SDR SWAA961379Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOORBEAM CORROSION AT BS 294 RBL 145, WL 208 AND AT BS 328 RBL 21.5 AND 35. REPAIRED PER BOEING SRM.SDR SWAA961364Floorbeam · dentedDURING SCHEDULED D-CHECK, FOUND FLOORBEAM DENTED AT BS 519, LBL 8, WL 156. REPAIRED PER BOEING SRM.SDR CALA9601905Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AT FORWARD ENTRY BS 344 AND CORROSION WAS FOUND ON FLOORBEAM AT BS 344 FROM CENTERLINE TO LT SIDE WALL. THE FLOORBEAMS WERE REMOVED AND REPLACED IAW SRM 53-10-51.SDR P2EA97019Floorbeam · corrodedPAE - FOUND DURING VISUAL INSPECTION, 105 INCHES BY 2 INCHES OF CORROSION ON FLOORBEAM AT BS 328. AREA PREVIOUSLY REWORKED. REMOVED, FABRICATED, AND INSTALLED NEW FLOORBEAM PER SRM 53-10-09. (M)SDR P2EA97018Floorbeam · corrodedPAE - FOUND DURING VISUAL INSPECTION, 81 INCHES BY 2 INCHES OF CORROSION ON FLOORBEAM AT BS 294. AREA PREVIOUSLY REWORKED. REMOVED DAMAGED UPPER CHORD OF BS 294 FLOORBEAM AND INSTALLED EXTRUSION AN 101362404. (M)SDR P2EA97017Floorbeam · corrodedPAE - FOUND DURING VISUAL INSPECTION, 85 INCHES BY 2 INCHES OF CORROSION ON FLOORBEAM AT BS 312. AREA PREVIOUSLY REWORKED. REPAIRED UPPER FLOORBEAM CHORD BY REMOVING UPPER CHORD AND REPLACING WITH EXTRUSION REPAIR PER SRM 53-10-9 FIG 5. MODIFIED PART INSTALLSDR P2EA97016Floorbeam · corrodedPAE - FOUND DURING VISUAL INSPECTION, 81 INCHES BY 2 INCHES OF CORROSION ON FLOORBEAM AT BS 294 LBL 32 TO RBL 49 WL 608. AREA PREVIOUSLY REWORKED. REMOVED DAMAGED SECTION OF CHORD, FABRICATED AND INSTALLED NEW CHORD PER SRM 53-10-9 FIG 5. (M)SDR P2EA97015Floorbeam · corrodedPAE - FOUND DURING VISUAL INSPECTION, 105 INCHES BY 2 INCHES OF CORROSION ON FLOORBEAM AT RBL 11 TO RBL 45 WL 208 BS 328. AREA PREVIOUSLY REWORKED. REMOVED AND FABRICATED NEW CHORD LBL 60 TO RBL 60 BS 328 PER SRM 53-10-09. (M)SDR CALA9601772Floorbeam · corrodedINSPECTION FOUND FLOORBEAM UPPER T-CAP CORRODED AT STA 328, RBL 10 TO RBL 46. THE UPPER T-CAP WAS REMOVED, A NEW UPPER T-CAP WAS FABRICATED AND INSTALLED IAW SRM 53-10-2 AND 51-30-2.SDR AWXA9600763Floorbeam · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON BS 1016 FLOORBEAM ON UPPER CHORD LBL 7 TO RBL 39, WL 208. REPAIRED BS 1016 FLOORBEAM UPPER CHORD PER ER 2-53-15-53. ER REF TCO-PAN-96-1738RR 8110-3.SDR AWXA9600762Floorbeam · crackedDURING ROUTINE MAINTENANCE CHECK, FOUND CRACK FROM STOP DRILL HOLE OUTBOARD BS 520, LBL 24.75, WL 208. STOP DRILLED CRACK FROM HOLE WL 208, LBL 24.75. NDI VERIFICATION OF CRACK CONTAINMENT PER D6-37239.6. REPAIRED FLOORBEAM BS 520 PER EO 53-14-12 AND SB 737SDR RAAA96E4017Floorbeam · brokenDURING