JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DHL200071753DFloorbeam · corrodedAT D CK, FORWARD CARGO COMPARTMENT CORROSION AT CARGO FLOOR SUPPORT, STATION 574, LBL 2. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER B727 SRM 51-10-6. FABRICATED AND INSTALLED NEW ANGLE SUPPORT PER B727 SRM 51-40-4. REF: N/R 3640.SDR DHL200071746DFloorbeam · corrodedAT D-CK, INSIDE E/E COMPARTMENT AT BS 312 LBL 20.0 BOTTOM FLOORBEAM METAL STRAP CRACKED. INSTALLED DOUBLER REPAIR AT METAL STRAP AT BS 312 LBL 20.0 PER B727 SRM 53-10-8 FIG 6. REF: N/R 3623.SDR DHL2000717104Floorbeam · crackedAT D-CHECK, IN A/C BAY CABIN FLOORBEAM AT STA 740 UPPER CAP HAD 5.5 INCH CRACK AT RBL 26. CRACK EXTENDS BEYOND STOP DRILL. CUT OUT CRACKED SECTION, INSTALLED FLOORBEAM REPAIR UPPER CHORD BETWEEN RBL 15 TO 64 PER SRM 727 53-10-4, 48 LONG.SDR COMA0060066Floorbeam · corrodedTOP OF FLOORBEAM CAPS LBL9 AT FS 280 TO FS 409.0 RBL9 AT FS 280 TO FS 409.0 AND RBL 27 AT FS 280 TO FS 349 CORRODED BEYOND LIMITS. REMOVED AND REPLACED FLOORBEAM CAPS.SDR CALA0000046Floorbeam · crackedINSPECTION FOUND A 4 CRACK IN FLOORBEAM IN FORWARD CARGO AREA AT STA 939, LT SIDE. THE BEAM WAS REPLACED IAW MM 20-50-02.SDR 00FDEA00026Floorbeam · corrodedNR 705 - CORROSION (C53-224-01(1)) ON UPPER CHORD OF FLOORBEAM AT BS 620 BL0- LBL 24, WL 208. REMOVED AND REPLACED PER FEDEX SRM 53-10-8, 53-10-2.SDR DHL200080367CFloorbeam · deterioratedAT C-CHECK, AFT FUSELAGE MAIN CARGO FLOOR SUPPORT ANGLE DETERIORATED BETWEEN STA 1702 AND STA 1710 LBL 12. REMOVED FLOOR SUPPORT ANGLE, FABRICATED AND INSTALLED NEW ANGLE IAW SRM 51-1-8 PG 11-12 AND SRM 53-2-0 PG 2E & 2F. N/R 5489SDR RRXA000033Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND CRACK, FWD LWR CARGO COMPT AT STA 340 RT. TUNNEL FLOOR STRUT BASE CRACKED. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-21 & 51-1-20D & SDR 00FDEA00016Floorbeam · corrodedNR 657 - CORROSION (C53-224-02) ON BS 680 FLOORBEAM WL 208, LBL 10.5 AT FASTENER HOLE. REPAIRED FLOORBEAM PER IAW FEDEX SRM 53-10-8 FIG 8.SDR 00FDEA00015Floorbeam · corrodedCORROSION ON FLOORBEAM UPPER TEE BS 640, RBL 27-52, WL 208.SDR SPAA0000011Floorbeam · crackedDURING C4 CHECK, THE LONGITUDINAL FLOORBEAM WEB WAS FOUND CRACKED, BS 677, LBL 25, 2 BELOW FLOOR LEVEL AT THE LT AILERON QUADRANT CUT-OUT. THE DAMAGE WAS REPAIRED PER BOEING SERVICE BULLETIN 737-57-1139, FIGUR E 5.SDR SPAA0000010Floorbeam · crackedDURING C4 CHECK, THE LONGITUDINAL FLOORBEAM WEB WAS FOUND CRACKED, BS 677, RBL 25, 2 BELOW FLOOR LEVEL AT THE RT AILERON QUADRANT CUT-OUT. THE DAMAGE WAS REPAIRED PER BOEING SERVICE BULLETIN 737-57-1139, FIGURE 5.SDR DHL200080305CFloorbeam · brokenAT C-CHECK, AFT FUSELAGE MAIN CARGO FLOOR SUPPORT ANGLE BROKEN 1 AT STA 1746 BY L-26. REMOVED DAMAGED AREA AND INSTALLED DOUBLER REPAIR PER SRM 