SDR C2XA03SH163Floorbeam · corrodedDURING C-CHECK THE CENTER FLOORBEAM WAS FOUND TO HAVE CORROSION BETWEEN FRAMES 24 AND 25. MAINTENANCE REMOVED DAMAGE AND REPAIRED AFFECTED BEAM IAW EMB 145 SRM 53-22-10. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.SDR SWIA200312085Floorbeam · crackedFS 280 RBL 9.0 FLOORBEAM I/B AND O/B ANGLES CRACKED. DISCOVERED DURING C-CHECK. ANGLES REPLACED IAW CRJ SRM 51-40-11, 51-42-06, 51-42-21, 51-23-00. P/N: 601R31113-58.SDR C2XA03SH162Floorbeam · corrodedSHV DURING C-CHECK THE LEFT HAND FLOORBEAM WAS FOUND TO HAVE CORROSION AT RAMP SUPPORT ANGLE BETWEEN FRAMES 19 AND 20. MAINTENANCE REMOVED DAMAGE AND PERFORMED A DOUBLER REPAIR ON AFFECTED BEAM IAW EMB 145 SRM 53-21-10. THE AIRCRAFT WAS APPROVED TO RETURN TSDR C2XA03SH161Floorbeam · corrodedSHV-DURING C-CHECK THE LEFT HAND FLOORBEAM HAS CORROSION UNDER THE COMPOSITE CROSSBEAM BETWEEN FRAMES 24 AND 25. MAINTENANCE REMOVED DAMAGE AND REPAIRED AFFECTED BEAM IAW EMB 145 SRM 53-21-10. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.SDR DHL2003604735Floorbeam · corrodedAFT ACCY COMPT FLOORBEAM CORRODED, STA 1640.000, LBL-5 (MAJOR REPAIR). PERFORMED MAJOR REPAIR IAW SRM 53-2-0 FIG 1G, TR 53-124. REMOVED CORROSION IAW SRM 51-1-8 PG 17-18. FOUND OUT OF LIMITS IAW SRM 53-2-0 PG 2P. CLEANED, TREATED AND PRIMED AREA IAW SRM 51SDR GTIA030409Floorbeam · brokenFOUND FS 655 CABIN FLOORBEAM BROKEN OFF AT RIVETS. DRILLED EXISTING HOLES. INSTALLED FLOOR PANEL SUPPORT. (M)SDR C2XA03SH159Floorbeam · corrodedSHV- DURING C-CHECK THE CENTER FLOORBEAM BETWEEN FRAMES 16 AND 23 WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BEAM IAW EMB 145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA03SH151Floorbeam · corrodedSHV-DURING C-CHECK THE SUPPORT RAMP ON THE CENTER FLOORBEAM BETWEEN FRAMES 18 AND 20 WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFFECT SUPPORT IAW EMB 145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA200316005Floorbeam · corrodedDURING AN MBV, THE CENTER FLOORBEAM LOWER FLANGE WAS FOUND TO BE CORRODED BEYOND SRM LIMITS BETWEEN FRAME 26 AND 27. BLENDED THE DAMAGED AREA TO REMOVE ALL CORROSION. PERFORMED AN EDDY CURRENT INSPECTION OF THE BLENDED AREA WITH NO DEFECTS NOTED. FABRICATEDSDR SIMA200316003Floorbeam · corrodedABI - DURING AN MBV, THE CENTER FLOORBEAM LOEWR FLANGE WAS FOUND TO BE CORRODED BEYOND SRM LIMITS BETWEEN FRAME 24 AND 25. BLENDED THE DAMGED AREA TO REMOVE ALL CORROSION. PERFORMED AN EDDY CURRENT INSPECTION OF THE BLENDED AREA WITH NO DEFECTS NOTED. FABRICSDR C2XA03SH148Floorbeam · corrodedDURING C-CHECK THE DOUBLER ON THE RIGHT HAND FLOORBEAM AT FRAME 22 WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED DOUBLER IAW EMB 145 SRM 53-21-10. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA200314801Floorbeam · corrodedABI - DURING AN IMBV INSPECTION, THE LEFT FLOORBEAM AT FRAME 20 WAS FOUND TO BE CORRODED BELOW SRM LIMITS. CUTOUT DAMAGE SECTION OF LEFT FLOORBEAM, CLEANED AND TREATED THE REPAIR AREA. FABRICATED AND 18 INCH BY 2 INCH EXTERNAL ANGLE, 10 INCH BY 2 INCH FILLERSDR USAA030089Floorbeam · corrodedPIT - FOUND FLOORBEAM CORRODED APPROX 6 INCHES BY 1 INCH, FLOORBEAM BETWEEN STATION 344 AND 360 10 INCHES LBBL. MANUFACTURED AND INSTALLED T-CAP PER EA 76223 SRM CHAPTER 51. (M)SDR SWAA031152Floorbeam · crackedDURING SCHEDULED 1/2D CHECK, FOUND CABIN FLOORBEAM CRACKED, BS 947.5, LBL 53. REPAIRED FLOORBEAM PER SWA EA.SDR SWIA200312027Floorbeam · crackedFS 280 FLOORBEAM LEFT OUTBOARD ATTACH ANGLE LBL 9.0 CRACKED. FOUND DURING C-CHECK INSPECTION. REPLACE ANGLE IAW CRJ SRM 51-40-11. P/N: 601R31113-57SDR 03FDEA00787Floorbeam · corrodedCORROSION ON FLOORBEAM AT STA 312 APPROX RBL 18 AT WL 208.1 IN LAVATORY AREA. REMOVED, FABRICATED REPAIR PARTS AND INSTALLED IAW BOEING DRAWING 65-17593 AND BOEING 727-100 SRM 51-40-4 AND 51-30-2SDR C2XA03TY075Floorbeam · corrodedDURING A SCHEDULED INSPECTION THE CENTER FLOORBEAM AT FRAME 20 WAS FOUND TO BE CORRODED IN SEVERAL AREAS. MAINTENANCE ACCOMPLISHED A DOUBLER REPAIR IAW EMB SRM 53-21-10 AND 51-21-04,05, THE REPAIR WAS SATISFACTORY. THE AIRCRAFT WILL BE RELEASED FOR SERVICE USDR AALA20030606Floorbeam · corrodedFLOORBEAM AT STATION 303 HAS CORROSION REMOVAL ON UPPER SURFACE AS SHOWN ON SKETCH, BEYOND SRM LIMITS. COMPLETELY RMOVED CORROSION. APPLY ALODINE TO BLENDED AREA. APPLY PRIMER. FILL WITH SEALANT. (M)SDR SWAA031141Floorbeam · crackedDURING SCHEDULED D CHECK, FOUND FLOORBEAM CRACKED AT BS 947, WL 208 AND LBL 53. REPAIRED FLOORBEAM PER BFG ER.SDR ABXA030181Floorbeam · corrodedEXFOLIATED FLOORBEAM IN FORWARD LOWER CARGO, FS 313 AT RIGHT BUTT LINE 6. REPAIRED CORRODED FLOORBEAM IAW DC-9 SRM 53-05.SDR ASAA0310477Floorbeam · corrodedPAE - DURING C-CHECK, FOUND THE LONGITUDINAL BEAM AT FUSELAGE STATION 685, RIGHT BUTTOCK LINE 43 CORRODED. REPAIRED BEAM PER SRM. (M)SDR UPS03440833Floorbeam · corrodedINSPECTION TYPE: C, BULK CARGO STA 2040 LBL 60 - RBL 60 FLOORBEAM STRAP FOUND CORRODED AT UPPER AND LOWER SURFACE. DEFECT TRANSVERSE FLOORBEAM REMOVED AND SERVICABLE FLOORBEAM REPLACED PER SRM 51-10-01 PG 8, CORROSION BLEND OUT (0.020 INCH X 1 X 4 INCH).SDR AWXA200300664Floorbeam · corrodedLCQ - MAJOR REPAIR - DURING C-17 CHECK CORROSION WAS FOUND AT FASTENERS ON FLOORBEAM AT BS 986.5, LBL 25. MAINTENANCE REMOVED CORROSION AND FOUND MATERIAL LOSS TO BE OUT OF LIMITS; REMOVED DAMAGED SECTION OF UPPER TEE AT BS 986.5, LBL 25; FABRICATED A NEW REPSDR C2XA03SH132Floorbeam · corrodedSHV DURING C-CHECK THE RAMP ANGLE ON CENTER OMEGA BEAM BETWEEN FRAMES 19 AND 20 WAS FOUND TO HAVE CORROSION. MAINTENANCE REMOVED DAMAGE AND REPLACED AFFECTED RAMP ANGLE IAW EMB 145 SRM 53-21-10. THE AIRCRAFT WAS APPROVED TO RETURN TO SERVICE.SDR ASOA03216Clip · crackedDURING HANGAR MAINTENANCE IN SHV, THE FLOORBEAM CLIPS AT BULKHEAD FS 280, LBL AND RBL 9 WERE FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE PERFORMED A TEMPORARY REPAIR BY STOP DRILLING THE ENDS OF THE CRACKS OF THE FLOORBEAM CLIPS AT BULKHEAD FS 280, LBL ANDSDR ASOA03215Clip · crackedDURING HANGAR