SCHEDULED NR 3 CHECK, FOUND FS 135 FLOORBEAM UPPER CHORD BROKEN AT FASTENER HOLE AT LBL 40. REPAIRED PER SRM 51-3-8, FIG 1.SDR C2XA96IA296Floor Beam · corrodedIAH - DURING C-CHECK INSPECTION, FRAME 36 FLOOR BEAM WAS FOUND TO BE CORRODED. MAINTENANCE REPAIRED THE FLORO BEAM USING A SPLICE, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)SDR TAOA129602Floor Beam · crackedC-2 CARGO DOOR BUNGEE TORQUE SHAFT ATTACHMENT BRACKET AT FLOOR BEAM FLANGE HAS 6.5 INCH CRACK AT STATION 950E. PERFORMED CABIN FLOOR BEAM REPAIR AT STATION 950E, REPAIRED LOWER FLANGE IAW STRUCTURAL REPAIR MANUAL CHAPTER 53-10-8. REPLACED AFT CARGO DOOR FORWSDR AALA970114Floorbeam · corrodedTUL - BS 380 RBL 45 - RBL 70, CORROSION ON TOP FLANGE OF FLOORBEAM. REPLACED FLOORBEAM TOP CAP PER SRM 53-10-8. (M)SDR AALA970112Floorbeam · corrodedTUL - FLOORBEAM CORRODED STATION 380 RBL 10-40. REPLACED FLOORBEAM TOP CAP PER SRM 53-10-8. (M)SDR AWXA9600761Floorbeam · corrosionDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOORBEAM BS 987, LBL 17 TO RBL 45, WL 208. REPAIRED FLOORBEAM BS 987, LBL 29 TO RBL 55, WL 208 PER EO 2-53-16-46.SDR AWXA9600757Floorbeam · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOORBEAM UPPER CHORD AT BS 294.5, WL 208, RBL 14 TO LBL 2. REPAIRED FLOORBEAM UPPER CHORD IAW, SRM 53-10-51.SDR 97ZZZM404Floorbeam · crackedTHREE FLOORBEAMS ARE CRACKED AT FRAME 29 BEAM 3, 13 AND 19. REPAIRED CRACKS IAW BAE DRAWING HC536H9211 AND FAX AIRAMS/T/BAE/25858/96.SDR 97ZZZM25Floor Beam · corrodedDURING SCHEDULED INSPECTION AT AERO CORP IN LAKE CITY, FL, FOUND CORROSION ON THE UPPER CAP OF THE FLOOR BEAM STA 965, LBL 48. RECEIVED FROM AERO SUPPLY L-ANGLE NR 635060. FIT, TRIMMED, DRILLED UP, DEBURRED ANGLE IAW DC9 SRM 53-11-3 FIG 11A, SRM 51-10-4. TRSDR SWAA961311Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOORBEAM CORRODED ON UPPER FLANGE AT BS 344, RBL 10 TO LBL 54, WL 208. REPAIRED PER BOEING SRM.SDR SWAA961310Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOORBEAM CORRODED ON UPPER FLANGE AT BS 328, RBL 12 TO RBL 58, WL 208. REPAIRED PER BOEING SRM.SDR SWAA961309Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOORBEAM CORRODED ON UPPER FLANGE AT BS 312, LBL 8 TO RBL 55, WL 208. REPAIRED PER BOEING SRM.SDR SWAA961305Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOORBEAM CORRODED ON UPPER CHORD AT BS 294, WL 208. REPLACED UPPER T-CHORD PER BOEING SRM.SDR SWAA961304Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOORBEAM CORRODED ON UPPER CHORD AT BS 947, RBL 20 TO RBL 54, WL 208. REPAIRED PER BOEING SRM.SDR