SDR C2XA99IA611Floorbeam · corrodedDURING CONTINENTAL EXPRESS C-CHECK, FOUND FLOOR CROSSBEAM AT FRAME 38 CORRODED. REMOVED AND REPLACED CROSSBEAM IAW SRM 51-40-02. AIRCRAFT APPROVED FOR RETURN TO SERVICE. (M)SDR SWAA991918Beam · corrosionDURING SCHEDULED 1/4D CHECK, FOUND CORROSION ON FLOORBEAM UPPER SURFACE, BS 344. REMOVED AND REPLACED UPPER T-CAP FROM RBL 38 TO LBL 67 PER SRM.SDR 99T64R679EWAFloorbeam · corrodedFOUND DURING D-CHECK, TWO NUT PLATES BROKEN OFF AND CORROSION AROUND HOLES ON UNDER SIDE OF FLOORBEAM STATION 760 BETWEEN SEAT TRACKS NR 6 AND NR 7. REMOVED CORROSION BY MECHANICAL METHOD. TREATED AND PRIMED. IT IS ACCEPTABLE TO RETURN TO SERVICE PER EO NR SDR RRXA000220Floorbeam · corrodedDURING MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOORBEAM AT STA 760 BETWEEN SEAT TRACKS NR 6 & NR 7. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REMOVED CORROSION BY MECHANICAL METHOD. RETURNED TO SERVICESDR TWAA0000416Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND FLOORBEAM CAP CORRODED AT APPROX STA 325, LBL 52. INSTALLED A FLOORBEAM UPPER CHORD REPAIR PER SRM 53-00-51, FIG 201 SHEET 3.SDR COMA9960723Floorbeam · corrodedTOP PLATES AT FS 349.00 CORRODED BEYOND LIMITS. REPLACED CORRODED PLATES WITH NEW PLATES IAW WVAC EO 601R-53-0640.SDR USAA991204Floorbeam · corrodedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 2 INCH BY 1 INCH MULTIPLE AREA OF CORROSION AT BS 986.5, RBL 44 - LBL 45, FLOORBEAM T-CAP. CORROSION LEVEL 2. REPLACED FLOORBEAM T-CAP PER TR 53-60-01 AND SRM 53-00-51 FIG 202. (M)SDR USAA991159Floorbeam · corrodedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND .25 INCH AREA OF CORROSION AT STATION 312, LBL 21 TO RBL 22 FLOORBEAM. CORROSION LEVEL 2. CORROSION TASK NR C53-107-02. SPLICED IN NEW CAP SECTION PER SRM 53-10-51. (M)SDR USAA991157Floorbeam · corrodedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .500 INCH WIDE AREA OF CORROSION AT STATION 360, CORROSION LEVEL 2. INSTALLED STRAP PER SRM 53-00-51. (M)SDR EISA99226Floorbeam · corrodedACCOMPLISHMENT OF ROUTINE C-CHECK WORK CARD REVEALED CORROSION ON BS 1030 FLOORBEAM T-CAP AT BL ZERO. REMOVED CORROSION AND MATERIAL LOSS OF LIMITS PER SRM 53-10-3. FABRICATED AND INSTALLED REPAIR PER SRM 53-10-8. TT: 65,345:17 HOURS. TC: 43,816. (X)SDR DHL99708007Floorbeam · misrepairedFLOORBEAM STABILITY STRAP REPAIR AT BS 380 BL 0 DID NOT CONFORM TO SRM. REPLACED SECTION OF STRAP PER SRM 53-10-8, 3 X 63.SDR AT9900843Floorbeam · chafedFOUND FLOORBEAM CHAFED 8 INCH AREA AT BS 870 BETWEEN LBL 5 - LBL 15, CHAFED AREA OUT OF LIMITS. FABRICATED AND INSTALLED REPAIR ANGLE AND STAINLESS STEEL WRAP STRIP IAW DC9 SRM 53-05 FIGURE 20A.SDR 99UAL900596Floorbeam · crackedDISCOVERED A CRACK OF APPROXIMATELY 1.0 INCH AT RBL 46 ON THE FLOORBEAM AT BS 927. THE CRACK LOCATED IN THE RADIUS OF THE WEB AND THE UPPER CAP OF THE I-BEAM. *S/D* REPAIRED THE CRACK BY STANDARD FLOORBEAM SHEET METAL REPAIRS PER 737 SRM.SDR TWAA9917613Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION ON TOP OF CABIN FLOOR PANEL ATTACH ANGLE, STA 180, RBL 0 TO 44 IN. REMOVED CORROSION PER SPM 6-80-01. REINSTALLED SUPPORT PER SPM 6-30-07. TREATED PER SRM 51-10-3.SDR TWAA9917604Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION ON CABIN FLOOR ATTACH ANGLE, STA 160, RBL 0 TO 53 IN. REMOVED AND REPLACED FLOOR SUPPORT PER SPM 6-70-01.SDR TWAA9917603Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION ON TOP OF CABIN FLOOR PANEL ATTACH ANGLE, STA 160, LBL 0 TO 13 IN. REMOVED AND REPLACED FLOOR SUPPORT PER SPM 6-70-01.SDR TWAA9917602Floorbeam · corrodedDURING OP 16 MAINT CHECK, FOUND LIGHT CORROSION ON CABIN FLOOR SUPPORT ANGLE AT BL 0, STA 216 TO 229. REMOVED AND REPLACED FLOOR SUPPORT ANGLE PER SPM 6-70-01.SDR TWAA9917601Floorbeam · corrodedDURING OP 16 MAINT CHECK AT STA 160 TO 220 FOUND CABIN FLOOR PANEL ATTACH ANGLE WITH CORROSION. REMOVED AND REPLACED FLOOR SUPPORT PER SPM 6-70-01.SDR SWAA991895Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND CORROSION ON FLOORBEAM BS 312, LBL 1- RBL 21. REPAIRED BEAM PER TYPICAL REPAIR NR TI-353-007.SDR QXEA9902389Floorbeam · corrodedPDX - MINOR PITTING CORROSION ON TOP OF FLOORBEAM 600L BETWEEN FRAME 3820 AND 4610. REPAIRED IAW FOKKER SRM 51-10-04, PAGE 9.SDR P2EA99329Floorbeam · crackedSJO - DURING C-CHECK, FLOORBEAM LOWER CHORD CRACKED AT BS 707, BL 0 AND WL 202. REPAIRED FLOORBEAM LOWER CHORD FROM BS 700 TO BS 713 IAW COOPESA EO NR COO-3-57-643-99, DATED 11/11/99. (M)SDR P2EA99328Floorbeam · crackedSJO - DURING C-CHECK, FLOORBEAM LOWER CHORD CRACKED AT BS 695, LBL 45.5 AND WL 202. REPAIRED FLOORBEAM LOWER CHORD FROM BS 688.5 TO BS 700 IAW COOPESA EO NR COO-3-57-643-99, DATED 11/11/99. (M)SDR P2EA99327Floorbeam · crackedSJO - DURING C-CHECK, FLOORBEAM LOWER CHORD CRACKED AT BS 674, LBL 45.5 AND WL 202. REPAIRED FLOORBEAM LOWER CHORD FROM BS 668 TO BS 681 IAW COOPESA EO NR COO-3-57-643-99, DATED 11/11/99. (M)SDR P2EA99326Floorbeam · crackedSJO - DURING C-CHECK, FLOORBEAM LOWER CHORD CRACKED AT BS 706, LBL 24.5 INCH AND WL 202 INCH. REPAIRED FLOORBEAM LOWER CHORD FROM BS 698 TO BS 714 IAW COOPESA EO NR COO-3-57-643-99, DATED 11/11/99. (M)SDR P2EA99325Floorbeam · crackedSJO - FLOORBEAM LOWER CHORD CRACKED AT BS 706, RBL 24.5 INCH AND WL 202 INCH. REPAIRED FLOORBEAM LOWER CHORD FROM BS 701 TO BS 712.5 IAW COOPESA EO NR COO-3-57-643-99, DATED 11/11/99. (M)SDR