SDR 95FDEA01244Floorbeam · corrodedSTA 1110 FLOORBEAM IS CORRODED ON TOP AND BOTTOM OF UPPER CAP AREA, WHERE FLOOR BOARDS MOUNT BETWEEN NR 5 AND NR 6 SEAT TRACKS. REPAIRED PER SRM 53-10-8.SDR 95FDEA01243Floorbeam · corrodedCORROSION AROUND FASTENER HOLES ON FLOORBEAM AT STA 1110 FROM 3 TO 20 RBL. REPAIRED PER SRM 51-10-6.SDR 95FDEA01242Floorbeam · corrodedTOP FLANGE OF FLOORBEAM AT STA 600 CORRODED BEYOND SRM LIMIT RBL 46.5 APPROX. CUT OUT DAMAGE, REPAIRED PER SRM 53-10-8 PG 44 TO 48. DAMAGE CUT OUT WAS 1 BY 1.5.SDR 95FDEA01241Floorbeam · corrodedFLOORBEAM UPPER CAP WHERE FLOORBEAM MOUNTS IS CORRODED AROUND SCREW HOLES BETWEEN 5 AND 6 SEAT TRACKS STA 1070. REPAIRED PER SRM 53-10-8.SDR 95FDEA01231Floorbeam · crackedBS 380 RBL 26 TO 32, MAIN CARGO FLOORBEAM UPPER FLANGE IS CRACKED AND CORRODED. REMOVED CRACKED AND CORRODED SECTION OF UPPER FLANGE OF BS 380 RBL 16.75 AND 35.25 RBL, FLOORBEAM. FABRICATED DOUBLER PER SRM 53-10-8 PG 2A. INSTALLED FLOORBEAM REPAIR PER SRM 5SDR USAA950951Floor Beam · corrosionINT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORROSION 1 INCH BY 40 INCHES STATION 344 LBL 24 INCHES - RBL 24 INCHES. REPLACED SECTION OF T-CAP. REPAIRED PER TR 53-10-3. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)SDR USAA950949Floor Beam · corrosionINT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND .5 INCH BY 14 INCH CORRODED BS 328 RBL 28-42 ON FLOOR BEAM. SPLICED IN NEW SECTION OF T-CAP. REPAIRED 737-300/400 TR 53-10-03. CORROSION TASK NR C53-107-02, CORROSION LEVEL 2. (M)SDR USAA950948Floor Beam · corrosionINT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND .5 INCH BY 13 INCH CORROSION BS 312 RBL 7 INCHES THROUGH RBL 20 INCHES ON FLOOR BEAM T-CAP. REPAIRED PER SRM 737-400 53-10-51 FIG 206 PAGE 224. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (M)SDR 95FDEA01240Floorbeam · corrodedCORROSION STA 620 LBL 12 CABIN FLOORBEAM. INSTALLED DOUBLER ASSY PER SRM 53-10-6 FIG 8.SDR USAA950997Floor Beam · corrosionINT - DURING Q-3 CHECK VISUAL INSPECTION, FOUND 2 INCH BY 4 INCH CORROSION BS 947.5 TO BS 967 RBL 45 ON FLOOR BEAM T-CAP. FABRICATED NEW T-CAP 18 INCHES LONG, REPAIRED PER SRM 53-00-51. CORROSION TASK NR C53-107-02. CORROSION LEVEL 2. (M)SDR EISA95308Floor Beam · crackedUPON A SCHEDULED INSPECTION AT AERO IN LAKE CITY, FL, THE AFT CARGO PIT WAS FOUND WITH A CRACKED FLOOR SUPPORT BEAM IN THE CENTER SECTION AT BS 1166. REMOVED CRACKED FLOOR SUPPORT BEAM. FABRICATED NEW FLOOR SUPPORT BEAM, SPLICE, TWO L-ANGLES AND INSTALLED ALSDR SWAA950604Floorbeam · crackedDURING SCHEDULED B/C1 CHECK, FOUND FLOORBEAM STRAP CRACKED AT BS 344, JUST O/B AND ABOVE BATTERY. REPAIRED