JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2021052137114Channel · bentAFT CARGO COMPARTMENT; STA 727 BLKHD; LWR FLOOR SUPPORT 'U' CHANNEL IS BENT. / REMOVED BENT AFT CARGO COMPARTMENT STA 727 BLKHD LWR FLOOR SUPPORT U CHANNEL AND REPLACED WITH NEW U CHANNEL; P/N 453A2611-25 IAW SRM 51-40-02-0G-0 AND BOEING P/N 453A2611 REV D ATASDR SWAA2021042337127Angle · corrodedAFT CARGO BAY; BULKHEAD FLOOR ANGLE; BS 947; RBL 18; WL156; CORRODED / REMOVED CORROSION IAW SRM 51-10-02 ORIGINAL MATERIAL THICKNESS .080 LOSS OF .004 WITH .076 FOUND TO BE OUT OF LIMITS DUE TO NO DOCUMENTED LIMITS. ACCOMPLISHED AAR EA 200562 REV IR / SWA W/ISDR SWIA202056735Floor Support · corroded*PRESSURE FLOOR STRUCTURE €ŒFLOOR BEAM€? AT RBL9 BETWEEN APPROX. FS693 AND FS847 HAS CORROSION(MARKED). (C-CHECK) RO 3/8/2021 REMOVED CORROSION AND COMPLIED WITH REO 670-53-41-505 REV--, 2021-01-14 AND, / COMPLIED WITH TASK CARD 51-900-1002-SKYSDR SWIA202056733Plate · corroded*AVIONICS BAY DOOR SURROUND: JOINT PLATE ON THE FS364 FRAME AND STGR25L LONGERON IS CORRODED (MARKED). (C-CHECK) RO 3/8/2021 REPLACED A-BAY DOOR SURROUND JOINT PLATE WITH A NEW ONE. REF: CRJ-700 SRM 51-42-21-001-001-A01, REO-670-53-21-1934 REV -- DATE 202SDR SWIA202056732Plate · corroded*AVIONICS BAY DOOR SURROUND: JOINT PLATE ON THE FS364 AND STGR25R LONGERON IS CORRODED (MARKED). (C-CHECK) RO 3/8/2021 REPLACED AVIONICS BAY DOOR SURROUND: JOINT PLATE ON THE FS364 AND STGR25R LONGERON. REF. DWG SH670-32050 REV. D / COMPLIED WITH 51-900-1SDR SWIA202056727Intercostal · corroded*GALLEY SERVICE DOOR SURROUND STRUCTURE, INTERCOSTAL AT STGR20R, BETWEEN FS310 TO FS319 IS CORRODED. (MARKED) (C-CHECK) RO 3/8/2021 REMOVE AND REPLACED INTERCOSTAL AT STGR 20R BWTN FS 310.00 TO 319.00 REF DWG SH670-32047 REV NC AND REF CRJ700 SRM 51-42-21SDR SWIA202056726Door Sill · corroded*PASSENGER DOOR SURROUND, BACK-UP SILL AT STRG21L, BETWEEN FS310 AND FS333 IS CORRODED. (MARKED) (C-CHECK) RO 3/8/2021 REPLACED PASSENGER DOOR SURROUND, BACK UP SILL AT STGR 21L BETWEEN FS310-FS333 WITH NEW. REF CRJ-700 SRM 51-42-21-001-001-A01, CRJ-700 SSDR SWAA2021011137238Angle · corrodedFWD CARGO COMP AFT BULKHEAD RT Z-ANGLE CORRODED AROUND FASTENER HOLES STA 500D-500I RBL 25' WL 158. REMOVED CORROSION, VERIFIED USING 10X MAG GLASS, IAW SRM 51-10-02-0G-0. EVALUATED DAMAGE AS LOSS OF 0.01' FOUND TO BE OUT OF LIMITS, IAW SRM 53-00-53-1A-2. RSDR SWAA2021010737235Channel · corrodedFWD CARGO COMP LT Z-ANGLE CORRODED AROUND FASTENER HOLES STA 500E-500I LBL 25' WL 158. FWD CARGO LT Z-ANGLE REPAIR ACCOMPLISHED ON W/O Y246074 P/N 1437501-187.SDR SWAA2021010737234Angle · corrodedFWD CARGO COMP LT Z-ANGLE CORRODED AROUND