JASC 5320
Service difficulty reports · 216,415
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR REXA2019041700592Support Angle · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORTS ANGLE IN STA. FS= 346 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX) SUMMARY: LEVEL CORROSION 2; PROTECTION PLATE SUPPORTS ANGLE IN STASDR REXA2019041700591Support Angle · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORTS ANGLE IN STA. FS= 339 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX) SUMMARY: LEVEL CORROSION 2; PROTECTION PLATE SUPPORTS ANGLE IN STASDR REXA2019041700590Support Angle · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORTS ANGLE IN STA. FS= 329 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX) SUMMARY: LEVEL CORROSION 2; PROTECTION PLATE SUPPORTS ANGLE IN STASDR REXA2019041700589Support Angle · corrodedAWR; [ TASK R53520 STEP 7 ]; INITIAL INSPECTION: CORROSION ON PROTECTION PLATE SUPPORTS ANGLE IN STA. FS= 322 BETWEEN 41RBL TO 44RBL AT GALLEY SERVICE DOOR LOWER SILL, FWD WET AREA. (W1) (CPAX) LEVEL CORROSION 2; PROTECTION PLATE SUPPORTS ANGLE IN STA. FS= 322SDR SWAA2019050632366Floor Support · crackedFLOOR SUPPORT CRACKED BETWEEN BS. 312 TO BS. 328, LBL 45. R&R FLOOR SUPPORT PER DWG AND SRM.SDR ASAA2019041729228Transition Panel · damagedAFT PIT RT TRANSITION PANEL HAS ELONGATED HOLES AND MISSING NUTPLATES FROM STA 727 TO 767. GROUNDED - YES. REMOVED AND REPLACED AFT PIT RT TRANSITION PANEL IAW SRM 51 40 02 0G 0.SDR ASAA2019041729226Door Sill · corrodedFWD CARGO DOOR CUTOUT LWR SILLWEB HAS CORR. GROUNDED - YES. REMOVED AND REPLACED FWD CARGO DOOR CUTOUT LWR SILL WEB IAW SRM 51 40 02 0G 0 AND 51 40 05 0G 0 W.75 O .050 R .039 L 3.20 D .011.SDR ASAA2019041729222Transition Panel · damagedAFT PIT LT TRANSITION PANEL HAS ELONGATED HOLES AND MISSING NUTPLATES FRM STA 727 TO 787. GROUNDED - YES. REMOVED AND REPLACED AFT PIT LT TRANSITION PANEL IAW SRM 51 40 02 0G 0.SDR FDEA201904170820Floor Support · crackedMAIN DECK COMPARTMENT AFT FLOOR PANEL SUPPORT FOUND CRACKED AT STATION 1921 X = 25 MAIN DECK COMPARTMENT AT STATION 1921 X = 25 CRACKED AFT FLOOR PANEL SUPPORT REMOVED AND REPLACED FROM STATION 1887 TO STATION 2007 X = 25 AS PER SRM 51-31-01-0G. AFT FLOOR PANESDR FDEA201904170819Floor Support · crackedMAIN DECK COMPARTMENT AFT FLOOR PANEL SUPPORT FOUND CRACKED AT STATION 1887 X = 56 MAIN DECK COMPARTMENT CRACKED AFT FLOOR PANEL SUPPORT AT STATION 1887 X = 56 REMOVED AND REPLACED FROM STATION 1887 TO STATION 2007 X = 56 AS PER SRM 51-31-01-0G. AFT FLOOR PSDR CALA2019050300677Floor Support · corroded(B757-06-3-0243) AFT CARGO COMP. FLOOR STR AT APPROX FS1330 RBL 7.55 NUT PLATE HAS CORROSION. 56-012. REF NR 0053578. REMOVED DAMAGED AREA OF STRINGER @ STA 1330 RBL 7.55, FABBED REP AIR -7 CHANNEL AND INSTALLED -7 IAW SRM 53-00-53 REPAIR 1. SEE SUPPLEMENT 855SDR ASAA2019041729207Intercostal · crackedFWD PIT INTERCOSTAL BETWEEN RT STA 500 AND 520 STR 24 IS CRACKED. GROUNDED - YES. REMOVED AND REPLACED INTERCOSTAL IAW SRM 51 40 02 0G 0.STRUCTURAL.SDR SWAA2019050132176Shield · corrodedAFT CARGO BAY FLOOR TO SIDEWALL SHIELD CORRODED BETWEEN BS. 767 TO BS. 787+7, RBL 22. REPAIRED SHIELD IAW DWG AND SRM.SDR SWAA2019042531969Floor Support · crackedFORWARD CARGO BAY INTERCOSTAL AT BS 500C TO BS 500D LBL 24 WL 156 