53-2-0.SDR COMA0060021Floorbeam · crackedFLOOR SUPPORT WEB P/N 601R31113-37 AT RBL27 FS 349.0 TO FS 364 IS CRACKED .50. PERFORMED A MAJOR REPAIR BY REPLACING CRACKED FLOOR SUPPORT WEB P/N 601R31113-37 AT RBL 27 FS 349.0 - FS 364 IAW WVAC E.O 601R-53-0789.SDR DHL2000707004Floorbeam · misdrilledWHILE ACCOMPLISHING MODIFICATION AT FLOORBEAM MAIN CARGO DOOR LOWER SILL BEAM JOINT, FOUND NUMEROUS PLUGS HOLES AT ALL FLOORBEAM ATTACH JOINTS UNDER ATTACH ANGLES. REPAIRED FLOORBEAM LOWER SILL JOINTS PER ALTAIR HOLDINGS DRAWING 727021032. 10 X 8 ( 25 EA)N/RSDR RRXA000019Floorbeam · crackedDURING A MAINTENANCE VISIT FOUND CRACK, FWD LWR CARGO COMPT AT STA 340, LONGERON 27 RIGHT, FLOOR BEAM STRUT CRACKED. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED PART AND INSTALLED IAW DC-8 SRM 51-1-21 & 51SDR 20000425SH026Floorbeam · misdrilledFOUND DURING SCHEDULED B-CHECK SERVICE CHECK AND ''G9'' BULKHEAD INSTALLATION, CABIN FLOORBEAM BS 344 UPER CAP HAS ELONGATED HOLES. SUBMITTER STATED HOLES MISDRILLED DURING PREVIOUS MODIFICATION. (X)SDR UPS00831708Floorbeam · corrodedINSPECTION TYPE:C123 FLOORBEAM FS 1660 INBD AFT ENTRY DOOR HAS CORROSION. FABRICATED REPAIR ANGLE AND FILLER IAW REO G07052. INSTALLED REPAIR IAW REO G-07052 AND DC8 SRM 51-1-20D.SDR TWAA0001303Floorbeam · corrodedDURING CHECK-C MAINT IN THE MID CARGO BIN AT STA 522 TO 788, RT SIDE, NUT PLATE HOLES WERE CORRODED ON FLOOR TRACK. INSTALLED NEW FLOOR TRACK PER SRM 51-01, PAGE 1 PARA C, AND TWA SPM 6-70-01, PAGE 3 PARA B, FROM STA 427 TO 636, AND 693 TO 788.SDR CALA0000027Floorbeam · dentedINSPECTION FOUND ABB LOWER SIDE OF MAIN CABIN FLOORBEAM DENTED AND CREASED FROM CARGO DOOR LOWER FLANGE AT STA 1174. REPAIRED IAW SRM 53-05, FIGURE 86.SDR CALA0000026Floorbeam · tornINSPECTION FOUND FLOORBEAM WEB TORN AT UPPER FLANGE AT STA 312, BL 0 TO LBL 20. REPAIRED IAW ECRA 5310-03972.SDR AWXA0000009Floor Beam · corrodedC-CK CORROSION LEVEL 1 NR 5279333, CORROSION OUT OF LIMITS ON FLOORBEAM AT FS 947 UPPER SURFACE AND IN THE FASTENER HOLES FROM LBL 12 TO RBL 8. REMOVED DAMAGED SECTION FROM LBL 15.5 - RBL 11. FABRICATED REPLACEMENT OF BAC 1505-100617, 7075T73 R NR 67226 IAW SDR DHL200071714DFloorbeam · crackedAT D CK, FLOOR SUPPORT IS CRACKED AT BS 672 RBL 60. REMOVED FLOOR SUPPORT. REPLACED FLOOR SUPPORT AT BS 672 RBL 60, PER B727 SRM 51-30-2, MATERIAL USED; 7075T6, SIZE; 9 BY 3, THICKNESS; .080. ALSO, REPLACED T-CLIP ON FLOOR SUPPORT, MATERIAL 7075T6, SIZE; 2 SDR DHL200071705DFloorbeam · damagedAT D CK, FS 640 FLOORBEAM AT WBL 208 RBL 25-45 AREA OF DEEP SCRATCH AND BLENDINGS. CUT OUT DAMAGED AREA FROM FS 640 FLOORBEAM AT WBL 208 RBL 65 TO LBL 25 PER SRM 53-10-8 FIG 3 SHEET 1 STEP 3. INSTALLED FLOORBEAM UPPER CHORD REPAIR AS PER SRM 53-10-8, FIG 3. SDR AWXA0000008Floorbeam · corrodedC-CK CORROSION, LEVEL 