PER BOEING STRUCTURAL REPAIR MANUAL.SDR 95FDEA01215Floorbeam · damagedWHILE WORKING NR O652 DISCOVERED DAMAGE TO FLOORBEAM WEB AT BS 1110 BL 0 WL 207. PREVIOUSLY CAUSED DURING INSTALLATION OF HAYES CARGO MOD. REPAIRED FLOORBEAM PER FEDEX EA 7-5310-25620.SDR 95FDEA01210Floorbeam · corrodedCORROSION (72C237-02), ON TOP CHORD OF BS 1030 FLOORBEAM RBL 9 TO 22 LBL 51.5 WL 208. MECHANICALLY REMOVED CORROSION FROM TOP CHORD OF FLOORBEAM AT BS 1030 RBL 9 TO 22 LBL 51.5 AREA WAS OUT OF LIMITS PER FEDEX SRM 53-10-1. REPAIRED TOP CHORD OF FLOORBEAM AT SDR 95FDEA01209Floorbeam · corrodedCORROSION ON TOP CHORD OF BS 1110 FLOORBEAM RBL 8 TO 55 LBL 47 TO 55 WL 208. MECHANICALLY REMOVED CORROSION FROM TOP CHORD OF FLOORBEAM AT BS 1110 RBL 8 LBL 55 WL 208. TOP CHORD WAS FOUND TO BE OUT OF LIMITS PER FEDEX SRM 53-10-1. REMOVED AND REPLACED TOP SDR 9513882204Floorbeam · corrodedDURING PERIODIC CHECK, FOUND CORROSION ON THE BS 1130 FLOOR BEAM UPPER CHORD. REPAIRED BEAM (P/N 65-20838-16), PER EA 22-99070.SDR 95FDEA01211Floorbeam · corrodedCORROSION ON TOP CHORD OF FLOORBEAM BS 1070 AT LBL 13 LBL 47.5 TO 54 RBL 15 TO 52 WL 208. CUT OUT DAMAGED UPPER CHORD OF FLOORBEAM FROM LBL 65 RBL 65 AND REPAIRED PER SRM 53-10-08 FIG 3.SDR AWXA9500580Floorbeam · corrodedDURING SCHEDULED C7 INSPECTION, FOUND FOUR AREAS OF CORROSION BEYOND LIMITS ON UPPER CHORD AT STATION 986.5, RBL 3.54 TO RBL 18.32. REMOVED DAMAGED SECTION OF FLOORBEAM. REPLACED EXTRUSION AND SPLICE ANGLES PER SRM 53-00-51, FIG 202. (M)SDR ASAA9510079Floor Beam · corrodedSEA - DURING C-CHECK, FOUND CORROSION ON FLOOR BEAM AT STATION 1006. REMOVED CORROSION AND REPAIRED PER ASA EA 5310-01381. (M)SDR AALA951541Floor Beam · corrodedAFW - FLOOR BEAM IN CABIN CORRODED. FOUND BEYOND SRM LIMITS AFTER BLENDING. ALODINED AND FILLED BLENDED AREA. FABRICATED AND INSTALLED REPAIR STRAP USING .050 INCH 301.5 HARD STAINLESS STEEL. APPROVED BY ENGINEERING PER MRB 767-990. (M)SDR AALA951538Floor Beam · corrodedAFW - FLOOR BEAM CORRODED. FOUND BEYOND SRM LIMITS AFTER BLENDING. ALODINED AND FILLED BLENDED AREA. FABRICATED AND INSTALLED REPAIR STRAP USING .050 INCH 301 AND A HALF HARD STAINLESS STEEL. APPROVED BY ENGINEERING PER MBB 767-991. (M)SDR 95FDEA01201Floorbeam · corrodedCORROSION (72C235-02), ON FLOORBEAM UPPER FLANGE BS 620 RBL 8 TO 17 WL 208. REMOVED AND REPLACED UPPER FLOORBEAM T-CHORD BS 620 LBL 15 RBL 34 PER FEDEX SRM 53-10-8.SDR 95FDEA01197Floor Beam · corrodedTHE UPPER CHORD OF THE BS 480, FLOOR BEAM IS CORRODED OUT OF LIMITS AT RBL 12, WL 208.5. CUT OUT DAMAGED AREA AND REPAIRED PER SRM 53-10-08, FIG 3.SDR 9513329163Floorbeam · corrodedDURING H-CHECK, FOUND FLOORBEAM AT