FASTNER HOLES STA 500A-500E LBL 25' WL 158. ACCOMPLISHED Z-ANGLE REPAIR IN FWD CARGO LT SIDE FROM STA 500A TO 500I LBL 25' WL 158, IAW SRM 53-00-53-2R-5 P/N 143A7501-187.SDR SWAA2021010737123Angle · corrodedAFT CARGO BAY; Z-ANGLE BS 767-727; RBL 23; WL 156; CORRODED. REMOVED CORROSION ON ZEE ANGLE AFT CARGO STA 767-727 RBL 23 WL 156, IAW SRM 51-10-02-0G-0 AND INSPECTED W/10X MAG GLASS. EVALUATED MATERIAL LOSS STA 727 TO STA 727G: ORIGINAL T=.040' REMAINING T=.0SDR AALA202101049012Fitting · crackedAIRCRAFT IN BASE MAINTENANCE. CRACKED FLIGHT DECK LEFT HAND CENTER WINDOW POST CONTINUITY FITTING AT FR 2 AND Y20. REPLACED CONTINUITY FITTING, PER EO 5319Y017.SDR AALA202101049011Fitting · crackedAIRCRAFT IN BASE MAINTENANCE. CRACKED FLIGHT DECK RIGHT HAND CENTER WINDOW POST CONTINUITY FITTING AT FR 2 AND -Y20. REPLACED CONTINUITY FITTING, PER EO 5319Y017.SDR YENA2020122100618Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION LOWER SILL FR 66RT AFT GALLEY AREA (CPCP RELATED 534147-01). REMOVED AND REPLACED LOWER SILL LOCATED ON RT SIDE AT LEVEL OF STR 23R BETWEEN FR 66 TO FR 68, IAW A320 SRM 51-72-11 AND DWG NR D53480505. WORK STEPS PERFORMED SDR DALA2020121704138Floor Support · corrodedREWRITE DUE TO MEASUREMENTS OF THE FLOOR STRINGERS ARE INCORRECT. CORROSION LEVEL 2 ON FLOOR STRINGERS RBL 2.90, 7.55, 10.45 16.10, STA 1470 AT AFT CARGO COMPARTMENT WERE REPAIRED PER SRM.SDR DALA2020121704134Panel · corrodedDURING INITIAL INSPECTION MAINTENANCE FOUND CORROSION LEVEL 2 ON RT SIDE PANEL (UPPER AND LOWER SURFACE), BETWEEN STA 1440 TO 1520 AT AFT CARGO COMPARTMENT. REPLACED SIDE PANEL, PER SRM.SDR DALA2020121704133Floor Support · corrodedINITIAL INSPECTION MAINTENANCE FOUND LEVEL 2 CORROSION ON FLOOR SUPPORT NEXT TO FLOOR STRINGER 10.45 RBL FROM STA 1460/1480 AT AFT CARGO COMPARTMENT. FLOOR SUPPORT REPAIRED, PER SRM 51-70-11.SDR AALA202012179002Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE. FOUND CRACK SHEAR PLATE AT STR 23R BETWEEN FR 69 TO FR 70 AT AFT GALLEY AREA. REPLACED SHEAR PLATE, IN ACCORDANCE WITH SRM A319 51-72-11-911-001, 51-42-11-801 AND DRAWING D53474180.SDR AALA202012179003Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE. FOUND CRACK SHEAR PLATE STR 23L BETWEEN FR 69 AND FR 70 AT AFT GALLEY AREA. REPLACED SHEAR PLATE, IAW A321 SRM 51-72-11-911-001 AND DRAWING D53474180.SDR DALA2020121704130Intercostal · crackedCRACK INDICATION FOUND IN OPEN HOLE 1 LOCATED ON INTERCOSTAL AT DOOR STOP FITTING 7 POSITION FR 16 LT SIDE. CORRECTIVE ACTION: REPLACED INTERCOSTAL FR 16 LT AT DOOR STOP FITTING NR 7, AS PER SRM A320 51-72-11 AND ER/A 588914-14AD REV ORIGINAL.SDR CALA2020121601390Fitting · crackedSHEAR FITTING AT STA 540 RBL 32 40 IS CRACKED. 