P2EA99324Floorbeam · crackedSJO - DURING C-CHECK, FLOORBEAM LOWER CHORD CRACKED AT BS 695, RBL 45.5 INCH AND WL 202 INCH. REPAIRED FLOORBEAM LOWER CHORD FROM BS 689.5 TO BS 701.5. (M)SDR P2EA99323Floorbeam · crackedSJO - DURING C-CHECK, FLOORBEAM LOWER CHORD CRACKED AT BS 673, RBL 45.5 INCH AND WL 20 INCH. REPAIRED FLOORBEAM LOWER CHORD FROM BS 667.5 TO BS 683. (M)SDR P2EA99320Floorbeam · crackedSJO - DURING C-CHECK, FLOORBEAM CRACKED AT BS 707, BL 0 AND WL 204. REPAIRED FLOORBEAM FROM BS 698 AND BS 717 IAW SERVICE BULLETIN 737-57-1210 PART III FIG 5, DATED APRIL 4, 1999. REPAIRED IN CONJUNCTION WITH NON-ROUTINE 697. (M)SDR P2EA99319Floorbeam · crackedSJO - DURING C-CHECK, FLOORBEAM WEB CRACKED AT BS 712, BL 0 AND WL 204 INCH. REPAIRED FLOORBEAM FROM BS 698 AND BS 717 IAW SERVICE BULLETIN 737-57-1210 PART III FIG 5. REPAIRED IN CONJUNCTION WITH NON-ROUTINE 700. (M)SDR P2EA99318Floorbeam · crackedSJO - DUIRNG C-CHECK, FLOORBEAM LOWER CHORD CRACKED AT BS 727, WL 202 INCH AND LBL 24.5 INCH. REPAIRED FLOORBEAM LOWER CHORD FROM BS 721.5 TO BS 738.5 IAW SERVICE BULLETIN 737-57-1210, PART III FIG 7, DATED APRIL 4, 1991. (M)SDR P2EA99317Floorbeam · crackedDURING C-CHECK, FLOORBEAM LOWER CHORD CRACKED AT BS 726, BL 0 AND WL 202 INCH. REPAIRED FLOORBEAM LOWER CHORD FROM BS 721 TO BS 738 IAW SB 737-57-1210, PART III FIG 7, DATED APRIL 4, 1991. (M)SDR P2EA99316Floorbeam · crackedSJO - DURING C-CHECK, FLOORBEAM CRACKED AT BS 727, WL 202 INCH AND RBL 24.5. REPAIRED FLOORBEAM BETWEEN BS 721 AND BS 737 IAW SERVICE BULLETIN 737-57-1210, PART III FIG 7, DATED APRIL 4, 1991. (M)SDR ASAA9980256Floorbeam · corrodedPHX - DURING 30K CHECK, FOUND CORROSION ON FLOOR SUPPORT ANGLE AT FS 180, FROM RBL 6 TO RBL 38. REMOVED DAMAGED MATERIAL AND INSTALLED NEW PIECES IAW DC9 SRM 53-01 AND 53-14-01. (M)SDR ABXA9900803Fitting · crackedDURING D-CHECK, FOUND RIGHT VERTICAL SUPPORT FITING CRACKED IN TWO PLACES AT STATION 832. REPLACED FITTING IAW DC9 SRM 51-30-1 AND 51-30-2.SDR ABXA9900802Fitting · crackedDURING D-CHECK, FOUND RIGHT VERTICAL SUPPORT FITTING CRACKED AT STATION 332. REPLACED FITTING IAW DC9 SRM 51-30-2 AND 51-30-5.SDR ABXA9900801Fitting · crackedDURING D-CHECK, FOUND LEFT VERTICAL SUPPORT FITTING CRACKED AT STATION 794. REPLACED FITTING IAW DC9 SRM 51-30-2 AND 51-30-5.SDR DHL99708014Floorbeam · corrodedBS 480 FLOORBEAM CORROSION LOWER SIDE OF UPPER CAP FWD SIDE OF LBL 45. CUT OUT DAMAGED AREA AT STA 480 RBL 35, INSTALLED FLOORBEAM REPAIR FROM RBL 35 TO 65 PER SRM 53-10-8.SDR DHL99708013Floorbeam · misrepairBS 680 FLOORBEAM REPAIR UPPER CHORD OF LBL 6 TO 30 DID NOT CONFORM TO SRM. CUT OUT DAMAGED AREA. INSTALLED FLOORBEAM REPAIR BETWEEN LBL 36 AND 12 PER SM 