SDR 96FDEA00297Floorbeam · corrodedCORROSION (C53-111-01, 2) ON LOWER FLANGE OF FLOORBEAM IN NUTPLATE HOLES AT BS 620 LBL 20 TO RBL 26 WL 200. REPAIRED FLOORBEAM BS 620 LBL 20 TO RBL 26 WL 200 IAW FEDEX SRM 53-10-8.SDR 96FDEA00294Floorbeam · double drilledWHILE WORKING NR0754, FOUND DOUBLE HOLE IN BS 990 FLOORBEAM AT BL 0 WL 208. REMOVED DAMAGE, FABRICATED REPAIR PARTS AND INSTALLED PER SRM 53-10-8.SDR 96FDEA00293Floorbeam · double drilledWHILE WORKING NR0754, FOUND DOUBLE HOLE IN BS 970 FLOORBEAM AT BL 0 WL 208. REMOVED DAMAGE, FABRICATED REPAIR PARTS AND INSTALLED PER SRM 53-10-8.SDR 96FDEA00290Floorbeam · corrodedCORROSION AT BS 540 FLOORBEAM LOWER CHORD FROM LBL 16 TO RBL 28 WL 200. REPAIRED LOWER CHORD OF FLOORBEAM AT BS 540 WL 200 FROM LBL 16 TO RBL 28 IAW FEDEX SRM 53-10-08.SDR 9605489858Floor Beam · crackedDURING H-CHECK, FOUND A TWO-INCH CRACK IN THE FS 237 FLOOR BEAM, LBL 6. REPAIRED BEAM (P/N 9911544-5) PER EA 98-102654.SDR UPS205595Floorbeam · corrosionWHILE IN FOR C-CHECK, MAINTENANCE REPORTED CORROSION ON FLOORBEAM UPPER CHORD AROUND NUTPLATE HOLES STA 680 LBL 60 TO RBL 60, WL 208. CORROSION REMOVAL ON FLOORBEAM UPPER CHORD WAS OUT OF LIMITS PER SRM 53-10-1. BLENDED AREA, FABRICATED REPAIR ANGLES, REPAIRSDR UPS205593Floorbeam · corrosionWHILE IN FOR C-CHECK, MAINTENANCE REPORTED CORROSION (C53-224-01.05-01) ON FLOORBEAM UPPER CHORD STA 600 RBL 45 TO RBL 65 WL 208, AROUND NUTPLATE HOLES. CORROSION REMOVAL ON UPPER CHORD OF FLOORBEAM WAS OUT OF LIMITS. BLENDED AREA, FABRICATED AND INSTALLED RSDR UPS205592Floorbeam · corrosionWHILE IN FOR C-CHECK, MAINTENANCE REPORTED CORROSION (C53-224-01.05-01) ON FLOORBEAM UPPER CHORD AROUND NUTPLATE HOLES STA 660 RBL 10 TO RBL 55. MECHANICALLY REMOVED CORROSION FROM 660 FLOORBEAM UPPER CHORD RBL 10 TO 58. FOUND REWORK FROM RBL 54 TO 58 TO BE SDR AWXA960090Floor Beam · corrodedPAE - FLT NR 3887 - DURING ROUTINE C-7 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM BS 987, LBL 5 - RBL 5, WL 208. FOUND CORROSION ON UPPER CHORD OF FLOOR BEAM BS 987 LBL-RBL 5 TO BE OUT OF LIMITS PER SRM 53-10-1. REMOVED CORRODED UP CHORD OF FLOOR BEAM FSDR 9606532297Floor Beam · corrodedDURING H-CHECK, FOUND CORROSION ON THE BS 1130 FLOOR BEAM UPPER CHORD FROM LBL 18 TO 43. REPAIRED CHORD PER EA 22-103466.SDR 96FDEA00311Floorbeam · corrodedCABIN FLOORBEAM AT STA 950 IS CORRODED AROUND SCREW HOLES TOP AND BOTTOM OF BEAM FROM SEAT TRACK NR 3 TO NR 5. REMOVED CORROSION PER 51-10-06, OUT OF LIMITS. REPAIRED PER ESO 11782 AND FEDEX EA 7-5310-27477.SDR 9605465505Floor Beam · corrodedDURING T-CHECK, FOUND CORROSION ON THE BS 345 FLOOR BEAM UPPER CHORD AT LBL 10. REPAIRED CHORD (P/N 141N5111) PER EA 55-99492.SDR 96012122808Floor Beam · corrodedRIGHT MAIN FLOOR SUPPORT BEAM AT FS 1880 RT, RBL 36 IS CORRODED BEYOND