LEFT LAVATORY CORRODED AT FS 817. REPAIRED PER EA 91-102775.SDR USAA950921Floor Beam · corrosionINT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORROSION ON NUT PLATE HOLES ON TOP OF FLOOR BEAM CAP, BS 986.5 RBL 23-37 AND LBL 20-42. INSTALLED NEW CAP ON FLOOR BEAM (ENTIRE LENGTH). REPAIRED PER TR 53-10-05. CORROSION TASK NR C53-107-02, CORROSION LEVELSDR 95FDEA01219Floorbeam · corrodedBS 560 LBL 29 TO 32 MAIN CARGO, FOUND CORROSION ON TOP LEG OF FLOORBEAM BETWEEN LT INBD AND LT CENTER CARGO TIE-DOWN TRACKS. REMOVED CORROSION INSTALLED REPAIR PER 53-10-8 PG 31 TO 48.SDR USAA951024Floor Beam · crackedCLT - DURING A Q3-CHECK INSPECTION, VISUALLY FOUND A 1.4 INCH CRACK LOCATED AT STATION 520 EXTENDING .6 INCH OUTBOARD AND .8 INCH INBOARD OF LBL 45.5. INSTALLED DOUBLER. (M)SDR 95FDEA01218Floorbeam · corrodedCORROSION TOP AFT FLANGE ON STA 1110 FLOORBEAM, LOWER SIDE AT FASTENER HOLES RBL 35 TO 40 AFT CARGO CEILING, NR 0994.SDR 95FDEA01217Floorbeam · corrodedCORROSION IN UPPER LOBE FLOORBEAM, UPPER FWD FLANGE STA 1110 RBL 48 TO 60, NR 0996.SDR 95FDEA01216Floorbeam · corrodedHEAVY CORROSION LOWER FLANGE OF UPPER LOBE FLOORBEAM STA 1110 RBL 28 TO 30 IN AFT CARGO COMPT CEILING, NR 0993.SDR 95FDEA01165Floorbeam · corrodedCORROSION (72C235-02), ON FLOORBEAM BOTTOM SIDE OF UPPER FLANGE BS 660 RBL 50 WL 208.SDR UPS204220Floorbeam · corrodedWHILE IN FOR C-CHECK, MAINTENANCE FOUND DOUBLE HOLES AND CORROSION ON FLOORBEAM AND NUTPLATE HOLES AT STA 480 RBL 25 TO 65 WL 208. MAINTENANCE REPAIRED IAW UPS EO B727-5310-7318A.SDR SWAA950591Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM CORROSION AT BS 294.5 RBL 42 AND 45. REPAIRED PER SWA RA 1-553-1325 AND BOEING STRUCTURAL REPAIR MANUAL.SDR SWAA950587Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM CORROSION AT BS 947 LBL 10 AND 5 AT BS 986.5 LBL 15 AND RBL 6. REPAIRED PER SWA RA 1-553-1329 AND BOEING STRUCTURAL REPAIR MANUAL.SDR SWAA950586Floorbeam · corrodedDURING SCHEDULED 1/2 D-CHECK, FOUND FLOORBEAM CORROSION AT BS 312 LBL 14. REPAIRED PER SWA RA 1-553-1327 AND BOEING STRUCTURAL REPAIR MANUAL.SDR SWAA950581Floorbeam · corrodedDURING SCHEDULED D-CHECK, FOUND FLOORBEAM CORROSION AT BS 1016 LBL 5 WL 208 AND AT BS 294 AT LBL12 WL 208. REPAIRED PER BOEING STRUCTURAL REPAIR MANUAL.SDR DL73S953564Floorbeam · crackedDURING HMV IN ATL, THE CABIN FLOORBEAM WAS FOUND CRACKED INTHE OP FLANGE AT STA 663, BL 0. THE UPPER CAP OF THE FLOORBEAM IS CRACKED COMPLETELY THROUGH THE HORIZONTAL FLANGE. ANOTHER CRACK EXISTED IN THE WEB JUST FWD OF THE DAMAGED CAP. THESE CRACKS WILL BE SDR AALA951694Floor Beam · corrodedAFW - CORROSION BLENDED ON FLOOR BEAM AT STATION 