JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GAIA00576Floorbeam · corrodedDISCREPANCY: DURING HEAVY CHECK FOUND: FLOORBEAM AT BS700 HAS CORROSION ON LOWER CAP, FORWARD SIDE AT RBL 25. CORRECTIVE ACTION: INSTALL NEW FITTING 69-14453-1 IAW 727 SRM 51-30-2SDR USAA001289Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED .250 INCH, BS 986, LBL 4 TO RBL 38 NUTPLATE HOLES. CORROSION LEVEL 1, C53-107-02. SPLICED T-CAP PER TR 53-60-01. (M)SDR USAA001287Floorbeam · corrodedCLT - FOUND T-CAP CORRODED 31 INCHES, STATION 328. INSTALLED DOUBLER T-CAP PER SRM 51-10-02 AND 53-10-51. (M)SDR USAA001286Floorbeam · corrodedCLT - FOUND T-CAP CORRODED 20 INCHES, STATION 328. INSTALLED NEW T-CAP AND REPAIR ANGLE PER SRM 51-10-02 AND 53-10-51. CORROSION LEVEL 1. (M)SDR TWAA0013313Floorbeam · corrodedDURING CHECK-C MAINT, FOUND FLOORBEAM CORRODED AT C1 GALLEY, STA 200 FROM RBL 44 TO RBL 56. REMOVED OLD FLOORBEAM AND MADE NEW FROM DAC PRINT 5930536 AND 5930540 FROM EXTRUSION AND FASTENED PER SRM 51-30-02 PAGE 3.SDR SWAA001561Floorbeam · damagedDURING SCHEDULED TRANSITION CHECK, FOUND BS 1016 FLOORBEAM LOWER WEB DAMAGE, LBL 13 TO LBL 16, WL 200. REPAIRED BEAM PER SRM.SDR USAA001273Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 1 INCH BY 1 INCH, STATION 344. CORROSION LEVEL 1. FABRICATED NEW T-CAP AND DOUBLER PER SRM 53-10-51. (M)SDR USAA001272Floorbeam · corrodedFOUND FLOORBEAM CORRODED .5 INCH BY .5 INCH, STATION 328, LBL 30 T-CAP OF FLOORBEAM. CORROSION LEVEL 1. FABRICATED NEW SPLICE ANGLE AND FILLER PER SRM 51-70-12 FIG 1. (M)SDR 00FDEA00616Floorbeam · crackedNR 414 AT FRAME 33, FOUND MAIN DECK FLOOR CROSS BEAM CRACKED AT VERTICAL MILLED WEB AT .375 INCH BELOW UPPER FLANGE AT AXIX Y - 700. *S/D* REMOVED AND REPLACED PER FEDEX EA 6-5100-52040 & A310 SRM SUPL MANUAL 53-10-15, FIG 201.SDR 0003011243Floorbeam · corrodedDURING H/COMMISSIONING CHECK FOUND CORROSION ON THE TOP OF THE FLOOR SUPPORT TEE CHORD BS 2007 AT LBL 20 TO LBL 24. REPAIRED PER EA 12-175714.SDR TWAA0013311Floorbeam · corrodedDURING CHECK-C MAINT, THE STA 200 FLOORBEAM WEB WAS CORRODED AT LBL 64. REPAIRED WEB PER SRM 53-01, PAGE 18. INSTALLED NEW SUPPORT CASTING PER DRAWINGS 9911518 AND 9911595.SDR COMA0060663Floorbeam · crackedTHE FLOOR MEMBER (P/N 600-34017-17) AT FS 280.0 HAS A 2 INCH CRACK, APPROXIMATELY 1 - 2 INCHES TO THE RIGHT OF FLOOR SUPPORT AT RBL 9.0. PERFORMED A MAJOR REPAIR TO CRACKED FLOOR MEMBER (P/N 600-34017-17) AT FS 280.0 IAW WVAC EO 601R-53-1589.SDR AWXA0000554Floorbeam · crackedC-CHECK, FLOORBEAM WEB LOWER TEE CHORD CRACKED AT FS 717 RBL 25. FABED AND INSTALLED