JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 96FDEA00455Floor Beam · corrodedCORROSION ON FLOOR BEAM UPPER CHORD, BS 1030, LBL 9, RBL 10 AND 21, WL 208. *** S/D **** REMOVED DAMAGE, FABRICATED AND INSTALLED REPAIR PARTS ON FLOOR BEAM UPPER CHORD BS 1030, RBL 10, WL 203 PER FEDEX SRM 53-10-8, FIG 8. REMOVED .011 INCH OF ORIGINAL .12SDR 96FDEA00453Floor Beam · gougedFLOOR BEAM AT BS 277, LBL 15, WL 208, IS GOUGED. **** S/D **** REMOVED DAMAGE, FAB AND INSTALLED REPAIR PARTS PER FEDEX SRM 51-40-4, FIG 1.SDR UPS96205701Floor Beam · corrosionWHILE IN FOR C-CHECK, MAINTENANCE REPORTED FWD LOWER CARGO STA 640 BETWEEN LBL 44 TO 62. FLOOR BEAM UPPER FLANGE AFT SIDE HAS HEAVY EXFOLIATION CORROSION IN SEVERAL PLACES. REPAIRED DAMAGE AREA OF FLOOR BEAM LBL 8 TO LBL 62 IAW SRM 53-10-8 FIG 5, SRM 51-30-2SDR DL72K960520Floor Beam · corrodedFOUND ON CV-1 CHECK CORROSION ON FLOOR BEAM STA 380 RBL 55. REPAIR: REPAIRED PER M/M 53-20-11.SDR UPS96205911Floor Beam · corrosionWHILE IN FOR C-CHECK, MAINTENANCE REPORTED FS 312, LBL 26 FLOOR BEAM UPPER FLANGE AFT BOTTOM SIDE FOUND TO BE OUT OF LIMITS AFTER CORROSION REMOVAL. REPAIRED PER SRM 53-10-8, FIG 7.SDR CAL960345Floor Beam · corrodedGSO - INSPECTION FOUND FLOOR BEAM UPPER CAP CORRODED AT STA 328, RBL 45 TO RBL 65. THE FLOOR BEAM UPPER CAP WAS REMOVED IAW SRM 53-10-9. A NEW CAP AND SPLICE ANGLES WERE FABRICATED AND INSTALLED IAW SRM 53-10-9 AND SRM 51-30-0. (X)SDR 96FDEA00427Floor Beam · corrosionCORROSION (C53-224-01, 3) (C53-22404) ON UPPER CHORD OF FLOOR BEAM BS 1110 RBL 35 AND 41 WL 208. REPAIRED UPPER CHORD OF FLOOR BEAM BS 1110 RBL 41 IAW FEDEX SRM 53-10-8. REMOVED CORROSION AT RBL 35 AND FOUND TO BE WITHIN LIMITS IAW FEDEX SRM 53-10-1.SDR 96FDEA00647Floor Beam · crackedCABIN FLOOR BEAM CRACKED/CORRODED ON UPPER FLANGE, BS 480, LBL 28. REPAIRED CRACKED/CORRODED FLOOR BEAM, STA 480, LBL 28, PER SRM 53-10-8, FIG 5.SDR 96FDEA00400Floor Beam · corrodedCABIN FLOOR BEAM CORRODED ON UPPER FLANGE STA 480 LBL 28. *S/D* REPAIRED CRACKED/CORRODED FLOOR BEAM STA 480 LBL 28 FIG 5.SDR 96FDEA00399Floor Beam · corrodedCABIN FLOOR BEAM TOP AFT FLANGE CORRODED ON UPPER AND LWR SURFACE STA 420 LBL 0 TO 24. *S/D* REMOVED CORRODED SECTION FAB AND INSTALLED REPAIR PER SRM 53-10-8 FIG 8.SDR 96FDEA00398Floor Beam · corrodedCABIN FLOOR BEAM CORRODED ON UPPER SURFACE STA 640 BL 0 TO RBL 65. *S/D* REPAIRED IAW SRM 53-10-8 NR0781.SDR UPS96805863Floor Beam · crackedWHILE IN FOR C-CHECK, MAINTENANCE REPORTED CORROSION AND CRACK AT FWD BEAM, FS 920 LBL 65 AFT SIDE. REPAIRED PER UPS EO.SDR N3VR96016Floor Beam · corrosionREF N/R 3691, FS 312, 37 INCHES RIGHT OF C/L FLOOR BEAM HAS CORROSION BEYOND BLEND LIMITS. REMOVED DAMAGED SECTION OF FLOOR BEAM IAW SRM 51-30-2. FABRICATED MATERIAL FROM TM 560-23934 PICKED UP HOLES IAW SRM 51-10-1, TREATED AND PRIMED IAW SRM 