5866406-SPT REMOVED AND REPLACED SHEAR FITTING AT STA 540 RBL 32.40, IAW B737 -700 SRM 51-40-02 AND UNITED ECRA 5714-01179 REV ORIGINAL. SSFR REPORT, FORM 46-0024, ENTERED BY UAL INSPECTION U355204, 12/14/2 0 INSDR CALA2020121601389Fitting · crackedSHEAR FITTING AT STA 540 LBL 15.04 IS CRACKED. 5866364-SPT REMOVED AND REPLACED SHEAR FITTING AT STA 540 LBL 15.04, IAW B737 -700 SRM 51-40-02 AND UNITED ECRA 5714-01173 REV ORIGINAL. SSFR REPORT, FORM 46-0024, ENTERED BY UAL INSPECTION U355204 INSPECTION COSDR CALA2020121601388Fitting · crackedSHEAR FITTING AT STA 540 RBL 6.14 IS CRACKED. 5866404-SPT REMOVED AND REPLACED SHEAR FITTING AT STA 540 RBL 6.14, IAW B737-700 SRM 51-40-02 AND UNITED ECRA 5714-01177 REV ORIGINAL. SSFR REPORT, FORM 46-0024, ENTERED BY UAL INSPECTION U355204 12/14/20 INSPECTSDR CALA2020121601387Fitting · crackedSHEAR FITTINGS AT STA 540 LBL 54 60 IS CRACKED. 5866403-SPT REMOVED AND REPLACED SHEAR FITTING AT STA 540 LBL 54.60, IAW B737 -700 SRM 51-40-02 AND UNITED ECRA 57147-01176 REV ORIGINAL. SSFR REPORT, FORM 46-0024, ENTERED BY UAL INSPECTION U355204, 12/14/ 20 SDR CALA2020121601386Fitting · crackedSHEAR FITTING AT STA 540 LBL 6 14 IS CRACKED. 5866363-SPT REMOVED AND REPLACED SHEAR FITTING AT STA 540 LBL 6.14, IAW B737 -700 SRM 51-40-02 AND UNITED ECRA 5714-01172 REV ORIGINAL. DATA WAS TRANSCRIBED FROM 5866363, WORK ACCOMPLISHED BY V905004, INSPECTED BSDR CALA2020121601394Fitting · crackedSHEAR FITTING AT STA 540 RBL 15.04 IS CRACKED. 5866405-SPT REMOVED AND REPLACED SHEAR FITTING AT STA 540 RBL 15.04, IAW B737 -700 SRM 51-40-02 AND UNITED ECRA 5714-01178 REV ORIGINAL. SSFR REPORT, FORM 46-0024, ENTERED BY UNITED INSPECTION U355204, 12/1 4/20SDR CALA2020121601393Fitting · crackedSHEAR FITTING AT STA 540 RBL 54.60 IS CRACKED. SPT- 5866407 REMOVED AND REPLACED SHEAR FITTING AT STA 540 RBL 54.60, IAW B737 -700 SRM 51-40-02 AND UNITED ECRA 5714-01180 REV ORIGINAL. SSFR REPORT, FORM 46-0024, ENTERED BU UAL INSPECTION U355204 12/14/20 ACCSDR CALA2020121601392Fitting · crackedSHEAR FITTING AT STA 540 LBL 32 40 IS CRACKED. 5866365-SPT REMOVED AND REPLACE SHEAR FITTING AT STA 540 LBL 32.40 AND SUPPORT BRACKET, IAW B737-700 SRM 51-40-02 AND UNITED ECRA 5714-01174 REV ORIGINAL. SSFR REPORT, FORM 46-0024, ENTERED BY UAL INSPECTI ON U3SDR CALA2020121601391Fitting · crackedSHEAR FITTING AT STA 540 LBL 40.87 IS CRACKED. 