REPAIR PARTS IAW ER 15-5311-00193-554.SDR AWXA0000553Floorbeam · crackedC-CHECK, FLOORBEAM WEB LOWER TEE CHORD CRACKED AT STA 700 BL-0. FABED AND INSTALLED REPAIR PARTS IAW ER 15-53-11-00193-SS3.SDR AWXA0000552Floorbeam · crackedC-CHECK, FLOORBEAM WEB LOWER T CHORD CRACKED AT STA 670 - 690 RBL 45. FABED AND INSTALLED REPAIR PARTS ON FLOORBEAM WEB IAW ER 15-5311-00193-552.SDR USAA001271Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED .0500 INCH, BS 967, LBL 18.5. INSTALLED REPAIR ANGLES PER SRM 53-10-51. (M)SDR 0002996717Floorbeam · corrodedDURING M CHECK, FOUND CORROSION ON FLOORBEAM AROUND TWO FASTENER HOLES AT BS 2000 RBL 98. REPAIRED PER EA 67-178812.SDR USAA001250Floorbeam · corrodedCLT - FOUND T-CAP CORRODED 1 INCH BY 1.5 INCH IN 14 PLACES, STATION 1016 END TO END TOP OF T-CAP. CUT REMOVED AND REPLACED T-CAP PER TR 53-10-05A. (M)SDR USAA001255Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED .25 INCH, STATION 312, LBL 20 - RBL 20 UPPER CHORD T-CAP SCREW HOLES. REPAIRED DOUBLER/SPLICE OF NEW T-CAP PER SRM 53-00-51 FIG 201. (M)SDR USAA001249Floorbeam · corrodedCLT - FOUND T-CAP CORRODED 1 INCH BY 1 INCH IN TWELVES PLACES, STATION 1006 END TO END TOP. CUT AND REMOVED AND REPLACED T-CAP PER TR 53-10-05A. (M)SDR USAA001248Floorbeam · corrodedCLT - FOUND BEAM CORRODED 1 INCH BY 1 INCH IN 10 PLACES, BS 344, LBL 56 TO RBL 31. INSTALLED T-CAP PER SRM 53-10-51. CORROSION LEVEL 1/ C53-107-02. (M)SDR USAA001246Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 8 INCHES, BS 967, LBL 49 TOP OF FLOORBEAM. INSTALLED UPPER T-CAP PER TR 53-10-05A. (M)SDR USAA001247Floorbeam · corrodedCLT - FOUND T-CAP CORRODED 1 INCH BY 2 INCH IN 12 AREAS, STATION 294, LBL 1. INSTALLED DOUBLER PER SRM 51-40-00 AND 51-10-51. (M)SDR CALA0001452Floorbeam · corrodedFLOORBEAM CORRODED AT STA 218 LBL 10 - RBL 10. REMOVED AND REPLACED FLOORBEAM PER SRM 51-30-2, 51-10-4, 51-10-3, AND 51-30-5.SDR CALA0001450Floorbeam · corrodedFLOORBEAM CORRODED AT FORWARD ENTRY STA 168 RBL 9 - RBL 43. REPLACED FLOORBEAM PER SRM 51-10-04, 51-30-03, 51-30-2, AND 51-30-5.SDR CALA0001449Floorbeam · corrodedFLOORBEAM ELONGATED HOLES AND CORROSION AT STA 160 LBL 5 - RBL 5. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED BEAM PER SRM 51-30-5, 51-10-4, AND 51-10-3.SDR CALA0001444Floorbeam · corrodedSTA 218 LBL 10 - RBL 10 FLOORBEAM OUT OF LIMITS FWD ENTRY. REMOVED FLOOR SUPPORT IAW SRM 51-30-2, RECEIVED NEW FLOORBEAM ON T9010, LOCATED AND DRLLED IAW SRM 51-10-4, TREATED AND PRIMED IAW SRM 51-10-3, INSTALLED FLOORBEAM IAW SRM 51-30-5.SDR CALA0001442Floorbeam · corrodedSTA 200 