51-10-2, INSTASDR N3VR96015Chord · corrosionREF N/R 3699, FS 1030, 20 INCHES LT OF C/L FLOOR BEAM CORROSION BEYOND BLEND OUT LIMITS UPPER CHORD. REMOVED CORRODED SECTION OF FLOOR BEAM, FABRICTED REPAIR PARTS IAW SRM 53-10-8 USING MATERIAL BAC 1505-100617, 7075-T73 TREATED AND PRIMED BEAM AND REPAIRED PSDR CAL960364Floor Beam · corrodedGSO - INSPECTION FOUND FLOOR BEAM AND WEB CORRODED IN COCKPIT UNDER CAPTAIN'S SEAT. THE AREA WAS REPAIRED IAW SRM 51-40-2 AND ECRA 5310-03239. (X)SDR N3VR96020Floor Beam · corrosionREF N/R 3626, CORROSION STATION 344 AT CLIP NUT HOLE FLOOR BEAM PANEL NR 2 FORWARD EDGE BOTH SURFACES. REMOVED CORROSION IAW SRM 51-10-6. INSPECTION FOUND OUT OF LIMITS, CUT OUT DAMAGED SECTION. FABRICATED REPAIR PARTS IAW SRM 53-10-8-8-2A USING BAC 1505-10SDR N3VR96014Beam · corrosionREF N/R 3658, SURFACE CORROSION ON FLOOR BEAM STATION 312 AT CLIP NUT HOLES FT OF COCKPIT DOOR (BOTH SURFACES). REMOVED CORROSION IAW SRM 51-10-6 AT 3 INCHES LT OF C/L AND AT 19 INCHES OF C/L MAX MATERIAL REMOVED .050, TREATED AND PRIMED IAW SRM 51-10-2. FABSDR 96FDEA00380Floor Beam · double drilledWHILE WORKING NR0308 FOUND HOLE IN RADIUS OF FLOOR BEAM LOWER CHORD BS 580 BL 0 WL 200. *S/D* REPAIRED FLOOR BEAM PER SRM 53-10-8.SDR 96FDEA00358Floor Beam · corrodedCORROSION (C53-111-01, -2) ON LOWER FLANGE OF FLOORBEAM IN NUTPLATE HOLES AT BS 600 LBL 20 TO RBL 26 WL 200. REMOVED CORRODED AREA FROM LBL 17 TO RT SKIN. FABRICATED AND INSTALLED REPAIR PARTS PER FEDEX SRM 53-10-8 FIG 2.SDR 9606555523Floor Beam · corrodedDURING PERIODIC CHECK, FOUND CORROSION ON THE UPPER SURFACES OF THE BS 345 FLOOR BEAM AT RBL 8 AND THE BS 365 FLOOR BEAM FROM BL 0 TO RBL 18. REPAIRED BOTH BEAMS (P/N 141N5111, 141N5112 RESPECTIVELY) PER EA 55-99500 AND -82879 RESPECTIVELY.SDR UPS205606Floorbeam · corrodedWHILE IN FOR C-CHECK, MAINTENANCE REPORTED CORROSION ON FLOORBEAM UPPER FLANGE BS 1110 RBL 50 TO 56 LBL 3 TO 20 AND 40 TO 44. REMOVED CORROSION, OUT OF LIMITS REPAIRED PER EWO 96-2087.SDR N3VR96018Floor Beam · corrosionREF N/R 3559, FLOOR BEAM HAS CORROSION STATION 344 C/L LT AND RT 10 INCHES. FABRICATED T-CAP IAW SRM 51-40-4 USING T-EXTRUSION 60-23934 TREATED AND PRIMED, INSTALLED IAW SRM 51-40-4. (M)SDR N3VR96006Floor Beam · corrosionREF N/R 3560, FLOOR BEAM CORROSION STATION 380 LEFT OF SEAT TRACK NR 4 APPROXIMATELY 12 INCHES AREA. REMOVED CORROSION IAW SRM 51-10-6 NEG MATERIAL REMOVED, TREATED AND PRIMED IAW SRM 51-10-2. (M)SDR AWXA960104Floor Beam · corrodedPAE - FLT NR 3873 - DURING SCHEDULED C-8 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM BS 312, RBL 8 TO LBL 25, WL 208. CORROSION OUT OF LIMITS. REMOVED AND REPLACED UPPER CHORD ON FLOOR BEAM BS 312, RBL 12 TO LBL 30, WL 208. (M)SDR AWXA960103Floor Beam · corrodedFLT NR 3873 - PAE - DURING SCHEDULED C-8 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM RBL 8-12 AND LBL 8, WL 208, BS 297. CORROSION OUT OF LIMITS. REMOVED AND REPLACED UPPER CHORD OF FLOOR BEAM AT BS 297, WL 208, LBL 24 TO RBL 29. (M)SDR AWXA960101Floor Beam · corrosionPAE - FLT NR 3873 - DURING SCHEDULED C-8 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM STATION 344, WL 208, LBL 3-50. REPAIRED FLOOR BEAM AT BS 344, WL 208, PER SRM 53-10-51. (M)SDR AWXA960099Floor Beam · corrosionPAE - FLT NR 3873 - DURING SCHEDULED C-8 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM STATION 344 WL 208, LBL 3-50. REPAIRED FLOOR BEAM AT BS 344, WL 208, PER SRM 53-10-51. (M)SDR AALA960322Floor Beam · corrodedAFW - FLOOR BEAM AT STA 345 HAS CORROSION REMOVED BEYOND SRM LIMITS, PER MRB 757-733. TST: 15,758.46 HRS. CYCLES: 5,958. (X)SDR AALA960321Floor Beam · corrodedAFW - FLOOR BEAM AT STA 377.7 HAS CORROSION REMOVED ON UPPER SURFACE BEYOND SRM LIMITS, PER MRB 757-737. TST: 15,758.46 HRS. CYCLES: 5,958. (X)SDR AALA960320Floor Beam · corrodedAFW - FLOOR BEAM AT STA 365 HAS CORROSION REMOVED BEYOND SRM LIMITS, PER MRB 757-734. TST: 15,758.46 HRS. CYCLES: 5,958. (X)SDR AALA960317Floor Beam · corrodedAFW - FLOOR BEAM AT STA 1640 HAS CORROSION REMOVED ON UPPER SURFACE BEYOND SRM LIMITS, PER MRB 757-756. TST: 15,758.46 HRS. CYCLES: 5,958. (X)SDR 96FDEA00342Floorbeam · corrodedCORROSION (C53-111-01, -3), ON LOWER CHORD OF 1110 FLOORBEAM WL 200 LBL 2 TO 30 AT NUTPLATE HOLES. REMOVED AND REPLACED CORRODED LOWER CHORD OF BS 1110 FLOORBEAM AT WL 200 RBL 4 TO LBL 19.75 WITH FABRICATED REPAIR PARTS PER SRM 53-10-8 FIG 2.SDR 96FDEA00337Floorbeam · double drilledDOUBLE HOLE IN FLOORBEAM BS 500 BL 0 WL 208.1. REPAIRED DOUBLER HOLE AT BS 500 BL 0 WL 208 IAW FEDEX SRM 53-10-8.SDR 96FDEA00334Floorbeam · double drilledWHILE WORKING CARD NR0683, FOUND BS 600 FLOORBEAM BL 0 WL 208 TO HAVE DOUBLE HOLE. REPAIRED FLOORBEAM BS 600 BL 0 WL 208 IAW FEDEX SRM 53-10-8.SDR 96FDEA00333Floorbeam · double drilledWHILE WORKING CARD NR0683, FOUND BS 580 FLOORBEAM BL 0 WL 208 TO HAVE DOUBLE HOLE. REPAIRED DOUBLE HOLE PER FEDEX SRM 53-10-8.SDR 96FDEA00332Floorbeam · double drilledWHILE WORKING CARD NR0683, FOUND BS 540 FLOORBEAM BL 0 WL 208 TO HAVE DOUBLE HOLE. REPAIRED FLOORBEAM AT BS 540 BL 0 WL 208 IAW FEDEX SRM 53-10-8.SDR 96FDEA00329Floorbeam · corrosionCORROSION (C53-111-01, -2), ON LOWER FLANGE OF FLOORBEAM BS 640 RBL 23 TO 26.7 WL 200. REMOVED CORROSION ON LOWER FLANGE OF FLOORBEAM IN NUTPLATE HOLES AT BS 640 LBL 20 TO RBL 26 WL 200. FOUND TO BE OUT OF LIMITS AT RBL 23 TO RBL 26.5, REPAIRED IT AS PER FEDSDR CAL960431Floorbeam · oversized holeINSPECTION FOUND OVERSIZED HOLE ON MAIN CABIN INTERIOR FLOORBEAM AT BS 350, RBL 40. THE EFFECTED SECTION WAS REMOVED. A REPAIR DOUBLER AND FILLER WERE FABRICATED AND INSTALLED IAW SRM 51-30-2, 51-10-1, 51-10-2, 51-30-8 AND MM 51-20-2. (M)SDR