5866402-SPT REMOVED AND REPLACED SHEAR FITTING AT STA 540 LBL 40.87, IAW B737 -700. SRM 51-40-02 AND UNITED ECRA 5714-01175 REV ORIGINAL. SSFR REPORT, FORM 46-0024, ENTERED BY UAL INSPECTION U355204, 12/14/ 20 SDR SWAA2021072937009Threshold · crackedFWD CARGO DOOR CUTOUT; AFT CORNER THRESHOLD CRACKED / FORWARD CARGO DOOR; AFT CORNER THRESHOLD WAS REPAIRED ON BACKSHOP W/O 41705/1400/0002 SERIAL NO 80005462 IAW SRM 53-30-15-2R-1 STEP 4B(4)SDR SWAA2021072937008Threshold · crackedFWD CARGO DOOR CUTOUT; FWD CORNER THRESHOLD CRACKED / FWD CARGO DOOR CUTOUT FORWARD CORNER THRESHOLD WAS REPAIRED ON BACK SHOP W/O 41705/1400/0001 SERIAL NO 8005461 IAW SRM 53-30-15-2R-1 STEP 4B(4)SDR SWAA2021071436891Angle · crackedCRACKED VERTICAL ANGLE ON CABLE GUARD INTERCOSTAL BS 693 RBL 1 WL 204-208. / REMOVED AND REPLACED VERTICAL ANGLE ON CABLE GUARD INTERCOSTAL BS693 RBL1 WL204-208 IAW SRM 51-40-02-0G-0 PARA 4(B) AND DWG 273A9110SDR SWAA2021052536967Gusset · crackedFORWARD CARGO STA 500D S-19R GUSSET BRACKET CRACK. / REMOVED AND REPLACED GUSSET AT FWD CARGO COMP. F.S 500D; S-19R; IAW B7377-700 DWG #143A7902 AND SRM 51-40-02-0G-0.SDR SWAA2021052536966Gusset · crackedFORWARD CARGO STA 500D S-19L GUSSET BRACKET CRACK. / REMOVED AND REPLACED CRACKED GUSSET AT FWD CARGO COMPT F.S. 500D; S19-L IAW B737-700 DWG # 143A7902 AND SRM 51-40-02-0G-0SDR IPXA2021011964636Pan · crackedINSPECTION TYPE: C3 CLG LT FWD DOOR FWD PAN (FRAME) CRACK. REMOVED AND REPLACED CLG LT FWD DOOR CRACKED PAN (FRAME), IAW DWG SE10520012 AND SRM 51-35-01 (MINOR).SDR IPXA2021011964628Intercostal · crackedINSPECTION TYPE: C3 LT MLG WHEEL WELL UPPER BRAKE ACCUMULATOR INTERCOSTAL CRACK. REMOVED AND REPALCED CRACKED INTERCOSTAL AT LT MLG WHEEL WELL BRAKE ACCUMULATOR, IAW SRM 51-33-01 AND DWG AEA0218 (MINOR).SDR SWAA2021011837212Strap · corrodedCORROSION, AFT CARGO COMPARTMENT BILGE FLOOR SUPPORT STRAP AT STA 727D+5; LBL 17 TO RBL 17 AND WL 153.5. FOUND EXFOLIETER CORROSION ON FLOOR SUPPORT STRAP AT STA 727D+5 OUT OF LIMITS, PER SRM 53-00-53-1A-2. INSTALLED NEW SUPPORT STRAP AT STA 727D+5, AS PER RSDR SWAA2021011536961Floor Support · corrodedCORROSION, AFT CARGO COMPARTMENT BILGE FLOOR SUPPORT FASTENER HOLE AT S-27R STA 847, MARKED DOT 60-010 RBL 13.8 AND WL 153.5. REMOVED CORRODED TRACK SUPPORT AND INSTALLED NEW TRACK SUPPORT FROM STA 759 TO STA 887 RBL 13.84 AND INSTALLED NEW SPLICE REPAIR AT SSDR SWAA2021011536958Floor Support · corrodedCORROSION, AFT CARGO COMPARTMENT LEFT SIDE FLOOR SUPPORT Z CHANNEL AT S-26L FROM STA 727C TO STA 807, MARKED DOT 60-006. REMOVED CORROSION AT LT 'Z' CHANNEL, AFT CARGO COMPARTMENT FROM STA 727+10 TO STA 847. FOUND OUT OF LIMITS, PER SRM 53-00-53-1A-2 AND FABSDR R61A2020123100956Door Sill · corrodedWHILE AC WAS IN HEAVY CHECK, FWD CARGO DOOR CUTOUT LOWER SILL BEAM CORRODED BETWEEN FR 24-FR 27. FOUND WITHIN LIMITS, IAW ETD2020-170-035912. AC REMAINS IN CHECK.SDR