IS CRACKED REMOVED AND REPLACED FORWARD CARGO BAY INTERCOSTAL IAW SRMSDR SWAA2019042531968Floor Support · crackedFORWARD CARGO BAY INTERCOSTAL AT BS 400 TO BS 420, LBL 24, WL 156 IS CRACKED / REMOVED AND REPLACED INTERCOSTAL PER SRMSDR AALA2019042539014Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOOR SUPPORT AT FR 90 AND LBL 34. REPLACED FLOOR SUPPORT PER SRM 51-75-16.SDR SWAA2019042431971Support · corrodedR/H FLOOR TO SIDEWALL SUPPORT STA 867-887, RBL 22, WL 156. / REMOVED AND REPLACED SUPPORT IAW SRM 51-40-02SDR A6WA201904196568Angle · crackedPREVIOUS REPAIR ANGLE AFT FACE OF STA 280 AND RBL 12 CRACKED. REPLACEDSDR DALA2019041802527Floor Support · corrodedCORROSION LEVEL: 2. CORROSION FLOOR BEAM +Y765 LOCATED BETWEEN FR12 TO FR24 AT FWD GALLEY AREA (1 EA). REPLACED FLOOR BEAM +Y765 LOC. BTW FR12 TO FR24 AT FWD GALLEY AREA (1E/A) ASPER SRM A319 51-72-11 AND DWG D53112812.SDR DALA2019041802526Floor Support · corrodedCORROSION LEVEL: 2. CORROSION FLOOR BEAM +Y1292 LOCATED BETWEEN FR12 TO FR24 AT FWD GALLEY AREA (1 EA). REPLACED FLOOR BEAM +Y1292 LOC BTW FR12 TO FR24 AT FWD GALLEY AREA (1E/A) ASPER A319 SRM 51-72-11 AND DRAWING D53110920.SDR DALA2019041802525Floor Support · corrodedCORROSION LEVEL: 2. CORROSION FLOOR BEAM +Y765 LOCATED BETWEEN FR66 TO FR70 AT AFT GALLEY AREA (1 EA). REPLACED FLOOR BEAM +Y765 LOC. BTW FR66 TO FR70 AT AFT GALLEY AREA (1E/A) ASPER A319 SRM 51-72-11 AND DRAWING D53472780.SDR DALA2019041802524Floor Support · corrodedCORROSION LEVEL: 2. CORROSION FLOOR BEAM +Y765 LOCATED BETWEEN FR64 TO FR66 AT AFT GALLEY AREA (1 EA). REPLACED FLOOR BEAM +Y765 LOC. BTW FR64 TO FR66 AT FWD GALLEY AREA (1E/A) ASPER A319 SRM 51-72-11 AND DRAWING 10ND1474.SDR DALA2019041802523Floor Support · corrodedCORROSION LEVEL: 2. CORROSION FLOOR BEAM +Y765 LOCATED BETWEEN FR64 TO FR66 AT AFT GALLEY AREA (1 EA). REPLACED FLOOR BEAM +Y765 LOC. BTW FR64 TO FR66 AT FWD GALLEY AREA (1E/A) ASPER A319 SRM 51-72-11 AND DRAWING 10ND1474.SDR DALA2019041802528Floor Support · corrodedCORROSION LEVEL: 2. CORROSION FLOOR BEAM +Y254 LOCATED BETWEEN FR12 TO FR24 AT FWD GALLEY AREA (1 EA). REPLACED FLOOR BEAM +Y254 LOC BTW FR12 TO FR24 AT FWD GALLEY AREA ASPER A319 SRM 51-72-11 AND DRAWING D53110984.SDR AALA201904187011Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON CENTER SILL SHAPE FITTING BETWEEN FR 66 AND FR 68 AT S23R. REPLACED CENTER SILL SHAPE FITTING PER SRM 51-72-11.SDR AALA201904187007Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LOWER SILL BETWEEN FR 66 AND FR 68 AT S23R. REPLACED LOWER SILL PER SRM 51-72-11.SDR AALA201904187004Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT WET AREA FLOOR INTERCOSTAL AT NS 950 AND LBL 50. REPLACED INTERCOSTAL PER SRM 51-40-02.SDR DALA2019041702504Floor Support · corrodedCORROSION FLOOR BEAM -Y1162 LOC FROM FR 68 TO FR 69 AT AFT GALLEY AREA. REPLACED FLOOR BEAM -Y1162 LOCATED FROM FR68 TO FR69 AT AFT GALLEY AREA AS PER A319 SRM 51-72-11 AND DRAWING D53472780, ISSUE "D" RELEASE DATE:26-APR-18, D53474180.SDR SWAA2022030727347Strip · corrodedAFT PIT STA 727D+5 FLOOR BOARD TRANSITION STRIP CORRODED / AFT CARGO STA 727D+5 FLOOR BOARD TRANSITION STRIP DOES NOT HAVE ENTIRES IN SRM; PART REPAIRED BY REPLACEMENT. REPLACED -8 TRANISTION STRAP ON TABLE PER DWG 146Q9401 REV. C. TRANISTION STRIP