MAINTENANCE, FLOORBEAM CLIPS AT BULKHEAD FS 280 LBL AND RBL 9 WERE FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE PERFORMED A TEMPORARY REPAIR BY STOP DRILLING THE ENDS OF THE CRACKS OF THE FLOORBEAM CLIPS AT BULKHEAD FS 280, LBL AND RBL 9 IAW ASDR ASOA03213Floorbeam · corrodedDURING A C-CHECK IN MCN, THE FLOORBEAM AT FS 280 ENTRY TO THE COCKPIT SECTION WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE IS REMOVING AND REPLACING THE FLOORBEAM AT FS 280 ENTRY TO THE COCKPIT SECTION IAW ASA O600-53-0052. (M)SDR C2XA03TY068Floorbeam · gougedTYS, DURING A SCHEDULED INSPECTION THE CARGO FLOOR LONGITUDINAL BEAM JUST AFT OF LOADING RAMP WAS GOUGED. MAINTENANCE BLENDED THE DAMAGED AREA ON FLOOR SUPPORT AT FR68, FABRICATED AND INSTALLED A DOUBLER, ALODINED, PRIMED AND PAINTED IAW EC5320-01096. THE RESDR C2XA03TY066Floorbeam · corrodedTYS, DURING A SCHEDULED INSPECTION THE OMEGA BEAM BETWEEN FR20 AND 23 WAS FOUND CORRODED IN SEVERAL PLACES. MAINTENANCE CUT OUT THE DAMAGED AREAS, FABRICATED AND INSTALLED ANGLES, SHIMS, FILLER AND PLATE IAW EMB-135/145 SRM 53-21-10. THE REPAIR WAS SATISFACTSDR C2XA03TY064Floorbeam · corrodedTYS, DURING A SCHEDULED INSPECTION THE CARGO DOOR CUTOUT LOWER BEAM WAS FOUND CORRODED. MAINTENANCE REMOVED AND REPLACED THE CARGO DOOR LOWER BEAM IAW EMB-135/145 SRM 51-40-02. THE REPAIR WAS SATISFACTORY AND THE AIRCRAFT WILL BE RELEASED UPON COMPLETION OF SDR C2XA03TY063Floorbeam · corrodedTYS, DURING A SCHEDULED INSPECTION, CORRODED INSERTS AND SURFACE OXIDATION WAS FOUND ON FLOORBEAM, LEFT OUTBOARD AFT IN LAV. MAINTENANCE REMOVED AND REPLACED THE FLOORBEAM IN LAV IAW EMB-135/145 SRM 51-40-02. THE REPAIR WAS SATISFACTORY AND THE AIRCRAFT WILLSDR C2XA03TY061Floorbeam · corrodedTYS, DURING A SCHEDULED INSPECTION THE RIGHT SIDE OF RAMP AT FR20 AND CROSSBEAM WAS FOUND CORRODED. MAINTENANCE REMOVED AND REPLACED THE CENTER RAMP ANGLE IAW EMB-135/145 SRM 51-40-02. THE REPAIR WAS SATISFACTORY AND THE AIRCRAFT WILL BE RELEASED UPON COMPLESDR C2XA03TY060Floorbeam · corrodedTYS, DURING A SCHEDULED INSPECTION THE DIGITAL PLATE AT FR20 & 22 WAS FOUND CORRODED IN SEVERAL PLACES. MAINTENANCE REMOVED AND REPLACED THE DIGITAL PLATE IAW EMB-135/145 SRM 51-40-02. THE REPAIR WAS SATISFACTORY AND THE AIRCRAFT WILL BE RELEASED UPON COMPLESDR C2XA03TY059Floorbeam · corrodedTYS, DURING A SCHEDULED INSPECTION THE LOWER RAMP ANGLE ON OMEGA BEAM WAS FOUND CORRODED AT FR20. MAINTENANCE REMOVED AND REPLACED THE LOWER RAMP ANGLE IAW EMB-135/145 SRM 51-40-02. THE REPAIR WAS SATISFACTORY AND THE AIRCRAFT WILL BE RELEASED UPON COMPLETIOSDR C2XA03TY057Floorbeam · corrodedTYS, DURING A SCHEDULED INSPECTION THE DIGITAL PLATE WAS FOUND CORRODED AT FR20 & 22. MAINTENANCE REMOVED AND REPLACED THE LEFT TOP CAP DIGITAL IAW EMB-135/145 SRM 51-40-02. THE REPAIR WAS SATISFACTORY AND THE AIRCRAFT WILL BE RELEASED UPON COMPLETION OF INSSDR C2XA03TY056Floorbeam · corrodedTYS, DURING A SCHEDULED INSPECTION THE CARGO DOOR CUTOUT LOWER BEAM WAS FOUND CORRODED. MAINTENANCE