JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR L1GA200000076Floorbeam · crackedA CRACK WAS FOUND AT STATION 996 BL 28R FLOORBEAM WEB.SDR 0001919880Floorbeam · crackedSUBFLOOR UNDER PANELS 71 & 72 OUTBOARD HORIZONTAL ANGLE ON TOP OF CENTER TANK CRACKED AT STA 755. REPAIRED PER EA 98-172430 AND SRM 51-30-5. L/P 1437803SDR TWAA0007602Floorbeam · crackedDURING OP 16 MAINT CHECK, FOUND STA 598, RBL 54 IN, HAD FLOOR MEMBRANE CRACKED. INSTALLED DOUBLER ON WEB PER SRM 53-01-9, FIG 2.SDR CALA0000664Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT STA 200, RBL 44 TO RBL 54. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 51-30-05.SDR SWAA000876Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND BS 986 FLOORBEAM UPPER SURFACE CORRODED. REMOVED AND REPLACED FLOORBEAM UPPER T-CAP PER SRM.SDR RRXA002417Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 500 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21, 51-SDR RRXA002213Web · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE, DOUBLE DRILLED HOLES, GOUGES AND MISSING NUT PLATES AT VARIOUS PLACES AT STA 225 TO 330 AND L21L TO L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8.SDR RRXA001759Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE MAIN CABIN FLOORBEAM AT FS 1750 AND BL 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED NEW FLOORBEAM IAW DC-8 SRM 51-1-20D.SDR RRXA001735Floorbeam · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE UPPER FWD FLANGE FLOORBEAM AT FS 680 AND RBL 52, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR SWAA000866Floorbeam · crackedDURING SCHEDULED 1/2D CHECK, FOUND BS 947 FLOORBEAM CRACKED, LBL 56. REPAIRED BEAM PER SRM.SDR F3LA00083Floorbeam · corrodedDEN - DURING C-7 CHECK, INSPECTION REPORTED BARE METAL AND SURFACE CORROSION ON FLOORBEAM NEAR CENTER OF FLOOR AT BS 950. MAINTENANCE BURNISHED SURFACE CORROSION AND REPLACED INTERCOSTAL BETWEEN BS 950 AND BS 966, LBL 8 PER SRM 53-10-09. (M)SDR UPS00832731Floorbeam · damagedINSPECTION TYPE:C2, CABIN, ELONGATED HOLE IN FLOORBEAM AT STA 834 RBL 13. ROUTED OUT DAMAGED AREA IAW TIMCO SRM STD 5310-001 PG 6 AND MID FOR 2 REPAIR ANGLES IS 7075-0 .071 PO NR 297242 IAW TIMCO STD REPAIR MANUAL 5310-001 PG 4 & 6. FABBED 2 ANGLES AND FILLSDR USAA000678Floorbeam · corrodedCLT - FLOORBEAM HAD LEVEL 1 CORROSION, 1 INCH BY 1 INCH, BS 947, LBL 18. REPLACED T-CAP PER SRM 53-10-2. (X)SDR USAA000677Floorbeam · corrodedCLT - FLOORBEAM HAD LEVEL 1 CORROSION, 1 INCH BY 1 INCH, BS 947, LBL 14. REPLACED T-CAP PER SRM 53-10-2. (X)SDR USAA000676Floorbeam · corrodedCLT - FLOORBEAM HAD LEVEL 1 CORROSION, 2 INCHES BY 3 INCHES, BS 947, LBL 4.5, RBL 5. REPLACED T-CAP PER SRM 53-10-2. (X)SDR USAA000670Floorbeam · crackedCLT - FLOORBEAM CRACKED0 .500 INCH BY 2 INCH, BS 967, RBL 17.5, CORROSION LEVEL 1. REPLACED ANGLE PER EA67156. (X)SDR SWAA000852Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND BS 344 FLOORBEAM UPPER SURFACE CORRODED, LBL 11. REPAIRED FLOORBEAM PER SRM.SDR ABXA000269Intercostal · corrodedDURING ''C'' CHECK, FOUND CORROSION ON FLOORBEAM INTERCOSTAL AT STAION 984 AND RBL 30 RIGHT. REPAIRED IAW DC9 SRM DRAWING K05159.SDR