LBL 5- FLOORBEAM IS CORRODED OUT OF LIMITS FWD ENTRY. REMOVED BEAM FOUND TO BE OUT OF LIMITS, FAB NEW BEAM ON T8981, TREATED AND PRIMED IAW SRM 51-10-3, DRILLED AND INSTALLED IAW SRM 551-30-2.SDR CALA0001440Floorbeam · corrodedSTA 168 LBL 16-BLL 38 FLOORBEAM HAS CORROSION FWD ENTRY. REMOVED FLOORBEAM IAW SRM 51-30-2, SENT TO FAB SHOP FOR NEW FLOORBEAM, TREATED AND PRIMED IAW SRM 51-10-3, LOCATED AND DRILLED FLOOR SUPPORT IAW SRM 51-10-3, LOCATED AND DRILLED FLOOR SUPPORT IAW SRM 51SDR CALA0001267Floorbeam · wornINSPECTION FOUND CABIN FLOORBEAM WORN AT RT CENTER OF FORWARD CARGO BEAM, STA 389. REPAIR DOUBLERS WERE INSTALLED IAW SRM 53-05, FIGURE 86.SDR USAA001244Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED .250 INCH, UPPER T-CAP STATION 467 FROM RBL 55 TO LBL 55. REPLACED TOP T-CAP PER TR 53-10-05A. (M)SDR F3LA00200Floorbeam · corrodedDEN - DURING C-3 CHECK, INSPECTION REPORTED CORROSION IN AND AROUND FLOORBEAM CLIP NUT HOLES, STATION 294, BL 8R TO BL 44R. MAINTENANCE REMOVED CORROSION PER MM 51-31-31, FABRICATED REPLACEMENT PARTS AND INSTALLED PER 51-10-2, 53-10-2, AND 53-10-9, FIG 5. (MSDR TWAA0013109Floorbeam · brokenDURING OP 15 MAINT CHECK, THE FLOORBEAM WAS BROKEN AT STA 680 APPROX 56 IN LBL. INSTALLED NEW FLOORBEAM WITH HLT HI LOCK 436 PER SSRM 51-40-501, PG 201.SDR DL73K001574Floorbeam · crackedA CRACK WAS FOUND IN THE RBL 24 LONGITUDINAL FLOORBEAM AT APPROX FS 656. THE CRACK WAS REMOVED AND A DOUBLER WAS INSTALLED PER ERA 334706-14 AT HMV.SDR F3LA00214Floorbeam · corrodedDEN - DURING C-3 CHECK INSPECTION, FOUND FLOORBEAM UPPER CHORD AT STATION 277 CORRODED FROM LBL 17 TO LBL 49. MAINTENANCE FABRICATED REPLACEMENT UPPER CHORD PER SRM 53-10-02 AND INSTALLED PER SRM 51-30-0. (M)SDR F3LA00199Floorbeam · corrodedDEN - DURING C-3 CHECK INSPECTION REPORTED CORROSION IN AND AROUND FLOORBEAM CLIP NUT HOLES, STATION 294, BL 8R TO BL 44R. MAINTENANCE REMOVED CORROSION PER MM 51-31-31. FABRICATED REPLACEMENT PARTS AND INSTALLED PER 51-10-2, 53-10-2, AND 53-10-9 FIG 5. (M)SDR 00FDEA00541Floorbeam · crackedFOUND FLOORBEAM AT FRAME 36 CRACKED AT THREE LOCATIONS: A) 3 INCHES LENGTH AT Y+700. B) 3 INCHES LENGTH AT Y+900. C) 1 INCH LENGTH AT Y-700. *S/D* REMOVED AND REPLACED PER FEDEX EA 6-5100-52040 & A310 SRM SUPPLEMENTAL MANUAL 53-10-15, FIG 201. THE DEFECTSSDR F3LA00195Floorbeam · corrodedDEN - DURING C-3 CHECK, INSPECTION REPORTED CORROSION AROUND NUT PLATE, STATION 294 BL 0, FORWARD CABIN FLOORBEAM CAP. MAINTENANCE REPLACED FLOORBEAM PER SRM 51-21-31. (M)SDR F3LA00194Floorbeam · corrodedDEN - DURING C-3 CHECK INSPECTION REPORTED