TO BE BEYOND LIMITS IAW THE SRM AFTER BLENDING. REMOVED FLOOR CHANNEL AND INTERCOSTALS AND FABRICATED & INSTALLED RESDR UALA2010102803994Floorbeam · corrodedFLOORBEAM CORRODED ON UNDERSIDE, APPROX STA 1681, RBL 32. MAJOR REPAIR ACCOMPLISHED: MATERIAL REMAINING AFTER BLENDOUT EXCEEDS LIMITS OF SRM. TRIMMED OUT DAMAGED SECTION OF T-CAP AT BS 1681 FLOORBEAM FROM RBL 32 TO CUSP, FABRICATED 2 REPLACEMENT STRAPS AND ONESDR UALA2010102904002Floorbeam · damagedFWD GALLEY FLOOR AREA, FLOORBEAM STRUCTURE AT STA 366.25 RBL 0 TO 65 HAS DAMAGE. MAJOR REPAIR ACCOMPLISHED: MATERIAL REMAINING AFTER BLENDOUT EXCEEDS LIMITS OF SRM. REMOVED 34" DAMAGED AREA AND REPLACED WITH FABRICATED NEW FLOORBEAM IAW SRMS.SDR FDEA201010284189Floorbeam · corrodedBS 324 FLOORBEAM HAS SEVERAL AREAS OF CORROSION ON UPPER SURFACE BETWEEEN BL 0 AND RBL 40. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101. ORIG MATERIAL .125 AFTER REWORK .085. R & R UPPER CHORD RBL 62 TO LBL 62 IAW SRM 51-40-02. CLASSIFIED CATEGORY "ASDR U2RA227DHN033Floorbeam · corrodedMAIN CABIN STA 365 FLOORBEAM HAS CORROSION SEVERAL PLACES RBL 31 TO RBL 64.SDR V0XR413Y102710006Floorbeam · corroded280 BEAM HAD EXFOLIATION CORROSION ACROSS TOP. R & R 280 BEAM IAW REO 670-53-11-047.SDR SWAA106659Floorbeam · corrodedDURING SCHEDULED 16Y CHECK, FOUND FLOORBEAM CORRODED AT BS 294.5, RBL 8. REPAIRED BEAM PER SRM.SDR ASOA201001667Floorbeam · corrodedFLOORBEAM CAP AT LBL 9, FS 605 IS CORRODED. REMOVED CORROSION FROM FLOORBEAM CAP. DEEPEST MATERIAL LOSS AT 0.012 DEEP X 0.75" W X 0.50" L AND FOUND TO BE OUT OF LIMITS IAW SRM 51-21-06, 53-00-00, 53-61-43. REMOVED FLOORBEAM CAP BETWEEN FS 570 AND FS 621 IAW SSDR ASOA201001665Floor Support · corrodedFLOORBEAM CAP AT LBL 27 FROM FS 621 TO 574 IS CORRODED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 51-21-06 AND 53-00-00. LOCATED AND DRILLED IAW SRM 51-42-06, 51-42-21 AND REO 601R-53-61-3778.SDR ASOA201001661Floorbeam · crackedFS 280, LBL 9, OTBD FLOOR SUPPORT CLIP CRACKED. FLOOR SUPPORT CLIP REPLACED ON MWC 8747421 OP 356.SDR ASOA201001660Floorbeam · crackedFS 280, LBL 9, INBD FLOOR SUPPORT CLIP CRACKED. FLOOR SUPPORT CLIP REPLACED ON MWC 8747421 OP 356.SDR ASOA201001659Floorbeam · crackedFS 280, RBL 9 INBD FLOOR SUPPORT CLIP CRACKED. REPLACED ON MWC 8747421 OP 356.SDR ASOA201001658Floorbeam · crackedFS 280, RBL 9, OTBD FLOOR SUPPORT ANGLE CRACKED. FLOOR ANGLE REPLACED ON MWC 8747421.SDR FOTR201728861Floorbeam · damagedSTA 360 FLOORBEAM FASTENER HOLE ELONGATED RBL.55. REPAIRED ON NR 8861 FASI W/O 20172.SDR FOTR201728871Floorbeam · corrodedMAIN CABIN FLOORBEAM AT STA 1130 LBL 24 IS CORRODED. REPAIRED ON NR 8871 W/O 20172
Back to JASC 5315