SDR GAIA00257Floorbeam · corrodedDURING HEAVY C-CHECK AT TIMCO/OSC THE FOLLOWING DISCREPANCY WAS FOUND, STATION 420 TOP OF FLOORBEAM CORRODED AT LBL 25. REPAIRED UPPER CHORD PER IAW SRM 53-10-8. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR UPS00832467Floorbeam · corrodedINSPECTION TYPE:C2, AFT LOWER CARGO STA 1280 RBL 60 FLOORBEAM ATTACH ANGLE CORRODED. CUT OUT DAMAGED FLANGE. MAT ID FOR REPLACEMENT TEE .125 7075-T6511 (PO NR 215124), MAT ID FOR REPAIR ANGLES .140 7075-T6511 (PO NR 317193) IAW STD-5310-001. FABBED REPLACEMSDR DL73K000860Floorbeam · crackedCRACKING FOUND IN BL 0 LONGITUDINAL FLOORBEAM WEB AFT OF STA 717. RESULTED IN TRIMOUT OF BEAM WEB BETWEEN STA 700 AND 721. CORRECTIVE ACTION: ER/A 334337-14.SDR AWXA0000276Floorbeam · corrodedC-CHECK, CORROSION ON FLOORBEAM WEB AT STA 328 LBL 45.6. REMOVED DAMAGED AREA IAW 737 SRM 53-10-51 FIG 203, FABRICATED REPAIR DOUBLER AND FILLER IAW 737 SRM 53-10-51 FIG 1, TREATED AND PRIMED IAW 737 SRM 51-10-51 FIG 203, INSTALLED PARTS IAW 737 SRM 51-40-02SDR 20000427SH010Floorbeam · corrodedFLOORBEAM UPPER CHORD HAS DEEP SCRATCH AND CORROSION AT BS 1110 LBL 10 TO RBL 20 TO RBL 65, ZONE 4. REF: SUN COUNTRY A/L, W/C NR 4212 (CPC), NON-ROUTINE NR 22089. REPAIRED IAW TIMCO-REO NR S00010. (X)SDR 20000427SH009Floorbeam · corrodedCORROSION ON FLOORBEAM UPPER CHORD STA 380, RBL 26, ZONE 4. REF: SUN COUNTRY A/L, W/C NR 4113, NON-ROUTE NR 21825. TYPE INSPECTION - D-CHECK. REPAIR IAW B727 SRM 53-10-8 AND TIMCO REO NR S00030. (X)SDR 20000427SH008Floorbeam · corrodedCORROSION ON UPPER FLANGE OF FLOORBEAM AT BS 380, RBL 45 TO RBL 63, ZONE 4. RE: SUN COUNTRY A/L, W/C NR 4113 AND NONE ROUTINE NR 21822. TYPE INSPECTION: D-CHECK. REPAIRED IAW B727 SRM 53-10-8 AND TIMCO REO NR S00030. (X)SDR USAA000601Frame · corrodedCLT - FOUND CHORD CORRODED 2 INCHES BY 4 INCHES, STATION 500 AND 500A CHORD ANGLE AT STRINGER 26R. INSTALLED REPAIR ANGLE PER EA 67007 AND SRM 51-70-12. CORROSION LEVEL 2. (M)SDR USAA000603Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 1 INCH, STATION 344, LBL 42 - RBL 9 TOP OF FLOORBEAM. INSTALLED NEW SECTION PER SRM 51-40-02. (M)SDR USAA000604Floorbeam · corrodedCLT - FOUND FLOORBEAM CORRODED 1 INCH BY 1 INCH, BS 328, RBL TO SERV DOOR SILL. INSTALLED NEW T-CAP PER SRM 53-10-51. (M)SDR RRXA002495Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND A HOLE DRILLED THROUGH RADIUS IN WEB ON THE LONGITUDINAL FLOORBEAM AT STA 230 RT AND RBL 45.