345, LBL 12, IS BEYOND SRM LIMITS, PER MRB 757-589. (M)SDR AALA951693Floor Beam · corrodedAFW - CORROSION BLENDED ON FLOOR BEAM AT STATION 324, RBL 61 IS BEYOND SRM LIMITS, REPAIRED PER MRB. (M)SDR UPS204177Floor Beam · corrodedWHILE IN C-CHECK, MAINTENANCE FOUND CORROSION ON THE FLOOR BEAM AROUND NUT PLATE HOLES STA 380 RBL 45-60 AND LBL 45-65, WL 208. MAINTENANCE FABRICATED AND INSTALLED NEW REPAIR STRAP AND ANGLE IAW E.O. B727-5310-7283A, SRM 51-10-6, 51-10-2, AND 51-30-2.SDR UPS204162Floorbeam · corrodedWHILE IN FOR C-CHECK, MAINTENANCE FOUND CORROSION ON FLOORBEAM AROUND NUTPLATE HOLES AT STA 312 LBL 45 TO 60 WL 208. MAINTENANCE REPAIRED THE FLOORBEAM IAW SRM 53-10-8, 51-10-6 AND 53-10-1.SDR UPS204155Floorbeam · corrodedWHILE IN FOR C-CHECK, MAINTENANCE FOUND CORROSION ON THE TOP AND BOTTOM FWD FLOORBEAM AROUND NUTPLATE HOLES AT STA 400 RBL 15 TO 45 WL 208. MAINTENANCE REPAIRED THE FLOORBEAM IAW SRM 53-10-8 AND 53-10-1.SDR UPS204154Floorbeam · corrodedWHILE IN FOR C-CHECK, MAINTENANCE FOUND CORROSION ON THE TOP AND BOTTOM FWD FLOORBEAM AT STA 640 LBL 45 TO RBL 65 WL 208. MAINTENANCE REPAIRED THE FLOORBEAM IAW UPS EO 727-53-1654.SDR UPS204152Floorbeam · corrodedWHILE IN FOR C-CHECK, MAINTENANCE FOUND CORROSION ON THE TOP AND BOTTOM FWD FLOORBEAM AROUND NUTPLATE HOLES AT STA 668 RBL 16 TO 60, 65 WL 208. MAINTENANCE BLENDED AWAY CORROSION AND INSTALLED A REPAIR ANGLE IAW SRM 51-10-6, 53-10-01.SDR UPS204136Floorbeam · corrodedWHILE IN FOR C-CHECK, MAINTENANCE FOUND CORROSION (C53-224-01.05-01) ON TOP AND BOTTOM OF FLOORBEAM AROUND NUTPLATE HOLES AT STA 680 RBL 60 TO 65 LBL 11 WL 208. MAINTENANCE INSTALLED NEW CHORD AND SPLICED. ALL WORK WAS PERFORMED IAW SRM 530-10-1, 53-10-8, 51SDR CAL950755Floor Beam · corrodedIAH - INSPECTION FOUND CORROSION ON TOP OF FLOOR BEAM AT STATION 1016, LBL 5.5. THE FLOOR BEAM WAS REPAIRED IAW SRM 53-00-51, FIGURE 202 AND ECRA 5310-03151. (M)SDR CAL950744Floor Beam · corrodedIAH - INSPECTION FOUND CORROSION ON FLOOR BEAM OF L-2 DOOR THRESHOLD AT STATION 986-1006. THE AREA WAS REPAIRED IAW SRM 51-40-01. (M)SDR AWXA9500543Floor Beam · corrodedPHX - DURING SCHEDULED C4 INSPECTION, FOUND SEVERAL AREAS OF CORROSION ON TOP SURFACE OF CABIN FLOOR 'I' BEAM UPPER CHORD FROM FRAME 17 TO FRAME 19 AT Y 1292. INSTALLED NEW FLOOR BEAM SECTION PER SRM 51-72-11 AND SRM 51-42-21. (M)SDR AALA951695Floor Beam · corrodedAFW - FLOOR BEAM AT STATION 1640 HAS CORROSION REMOVED BEYOND SRM LIMITS, PER MRB 757-586. (M)SDR DL72K953500Floorbeam · corrodedFOUND ON CV2 CHECK, CORROSION AROUND FASTENER HOLES FLOORBEAM UPPER SURFACE STA 344 LBL 45 RBL 13. REPAIRED PER SRM 53-10-8 FIG 10.
Back to JASC 5315