CORROSION ON FLOORBEAM AT STATION 294.5 UNDER FORWARD GALLEY, INBOARD OF R-1 DOOR. MAINTENANCE REPLACED FLOORBEAM PER SRM 51-21-31. (M)SDR SWAA001517Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND BS 986 FLOORBEAM CORRODED, RBL 32 TO RBL 40. REPAIRED BEAM PER SRM.SDR RRXA003128Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOORBEAM TOP STRAP AT STA 1580 AND X+30 THROUGH X+43, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SUPPORT IAW DC-8 SRM 51-1-4 ASDR TWAA0013513Floorbeam · corrodedDURING OP 15 MAINT CHECK HAD CORROSION ON SHORT FLOORBEAM AT STA 200, LBL 44 IN TO LBL 56 INCHES. MECHANICALLY REMOVED CORROSION PER SPM 6-80-01. REMOVED CORRODED PART AND FABRICATED NEW AND INSTALLED PER SRM 53-11-1, FIG 11 SHEET 1 AND 2.SDR AWXA0000530Floorbeam · corrodedC-CHECK CORROSION LEVEL 1, CABIN FLOORBEAM STA 294 - 344 RBL 60 MOP SILL HAS CORROSION. REMOVED DAMAGED AREA, FABRICATED REPAIR PARTS AND INSTALLED PARTS IAW 737 SRM 51-70-13 AND SRM 51-40-02.SDR TWAA0016105Floorbeam · corrodedDURING OP 15 MAINT CHECK THE FWD ENTRY AREA HAD CORROSION ON FLOOR SUPPORT BEAM AT STA 200, LBL 0 TO 20 INCHES. FABRICATED AND REPLACED CORRODED PART PER SRM 53-11-1, FIG 11 SHEET 1 AND 2.SDR TWAA0013222Floorbeam · crackedDURING CHECK-C MAINT, AFT CARGO COMPT AT STA 1155 THE FLOORBOARD SUPPORT WAS CRACKED AT LBL 20 TO RBL 5 IN. REPLACED FLOOR SUPPORT PER SPM 6-70-01 PAGE 3, DRAWING 5936597, SRM 51-60 AND SRM 51-20.SDR 0002826717Floorbeam · corrodedDURING M CHECK FOUND CORROSION AT BS 600 RBL 40 FORWARD CARGO FLOORBEAM UPPER CHORD AROUND NUT PLATE HOLES. REPAIRED PER EA 67-178047.SDR SIMA2374Floorbeam · corrodedSAW - DURING CPCP-4 INSPECTION, MAINTENANCE FOUND FLOORBEAM 39 CORRODED. MAINTENANCE REPAIRED THE FLOORBEAM IAW SRM 53-00-00 FIGURE 429. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR SIMA2375Floorbeam · misdrilledSAW - DURING CPCP-4 INSPECTION, AFTER REMOVING THE LEFT FORWARD SEAT TRACK MAINTENANCE DISCOVERED THAT FLOORBEAM 16 HAD A HI-LOCK HOLE MISDRILLED. MAINTENANCE REPAIRED THE FLOORBEAM IAW SRM 53-00-00 FIGURE 429. AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR RRXA003316Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOORBEAM AROUND HUCKBOLTS AT STA 920 AND -21-X61 THROUGH -X67, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 53-2SDR F3LA00187Floorbeam · corrodedDEN - FOUND DURING C-3 CHECK INSPECTION REPORTED TOP CHORD OF FLOORBEAM CORRODED AT STATION 328 BETWEEN LBL 40 AND RBL 40. MAINTENANCE REMOVED DAMAGED SECTION OF TOP CHORD. FABRICATED AND INSTALLED REPLACEMENT SECTION PER SRM 51-30-00. (M)
Back to JASC 5315