JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR TWAA0000908Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION AROUND NUT PLATE HOLES ON FLOOR SUPPORT, STA 200 RBL 5 IN TO LBL 5 IN. REMOVED CORROSION PER SPM 6-80-01, PAGE 1. FABRICATED FLOOR SUPPORT PER SPM 6-70-01, PAGE 2 AND 3, PARAGRAPH 4.SDR TWAA0000907Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION ON FLOORBEAM PANEL WEB FROM STA 160 TO 200, AND BETWEEN 6 IN LBL TO 6 IN RBL. COMPLETED REPAIR ON PANEL WEB FROM STA 160 TO 200, RBL 6 IN TO LBL 6 IN, DONE PER SSRM 53-10-111 AND DOUGLAS SERVICE BULLETIN 53 246 FIG 3 SDR AU000110Floorbeam · corroded(AUS) FLOORBEAM UPPER CHORD CORRODED AROUND ANCHOR NUTS IN THE AREABETWEEN RBL20 AND RBL60.SDR UPS00831536Floorbeam · corrodedINSPECTION TYPE:C123, MAIN CARGO FLOOR SUPPORT HAD CORROSION ON UPPER AND LOWER SURFACES FS 1746 LBL 1-31. REMOVED CORROSION ON FLOOR SUPPORT IAW DC8 SRM 51-1-8 (OUT OF LIMITS ). REMOVED FLOOR SUPPORT IAW DC8 SRM 51-3-0. FABRICATED AND INSTALLED IAW DC8 DACSDR UPS00831421Floorbeam · corrodedINSPECTION TYPE:C123, MAIN CABIN, CORROSION ON FLOOR SUPPORT AT FS 1700-1708 RBL 9.5-11.5. FABBED NEW PART IAW DC8 SRM 51-2-0 AND 51-1-8.SDR TWAA0001209Floorbeam · corrodedDURING CHECK-C MAINT, LATERIAL FLOORBEAM WAS EXTENSIVELY CORRODED AT WL 700, TOP OF FLOOR AND STA 266.5 AND RBL 11. INSTALLED A 4 IN BY 22 1/2 IN DOUBLER REPAIR PER SRM 51-70-11.SDR SWAA000031Floorbeam · corrodedDURING SCHEDULED TRASITION CHECK, FOUND FLOORBEAMS UPPER SURFACE CORRODED, BS 312, LBL 2 TO RBL 11, AND BS 328, RBL 25 TO RBL 42. REPAIRED FLOORBEAMS PER SRM.SDR COMA0060029Floorbeam · damagedFLOOR SUPPORT WEB P/N 601R31113-35 AT RBL 27 FS 333.0 TO FS 349.0 HAS EXISITNG DOUBLE DRILLED HOLE. PERFORMED A MAJOR REPAIR BY REPLACING FLOOR SUPPORT WEB P/N 601R31113-35 AT RBL 27 FS 333.0 - FS 349.0 IAW WVAC E O 601R-53-0789.SDR COMA0060028Floorbeam · crackedTHE FLOOR MEMBER PART NUMBER 600--34017 AT FS 280.00 IS CRACKED1/2 - 3/4 INCH, APPROXIMATELY 1 TO THE RIGHT OF FLOOR SUPPORT AT RBL 9.0. PERFORMED A MAJOR REPAIR BY REPAIRING FLOOR MEMBER P/N 600-34017-17 AT FS 280.0 IAW WVAC EO 601R-53-0786.SDR COMA0060022Floorbeam · corrodedFUSELAGE FLOORBEAM CAPS CORRODED AT LBL9 FS 300.0 - FS 349.0, RBL 9 FS 310.0 - FS 370.0, RBL 27 FS 310.0 - FS 347.0. PERFORMED A MAJOR REPAIR BY SPLICING IN NEW SECTION OF FUSELAGE FLOORBEAM CAPS IAW CRJ REO 601R-53-00-027.SDR COMA0060020Cap · corrodedFUSELAGE FLOORBEAM CAPS CORRODED AT LBL9 FS300.0 - FS349.0, RBL 9 FS 310.0 - FS370.0,RBL 27 FS 310.0 - FS 349.0 AND LBL 27 FS 310.0 - FS349.0. PERFORMED A MAJOR REPAIR BY SPLICING IN NEW SECTION OF FUSELAGE FLOORBEAM CAPS IAW CRJ REO 601R-53-00-027SDR CALA0000011Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT STA 312, LBL 12 TO RBL 12. A T-CHORD REPAIR WAS INSTALLED IAW SRM 53-10-51, FIGURE 205.SDR SWAA000022Floorbeam · corrodedDURING SCHEDULED D CHECK, FOUND FLOORBEAM UPPER SURFACE CORRODED, BS 1016, RBL 13 TO RBL 35. REPAIRED BEAM PER SRM.SDR