REMOVED AND REPLACED THE LOWER BEAM, IAW EMB-135/145 SRM 51-40-02. THE REPAIR WAS SATISFACTORY AND THE AIRCRAFT WILL BE RELEASED UPON COMPLETION OF INSPECTIONSDR C2XA03TY055Floorbeam · corrodedTYS, DURING A SCHEDULED INSPECTION THE LEFT AFT OUTBOARD FLOORBEAM IN LAV HAS CORRODED INSERTS AND SURFACE OXIDATION. MAINTENANCE REMOVED AND REPLACED THE CARBON FLOORBEAM IAW EMB-135/145 SRM 51-40-02. THE REPAIR WAS SATISFACTORY AND THE AIRCRAFT WILL BE RELSDR C2XA03TY054Floorbeam · corrodedTYS, DURING A SCHEDULED INSPECTION SURFACE OXIDATION WAS FOUND AROUND FASTENERS ON LAV FLOOR CENTER BEAM. MAINTENANCE REMOVED AND REPLACED THE FLOORBEAM TOP CAP IAW EMB-135/145 SRM 51-40-02. THE REPAIR WAS SATISFACTORY AND THE AIRCRAFT WILL BE RELEASED UPON SDR USAA030056Floorbeam · corrodedFOUND FLOORBEAM CORROSION 1 INCH BY 3 INCH AREA, UPPER SURFACE FLOORBEAM UPPER CHORD BS 1320, LBL 24. FLOORBEAM UPPER CHORD REPAIR, UPPER CHORD REPLACEMENT LBL 54-RBL 36 PER T/R 53-15-01. (M)SDR USAA030057Floorbeam · corrodedFOUND FLOORBEAM CORRODED 1 INCH BY 2 INCH, UPPER SURFACE FLOORBEAM UPPER CHORD BS 1320, RBL 35. FLOORBEAM UPPER CHORD REPAIR, UPPER CHORD REPLACEMENT LBL 54 - RBL 36 PER T/R 53-15-01. CORROSION LEVEL 1, TASK NR C53-251 AND 252-02. (M)SDR SWAA031105Floorbeam · crackedDURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAM CRACKED AT BS 661, BL 0. REPAIRED FLOORBEAM PER SWA EA.SDR SWAA031104Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAM CORRODED AT BS 794, RBL 3. REPAIRED FLOORBEAM PER SWA EA.SDR SWAA031102Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAM CORRODED AT BS 500C + 16, LBL 19. REMOVED AND REPLACED FLOORBEAM SECTION PER SRM.SDR ASAA0310451Floorbeam · corrodedOKC - DURING C-CHECK, FOUND FLOORBEAM AT FUSELAGE STATION 543-602, BUTTOCK LINE 0 CORRODED. REMOVED CORROSION AND REPAIRED PER EA. (M)SDR ASAA0310467Floorbeam · corrodedDURING C-CHECK, FOUND THE FLOORBEAM AT FUSELAGE STATION 947, LEFT BUTTOCK LINE 26, LEFT BUTTOCK LINE 30 CORRODED. REPAIRED FLOORBEAM PER EA. (M)SDR ASAA0310469Floorbeam · corrodedDURING C-CHECK, FOUND THE FLOORBEAM AT FUSELAGE STATION 967, LEFT BUTTOCK LINE 40 CORRODED. REPAIRED FLOORBEAM PER EA. (M)SDR ASAA0310452Floorbeam · corrodedOKC - DURING C-CHECK, FOUND FLOORBEAM AT FUSELAGE STATION 590, LEFT BUTTOCK LINE 24.5 CORRODED. REMOVED CORROSION AND REPAIRED PER EA. (M)SDR ASAA0310455Floorbeam · corrodedDURING C-CHECK, FOUND FLOORBEAM AT FUSELAGE STATION 540-706, RIGHT BUTTOCK LINE 24.5 CORRODED. REMOVED DAMAGE AND REPAIRED PER EA. (M)SDR ASAA0310464Floorbeam · corrodedOKC - DURING C-CHECK, FOUND FLOORBEAM AT FUSELAGE STATION 480, RIGHT BUTTOCK LINE 24.75, RIGHT BUTTOCK LINE 45.5 CORRODED. REMOVED DAMAGE AND REPAIRED PER EA. (M)SDR SIMA200314802Floorbeam · corrodedDURING AN IMBV INSPECTION, THE FORWARD DIGITAL WAS FOUND CORRODED BELOW SRM LIMITS. BLENDED THE CORRODED AREA AND TREATED THE BARE METAL SURFACE. FABRICATED A REPAIR DOUBLER AND INSTALLED. REPAIR DONE IAW EMB STATMENT IC2003-145/1604, PARA 12. (M)
Back to JASC 5315