SWAA961303Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOORBEAM CORRODED ON UPPER CHORD AT BS 967, RBL 27.5 TO LBL 55, WL 208. REPAIRED PER BOEING TI T1-A53-014.SDR SWAA961302Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOORBEAM CORRODED ON UPPER CHORD AT BS 986 RBL 45 TO LBL 18, WL 208. REPAIRED PER EWO 96-0709.SDR SWAA961301Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOORBEAM CORRODED AT BS 986, LBL 43, WL 208. REPAIRED PER EWO 96-0709.SDR CALA9601729Floorbeam · corrodedINSPECTION FOUND CORROSION UNDER CASTING ON FLOORBEAM WEB AT STA 1338, LBL 45 TO LBL 54. THE CORROSION WAS REMOVED AND A DOUBLER WAS INSTALLED IAW ECRA 5310-03372.SDR USAA960756Floor Beam · corrosionCLT - INSPECTION VISUALLY FOUND LEVEL 2 CORROSION AROUND VARIOUS CLIPNUT HOLES UPPER 'T' CAP OF STATION 312, BL 0 TO RBL 40, STATION 312. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. INSTALLED NEW 'T' CAP REPAIR/REPLACEMENT AS PER USAIR TYPICAL REPAIR 53SDR USAA960755Floor Beam · corrosionCLT - INSPECTION VISUALLY FOUND LEVEL 2 CORROSION MEASURING 1 INCH BY 1 INCH LOCATED AT FLOOR BEAM FLANGE STATION 328, STATION 528 LBL 13 AND AT LBL 49. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. APPLIED FILLER 'T' AND SPLICE ANGLE AS PER USAIR TYPICALSDR 9627776608Floorbeam · corrodedDURING PERIODIC CHECK, FOUND CORROSION ON FLOORBEAM AND RIGHT OUTBOARD SUPPORT ANGLE. REMOVED CORROSION, FABRICATED AND INSTALLED .071 FILLER AND .063 7075-T6 STRAP DOUBLER PER EA 66-120474.SDR RAIA961144Floor Beam · corrosionSTL - FOUND CORROSION ON FLOOR BEAM 36 AT STRINGER 17L AND 17R. MX REPLACED BEAM 36 WITH NEW OEM UNIT. (M)SDR RAIA961143Floor Beam · corrosionMX - FOUND CORROSION ON FLOOR BEAM 38 AT STRINGER 17L AND 17R. MX REPLACED NOTED BEAM. (M)SDR GAIA9638Floor Beam · corrodedDURING C-CHECK, INSPECTION REVEALED CORROSION ON FUSELAGE FLOOR BEAM AT STA 642. REPAIRED FLOOR BEAM IAW KITTY HAWK EA D9-53-037. THE AIRCRAFT WAS RETURNED TO SERVICE. (X)SDR AALA961798Floor Beam · gougedAFW - FLOOR BEAM AT STA 412 TO STA 419 AT RBL 45 HAS GOUGE BLENDED. MATERIAL REMAINING IS BEYOND SRM ALLOWABLE LIMITS. REPAIR PER MRB 757-1025. TST: 15,026.39 HOURS. CYCLES, 5,412. (X)SDR UPS96421717Floor Beam · damagedINSPECTION TYPE: C. SEVERAL SMALL HOLES DRILLED IN FLOOR BEAM UPPER CHORD AT BS 380 BETWEEN LBL 61 AND LBL 81. REPAIRED FLOOR BEAM UPPER CHORD ON BS 580 BETWEEN LBL 61 AND LBL 81 ACCORDING SRM 51-40-04 FIG.1.SDR RAIA961142Floor Beam · corrosionSTL - FOUND CORROSION ON FLOOR BEAM 39 AT STRINGER 17L TO 17R. MX REPLACED FLOOR BEAM 39. (M)SDR RAIA961141Floor Beam · corrosionSTL - FOUND CORROSION ON FLOOR BEAM 40 BEAM 