SRM LIMITS. REMOVED AND REPLACED FLOOR SUPPORT BEAM IAW SRM 51-30-00. (X)SDR CAL960196Floor Beam · corrodedGSO - INSPECTION FOUND FLOOR BEAM CORRODED AT STATION 312 FROM RBL 30 TO LBL 11. THE UPPER T-CAP WAS REMOVED FROM LBL 11 TO RIGHT CUSP. A NEW T-CAP SEGMENT WAS FABRICATED AND INSTALLED IAW SRM 51-10-2, 51-70-12, 51-20-01, AND 51-40-00. (M)SDR 96FDEA00287Floor Beam · double holeDOUBLE HOLE IN FLOORBEAM BS 500 BL 0 WL 208.1. *S/D* REPAIRED DOUBLE HOLE AT BS 500, BL 0 WL 208.1 IAW FEDEX SRM 57-10-8.SDR SWAA960096Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOORBEAMS CORRODED AT BS 986 LBL 30 TO RBL 51, BS 328 RBL 14 AND 15 WL 208 AND BS 986 WL 208 RBL 5, 24, 32, 43 AND LBL 43. REPAIRED PER BOEING SRM.SDR UPS96805782Floor Beam · corrodedWHILE IN FOR C-CHECK, MAINTENANCE REPORTED HEAVY CORROSION ON LOWER SURFACE OF FLOOR BEAM FS 35 RBL 50. REPAIRED PER UPS EO DC8-53-1586.SDR UPS96805781Floor Beam · corrodedWHILE IN FOR C-CHECK, MAINTENANCE REPORTED HEAVY CORROSION ON LOWER SURFACE OF FLOOR BEAM FS 55 RBL 50. REPAIRED PER UPS EO DC8-53-1583.SDR UPS96205696Floor Beam · corrodedWHILE IN FOR C-CHECK, MAINTENANCE REPORTED FS 680 RBL 3 TO 10, FLOOR BEAM UPPER FLANGE IS CORRODED BEYOND LIMITS. REMOVED DAMAGED SECTION FROM LBL 9 TO RBL 65.0 IAW SRM 53-10-8 FIG 5, REPAIRED IAW SRM 53-10-8 AND 51-30-3.SDR CAL960200Floor Beam · corrodedGSO - INSPECTION FOUND L-2 DOOR THRESHOLD FLOOR BEAM CHORD CORRODED FROM STATION 940 TO STATION 986. THE CHORD SEGMENT WAS REMOVED FROM STATION 910 TO 1006 AND A NEW CHORD WAS INSTALLED IAW SRM 51-40-02 AND BAC DRAWING 65C80735. (M)SDR CAL960199Floor Beam · corrodedGSO - INSPECTION FOUND FS 986.5 MAIN CABIN FLOOR BEAM UPPER CHORD CORRODED AT RBL 37, RBL 23, RBL 10, LBL 6.5, LBL 19.5 AND LBL 32. THE UPPER CHORD SECTION WAS CUT OFF FROM CUSP TO CUSP. A 'T' ANGLE WAS INSTALLED IAW SRM 53-00-51 AND A 'T' CHORD UPPER SEGMENSDR USAA960272Floor Beam · corrosionINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1 INCH BY 1 INCH OF CORROSION STATION 986.5 FLOOR BEAM UPPER FLANGE AT SCREW HOLES LBL 52 TO RBL 52. REMOVED UPPER CHORD AND SPLICED IN NEW CHORD PER EA 40883. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. SDR USAA960271Floor Beam · corrosionINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 1 INCH DIAMETER SPOTS OF CORROSION AT SCREW HOLES TOP OF FLOOR BEAM BS 344 LBL 50 TO RBL 8. CUT OUT SECTION OF UPPER CHORD AND SPLICED IN NEW SECTION OF T-CAP PER TR 53-10-03. CORROSION TASK NR C53-107-02, CORRSDR USAA960270Floor Beam · corrodedINT - DURING Q-6 CHECK VISUAL INSPECTION, FUOND 1 INCH DIAMETER SPOTS OF CORROSION AT SCREW HOLES TOP OF FLOOR BEAM BS 328 LBL 9 TO RBL 21. CUT OUT SECTION OF UPPER CHORD AND REPAIRED EPR SRM 53-10-51 FIG 205. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2.SDR USAA960259Floor Beam · crackedINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 2 INCH CRACK IN RADIUS BS 520 RBL 45 INCHES INBOARD SIDE OF SEAT TRACK FLOOR BEAM. REPAIRED PER EA 40888 STEPS 1 AND 2. (M)SDR USAA960258Floor Beam · corrosionINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND .5 BY 32 INCH CORROSION FLOOR BEAM BS 294 RBL 7 - RBL 60. INSTALLED T-CAP AND REPAIRED ANGLES PER SRM 53-10-51. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)SDR USAA960254Floor Beam · corrosionINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 4 INCH BY .5 INCH CORRODED FLOOR BEAM BS 947 LBL 5 AND RBL 6, LBL 16. INSTALLED T-CAP PER EA 40816. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)SDR USAA960252Floor Beam · corrodedINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 5 INCHES OF SCRATCHES AND CORROSION ON FLOOR BEAM BS 312 LBL 15 TO 20. SPLICED 'T' SECTION PER TR 53-10-03. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)SDR USAA960251Floor Beam · corrodedINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND 3 INCH BY 4 INCH CORRODED AREA AND SEVERAL 1 INCH BY 1 INCH AREAS AT BS 794 RBL 14 INCHES CARGO FLOOR BEAM. CUT OUT CORRODED SECTION (BS 779-877) FABRICATED AND INSTALLED NEW BEAM SECTION PER BOEING DRAWING 65-5SDR AWXA960077Floor Beam · corrodedPAE - FLT NR 3889 - DURING ROUTINE C-8 MAINTENANCE CHECK, FOUND FLOOR BEAM TOP FLANGE CORRODED AT FLOOR BOARD HOLES STATION 312. REMOVED DAMAGED AREA OF FLOOR BEAM UPPER CHORD FROM LBL 19 TO RBL 24. REPAIRED PER 737 SRM 53-10-51. (M)SDR AALA960296Floor Beam · corrodedAFW - FLOOR BEAM AT LBL 33, STA 865, HAS CORROSION. REPAIRED PER MRB 767-1136. TST: 12,783.33 HRS. CYCLES, 2,028. (X)SDR 96FDEA00385Floor Beam · corrosionUPPER LOBE CORROSION ON FLOOR BEAM STA 360 TOP CHORD, AFT FLANGE, BOTTOM SIDE LBL 8. INSTALLED REPAIR PER SRM 53-10-2 FIG 3.SDR 96FDEA00280Floor Beam · corrosionCORROSION (C53-111-01, -2) ON LOWER FLANGE OF FLOOR BEAM IN NUTPLATE HOLES AT BS 600 LBL 20 TO RBL 26 WL 200. *S/D* REMOVED AND CORRODED AREA FROM LBL 17 TO RT SKIN FABRICATED AND INSTALLED REPAIR PARTS PER FDE SRM 53-10-18 FIG 2.SDR 96FDEA00230Floor Beam · corrodedCORROSION (C53-111-01, -2) ON LOWER FLANGE OF FLOOR BEAM AT BS 640 LBL 23 TO RBL 26.7 WL 200. *(S/D)* REMOVED AND CORRODED ON LOWER FLANGE OF FLOOR BEAM IN NUTPLATE HOLES AT BS 640 LBL 23 TO RBL 26.7 WL 200. REPAIR PARTS PER FDE SRM 53-10-8.SDR 96ZZZX2830Floor Beam · crackedDURING CHECK STA 1701 FLOOR BEAM LBL 39, FOUND AFT SIDE UPPER PORTION CORRODED AND CRACKED. INSTALLED NEW FLOOR BEAM IAW LACI E.O. 3523.SDR 96FDEA00640Floor Beam · corrodedFLOOR BEAM UPPER CHORD LOWER SURFACE CORRODED STA 344, LBL 50 - RBL 10, WL 200. INSTALLED FLOOR BEAM REPAIR PER STANDARD REPAIR DRAWING MANUAL SR 27-53-007.SDR 96FDEA00395Floor Beam · corrodedFLOOR BEAM UPPER CHORD LWR SURFACE CORRODED STA 344 LBL 50 TO RBL 10 WL 200. *S/D* INSTALLED FLOOR BEAM REPAIR PER STANDARD REPAIR DRAWING MANUAL SRM 27-53-007, NR0346.SDR AALA960294Floor Beam · gougedAFW - FOUND AND BLENDED OUT GOUGES ON THE UPPER SURFACE OF THE MAIN CABIN FLOORBEAM. THE BLEND-OUT EXCEEDS SRM LIMITS. ROTO-PEENED, DYE CHECKED, ALODINED, PRIMED, AND PAINTED DAMAGED AREAS. APPROVED FOR CONTINUED SERVICE BY ENGINEERING PER SRB 767-1142. TSSDR 96FDEA00253Floorbeam · misdrilledWHILE WORKING NR0754, FOUND DOUBLE HOLE IN BS 990 FLOORBEAM AT BL 0 WL 208.SDR 96FDEA00252Floorbeam · misdrilledWHILE WORKING NR0754, FOUND DOUBLE HOLE IN BS 970 FLOORBEAM AT BL 0 WL 208.SDR 96FDEA00251Floor Beam · double drilledWHILE WORKING CARD NR 0683, FOUND BS 600 FLOOR BEAM, BL 0 WL 208 TO HAVE DOUBLE HOLE. *S/D* REPAIRED FLOOR BEAM BS 600, BL 0, WL 208 IAW FEDEX SRM 53-10-8, HOLE PER SRM 53-10-8.SDR 96FDEA00250Floor Beam · double holeWHILE WORKING CARD NR 0685, FOUND BS 580 FLOOR BEAM, BL 0 WL 208 TO HAVE DOUBLE HOLE. *S/D* REPAIRED DOUBLE HOLE PER SRM 53-10-8 SRM 53-10-8.SDR 96FDEA00240Floorbeam · corrodedCORROSION (C53-224-01) ON UPPER CHORD OF BS 950 FLOORBEAM AT RBL 21 WL 208. CLEANED AND TREATED CORROSION ON UPPER CHORD OF BS 950 FLOORBEAM AT RBL 21 WL 208, FOUND TO BE WITHIN LIMITS PER FEDEX EA 7-5310-27447.SDR UPS96805712Floor Beam · corrodedWHILE IN FOR C-CHECK, MAINTENANCE REPORTED HEAVY CORROSION ON FLOOR BEAM, FS 1680, RBL 35. REPAIRED PER UPS E.O. DC8-53-1588.SDR AALA960274Floor Beam · corrodedAFW - CORROSION WAS BLENDED BEYOND SRM LIMITS ON FLOOR BEAM AT STA 324, RBL 58, PER MRB 757-723. TST: 15,773. CYCLES: 5,917. (X)SDR 9604502762Floorbeam · corrodedDURING H-CHECK, FOUND CORROSION ON THE BS 1130 FLOORBEAM UPPER AND LOWER CHORDS BETWEEN LBL 39 AND RBL 51. REPAIRED CHORDS (P/N 65-20821) UPPER, (P/N 65-20838-17) LOWER, PER EA 27-103458 AND -103454 RESPECTIVELY.SDR DL72K960342Floorbeam · corrodedFOUND ON MV1 CHECK, CORROSION SEVERAL PLACES FLOORBEAM STA 344. REPAIRED PER SRM 53-10-8 FIG 11.SDR 96FDEA00234Floorbeam · corrodedCORROSION (C53-224-06) ON FLOORBEAM AT BS 620 RBL 10 TO 43 WL 208. REMOVED DAMAGED SECTION OF FLOORBEAM, FABRICATED REPAIR PARTS, CLEANED, TREATED AND INSTALLED PARTS. ALL WORK ACCOMPLISHED IAW FEDEX SRM 53-10-8 AT BS 620 RBL 10 TO 43 WL 208.SDR SWIA95724Floor Beam · corrodedFLOOR BEAM RT RBL 9.0 WL 73.50 STA 310 TO 349, CORROSION FOUND ON UPPER SURFACE. CORROSION BEYOND LIMITS OF REO 601R-53-00-00 SHT 3 FIG 1 .003 STN 319.0. FLOOR BEAM REPAIRED IAW REO 601R-53-21-058.SDR SWIA95723Floor Beam · corrodedFLOOR BEAM RIGHT O/B RBL 27.00 WL 73.5 STA .295 TO 349, CORROSION FOUND ON TOP SURFACE. REMOVAL OF CORROSION IS BEYOND LIMITS OF REO 601R-53-00-005. FLOOR BEAM REPAIRED IAW 601R-53-21-058.
Back to JASC 5315