1 REF NR 5279355, FLOORBEAM AT FS 986 UPPER AND LOWER SURFACE HAS CORROSION AND BARE METAL, ALSO IN FASTENER HOLES FROM LBL 8 1/4 TO LBL 44, OUT OF LIMITS. REMOVED FLOORBEAM UPPER CHORD FS 986 RBL 50 TO LBL 50 IAW 737 SRM 53-00-51. FABRSDR AWXA0000007Floorbeam · corrodedC-CK CORROSION LEVEL 1 REF NR 5279394 FLOORBEAM FS 967 RBL 46-49 WENT OUT OF LIMITS ON NR 5281013. CUT OUT TOP FLANGE IAW 737 SRM 53-00-51 STR 967, FABRICATED T CAP FROM BAC 1505-100617, 707C-TB R672766 IAW 737 SRM 53-00-51. TREATED AND PRIMED IAW 737 SRM51-SDR USAA991506Floorbeam · corrodedCLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 1 INCH AREA OF CORROSION ON FLOORBEAM STATION 344, BL 0 UPPER CHORD, CORROSION LEVEL 2. SPLICED IN NEW T-CPA PER SRM 53-10-51 FIG 205. (M)SDR USAA991423Floorbeam · corrodedCLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH AT 3 AREAS UPPER CHORD TOP SURFACE BS 312, LBL 12 - RBL 24. FLOORBEAM CORROSION LEVEL 2. INSTALLED T-CAP PER SRM 53-10-51. (M)SDR USAA991431Floorbeam · corrodedCLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY .05 INCH AREA OF CORROSION ON FLOORBEAM STATION 344, LBL 9.5 UPPER CHORD OF T-CAP. CORROSION LEVEL 1. SPLICED IN NEW T-CAP PER SRM 53-10-51 FIG 205. (M)SDR USAA991430Floorbeam · corrodedCLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 1 INCH BY .05 INCH AREA OF CORROSION ON FLOORBEAM STATION 344, RBL 2.5 AFT EDGE OF T-CAP. CORROSION LEVEL 1. SPLICED IN NEW T-CAP PER SRM 53-10-51 FIG 205. (M)SDR AALA2000199Floorbeam · corrodedTUL - CORROSION ON LOWER SIDE OF UPPER CORD OF FLOORBEAM RBL 15 - RBL 19, AROUND NUTPLATES. SM 1309. REMOVED CORROSION PER SRM 51-10-3, ALODINED, PRIMED, REPAIRED FLOORBEAM RBL15 - RBL 19 PER SRM 53-03 FIG 20A AND AARD 51-60-00-05. TST: 44,359 HOURS. CYCLSDR UPS00431759Floorbeam · corrodedINSPECTION TYPE:C 44, CORROSION ON LOWER CHORD FOR LONGITUDINAL FLOORBEAM WEB AT BS 1040 TO 1050, RBL 98. REPAIR ACCOMPLISHED IAW QUERY NOTE 21/2000 AND APPROVED 8110-3. REF EFN 747-57-0481.SDR TWAA0000915Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION ON FLOOR SUPPORT RAIL AT STA 446, WAS BLENDED OUT OF LIMITS. FABRICATED 40 IN SECTION USING OLD FLOOR SUPPORT AS TEMPLATE. INSTALLED WITH RIVETS USING DOUGLAS DRAWING 5956026 FOR SPECS.SDR GAIA0011Floorbeam · damagedDURING PHASE-IN INSPECTION, DAMAGE WAS FOUND ALONG CABIN FLOORBEAM SUPPORT BS 400, RIGHT BODY LINE 55. INSTALLED REPAIR AT CABIN FLOORBEAM SUPPORT BS 400, RBL 55. MATERIAL USED, PART NR BAC1505-100617 AND BAC1490-2831, T-ANGLE 15 INCH LONG, SUPPORT ANGLES, 1SDR GAIA0009Floorbeam · damagedDURING PHASE-IN INSPECTION, DAMAGE WAS FOUND ALONG FLOORBEAM UPPER T-CAP AT STATION 344 LEFT BODY LINE 62.5 TO RT BODY LINE 62.5. REPLACED FLOORBEAM UPPER T-CAP AT STATION 344, LBL 62.5. MATERIAL USED, PART NR BAC1505-29222. REPAIR