SWAA000838Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND BS 312 FLOORBEAM UPPER SURFACE CORRODED, LBL 11 TO RBL 11. REPAIRED BEAM PER SRM.SDR 20000629AP005Seat Track · corrodedSAW - DURING CPCP-2 INSPECTION, FOUND LEFT AFT OUTBOARD, RIGHT AFT OUTBOARD, LEFT FLIGHT ATTENDANT AND RIGHT FLIGHT ATTENDANT SEAT TRACKS CORRODED BEYOND LIMITS. REMOVED AND REPLACED CORRODED SEAT TRACKS IAW EO E905300-013. (M)SDR 20000629AP004Seat Track · corrodedDURNG CPCP-2 INSPECTION, FOUND LEFT AFT OUTBOARD, RIGHT AFT OUTBOARD, LEFT FLIGHT ATTENDANT AND RIGHT FLIGHT ATTENDANT SEAT TRACKS CORRODED BEYOND LIMITS. REMOVED AND REPLACED CORRODED SEAT TRACKS IAW EO E905300-013. (M)SDR 20000629AP003Floorbeam · corrodedSAW - DURING CPCP-2 INSPECTION, FOUND FLOORBEAMS 36, 38, 39 AND 40 CORRODED BEYOND LIMITS. REMOVED AND REPLACED CORRODED FLOORBEAMS 36 AND 38 IAW SRM 51-25-01. REPAIRED FLOORBEAMS 39 AND 40 IAW SRM 53-61-40. (M)SDR 20000629AP002Floorbeam · corrodedSAW - DURING CPCP-2 INSPECTION, FOUND FLOORBEAM 36, 38, 39 AND 40 CORRODED BEYOND LIMITS. REMOVED AND REPLACED CORRODED FLOORBEAMS 36 AND 38 IAW SRM 51-25-01. REPAIRED FLOORBEAMS 39 AND 40 IAW SRM 53-61-40. (M)SDR 20000629AP001Floorbeam · corrodedSAW - DURING CPCP-2 INSPECTION, FOUND FLOORBEAM 36, 38, 39, AND 40 CORRODED BEYOND LIMITS. REMOVED AND REPLACED CORRODED FLOORBEAMS 36 AND 38 IAW SRM 51-25-01. REPAIRED FLOORBEAMS 39 AND 40 IAW SRM 53-61-40. (M)SDR SIMA1254Floorbeam · corrodedSAW - DURING CPCP-2 INSPECTION, FOUND FLOORBEAMS 36, 38, 39 AND 40 CORRODED BEYOND LIMITS. REMOVED AND REPLACED CORRODED FLOORBEAMS 36 AND 38 IAW SRM 51-25-01. REPAIRED FLOORBEAMS 39 AND 40 IAW SRM 53-61-40. (M)SDR AWXA0000295Floorbeam · corrodedC-CHECK, CORROSION LEVEL 2. CABIN FLOORBEAM AT STA 328 BL 0 CORRODED ON UPPER SURFACE. REMOVED AND REPLACED DAMAGED T CAP FROM STA 328, LBL 33 TO RBL 64 IAW 737 SRM 53-10-51 FIG 205 AND DWG 65-45834.SDR AWXA0000294Floorbeam · corrodedC-CHECK CORROSION, LEVEL 2. CABIN FLOORBEAM AT STA 312, BL 0 TO RBL 12 CORRODED ON UPPER SURFACE. REPAIRED FLOORBEAM IAW 737 SRM 51-10-02 PG 15 AND 737 SRM 53-10-51 FIG 205.SDR AWXA0000293Floorbeam · corrodedC-CHECK CORROSION, LEVEL 2. CABIN FLOORBEAM AT STA 294 RBL 12 TOP SURFACE CORRODED. REPAIRED FLOORBEAM IAW 737 SRM 51-10-02 PG 15 AND 737 SRM 53-10-51 FIG 201.SDR 0001746304Floorbeam · corrodedDURING ''M'' CHECK, FOUND CORROSION ON UPPER DECK FLOORBEAM, UPPER CHORD AT BS 1020, RBL 13 TO LBL 13. REPAIRED PER EA 63-175810.SDR USAA000656Floorbeam · corrodedCLT - FOUND BEAM CRACKED 2 INCHES BY 55 INCHES, NUMEROUS CORROSION LEVEL 2, FLOORBEAM AT FS 344 BETWEEN RBL 11 AND LBL 44. INSTALLED NEW T-CAP AND SPLICE PER SRM 53-10-51. (M)SDR RRXA002469Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 300 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW EO NR 00-047 WITH APPROSDR RRXA002468Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM AT STA 270 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8 SRM 51-1-21 AND EOSDR RRXA002225Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES TO THE FLOORBEAM 1180 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-20D AND EO NSDR