RRXA001633Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 640, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED DOUBLERS FROM 7075-T6 AND INSTASDR CALA0000007Floorbeam · corrodedINSPECTION FOUND FLOORBEAM T-CHORD CORRODED AT CABIN FORWARD ENTRY, STA 328, LBL 20 TO RBL 48. A NEW T-CHORD WAS INSTALLED IAW SRM 53-40-02 AND 53-10-51, FIGURE 205.SDR ABXA000054Floorbeam · corrodedDURING C-CHECK, FOUND FLOORBEAM AT STATION 965 AND RBL 8 CORRODED. REPAIRED FLOORBEAM IAW ABX REA D95334885 MR.SDR ABXA000053Floorbeam · corrodedDURING C-CHECK, FOUND THE FLOORBEAM AT STATION 996 CORRODED AT THE RIGHT OUTBOARD END. REPAIRED IAW ABX REA D95334863 MR.SDR AALA2000030Floorbeam · corrodedTUL - CORROSION ON FLOORBEAM NR 6 AT FRAMES 78 AND 79, FIRST RIGHT OF CENTER. REPLACED CORRODED FLOORBEAM PER SRM 51-72-12. TST: 32,184 HOURS. CYCLES: 12,777. (X)SDR CALA0001467Floorbeam · corrodedCABIN FS 1338 FLOORBEAM CORRODED. REMOVED CORROSION, FABRICATED AND INSTALLED REPAIR FILLER PER SRM 53-05, 51-10-3, AND 51-30-5.SDR UPS00831315Floorbeam · corrodedINSPECTION TYPE:C1 CABIN FLOORBEAM AT FS 980, LBL 54, UPPER FLANGE IS CORRODED BEYOND LIMITS. REPAIRED FLOORBEAM IAW DH SK702-314.SDR SCNA99662Floorbeam · crackedDURING A HEAVY MAINTENANCE CHECK, THE FORWARD PIT STATION 979 FLOOR SUPPORT AT LBL 50 WAS FOUND CRACKED. REMOVED DAMAGED FLOOR SUPPORT IAW DC10 SRM 513501 VOL 2. FABRICATED FLOOR SUPPORT IAW DAC DWG ADA3626. ALODINED AND PRIMED FLOOR SUPPORT IAW DC10 SRM 51SDR SCNA99653Floorbeam · crackedDURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT VERTICAL FLANGE AT STATION 1853 LBL 75 WAS FOUND CRACKED. MATERIAL ID AND FABRICATION OF FLOOR SUPPORT IAW DAC DWG AGA3814. ALODINED AND PRIMED IAW DC10 SRM 512101 VOL 2. INSTALLED IAW DC10 SRM 513501 VOL SDR SCNA99652Floorbeam · crackedDURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT VERTICAL LEG AT STATION 1902 LBL 12 WAS FOUND CRACKED. REMOVED FLOOR SUPPORT MATERIAL ID FOR FLOOR SUPPORT. FABRICATED FLOOR SUPPORT IAW DAC DWG AGA7090. ALODINED AND PRIMED IAW DC10 SRM 512101 VOL 2 AND ISDR SCNA99651Floorbeam · crackedDURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT VERTICAL FLANGE AT STATION 1964 LBL 2 WAS FOUND CRACKED. REMOVED FLOOR SUPPORT MATERIAL ID AND FABRICATED IAW DAC DWG AGA7091. ALODINED AND PRIMED IAW DC10 SRM 512101 VOL 2. INSTALLED IAW DC10 SRM 513501 VSDR SCNA99650Floorbeam · wornDURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT AT STATION 1986 LBL 2 TO 18 HAS ELONGATED HOLES ON THE FORWARD LOWER SIDE OF THE LIP GROUND DOWN. MATERIAL ID AND FABRICATION FOR FLOOR SUPPORT IAW DC10 SRM 531600 VOL 3. ALODINED AND PRIMED IAW DC10 SRM 51SDR SCNA99649Floorbeam · wornDURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT AT STATION 1986 RBL 2 TO 18 WAS FOUND TO HAVE ELONGATED HOLES AND FORWARD LIP OF THE LOWER SIDE ON THE GROUND DOWN. REMOVED PANEL SUPPORT STATION 1986 RBL 2 MATERIAL ID PER DC10 SRM 531601 VOL 3. FABRICATEDSDR SCNA99637Floorbeam · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FLOOR BOARD SUPPORT ANGLE AT STATION 1278 RBL 40 TO 65 WAS FOUND CORRODED. REMOVED CORROSION IAW DC10 SRM 512101 VOL 2 FOUND TO BE OUT OF LIMITS IAW DC10 SRM 511001 VOL 2. REMOVED SUPPORT IAW DC10 SRM 513501 VOL 2. EXTRSDR SCNA99636Floorbeam · corrodedDURING A HEAVY MAINTENANCE CHECK, THE AFT ELEVATOR SUPPORT AND FLOORBEAM IN THE MAIN CABIN AT STATION 870 RBL 25 WAS FOUND CORRODED. REMOVED FLOORBOARD SUPPORT IAW DC10 SRM 513501 VOL 2. FABRICATED SUPPORT IAW DAC DC10 DWG ADA7605. ALODINED AND PRIMED IAW DSDR SCNA99634Floorbeam · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT AT STATION 1915 LBL 25 TO RBL 25 UPPER AND LOWER SURFRACES AT SCREW HOLES WERE FOUND CORRODED. FABRICATED FLOOR SUPPORT IAW DWG AGA7085. ALODINED AND PRIMED IAW DC10 SRM 512101 VOL 2. INSTALLED SUPPORT IAWSDR SCNA99633Floorbeam · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FLOOR SUPPORT AT STATION 1915 LBL 28 TO 54 FLOOR SUPPORT UPPER AND LOWER SURFACES AT SCREW HOLES WAS FOUND CORRODED. REMOVED SUPPORT EXTRUSION MATERIAL ID AND FABRICATED IAW DAC DWG AGA7090. ALODINED AND PRIMED IAW DC10 SDR SCNA99629Floorbeam · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FLOORBEAM SUPPORT AT STATION 457 LBL 59 TO LBL 75 WAS FOUND TO BE CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW DC10 SRM 530001. MATERIAL ID EXTRUSION AND FABRICATION IAW DAC DWG VZA7006. ALODINED AND PRIMEDSDR SCNA99619Floorbeam · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FLOORBOARD SUPPORT INTERCOSTAL AT STATION 1887 LBL 61 TO 90 WAS FOUND CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW DC10 SRM 530001 VOL 2. MATERIAL ID IAW DC10 SRM 531601 VOL 3. FABRICATED SUPPORT IAW DAC DWSDR SCNA99617Floorbeam · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FLOORBOARD SUPPORT AT STATION 1910 LBL 59 TO 86 WAS FOUND TO HAVE CORROSION. FABRICATED NEW FLOOR SUPPORT IAW DAC DWG AGA3814. ALODINED AND PRIMED AND INSTALLED FLOORBOARD SUPPORT.SDR SCNA99616Floorbeam · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FLOORBOARD SUPPORT INTERCOSTAL AT STATION 1986 LBL 60 TO 71 WAS FOUND TO BE CRACKED AND CORRODED. REMOVED SUPPORT EXTRUSION MATERIAL ID SUPPORT AND FABRICATED IAW DAC DWG AGA7091. ALODINED AND PRIMED IAW DC10 SRM 512101 SDR SCNA99614Floorbeam · corrodedDURING A HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND ON FLOORBOARD SUPPORT INTERCOSTAL STATION 1887 LBL 39 TO 57. MATERIAL ID FOR FLOOR SUPPORT AND FABRICATED FLOOR SUPPORT IAW DC10 SRM 531601 VOL 3. ALODINED AND PRIMED IAW DC10 SRM 512101 VOL 2. INSTALLESDR SCNA99613Floorbeam · corrodedDURING A HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND ON FLOORBOARD SUPPORT INTERCOSTAL STATION 1887 LBL28 TO 33. MATERIAL ID FOR THE SUPPORT AND FABRICATION IAW DC10 SRM 531601 VOL 3. ALODINED AND PRIMED FLOOR SUPPORT IAW DC10 SRM 512101 VOL 2. INSTALLED ISDR SCNA99611Floorbeam · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FORWARD PIT STATION 715 FLOORBOARD SUPPORT RBL 20 WAS FOUND CORRODED. REMOVED DAMAGED FLOORBOARD SUPPORT IAW DC10 SRM 513101 VOL 2. FABRICATED SUPPORT IAW DC10 530001 VOL 1. ALODINED AND PRIMED IAW DC10 SRM 512101 VOL 2SDR SCNA99610Floorbeam · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FORWARD PIT AT STATION 791 FLOOR SUPPORT LBL WAS FOUND CORRODED. REMOVED FLOOR SUPPORT IAW DC10 SRM 513501 VOL 2. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW DC10 SRM 530001 VOL 1. MATERIAL ID FOR FABRICATION OF NEWSDR SCNA99607Floorbeam · corrodedDURING A HEAVY MAINTENANCE CHECK, STATION 855 FLOOR SUPPORT RBL 40 WAS FOUND CORRODED. REMOVED FLOOR SUPPORT PER DC10 531201 VOL 2 MATERIAL IAW DC10 SRM 511001. FABRICATED IAW DC10 SRM 531201 VOL 3. ALODINED AND PRIMED IAW DC10 SRM 512001 VOL 2. INSTALLED SDR QXEA0000092Floorbeam · corrodedPDX - CORROSION ON UNDERSIDE OF UPPER FLANGE OF NR 1 GALLEY FLOOR SUPPORT BEAM, 7 FORWARD OF FRAME 3450. REPAIRED IAW FOKKER SRM 51-10-04, PAGE 9, PARAGRAPH 4 B AND C.SDR CALA9901756Floorbeam · corrodedINSPECTION FOUND FLOORBEAM UPPER T-CHORD CORRODED AT STA 1166, BL O TO O/B RT SIDE. THE CORROSION WAS REMOVED IAW SRM 51-10-6. AN ANGLE REPAIR WAS INSTALLED IAW ECRA 5310-03961.SDR CALA9901751Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED ON UPPER T-CHORD AT STA 1130, BL 0 TO O/B RT SIDE. THE FLOORBEAM WAS REPAIRED IAW ECRA 5310-03965 AND EA 27-5310-2-A0548.SDR QXEA0000093Floorbeam · corrodedPDX - NR 1 GALLEY FLOOR SUPPORT BEAM AFT END IS CORRODED ON TOP, JUST AFT OF FRAME 3870. REPAIRED IAW FOKKER SRM 51-10-04, PAGE 9, PARAGRAPH 4.SDR CALA9901745Bulkhead · crackedINSPECTION FOUND A 4 CRACK IN WEB AT AFT PRESSURE BULKHEAD STA 1183, STRINGER 2L FITTING. THE CRACK WAS STOP DRILLED IAW ECRA 5310-03958 AND A DIP WAS ISSUED TO REINSPECT THE REPAIR EVERY 3000 CYCLES.SDR CALA9901742Floorbeam · corrodedINSPECTION FOUND FLOORBOARD SUPPORT CORRODED AT STA 380-400, RBL 15. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 51-30-2.SDR SWAA992138Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND BS 1016 FLOORBEAM CORRODED ON UPPER SURFACE, RBL 31-36. REPAIRED BEAM PER SWA RA NR A1-353-2188.SDR AWXA9900499Floorbeam · corrodedFLOORBEAM FS 986.5 LBL 0 TO LBL 54 CORRODED OUT OF LIMITS. REMOVED DAMAGE FROM FLOORBEAM, FABRICATED REPLACEMENT OF BAC 1505-100617 R69033 AND 2 REPAIR STRAPS 7075 T6 QQA250/13 .063 R208344 AND .071 R698634 IAW 737 SRM 53-00-51 FIG 202. INSTALLED BEAM REPAIRSDR CALA9901722Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT FASTENER HOLES, STA 344, LBL 18-RBL 10. A CHORD WAS INSTALLED IAW SRM 53-10-51.SDR USAA991408Floorbeam · corrodedCLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY 1 INCH AREA OF CORROSION STATION 294.5 LBL 13 TO RBL 1 FLOORBEAM. CORROSION LEVEL 2. REPLACED T-CAP PER TR 53-10-04 B. (M)SDR USAA991377Beam · crackedCLT - DURING Q-5 CHECK VISUAL INSPECTION, FOUND A 3 INCH CRACK IN RADIUS OF FLOOR SUPPORT ANGLE STA 294.5 RBL 54. REMOVED AND REPLACED ANGLE PER SRM 51-40-1. (X)
Back to JASC 5315