SDR AWXA960411Floor Beam · corrodedPAE - FLT 7821 - DURING ROUTINE SCHEDULED C-8 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM AT BS 312, LBL 12, BL 0, RBL 7, WL 208. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 53-10-51. (M)SDR AWXA960410Floor Beam · corrodedPAE - FLT 7821 - DURING ROUTINE SCHEDULED C-8 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM AT BS 294 RBL 15, RBL 45, NL 208. REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 53-10-51. (M)SDR AWXA960409Floor Beam · corrodedDURING ROUTINE SCHEDULED C-8 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM AT BS 344, LBL 15, LBL 42, LBL 48, WL 208. REMOVED DAMAGE. FABRICATED AND INSTALLED REPAIR PARTS PER SRM 53-10-51. (M)SDR C2XA96IA189Floor Beam · corrodedIAH - DURING C-CHECK INSPECTION, FLOOR BEAM 39 WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BEAM, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)SDR C2XA96IA188Floorbeam · corrodedIAH - DURING C-CHECK INSPECTION, FLOORBEAM 38 WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED BEAM, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)SDR DL73S961918Floor Beam · crackedDURING INSPECTION, THE BL 0.07 FLOOR BEAM UPPER CAP OF WING CENTER SECTION IS CRACKED THROUGH AT FS 663. NO CRACKS FOUND IN WEB. THE DAMAGE WAS REPAIRED PER B737S/B 57-1210.SDR AALA961215Floor Beam · corrodedAFW - FOUND AFTER CORROSION REMOVAL, BEAM THICKNESS LESS THAN SRM LIMITS. REPAIR PER MRB 757-901. (M)SDR AALA961212Floor Beam · corrodedAFW - AFTER CORROSION REMOVAL, REMAINING THICKNESS IS BEYOND SRM LIMITS. REPAIR PER MRB 757-907. (M)SDR CALA9601161Floorbeam · corrodedINSPECTION FOUND FLOOR BEAM LOWER CHORD CORRODED AT STA 1130, RBL 1 TO RBL 40. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-40-04, FIGURE 1 AND SRM 51-30-2.SDR 96FDEA01335Floor Beam · corrodedNR0560 AND 007, CORROSION (C53-224-01, -3) ON BS 1110 BEAM RBL 26 TO 45 WL 208.1. *S/D* CUT OUT CORROSION AND INSTALLED REPAIR ON BS 1110 BEAM RBL 26 TO 45 WL 208.1 IAW FEDEX SRM 53-10-8.SDR 96FDEA01333Floor Beam · corrosionNR0466 & 003 CORROSION C53-224-04 ON FLOOR BEAM AROUND CLIP NOT HOLE BS 1110 LBL 16 WL 207.9 *****S/D**** REMOVED DAMAGED AREA & FABRICATED REPAIR ANGLES (2 EA) & REPAIR FILLER, INSTALLED & TREATED ON FLOOR BEAM AT BS 1110 LBL 16 WL 207.9 IAW FEDSDR ASAA9610102Floor Beam · corrodedSEA - DURING D-CHECK, THE UPPER FORWARD FLANGE OF THE FLOOR BEAM BS 500A, LBL 42 TO RBL 43 WAS FOUND TO BE CORRODED. REPAIRED PER EA 5310-01471 AND BOEING TELEX ASA-SEA-96-0355RR. (M)SDR