CAL960296Floor Beam · corrodedHOU - INSPECTION FOUND CORROSION ON FLOOR BEAM AT STA 148 - STA 200, RIGHT OF CENTERLINE. THE FLOOR BEAM WAS REMOVED AND REPLACED IAW SRM 51-10-1. (X)SDR USAA960278Floor Beam · corrosionINT - DURING Q-6 CHECK VISUAL INSPECTION, FOUND CORRODED NUT PLATE HOLES AT FLOOR BEAM STATION 460-500 ABOVE STRINGER 27 R. REPLACED ANGLE, REPAIRED PER SRM 53-10-5 FIG 6. CORROSION TASK NR C53-202-01, CORROSION LEVEL 2. (M)SDR UPS96805753Floor Beam · corrodedWHILE IN FOR C-CHECK, MAINTENANCE REPORTED HEAVY CORROSION ON LOWER SURFACE OF FLOOR BEAM FS 12 RBL 50. REPAIRED PER UPS EO DC8-53-1582.SDR UPS205602Floorbeam · corrosionWHILE IN FOR C-CHECK, MAINTENANCE REPORTED CORROSION (C53-224-01.05-01), ON FLOORBEAM STA 312 LBL 48 TO LBL 0 WL 208 AROUND NUTPLATE HOLES. REMOVED AND REPLACED FLOORBEAM IAW UPS SRM 53-10-8, 51-10-6, 53-10-1.SDR UPS205594Floorbeam · corrosionWHILE IN FOR C-CHECK, MAINTENANCE REPORTED CORROSION (C53-224-01.05-01), ON FLOORBEAM UPPER CHORD STA 640, LBL 60 TO RBL 60, WL 208 AROUND NUTPLATE HOLES. CORROSION REMOVAL WAS OUT OF LIMITS. REMOVED DAMAGED SECTION, FABRICATED REPAIR PARTS AND INSTALLED PERSDR UPS205591Floorbeam · corrosionWHILE IN FOR C-CHECK, MAINTENANCE REPORTED CORROSION (C53-224-01-05-03), ON FLOORBEAM UPPER FLANGE BS 1030, RBL 10 AND LBL 0 TO 58, WL 208. CORROSION REMOVAL ON FLOORBEAM UPPER FLANGE WAS OUT OF LIMITS. REMOVED DAMAGED SECTION, FABRICATED REPAIR PARTS AND INSDR CAL960432Floorbeam Web · crackedINSPECTION FOUND A .375 INCH CRACK IN LEFT FRAME OF FLOOR BEAM WEB OF RIGHT FORWARD LAV, BS 312, RBL 29. THE CRACKED AREA WAS REMOVED. A DOUBLER AND FILLER REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-10-2 AND 51-30-2. (M)SDR AALA960307Floor Beam · corrodedTUL - FLOOR BEAM CORRODED. AFTER BLENDING FOUND BEYOND SRM LIMITS. ALODINED AND FILLED BLENDED AREA. FABRICATED AND INSTALLED REPAIR STRAP USING .063 INCH 7075-T6 ALUMINUM. PRIMED FLOOR BEAM AND STRAP. APPROVED BY ENGINEERING PER MRB 767-1155. TST: 38,2SDR 96FDEA00321Floor Beam · double drilledWHILE WORKING NR0754, FOUND DOUBLE HOLE IN BS 1010 FLOOR BEAM AT BL 0 WL 208. *S/D* REMOVED DAMAGED, FABRICATED REPAIR PARTS AND INSTALLED PER SRM 53-10-8.SDR 96FDEA00316Floor Beam · corrodedCORROSION (C53-111-01, -2) ON LOWER FLANGE OF FLOORBEAM IN NUTPLATE HOLES AT BS 620 LBL 20 TO RBL 26 WL 200. *S/D* REPAIRED FLOOR BS 620, LBL 20 TO RBL 26, WL 200 IAW FEDEX SRM 53-10-8.SDR 96FDEA00301Floorbeam · double drilledWHILE WORKING NRO754, FOUND DOUBLE HOLE IN BS 1010 FLOORBEAM AT BL 0 WL 208. REPAIRED FLOORBEAM BS 1010 BL 0 WL 208 IAW FEDEX SRM 53-10-8.SDR 96FDEA00300Floorbeam · double drilledWHILE WORKING CARD NR0683, FOUND BS 560 FLOORBEAM BL 0 WL 208 TO HAVE 3 DOUBLE HOLES. REPAIRED FLOORBEAM AT BS 560 BL 0 WL 208 IAW FEDEX SRM 53-10-8, (P/N BAC 1505-100617).
Back to JASC 5315