ACCOMPLISHED IAW SRM 53-1SDR CALA0000019Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT STA 328, LBL 30 AND BL 0 TO RBL 1. THE CORRODED SECTIONS OF FLOORBEAM WERE REMOVED AND REPLACED IAW SRM 53-10-51.SDR 00FDEA00027Seat Track · crackedSNRM 159 - MAIN DECK - SEAT TRACK FOUND CRACKED AT BS 970.5 X = 47.5 RT CRACK LENGTH APPROX 2 INCHES. REPAIRED SEAT TRACK PER SRM 53-70-00 VOL 1.SDR DHL2000707003Floorbeam · damagedFLOORBEAM REPAIR AT BS 620 RBL 35 TO RBL 62 NOT PER SRM. REPLACED FLOORBEAM REPAIR PER SRM 53-10-8, 4 FT 6 INCHES.SDR DHL2000707002Floorbeam · damagedFLOORBEAM REPAIR AT BS 620, RBL 23 TO RBL 32 NOT PER SRM. REPLACED FLOOR BEAM PER SRM 53-10-8, 4 FT 6 INCH LENGTH.SDR ABXA000177Floorbeam · crackedCRACK IN FLOORBEAM AT RBL 20 AND STATION 246. REPAIRED IAW 767 SRM 51-70-13.SDR USAA991493Floorbeam · corrodedCLT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND A 2 INCH BY 1 INCH AREA OF CORROSION AT BS 328, RBL 19 FLOORBEAM. CORROSION LEVEL 1. INSTALLED T-CAP PER SRM 53-10-9. (M)SDR USAA991487Floorbeam · crackedCLT - DURNG Q-1 CHECK VISUAL INSPECTION, FOUND A 3 INCH CRACK STATION 663, BL 0 FLOORBEAM. INSTALLED DOUBLER PER TR 57-10-04. (M)SDR USAA991485Floorbeam · corrodedCLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND CORROSION 17 INCHES TOP OF FLOORBEAM STATION 986, RBL 7-11, CORROSION LEVEL 1. REPLACED T-CAP PER SRM 5. (M)SDR USAA991484Floorbeam · corrodedCLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND CORROSION STATION 1006, LBL 29 FLOORBEAM, CORROSION LEVEL 1. REPLACED T-CAP PER SRM 53-10-09 FIG 7. (M)SDR USAA991474Floorbeam · corrodedCLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 34 INCH AREA OF CORROSION STATION 294.5, LBL 13 TO RBL 21 FLOORBEAM, CORROSION LEVEL 2. REPAIRED PER TR 53-10-04B. (M)SDR USAA991464Floorbeam · corrodedCLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND A 2 INCH AREA OF CORROSION AT BS 794.3, STRINGER 26R FLOOR SUPPORT BEAM, CORROSION LEVEL 2. INSTALLED NEW FLOOR SUPPORT SECTION PER SRM 53-10-05. (M)SDR RRXA003383Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ON THE FLOOR BEAM AT STA 340 AND RBL -12-48, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR PART IAW DC-8 SRM 53-2-0.SDR RRXA003353Floorbeam · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR BEAM AT STA Y900 TO Y920, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0 FIG 1F, 53-1-0 AND DC-8 DSDR SWAA000046Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAM UPPER SURFACE CORRODED, BS 328, RBL 32-42. REPAIRED BEAM PER SRM.SDR TWAA0000909Floorbeam · corrodedDURING OP 16 MAINT CHECK IN THE FORWARD CARGO COMPARTMENT, FOUND CORROSION AROUND NUT PLATE HOLES ON FLOOR SUPPORT BETWEEN FLOOR TRACKS STA 437. REPLACED CORRODED FLOOR SUPPORT WITH NEW FLOOR SUPPORT PER SPM 6-70-01.
Back to JASC 5315