RRXA002222Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM 1120 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SUPPORT IAW EO NR 00-047 WITH APPROVEDSDR RRXA002211Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOORBEAM IN THE UPPER CARGO COMPT AT FS 660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED STRAPS/FILLERS AND INSTALLED IAW SDR RRXA002208Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOORBEAM IN THE UPPER CARGO COMPT AT FS 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED HOLES IAW EO NR 00-0047 WITH APPROVSDR RRXA002207Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOORBEAM IN THE UPPER CARGO COMPT AT FS 1460, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED STRAPS AND FILLERS AND INSTALLED IAW EO NR SDR RRXA001751Floorbeam · crackedDURING A MAINTENANCE VISIT, FOUND A CRACK ALONG THE RADIUS OF THE UPPER FLANGE IN THE MAIN CABIN FLOORBEAM AT FS 1660 AND RBL 48, WL-1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED RESDR RRXA001733Floorbeam · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE MAIN CABIN FLOORBEAM UPPER CAP, FS 760 AND LBL 24 TO 44, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED AND INSTALLED IAW DALFORT AEROSPACE, L.SDR 00FDEA00310Floorbeam · corrodedLONGITUDINAL FLOORBEAM BS 760 - 848, LBL 45, WL 208. CORRODED AROUND NUT PLATES. *S/D* REMOVED AND REPLACED PART PER FEDEX SRM 51-30-02.SDR SIMA1202Floorbeam · corrodedSAW - FLOORBEAM 39 BETWEEN 14L AND 14R CORRODED BEYOND LIMITS. REMOVED AND REPLACED CORRODED SECTION OF FLOORBEAM IAW SRM 53-00-00. (M)SDR RRXA002305Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A CRACK ON LWR AFT LOBE OF FLOORBEAM AT FS 900 AND XCW 47 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC-8 SRM 53-2-0, 51-1-2SDR GAIA00273Floorbeam · damagedDURING LIGHT C-CHECK AT TIMCO/OSC, THE FOLLOWING DISCREPANCY WAS FOUND, ELONGATED HOLE IN FLOORBEAM AT STATION 360 LBL 45. REPAIRED FLOORBEAM PER IAW SRM 53-10-8. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR L1GA200000058Floorbeam · corrodedLEVEL 2 CORROSION FLOORBEAM UPPER SURFACE FS 980 BL 40L.SDR L1GA200000057Floorbeam · corrodedLEVEL 2 CORROSION LWR FLOORBEAM FLANGE FS 980 BL 45L.SDR L1GA200000053Floorbeam · corrodedLEVEL 2 CORROSION FLOORBEAM FS 980 UNDER LT LAV.SDR L1GA200000046Floorbeam · corrodedLEVEL 2 CORROSION FLOORBEAM UPPER SURFACE FS 980 BL 30L - BL 40L.SDR AALA20000722Floorbeam · corrodedTUL - CORROSION ON STA 1070 FLOORBEAM LOWER FLANGE AROUND 2 NDT PLATES, RBL 10 AND LBL 10. INSTALLED DOUBLER REPAIR PER ESO 11697 DATED 4-21-00. (X)SDR DL73E000862Floorbeam · crackedTHE RBL 45.5 FLOOR LONGITUDINAL FLOORBEAM OVER THE MLG WHEEL WELL WAS FOUND WITH A 12 INCH CRACK IN THE BEAM WEB BETWEEN FS 633 & 645. THE CRACKED SECTION OF WEB WAS CUT AND REMOVED. A NEW SECTION OF WEB WAS SPLICED IN WITH TWO ALUMINUM SPLICE DOUBLERSSDR AWXA0000280Floorbeam · corrodedC-CHECK, CABIN STA 294 LBL 24 TO RBL 24 FLOORBEAM HAS CORROSION. REMOVED DAMAGED PART IAW 737 SRM 53-10-08, FABRICATED REPAIR PARTS -1 THRU -8 SPLICE ANGLES (BAC 1490-2734 .063 T6511) T CHORD (10136-2401 T6511) IAW 737 SRM 53-10-51, TREATED AND PRIMED REPAI
Back to JASC 5315