JASC 5315

Service difficulty reports · 44,223

Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '5315'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SWAA960749Floor Beam · corrodedDURING SCHEDULED 1/2 D CHECK, FOUND FLOORBEAM CORROSION AT BS 294 ON UPPER SURFACE AND AROUND SCREW HOLES, RBL 1. REPLACED T-CAP PER BOEING SRM.Jul 27, 1996 · N87SW · Boeing 7372H4SDR SWAA960748Floor Beam · corrodedDURING SCHEDULED 1/2 D CHECK, FOUND FLOORBEAM CORROSION AT BS 312 ON UPPER SURFACE AND AROUND SCREW HOLES, LBL 12 TO RBL 3. REPAIRED PER BOEING SRM.Jul 27, 1996 · N87SW · Boeing 7372H4SDR SWAA960747Floor Beam · corrodedDURING SCHEDULED 1/2 D CHECK, FOUND FLOORBEAM CORROSION AT BS 986.5 AT AFT FLANGE AND AT LBL 4. REPLACED PER BOEING SRM.Jul 27, 1996 · N87SW · Boeing 7372H4SDR SWAA960746Floor Beam · corrodedDURING SCHEDULED 1/2 D CHECK, FOUND FLOORBEAM CORROSION AT BS 294, RBL 21, AT BS 294, RBL 39, AT BS 294, RBL 27. REPAIRED PER SWA RA TI 253-08 AND BOEING SRM.Jul 27, 1996 · N87SW · Boeing 7372H4SDR AWXA960377Floor Beam · corrodedPAE - FLT 7848 - DURING ROUTINE SCHEDULED C-16 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM AT STATION 294, LBL 15 TO RBL 45, WL 208. REPLACED UPPER T-CHORD WITH FABRICATED PART BS 294, LBL 60 TO RBL 60, WL 208. (M)Jul 27, 1996 · N181AW · Boeing 737277SDR 9617469856Floor Beam · corrodedDURING H-CHECK, FOUND CORROSION ON THE CENTER LINE FLOOR CAP BL 0 FROM FS 1078 TO 1136. REPAIRED CAP (P/N 5910760-11) PER EA 98-110985.Jul 26, 1996 · N765NC · Doug DC951SDR 9617459856Floor Beam · corrodedDURING H-CHECK, FOUND CORROSION ON THE FS 1136 FLOOR BEAM UPPER CHORD AT RBL 20. REPAIRED CHORD (P/N 9912243-55) PER EA 98-110969.Jul 26, 1996 · N765NC · Doug DC951SDR CALA9601104Floor Beam · crackedINSPECTION FOUND A 2 INCH CRACK IN FLOORBEAM LOWER T-CHORD AT STA 675, BBL ZERO AND A 2 INCH CRACK WAS ALSO FOUND IN CHORD AT STA 685, BBL ZERO. A REPAIR AT STA 675 WAS PERFORMED IAW BOEING DRAWING 65C17173. A REPAIR ANGLE WAS INSTALLED AT STA 685 IAW ECRA 5Jul 25, 1996 · N14241 · Boeing 7372C0SDR USAA960543Floor Beam · corrosionINT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 1 INCH DIAMETER AREAS OF CORROSION STATION 947 FLOOR BEAM UPPER CHORD AT CLIP NUT HOLES. CUT OUT DAMAGED CAP SECTION AND SPLICED IN NEW SECTION PER EA 41312 AND SRM 53-00-51 FIG 202. REPAIRED PER EA 41312 SRM 5Jul 24, 1996 · N434US · Boeing 7374B7SDR USAA960541Floor Beam · corrosionINT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 1 INCH TO 2 INCH DIAMETER SPOTS OF CORROSION AT SCREW HOLES TOP OF FLOOR BEAM BS 987 RBL 48 TO LBL 48. CUT OFF T-CAP, FABRICATED NEW T-CAP HALVES, SPLICE AND INSTALLED. REPAIRED PER EA 41291. CORROSION TASK NRJul 24, 1996 · N434US · Boeing 7374B7SDR USAA960540Floor Beam · corrosionINT - DURING Q-4 CHECK VISUAL INSPECTION, CORROSION .25 INCH SQUARE FLOOR BEAM BS 967 LBL 18. INSTALLED DOUBLERS, REPAIRED PER SRM 53-30-51. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)Jul 24, 1996 · N434US · Boeing 7374B7SDR USAA960539Floor Beam · corrosionINT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND CORROSION AROUND CAP HOLES FLOOR BEAM BS 312 BL 0 TO LBL 28. SPLICED 'T' CAP AND DOUBLERS, REPAIRED PER TR 53-10-13. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)Jul 24, 1996 · N434US · Boeing 7374B7SDR USAA960538Floor Beam · corrosionINT - DURING Q-4 CHECK VISUAL INSPECTION, FOUND 1 INCH DIAMETER SPOTS OF CORROSION AT SCREW HOLES FLOOR BEAM BS 344 BBL '0' TO LBL 43. INSTALLED NEW SECTION OF 'T' CAP, REPAIRED PER TR 53-10-3. CORROSION TASK NR C53-107-02, CORROSION LEVEL 1. (M)Jul 24, 1996 · N434US · Boeing 7374B7SDR UPS96420828Upperchord · crackedINSPECTION TYPE CPCP, MAIN DECK FLOOR BEAM UPPER CHORD CORRODED AT BS 1000 BETWEEN RBL 70 TO 100. REMOVED CORROSION IAW SRM 51-10-01, UPPER CHORD OUT OF LIMITS IAW SRM 53-10-01. REPAIRED UPPER CHORD AT BS 1000 FROM RBL 70 TO RBL 108 IAW SRM 53-10-07.Jul 24, 1996 · N675UP · Boeing 747123SDR SWAA960724Floor Beam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOOR BEAM UPPER FLANGE SCREW HOLE CORROSION AT BS 294, LBL 25. REPLACED T-CAP PER BOEING SRM AND TI 253-008.Jul 24, 1996 · N87SW · Boeing 7372H4SDR 96ZZZX4357Floor Beam · corrodedLEVEL 2 CORROSION, CORROSION ON FLOOR BEAM AT FS 923, RLB 36, UNDER CART TIE DOWN. REMOVED DAMAGED SECTION OF BEAM, FABRICATED AND INSTALLED REPAIR PER SRM 53-21-00. (X)Jul 24, 1996 · N312GB · Lkheed 10113851SDR 96ZZZX4351Floor Beam · corrodedLEVEL 2 CORROSION, FLOOR BEAM IS CORRODED FORWARD OF RT CART STOWAGE AREA AT FLOOR PANEL ATTACH HOLES FS 901. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PER SRM 53-21-00. (X)Jul 24, 1996 · N312GB · Lkheed 10113851SDR UPS96220723Floor Beam · corrodedINSPECTION TYPE SI, CORROSION (C53-224001.05-01) ON TOP AND BOTTOM FLOOR BEAM AROUND NUTPLATE HOLE AT STA 312 LBL 25 WL 208. MECHANICALLY REMOVED CORROSION, REWORK DEEMED OUT LIMITS IAW SRM 53-10-1. REPAIRED CORROSION DAMAGE REWORK ON STA 312 FLOOR BEAM LBL Jul 23, 1996 · N920UP · Boeing 727180CSDR SWAA960722Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOOR BEAM UPPER FLANGE CORRODED AT BS 344 LBL 4 TO 22. REPLACED T-CAP PER BOEING SRM.Jul 23, 1996 · N87SW · Boeing 7372H4SDR SWAA960721Floor Beam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOOR BEAM CORRODED AT BS 