ASAA9610101Floor Beam · corrodedSEA - DURING D-CHECK, THE UPPER AFT FLANGE OF THE FLOOR BEAM BS 887, RBL 4 TO LBL 51 WAS FOUND TO BE CORRODED. REPAIRED PER EA 5310-01468 AND BOEING TELEX ASA-SEA-96-0348RR. (M)SDR 96FDEA01326Floor Beam · corrodedNR 0114 AND 005. CORROSION C53-111-01(3) ON FLOOR BEAM UNDER NUTPLATES AT BS 1050 FROM LBL 32 - RBL 41, WL 200 (AFT BAY). *****S/D***** COMING.SDR 96FDEA01325Floor Beam · corrodedNR0111 AND 004, CORROSION (C53-111-01, -3) ON FLOOR BEAM UNDER NUTPLATES AT BS 1110 WL 200 LBL 32 TO RBL 43 AFT BAY. *S/D* REPAIRED FLOOR BEAM AT BS 1110, WL 200, LBL 32 TO RBL 43 PER FEDEX EA NR 7-5310-29712.SDR 9618636309Floor Beam · corrodedDURING P-CHECK, FOUND CORROSION ON THE FLOOR BEAM UPPER CHORDS BS 460 FROM RBL 39 - 61 AND BS 480 FROM RBL 64 - 75. REPAIRED CHORDS PER EA 63-106559.SDR SWAA960811Floor Beam · crackedDURING SCHEDULED C2 CHECK, FOUND FLOOR BEAM CRACKED AT BS 520, RBL 26. REPAIRED PER BOEING SRM.SDR ASAA9610100Floor Beam · corrodedSEA - DURING D-CHECK, THE LOWER FLANGE OF THE FLOOR BEAM BS 460, LBL 42.5 WAS FOUND TO BE CORRODED. REPARIED PER EA 5310-01459 AND BOEING TELEX ASA-SEA-96-0326RR. (M)SDR ASAA9610099Floor Beam · corrodedSEA - DURING D-CHECK, A PREVIOUS REPAIR OF THE UPPER FORWARD FLANGE OF THE FLOOR BEAM BS 967 WAS FOUND TO BE CORRODED. REPAIRED PER EA 5310-01457 AND BOEING TELEX ASA-SEA-94-0307RR. (M)SDR ASAA9610098Floor Beam · corrodedSEA - DURING D-CHECK, THE LOWER FORWARD FLANGE OF THE FLOOR BEAM BS 480, LBL 42 WAS FOUND TO BE CORRODED. REPAIRED PER EA 5310-01461 AND BOEING TELEX ASA-SEA-96-0332RR. (M)SDR ASAA9610097Floor Beam · corrodedSEA - DURING D-CHECK, THE LOWER FORWARD FLANGE OF THE FLOOR BEAM BS 440, LBL 42.75 WAS FOUND TO BE CORRODED. REPAIRED PER EA 5310-01460 AND BOEING TELEX ASA-SEA-96-0327RR. (M)SDR AALA961161Floor Beam · corrodedTUL - FOUND TOP OF FLOOR BEAM CORRODED, RBL 20 INCHES TO WS 70. INSTALLED REPAIR STRAPS PER 53-10-7-1 PG 1 3727 AARD/MS/MG. (M)SDR 96FDEA01350Floor Beam · corrodedNR0265 AND 009, CORROSION ON BOTTOM OF FLOOR BEAM BS 1070 LBL 55 TO RBL 65. *S/D* REPAIRED FLOOR BEAM AT 1070 LBL 47 TO RBL 65 IAW FEDEX SRM 53-10-8.SDR SWAA960794Floor Beam · crackedDURING SCHEDULED D-CHECK, FOUND FLOOR BEAM WEB CRACKED TWO PLACES, BS 710 AND BS 712, RBL 25, WL 203. REPAIRED PER BOEING SRM.SDR SWAA960792Floor Beam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOOR BEAM CORRODED AT BS 947, RBL 46 TO 43, WL 208. REPAIRED PER BOEING SRM.SDR SWAA960785Floor Beam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOOR BEAM UPPER T-CHORD CORRODED AT BS 294.5, BBL ZERO TO LBL 8. REPAIRED PER BOEING SRM.SDR AALA961188Floor Beam · corrodedTUL - FOUND FLOOR BEAM CORRODED FROM INBOARD SEAT TRACK TO OUTBOARD CREASE ANGLE RIGHT STATION 380. CUT OUT CORRODED FLOOR BEAM UPPER FLANGE AND REPAIRED PER SRM 53-10-8 PG 9B. (M)SDR AWXA960385Floor Beam · corrodedPAE - FLT 7803 - DURING ROUTINE SCHEDULED C-8 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM BS 344, LBL 15 - 30, WL 208. REMOVED, FABRAICATED, INSTALLED REPAIR PARTS PER SRM 53-10-9. (M)SDR 9617609996Floor Beam · crackedDURING M-CHECK, FOUND A CRACK IN THE FS 237 FLOOR BEAM AT LBL 27. REPAIRED BEAM PER EA DC9-53-025.SDR 9617569758Floor Beam · corrodedDURING H-CHECK, FOUND CORROSION IN THE CENTER LINE FLOOR CAP BL 0 FROM FS 218 TO 237. REPAIRED CAP (P/N 5910137-9) PER EA 97-110704.SDR UPS96220804Floor Beam · corrodedINSPECTION TYPE SI, CORROSION ON FLOOR BEAM STA 680 RBL 45 TO 65 WL 208 AROUND NUTPLATE HOLES. BLEND OUT DAMAGE, FABRICATED AND INSTALLED REPAIR ANGLE IAW TRAMCO EWO 96-2427, AUTHORIZED BY UPS ENGINEERING FILE NR 727-53-1799.SDR UPS96220803Floor Beam · corrodedINSPECTION TYPE SI, CORROSION ON TOP AND BOTTOM FLOOR BEAM AROUND NUTPLATES HOLES AT STA 600 RBL 25 TO 60 WL 208. BLEND OUT DAMAGE, FABRICATED AND INSTALLED REPAIR ANGLE IAW TRAMCO EWO 96-2426 UPS ENGINEERING FILE NR 727-53-1801.SDR AWXA960383Floor Beam · corrodedPAE - FLT 7803 - DURING ROUTINE SCHEDULED C-8 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM BS 312, LBL 12 - RBL 24, WL 208. REPLACED TOP CHORD FROM BS 312, LBL 19 - RBL 24, WL 208 PER SRM 53-10-0. (M)SDR 96FDEA01317Floor Beam · corrosionNR0436, FWD CARGO BS 600 BL 0 TO RBL 24 HEAVY CORROSION ON LOWER SIDE OF LOWER LEG OF MAIN CARGO FLOOR BEAM. *S/D* INSTALLED FLOOR BEAM REPAIR PER SRM 53-10-8.SDR UPS96220801Floor Beam · corrodedINSPECTION TYPE SI, CORROSION ON TOP AND BOTTOM FLOOR BEAM AROUND NUTPLATE HOLES AT STA 640 RBL 25 TO 60 WL 208. REPAIRED FLOOR BEAM IAW SRM 53-10-8.SDR UPS96220800Floor Beam · corrodedINSPECTION TYPE SI, CORROSION ON FLOOR BEAM AT STA 344 RBL 50 TO RBL 20 WL 208. REMOVED UPPER CHORD FROM FLOOR BEAM AND PERFORMED FULL SECTION REPAIR AND REPLACEMENT OF CHORD IAW SRM 53-10-8.SDR UPS96220796Floor Beam · corrodedINSPECTION TYPE SI, CORROSION ON FLOOR BEAM AROUND NUTPLATE HOLES STA 660 RBL 50 WL 208. BLENED OUT DAMAGE, HFEC INSPECT FOR CORROSION REMOVAL, FABRICATED AND INSTALLED REPAIR ANGLE IAW TRAMCO EWO 96-2428 UPS ENGINEERING FILE NR 727-53-1797.SDR UPS96220795Floorbeam · corrodedINSPECTION TYPE SI, CORROSION ON TOP AND BOTTOM FLOOR BEAM AROUND NUTPLATE HOLE AT STA 620 RBL 60 WL 208. BLENDED OUT DAMAGE, HFEC INSPECTED, FABRICATED AND INSTALLED REPAIR ANGLE IAW TRAMCO EWO 96-2429 UPS ENGINEERING FILE NR 53-1798.SDR MWEA96374Floor Beam · corrodedDURING D-CHECK, FLOOR BEAM UPPER CAP FOUND EXFOLIATED 15.5 INCHES INBD OF THE CUSP ANGLE AT STA 160. SPLICED IN A NEW SECTION OF CAP IAW DAC TELEX SVC-SMP-0420/SBT.SDR MWEA96336Floor Beam · corrodedDURING D-CHECK, TWO CABIN FLOOR BEAMS WERE FOUND WITH CORROSION ON BEAM FROM CENTERLINE TO RT SIDE OF FUSELAGE AT STA 980 AND 996. INSTALLED REPAIR ANGLE AND FILLERS IAW SRM 53-04, FIG 20A.SDR MWEA96333Floor Beam · corrodedDURING D-CHECK, CABIN FLOOR BEAM CAP AT STA 980 HAD CORROSION ON TOP OF BEAM; FLOOR BEAM UPPER CAP AT STA 996 HAD CORROSION ON TOP AND BOTTOM OF BEAM. REPAIRED AREAS IAW SRM 53-01, 53-05, FIG 20A PG 31.SDR MWEA96330Floor Beam · gougedDURING D-CHECK, FWD CARGO COMPT CEILING LWR FLANGES OF CABIN FLOOR BEAM WERE GOUGED FROM CARGO DOOR HITTING AT STA 389 AND 408. INSTALLED REPAIR IAW SRM 53-05, FIG 86.SDR MWEA96313Floor Beam · corrodedDURING D-CHECK, LIGHT CORROSION FOUND IN UPPER FLANGE OF CABIN FLOOR BEAM BETWEEN NUTPLATES AT STA 996 ABOVE WASTE DRAIN TUBE ON RT SIDE. REPLACED UPPER CAP ANGLE IAW SRM 53-1.SDR UPS96220785Floorbeam · corrodedINSPECTION TYPE SI, CORROSION ON BOTTOM FLOOR BEAM AROUND NUTPLATE HOLES AT STA 560 RBL 45 TO 60 WL 208. REMOVED CORROSION, REWORK DEEMED OUT OF LIMITS IAW SRM 53-10-1. REMOVED AND REPLACED UPPER FLANGES OF FLOOR BEAM IAW 53-10-2.SDR SWAA960740Floor Beam · corrodedDURING SCHEDULED 1/2 D CHECK, FOUND FLOORBEAM CORROSION ON FORWARD EDGE OF BEAM, BS 1016, RBL 4.5. REPAIRED PER SWA RA 1-253-1476.SDR RAIA960753Floor Beam · corrodedFOUND FLOOR BEAM 36 HAS CORROSION. REPAIRED IAW SRM 53-00-00 PG 498. (M)SDR RAIA960751Floorbeam · corrodedFOUND FLOOR BEAM 39 HAS CORROSION. REPAIRED IAW SRM 53-00-00 PG 498.18 FIG 429. (M)SDR RAIA960747Floor Beam · corrodedFOUND FLOOR BEAM 38 HAS CORROSION. REPLACED FLOOR BEAM. (M)SDR ARWR9607003Floor Beam · corrodedFLOOR BEAM AT STA 235 AT LBL 66 CORRODED SECTION AT DUCT CUT-OUT. MECHANICALLY REMOVED CORRODED SECTION. FABRICATED AND INSTALLED 7075.T6 .090 INCH DOUBLER IAW MHA ENGINEERING, INC., E. O. MHA-3067 UNDER AMRC W.O. 960165. (X)SDR AALA961146Floor Beam · corrodedAFW - FLOOR BEAM WITH CORROSION REMOVED. MATERIAL REMAINING IS BEYOND SRM LIMITS. REPAIR PER MRB 757-890. TST: 15,172 HOURS. CYCLES: 5,361. (X)
Back to JASC 5315