53-10-8.SDR DHL99708012Floorbeam · misrepairBS 660 FLOORBEAM REPAIR UPPER CHORD OF RBL 14 TO RBL 22 DID NOT CONFORM TO SRM. CUT OUT DAMAGED AREA FROM RBL 16 TO 36. INSTALLED FLOORBEAM REPAIR PER SRM 53-10-8.SDR DHL99708011Floorbeam · corrodedBS 360 FLOORBEAM CORRODED ON UPPER CHORD FLANGE RBL 30. CUT OUT DAMAGED AREA FROM RBL 24 TO RBL 68. INSTALLED FLOORBEAM PER SRM 53-10-8.SDR DHL99708010Floorbeam · misrepairBS 620 FLOORBEAM REPAIR UPPER CHORD FROM LBL 2 TO 31 DID NOT CONFORM PER SRM. CUT OUT DAMAGED UPPER CHORD, INSTALLED FLOORBEAM REPAIR PER SRM 53-10-8.SDR DHL99708002Floorbeam · corrodedBS 560 FLOOR BEAM UPPER CHORD HAS FLOOR BEAM REPAIR AND CORROSION FROM LBL 4 TO LBL 14.REMOVED OLD REPAIR AND INSTALLED NEW REPAIR PER SRM 53-10-8 , SUPPORT ANGLE 11 , AND 7 N/R 3885SDR UPS99231069Floorbeam · corrodedINSPECTION TYPE:SI LOWER FLANGE OF BS 600 FLOORBEAM CORRODED BL 0-RBL 25 WL 200 CORROSION CLEAN UP BEYOND ACCEPTABLE LIMITS. REMOVED AND REPLACED LOWER CHORD LBL 18 TO RBL 31 PER ER 99-6268 AND SRM 53-10-1.SDR TWAA9915803Floorbeam · corrodedDURING CHECK-C MAINT THE FORWARD GALLEY FLOOR FRAME WAS FOUND CORRODED AT STA 200, RBL 6 IN TO RBL 42 INCHES. REMOVED FLOORBEAM AND FABRICATED PART FROM TWA STOCK. ALODINED AND PAINTED. REINSTALLED FLOORBEAM WITH RIVETS AND ORIGINAL HI-LOKS PER SPM 6-70-01.SDR TWAA9915802Floorbeam · corrodedDURING CHECK-C MAINT, THE FORWARD GALLEY FLOORBEAM WAS FOUND CORRODED AT STA 180, RBL 6 IN TO RBL 40 INCHES. REPLACED THE PART PER SPM 6-70-01, PAGE 2.SDR F3LA99155Floorbeam · corrodedDEN - DURING C-7 CHECK INSPECTION, REPORTED CORROSION ON TOP CAP OF FLOORBEAM 344. MAINTENANCE FABRICATED REPLACEMENT PARTS AND REPAIRED PER SRM 53-10-9, FIG 1, AND SRM 53-10-2 FIG 7. (M)SDR F3LA99154Floorbeam · corrodedDEN - DURING C-7 CHECK, INSPECTION REPORTED CORROSION ON TOP CHORD OF FLOORBEAM 328, BBL 0 TO 50 INCHES RT. MAINTENANCE FABRICATED REPLACEMENT PARTS AND REPAIRED PER SRM 53-10-0, FIG 7 AND SRM 53-10-2, FIG 7 DETAIL 1. (M)SDR F3LA99153Floorbeam · corrodedDURING C-7 CHECK, INSPECTION REPORTED CORROSION ON TOP CHORD OF FLOORBEAM 328, BBL 6-12 LT. MAINTENANCE FABRICATED REPLACEMENT PARTS AND REPAIRED PER SRM 53-10-9 FIG 1. (M)SDR F3LA99152Floorbeam · corrodedDEN - DURING C-7 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM 312, BBL 0 TO RT SIDE END. MAINTENANCE FABRICATED REPLACEMENT PARTS AND REPAIRED PER SRM 53-10-9, FIG 7, AND SRM 53-10-2, DETAIL 1, FIG 7. (M)SDR F3LA99151Floorbeam · corrodedDEN - DURNG C-7 CHECK, INSPECTION REPORTED CORROSION ON FLOORBEAM CAP 312, BBL 0 TO BBL 16. MAINTENANCE FABRICATED REPLACEMENT PARTS AND REPAIRED PER SRM 53-10-9, FIG 7, AND SRM 53-10-2, DETAIL 1, FIG 7. (M)
Back to JASC 5315