344, ON LOWER SURFACE OF SCREW HOLES, LBL 25 TO 38. REPLACED T-CAP PER BOEING SRM.Jul 23, 1996 · N87SW · Boeing 7372H4SDR SWAA960720Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOOR BEAM UPPER FLANGE CORRODED AT BS 344 LBL 4 TO 22. REPLACED T-CAP PER BOEING SRM.Jul 23, 1996 · N87SW · Boeing 7372H4SDR SWAA960712Floor Beam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOOR BEAM CORRODED AT BS 987,5, LBL 40, WL 208 AT RBL 40, WL 208. REPAIRED PER BOEING SRM.Jul 23, 1996 · N59SW · Boeing 7372H4SDR SWAA960709Floor Beam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOOR BEAM CORRODED AT BS 312, LBL 7 AND AT BL 0, WL 208. REPAIRED PER BOEING SRM.Jul 23, 1996 · N59SW · Boeing 7372H4SDR SWAA960708Floor Beam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOOR BEAM CORRODED AT BS 294 RBL 15, 27, 39, 44.5 AND 46.5. REPAIRED PER BOEING SRM.Jul 23, 1996 · N59SW · Boeing 7372H4SDR SWAA960703Floor Beam · corrodedDURING SCHEDULED D-CHECK, FOUND COCKPIT FLOOR BEAM CORROSION AT BS 203 WL 208 RBL 12 TO 18. REPAIRED PER BOEING SRM.Jul 23, 1996 · N59SW · Boeing 7372H4SDR AWXA960369Floor Beam · corrodedPAE - FLT 7827 - DURING ROUTINE SCHEDULED C-11 MAINTENANCE CHECK, FOUND CORROSION AT AFT. CARGO BAY CARGO FLOOR BEAM BS 796-817, RBL 13.5 AT NUTPLATE HOLES, TOP OF BOTTOM SIDE. REPLACED SECTION OF FLOOR BEAM FROM BS 780 TO 821 AT RBL 13.5 PE SRM 53-00-51. (MJul 23, 1996 · N164AW · Boeing 73733ASDR UPS96420821Floor Beam · corrodedINSPECTION TYPE: C. MAIN DECK FLOORBEAM: FOUND FLOOR BEAM UPPER CHORD CORRODED AT BS 1580 RBL 69/88. CORROSION REMOVED ON UPPER CHORD BS 1580 RBL 69/88 IAW SRM 51-10-01. UPPER CHORD OUT OF LIMITS IAW SRM 53-10-01, REPAIRED UPPER CHORD BETWEEN RBL 69/88 IAJul 22, 1996 · N675UP · Boeing 747123SDR AWXA960368Floor Beam · corrodedPAE - FLT 7827 - DURING ROUTINE SCHEDULED C-11 MAINTENANCE CHECK, FOUND CORROSION AT BS 986, WL 208, BL 10-LBL 20 ON TOP OF BEAM. REMOVED DAMAGE, FABRICATED REPAIR PARTS AND INSTALLED PER SRM 53-00-51. (M)Jul 22, 1996 · N164AW · Boeing 73733ASDR AWXA960367Floor Beam · corrodedPAE - FLT 7827 - DURING ROUTINE SCHEDULED C-11 MAINTENANCE CHECK, FOUND CORROSION AT BS 947, WL 208, RBL 10 TO LBL 12 ON TOP OF FLOOR BEAM. REMOVED DAMAGE, FABRICATED REPAIR PARTS AND INSTALLED PER SRM 53-00-51. (M)Jul 22, 1996 · N164AW · Boeing 73733ASDR USAA960532Floor Beam · corrosionINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND TWO 1 INCH BY 3INCH CORRODED AREAS AT NUT PLATE HOLES T-CAP, BS 312 FLOOR BEAM BBL 0, RBL8. INSTALLED T-CAP REPAIR AND REPAIRED PER SRM 53-10-9. CORROSION TASK NRC53-107-02, CORROSION LEVEL 1. (M)Jul 19, 1996 · N283AU · Boeing 7372B7SDR