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLSDR SCNA00314Floorbeam · corrodedDURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS ON FLOORBEAM LOWER T-CAP IN THE AFT CARGO COMPARTMENT AT STA 1130, FROM RBL 45 TO LBL 45. REMOVED CORROSION IAW B727 SRM 51-10-06. FABRICATED REPAIR ANGLES FROM BAC 14902685 AND BAC 14982831. SDR 0001612290Floorbeam · corrodedDURING H CHECK, FOUND CORROSION ON FLOORBEAM UPPER CHORD. REPAIRED PER EA 22-175153.SDR USAA000600Floorbeam · corrodedCLT - FOUND FLOORBEAM T-CAP CORRODED 1 INCH BY 1 INCH, BS 1661 LBL 22. REMOVED AND INSTALLED NEW FABRICATED SECTION PER SRM 53-00-51. (M)SDR RRXA2212Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOORBEAM IN THE UPPER CARGO COMPT AT FS 600, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED STRAPS/FILLERS AND INSTALLED IAW SDR P2EA00144Floorbeam · corrodedSJO - DURING C-CHECK, CORROSION ON FLOORBEAM UPPER CHORD AT BS 344 BETWEEN LBL 12 AND LBL 19. REPAIRED FLOORBEAM UPPER CHORD AT BS 344 BETWEEN LBL 41 AND RBL 21 IAW SRM 53-10-9 FIG 5. SEE COOPESA W/O N10316-1-241, VAM100 NR 780 AND 912SDA123. (X)SDR AWXA0000263Floorbeam · corrodedC-CHECK CORROSION LEVEL2, CORROSION ON FLOORBEAM UPPER CHORD AT BS 986.5, RBL 16 TO RBL 43, WL 207. REMOVED PREVIOUS REPAIR IAW 737 SRM 53-60-51, FABRICATED NEW UPPER CHORD, AND INSTALLED PARTS IAW AMW ER 03-5365-00108-DL 1.SDR USAA000594Floorbeam · crackedCLT - FOUND LOWER FLOORBEAM 1 INCH CRACKED, BL 0, STATION 312-328 LOWER FLOORBEAM SUPPORT. REPAIRED PER SRM 51-10-02. (M)SDR TWAA0006606Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND IN CABIN, LT AFT LAV AT STA 983, LBL 53, FLOOR SUPPORT ANGLE HAD MARKED CORROSION. REMOVED CORROSION AND CLEANED AREA PER SPM 6-80-1. TREATED PER SRM 51-10-3.SDR TWAA0006505Floorbeam · damagedDURING OP 16 MAINT CHECK, FOUND IN CABIN CENTER SECTION, FLOOR MEMBRANE DAMAGED AT STA 737 TO 756, RT SIDE. FABRICATED PER SAMPLE PER SRM 53-11-3, ITEM 6. INSTALLED USING ORIGINAL TYPE FASTENERS PER SRM 51-30-2.SDR AWXA0000260Floorbeam · corrodedC-CHECK CORROSION LEVEL 1, CORROSION ON FLOORBEAM UPPER CHORD BS 967, LBL 43.5, WL 207. REMOVED DAMAGED AREA IAW 737 SRM 53-00-51, FABRICATED NEW REPAIR CHORD IAW 737 SRM 53-20-02 FROM BAC 1505-1000617 7075 T73, ALODINED AND PRIMED PARTS IAW 737 SRM 53-00-51,SDR AWXA0000261Floorbeam · corrodedC-CHECK CORROSION LEVEL 2, CORROSION ON FLOORBEAM UPPER CHORD BS 986.5 LBL 7 - 34 WL 207. REMOVED PREVIOUS REPAIR IAW 737 53-00-51, FABRICATED NEW UPPER CHORD IAW ER 00-5111 P2 FROM BAC 1505-10088, 7075T6 511 AND BAC 1490-2738 7075T6 .125 AND INSTALLED IAW SDR SWAA000777Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND BS 328 FLOORBEAM UPPER SURFACE CORRODED, RBL 26 TO RBL 43. REPAIRED BEAM PER SRM.SDR SCNA00327Floorbeam · corrodedDURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS ON FLOORBEAM TOP SURFACE AT STA 460 LBL 24 TO LBL 64. REMOVED CORROSION IAW B727 SRM 51-10-06. TRIMMED OUT DAMAGED AREA IAW B727 SRM 53-10-08. FABRICATED 1 DOUBLER ANGLE FROM 7075 T6 .100., FSDR