SWIA202054893Floor Support · corrodedCORROSION AFT WET AREA RT SIDE FLOOR SPLICE CORRODED FRAMES 89/90. C-CHECK RO 12/27/2020. REMOVED AND REPLACED FLOOR SPLICE BETWEEN FRAMES 89-90 (RT SIDE), REF SRM.SDR A6WA202012227471Floor Support · corrodedPRESSURE FLOOR ANGLE AT FS 436+6 TO FS 437.15+5, LBL 36 TO LBL 43 HAS CORROSION. AIRCRAFT REMOVED FROM SERVICE. REMOVED CORROSION FROM FLOOR ANGLE (3 EA) POSITIONS AT FS 436+6 TO FS 437.15+15, LBL 36 TO LBL 43 REWORKED DIMENSIONS (P1)=4.5 W X 1.7 L, (P2)=0.8SDR FDEA202012153163Floor Support · crackedRT AFT FUSELAGE, AFT CARGO BS 1576 RBL 78, MAIN CARGO DECK FLOOR SUPPORT CRACKED. REMOVED AND REPLACED THE RIGHT AFT FUSELAGE MAIN CARGO DECK FLOOR SUPPORT SPLICE ANGLE AT STA 1576 AND RBL 78, IAW BAC DWG 146T5650, REV C AND B767 SRM 51-40-02-0G.SDR FDEA202012153162Floor Support · crackedLT AFT FUSELAGE, AFT CARGO BS 1576 LBL 78, MAIN CARGO DECK FLOOR SUPPORT CRACKED. REMOVED AND REPLACED THE LEFT AFT FUSELAGE MAIN CARGO DECK FLOOR SUPPORT SPLICE ANGLE AT STA 1576 AND LBL 78, IAW BAC DWG 146T5650, REV C AND B767 SRM 51-40-02-0G.SDR EE4Y2020121511965Floor Support · crackedUPPER FUSELAGE, MAIN CABIN FROM BS 312 TO BS 328 AT LBL 48", INTERCOSTAL WITH CRACK. IT WAS REPAIRED, AS PER B737-400 SRM INSTRUCTIONS REF JOB: A1J185 NRI: 2-41.SDR EE4Y2020121511961Intercostal · crackedLOWER FUSELAGE, FORWARD CARGO COMPARTMENT AT BS 500F BETWEEN STRINGER 25RH AND STRINGER 26RH, INTERCOSTAL ANGLE WITH CRACK. NOTE: IT WAS REPAIRED, AS PER B737-400 SRM INTRUCTION (REF: JOB: A1J185 NRI: 1-21).
SDR SWIA202062547None · damagedCOMPLY WITH REO 601R-53-41-1116 REPAIR & REINFORCEMENT FOR FS 559.00 LWR CAP ANGLES BL 9.00 & 18.00 LHS & RHS (C-CHECK- RO 11/11/21) COMPLIED WITH REO 601R-53-41-1116 REV. C DATED 2017-03-09 REPAIR & REINFORCEMENT FOR FS 559.00 LWR CAP ANGLES BL 9.00 & 18.SDR SWAA2021051236484Skate Angle · chafedR/H AFT SKATE ANGLE CHAFFED BS 1028; RBL 12; WL 308; / REMOVED & REPLACED R/H AFT SKATE ANGLE BS1028 RBL 12 WL 308 IAW SRM'S 51-40-02-0G-0; SRM 51-40-05-0G-0; SRM 51-40-08-0G-0 DWG 148A8300 SHT 1 REV C & AMM 51-21-99 56304U 22DEC20SDR SWAA2021051236483Skate Angle · chafedL/H AFT SKATE ANGLE CHAFFED BS 1028; LBL 12; WL 308 / REMOVED & REPLACED L/H AFT SKATE ANGLE BS1028 LBL12 WL308 IAW SRM'S 51-40-02-0G-0; SRM 51-40-05-0G-0; SRM 51-40-08-0G-0; DWG 148A8300 SHT 1 REV C & AMM 51-21-99 56304U 22DEC20SDR SWAA2021021136614Support Bracket · corrodedFWD CARGO COMPT STA 500D LOWER CENTER SUPPORT BRACKET WITH SURFACE CORROSION (MK) WL 156.5; FROM STR26R TO STR26L / REMOVED AND REPLACED NEW BRACKET STA500D ;STR 26R TO STR 26L AT FWD CARGO IN REF (B737-700 SRM 51-40-02-0G-0 AND DRAWING 143A9481.