40 FROM STRINGER 17L TO 17R. MAINTENANCE REPLACED FLOOR BEAM 40. (M)SDR AWXA9600734Floorbeam · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOORBEAM RBL 55 TO LBL 55, WL 208, BS 986.5. REMOVED, FABRICATED UPPER CHORD AND INSTALLED PER SRM 51-41-02 AND ER 3-53-16-15.SDR AWXA9600733Floorbeam · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND FLOORBEAM BS 967, WL 208, LBL 44 TO 55 CORRODED. INSTALLED REPLACEMENT T-CAP ON FLOORBEAM AND FASTENERS FROM BS 967, WL 208, LBL 44 TO 55 PER SRM 51-40-02.SDR GTIA9700019Floorbeam · crackedMHV - FORWARD CARGO COMPARTMENT FLOORBEAM LOWER LIP BL0 BROKEN OFF AT FS 389 AND FLOORBEAM LOWER LIP AT FS 408 IS CHAFED. REMOVED DAMAGED AREA, FABRICATED FLAT DOUBLERS AND ANGLE DOUBLERS AND INSTALLED IAW 53-10-8. (M)SDR CALA9601747Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED AROUND FASTENER HOLES AT STA 1006, RBL 10. REPAIRED USING DOUBLERS IAW SRM 53-30-51.SDR IXXA9700007Floorbeam · crackedDURING ROUTINE C-CHECK INSPECTION, FLOORBEAM BETWEEN FUSELAGE STATION 226 AND 270 WAS FOUND TO BE CRACKED. REPAIR OF THE FLOORBEAM WAS ACCOMPLISHED BY FABRICATING AND INSTALLING REPAIR DOUBLERS IN ACCORDANCE WITH FAA DER APPROVED SKETCH B68-R29 AND THE DOUGLSDR 97ZZZX1766Floor Beam · corrodedDURING A SCHEDULED INSPECTION AT AERO CORP IN LAKE CITY, FL, STA 997 FL6OR BEAM CHAFED AND CORRODED FROM RBL 48 TO LBL 48. REMOVED FLOOR BEAM ANGLE, INSTALLED NEW ANGLE IAW DC9 SRM'S 53-11-3 FIG 11, 51-10-4, 51-10-3, AND 51-30-2.SDR 96ZZZX6054Floor Beam · corrodedDURING A SCHEUDLED INSPECTION AT AERO CORP, CORROSION WAS FOUND IN THE AFT CARGO PIT CABIN FLOOR BEAM AT STA 996 AT BL 34R. REMOVED CORROSION IAW DC9 SRM 51-10-2. FOUND TO BE OUT OF LIMITS AT LBL 31, 38, 40, 45, AT STA 980 IAW DC9 SRM 53-05 FIG 20A, 50 PERCESDR F3LA96059Floorbeam · corrodedPAE - FOUND CORROSION ON FLOORBEAM AROUND NUTCLIP HOLE AT BS 947, RBL 50, WL 208. BLENDED DAMAGED AREA PER SRM 51-10-02, DAMAGED AREA WAS FOUND TO BE OUT OF LIMITS. FABRICATED A REPAIR STRAP AND TREATED PER SRM 51-20-01. INSTALLED STRAP, ALL WORK ACCOMPLISHSDR ABXA9700242Floorbeam · corrodedDURING C-CHECK, A FLOORBEAM AT STATION 980 RBL 22.0 WAS FOUND CORRODED, NR BF-692. THE FLOORBEAM WAS REPAIRED IAW DC-9 SRM.SDR AALA961828Floorbeam · corrodedTUL - BS 1070 RBL 45.5 HEAVY CORROSION ON TOP LEG OF FLOORBEAM. REMOVED CORRODED PORTION OF FLOORBEAM. INSTALLED NEW PORTION PER SRM 53-10-8. (M)SDR AALA961807Floorbeam · corrodedAFW - FLOORBEAM AT STATION 365 HAS CORROSION REMOVAL ON UPPER SURFACE. MATERIAL REMAINING IS BEYOND ALLOWABLE SRM LIMITS. REPAIRED PER MRB 757-1016. (M)
Back to JASC 5315