SCNA00322Floorbeam · corrodedDURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS AT STA 440 BL 0 FLOORBEAM ON TOP SURFACE. REMOVED UPPER T-CAP PORTION OF FLOORBEAM FROM BL 15 IAW B727 SRM 53-10-08. FABRICATED 2 ANGLES FROM BAC14902183 AND BAC14902831, 2 STRAPS FROM BAC1512SDR SCNA00320Floorbeam · corrodedDURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS ON UPPER FLOORBEAM T-CAP BS 1110 FROM LBL 13.5 TO RBL 22. REMOVED CORROSION IAW B727 SRM 51-10-06. FABRICATED REPAIR PARTS IAW B727 SRM 53-10-08. TREATED AND PRIMED IAW B727 SRM 51-10-02, MM SDR SCNA00309Floorbeam · corrodedDURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND OUT OF LIMITS IN MAIN CABIN BS 1090 BL 0.0 UPPER FLOORBEAM T-CAP. TRIMMED OUT DAMAGED SECTION ON FWD UPPER FLANGE FROM LBL 1 TO RBL 1 IAW B727 SRM 53-10-08. FABRICATED 2 ANGLE DOUBLERS FROM BAC 14902685 ANDSDR RRXA002317Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED FLOORBEAM ON LWR CUSP AT STA 225 AND L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW GUSSET IAW DC-8 SRM 51-1-21 AND 51-1-4.SDR CALA0000526Floorbeam · corrodedFLOORBEAM CORRODED AT LBL 6 TO RBL 200. REMOVED AND REPLACED FLOOR SUPPORT PER SRM 51-30-02, 51-10-04, 51-10-03, AND 51-30-05.SDR CALA0000524Floorbeam · corrodedCABIN FLOORBEAM CORRODED AT STA 200 AT BL 0 TO RBL 44. REMOVED AND REPLACED FLOOR SUPPORT PER SRM 51-30-02, 51-10-03, 53-01 AND 51-106-04.SDR CALA0000520Floorbeam · corrodedFLOORBEAM CORRODED AT LBL 12 AT STA 200. REMOVED AND REPLACED SUPPORT PER SRM 51-10-3 AND 51-30-05.SDR TWAA0006429Floorbeam · corrodedDURING CHECK-C MAINT, AT STA 1322, RBL 17 TO RBL 51, LEVEL 2 CORROSION ON TOP OF FLOOR BEAM. REPAIRED AS INSTRUCTED ON ARA 16962. REMOVED CORROSION PER SPM 6-80-01. CORROSION TREATMENT PER ARA. TREATED PER SRM 51-10-3, PARAGRAPH 47.SDR AALA20000693Floorbeam · corrodedTUL - CORROSION AROUND NUTPLATES ON FLOORBEAM 1070 LOWER FORWARD FLANGE FROM LBL 15 TO RBL 20. INSTALLED STRAP ON FLOORBEAM PER ESO 11697 DATED 4-11-00. (X)SDR TWAA0006404Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND IN CABIN CORROSION ON FLOORBEAM AT STA 200, LBL 32 IN TO 43 IN. INSTALLED FLOORBEAM, FABRICATED FROM EXTRUSION, PER SRM 53-11-1, FIG 11. INSTALLED RIVETS PER SRM 51-30-2. PARTS TREATED PER SRM 51-10-3.SDR TWAA0006403Floorbeam · crackedDURING OP 16 MAINT CHECK, CABIN FLOOR PANEL NUMBER 62 HAD SUPPORT RIBS WITH 2 CRACKS. REMOVED AND REPLACED HAT SECTION WITH A NEW (P/N S2755898-1-144).SDR TWAA0006401Floorbeam · crackedDURING OP 16 MAINT CHECK, THE CABIN FLOORBEAM WAS CRACKED 3 INCHES AND HAD CORROSION AT STA 200, 1 IN LBL TO 30 IN LBL. REMOVED FLOOR SUPPORT AND FABRICATED NEW SUPPORT FROM EXTRUSION PER SRM 53-11-1. THE PART WAS PAINTED, INSTALLED RIVETS