USAA960531Floorbeam · corrosionINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORROSION 3INCHES AT FLOOR BEAM STATION 1006 LBL 8. CUT OFF T-CAP THAT WAS OUT OFLIMITS, FABRICATED REPLACEMENT AND INSTALLED PER SRM 53-10-9 FIG 2.CORROSION TASK NR C53-107-02, CORROSION LEVEL 1. (M)Jul 19, 1996 · N283AU · Boeing 7372B7SDR USAA960530Floor Beam · corrosionINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND .33 INCH CORRODEDAREA FLOOR BEAM BS 947.5 RBL 10 TO LBL 36. INSTALLED REPLACEMENT T-CAP,REPAIRED PER TR 53-10-05C. CORROSION TASK NR C53-107-02, CORROSION LEVEL 1. (M)Jul 19, 1996 · N283AU · Boeing 7372B7SDR USAA960528Floorbeam · corrosionINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1 INCH CORRODEDAREAS FLOOR BEAM BS 967. INSTALLED DOUBLER REPAIRED PER SRM 53-10-9.CORROSION TASK NR C53-107-02, CORROSION LEVEL 1 (M)Jul 19, 1996 · N283AU · Boeing 7372B7SDR USAA960527Floor Beam · corrosionINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND SEVERAL 1 INCH BY1 INCH CORRODED AREAS ON FLOOR BEAM BS 328 RBL 12 INCH TO RBL 45 INCH.INSTALLED NEW T-CAP WITH REPAIR ANGLES, REPAIRED PER TR 53-10-13. CORROSIONTASK NR C53-107-02, CORROSION LEVEL 1. (M)Jul 19, 1996 · N283AU · Boeing 7372B7SDR USAA960526Floor Beam · corrosionINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 2 INCHCORRODED AREA FLOOR BEAM BS 360 RBL 54. INSTALLED REPAIR ANGLE, REPAIREDPER TR 53-10-05 C. CORROSION TASK NR C53-107-02, CORROSION LEVEL 1.(M)Jul 19, 1996 · N283AU · Boeing 7372B7SDR USAA960521Floor Beam · corrosionINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORROSION 90INCHES AT STATION 986 FLOOR BEAM UPPER CHORD. INSTALLED NEW SECTION WITHREPAIR ANGLES AND STRAPS, REPAIRED EA 41317. CORROSION TASK NR C53-107-02,CORROSION LEVEL 1. (M)Jul 19, 1996 · N283AU · Boeing 7372B7SDR USAA960519Floor Beam · chaffingINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 10 INCHESCHAFFING STATION 720 RHS KEEL BEAM LOWER CORD OUTBOARD FLANGE. INSTALLEDREPAIR STRAP, REPAIRED PER EA 41322. (M)Jul 19, 1996 · N283AU · Boeing 7372B7SDR USAA960518Floor Beam · corrosionINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 4 INCHCORRODED AREA ON TOP OF FLOOR BEAM BS 1016 LBL 16 LBL 5. INSTALLED FLOORBEAM REPAIR, REPAIRED PER SRM 53-10-9. CORROSION TASK NR C53-017-02,CORROSION LEVEL 1. (M)Jul 19, 1996 · N283AU · Boeing 7372B7SDR UPS96420846Floor Beam · corrodedINSPECTION TYPE: CPCP. MAIN DECK FLOORBEAM UPPER CHORD CORRODED AT BS 860 BETWEEN RBL 65/110. CORROSION REMOVED IAW SRM 51-10-01. OUT OF LIMITS PER SRM 53-10-01. UPPER CHORD AT BS 860 RBL 65 TO RBL 110 REPAIRED IAW SRM 53-10-07.Jul 19, 1996 · N675UP · Boeing 747123SDR SWAA960691Floor Beam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM CORROSION AT BS 986, RBL 5. REPAIRED PER BOEING SRM.Jul 19, 1996 · N89SW · Boeing 7372H4SDR 96FDEA01269Floor Beam · corrodedDISCREPANCY: (NR 1123) FLOORBEAM CORRODED UPPER CHORD STA 400, LBL 32-41 (MAIN CARGO). CORRECTIVE ACTION: REMOVED DAMAGED SECTION OF UPPER CHORD. INSTALLED FLOORBEAM REPAIR PER SRM 53-10-8, FIG 3.Jul 19, 1996 · N116FE · Boeing 72725CSDR USAA960533Floorbeam · corrosionINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 8 INCHCORROSION FLOOR BEAM F/S 1016 BL 0 TO RBL 12. SPLICED IN FLOOR BEAM T-CAPAND DOUBLERS REPAIRED PER SRM 53-10-9 EA 41313. (M)Jul 18, 1996 · N244US · Boeing 737201SDR UPS96420822Floor Beam · corrodedINSPECTION TYPE: C. MAIN DECK FLOOR BEAM UPPER CHORD CORRODED AT BS 680 BETWEEN 11 RT/LT. CORROSION REMOVED ON UPPER CHORD AT BS 680 BETWEEN 11 RT/LT. UPPER CHORD OUT OF LIMITS IAW SRM 53-10-01. REPAIRED UPPER CHORD AT BS 680 BETWEEN 11 RT/LT IAW SRM 51-Jul 18, 1996 · N675UP · Boeing 747123SDR DHL9671503DFloor Beam · corrodedAT D- CHECK, FOUND FLOOR BEAM CORRODED AT FWD UPPER FLANGE LOWER SURFACE RBL 60 BS 600. CUT OUT AREA, INSTALLED REPAIR PER SRM 53-10-8, 2.5 INCHES BY 13 INCHES .Jul 17, 1996 · N715DH · Boeing 727155CSDR EISA96118Floor Beam · corrodedFLOOR BEAM UNDER LAVATORY FLOOR IS CORRODED. REMOVED DAMAGED FLOOR STRINGER, FABRICATED AND INSTALLED NEW STRINGER PER SRM'S 51-40-04, 51-10-02, AND 51-20-01. TT: 66,991:57 HOURS. TC: 45,084. (X)Jul 16, 1996 · N310NE · Boeing 7272A7SDR AALA961362Floor Beam · gougedAFW - FOUND FLOOR BEAM WEB AT STATION 1640 AND RBL 24-75 HAS GOUGE, PER SRM 757-949. (M)Jul 16, 1996 · N664AA · Boeing 757223SDR AALA961072Floor Beam · crackedTULE - FOUND CRACK IN FLOOR BEAM WEB STATION 826.95 BELOW RIGHT LIGHTING HOLE CUTOUT. CRACKS ENDS IN RIVET HOLE. INSTALLED REPAIR PER SRM 61-40-2 PG 1-66. (M)Jul 16, 1996 · N731AA · Boeing 727227SDR 96FDEA01260Floor Beam · corrosionDISCREPANCY: NR 0259(033) CORROSION (C53-111-01) AROUND NUTPLATES AROUND EXISTING FLOOR BEAM REPAIR STA 600 RBL 1, 5, 8, 12, 15, 19, 24, WL 198 (FWD BAY). CORRECTIVE ACTION: *****S/D******** COMING.Jul 16, 1996 · N195FE · Boeing 72722SDR P5CA9600590Floor Beam · corrodedLEVEL 1 CORROSION ON RT OTBD MAIN DECK FLOOR BEAM UPPER CHORD AT STA 2360. REMOVED CORROSION PER BAC SRM 51-10-01 AND RE-PROTECTED PER SRM 51-10-02.Jul 15, 1996 · N856FT · Boeing 747132SDR P5CA9600581Floor Beam · corrodedLEVEL 1 CORROSION ON MAIN DECK RT OTBD FLOOR BEAM STA 2240. CORROSION REMOVED AND RE-PROTECTED PER BAC SRM 51-10-01 AND SRM 51-1-02.Jul 15, 1996 · N856FT · Boeing 747132
Back to JASC 5315