PER SRM 51-30-2.SDR SWAA000753Beam · corrodedDURING SCHEDULED 1/4D CHECK, FOUND FLOORBEAMS CORRODED, BS 860, LBL 8 - RBL 8 AND BS 770, LBL 3 - RBL 8. REPAIRED BEAMS PER SWA RA NR 1-A53-2021.SDR 20000615SH026Floorbeam · misdrilledDURING C-CHECK, FOUND MIS-DRILLED HOLE IN UPPER CAP OF FUSELAGE FLOORBEAM AT BS 427, LBL 37. (X)SDR 00FDEA00267Floorbeam · corrodedNR 457 CORROSION ON FLOORBEAM LWR SURFACE OF UPPER FWD FLANGE BS 48, RBL 25, WL 208. ** S/D ** R&R FLOORBEAM.SDR 00FDEA00265Floorbeam · corrodedNR 1064, 1070 LOWER CHORD CORRODED AROUND NUTPLATES FROM RBL 25- LBL 25. ** S/D ** R&R PER SRM 53-1-1.SDR TWAA0006504Web · crackedDURING OP 16 MAINT CHECK, IN THE FWD CABIN FOUND A CRACK IN MEMBRANE AT STA 160, LBL 6 INCHES. INSTALLED DOUBLER PER SRM 53-01, FIG 4 SHEET 3.SDR USAA000569Floorbeam · corrodedCLT - FOUND FLOOR FRAME CORRODED 1 INCH, STATION 312, BL 0, RBL 8, RBL 36. INSTALLED NEW T-CAP PER SRM 53-10-51. (M)SDR UIEA0020Floorbeam · crackedDURING SB747-53A2416 INSPECTION OF BS 1265, A CRACK WAS DISCOVERED EMANATING FROM A FRAME WEB FASTENER HOLE ON THE MAIN DECK FLOORWEB AT WL 199, LBL 120. REPAIRED ACCOMPLISHED BY INSTALLING A FRAME WEB DOUBLER, INTERCOSTAL DOUBLER AND AN ATTACHING ANGLE IAW ASDR GAIA00218Floorbeam · misdrilledDURING LIGHT C-CHECK AT TIMCO/OSC, FOUND BS 380, RBL 30 FLOORBEAM UPPER CHORD PREVIOUS REPAIR HAS A DOUBLE DRILLED HOLE. REPAIRED DAMAGED AREA IAW SRM 53-10-8. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GAIA00220Floorbeam · elongatedDURING LIGHT C-CHECK AT TIMCO/OSC, FOUND ELONGATED AND PLUGGED HOLES WERE FOUND IN FLOORBEAM AT STATION 420, RBL 45. REPAIRED FLOORBEAM DAMAGE IAW SRM 53-10=8. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR 00FDEA00256Floorbeam · corrodedNR 1156 WHILE WORKING CLOSE CARD FND CORROSION ON FLOORBEAM LOWER FLANGE AT BS 1130, RBL 5, WL 201 UNDER NUTCLIP. ** S/D ** R&R PER FEDEX SRM 53-10-1, 51-30-2, EA# 7-5310-50036A.SDR 00FDEA00260Floorbeam · corrodedCORROSION ON FLOORBEAM UPPER FLANGE BS 328, LBL 2 - 20, WL 208. *S/D* REMOVED AND REPLACED REPAIR PER SRM 53-10-1, 53-10-8, 51-20-1.SDR COMA0060362Floorbeam · corrodedTOP OF FLOORBEAM CAPS LBL 9, LBL 27, RBL 9, AND RBL 27 AT FS 280 TO 409 CORRODED. INSTALLED NEW BEAM CAPS IAW CANADAIR REO 601R-53-00-027 AND WVAC EO 601R-53-1211.SDR SWAA000730Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND BS 344 FLOORBEAM CORRODED, LBL 32 TO LBL 45. REPAIRED BEAM PER SRM.SDR P2EA00160Floorbeam · crackedSJO - DURING C-CHECK, FOUND FLOORBEAM LOWER CHORD BS 677, RBL 45.5 WL 202, WITH CRACK. L = 2.50 INCHES. W = 0.005 INCH. REPAIRED FLOORBEAM LOWER CHORD BS 677, RBL 45.5 WL 202, IAW BOEING FAX NR COO-SJO-00-00404H, DATED APRIL 21, 2000, DOCUMENTED ON FAA FORM
Back to JASC 5315