INSTALLED OSDR SWAA2022030727350Strip · corrodedAFT PIT STA 767+4 FLOOR BOARD TRANSITION STRIP CORRODED / REPLACED 767+4 FLOORBOARD TRANSITION STRIP ON TABLE P/N: 146A9401-16; IAW B737 AIPC 53-42-11-30 SHEET 0003 ITEM B.SDR SWAA2022030727355Strip · corrodedAFT PIT STA 827+14' NUTPLATE STRIP UNDER THRESHOLD WEB; ANGLE CORRODED / REMOVED CORROSION ON NUTPLATE STRIP THRESHOLD WEB AT STA 827+14; SRM HAS NO LIMITS IN THIS AREA; FABRICATED AND INSTALLED NEW NUTPLATE STRIP 146A8128-12 IAW AAR EA 190325 IR AND SWA EA 1-SDR SWAA2022030727356Strip · corrodedAFT PIT STA 787+12' NUTPLATE STRIP UNDER THRESHOLD WEB; ANGLE CORRODED / REMOVED CORROSION ON AFT PIT STA 787+12 NUTPLATE STRIP UNDER THRESHOLD WEB IAW B737-700 SRM 51-10-02-0G-0. ORIG THICKNESS .040' REMOVED .010'. MAT REMAINING .030'. NO LIMITS FOUND. CONSIDSDR SWAA2022030727365Bracket · crackedAFT PIT STA 867 LBL 12 ANGLE UNDER BKHD STANTION CRACKED / REMOVED AND REPLACED -114 BRACKET ANGLE AT STA 867 LBL 12 PER SRM 51-40-02-0G-0 AND AIPC 53-42-51-06SDR SWAA2022030727366Angle · corrodedFWD CARGO PIT; STA 500D; STR 26L - 26R; AFT BULKHEAD LOWER ATTACH ANGLE UPPER SURFACE HAS MULTIPLE AREAS OF CORROSION / REMOVED CORROSION ON AFT BLKD LWR ATTATCH ANGLE AT STA 500D IAW SRM 51-10-020-0G-0. VERFIED REMOVAL W/10X MAG GLASS. ORG T=.071 REM T=.052 LSDR SWAA2022030727364Shield · corrodedFWD CARGO PIT; STA 420-440; R/H SIDE SHIELD ABOVE STR 26R; MULTIPLE AREAS OF BARE METAL AND EVIDENCE OF CORROSION AT AFT END UPPER SURFACE / REMOVED CORROSION FROM R/H SIDE SHIELD ABOVE STR 26R IAW SRM 51-10-02-0G-0. VERIFIED REMOVAL W/10X MAGNIFING GLASS. ORGSDR SWAA2022030727361Shield · corrodedFWD CARGO PIT; STA 480+12-500A; R/H SIDE SHIELD ABOVE STR 26R; MULTIPLE AREAS OF BARE METAL / CORROSION / REMOVED CORROSION FROM R/H SIDE SHIELD ABOVE STR 26R IAW SRM 51-10-02-0G-0. VERIFIED REMOVAL W/10X MAGNIFING GLASS. ORG T=.040 REM T=.031 LOSS=.009 MAX ALSDR SWAA2022030727354Strap · corrodedAFT PIT THRESHOLD WEB INBD FLOOR STRAP AT STA 807+2' CORRODED AROUND NUTPLATE HOLE / REMOVED CORROSION AT AFT PIT THRESHOLD WEB STRAP AT STA 807+2 IAW SRM 51-10-02-0G-0. VERIFIED MATERIAL LIMITS. ORIG .100' LOSS .027' REMAINING .077'. FOUND TO BE OUT OF LIMITSSDR SWAA2022030727351Shield · corrodedAFT PIT STA 767 TO 787 RH FWD SHILED CORRODED TOP AND BOTTOM / REMOVED DAMAGE AT AFT PIT STA 767-787 RH FWD SHIELD IAW B737-700 SRM 51-02-02-0G-0. VERIFIED MATERIAL LOSS .050'. ORIG MAX .050' MAT. REMAINING .000' OUT OF LIMITS IAW SRM 53-00-53-1A-2 FIGURE 163.SDR SWAA2022030703042Strap · corroded***CORROSION*** ON ACB FLOOR T-STRAP AT STA 767+6 WL157 RBL 21 - LBL 22 / REMOVED CORRODED T-STRAP IN ACB STA 767+6; WL 157; RBL 21 - LBL 22 IAW SRM 51-40-02; THE TEMP LOCATED REPLACEMENT T-STRAP DURING CARGO FLOOR PANEL INSTALLATION. 80570U 23APR19 T-STRAP RESDR SWAA2022022527352Angle · corrodedAFT PIT STA 767 TO 787 RH ANGLE ON BOTTOM OF FWD SHIELD ATTACHED TO INTERCOSTAL CORRODED / REMOVED CORROSION ON AFT PIT STA 767-787 RH ANGLE ON BOTTOM OF FWD SHIELD IAW SRM 51-10-02-0G-0. FOUND TOBE OUT OF LIMITS. NON .060' LOSS .015' REMAINING .045' IAW SRM 5SDR SWAA2019052132831Attach Angle · crackedCENTER SECTION WING BOX AT STA 663, LBL 45, O/B SIDE OF THE FLOORBEAM FITTING HAS A CRACK ON THE LOWER ATTACH ANGLE. REPAIRED ANGLE PER SWA EA.SDR WVER2019051421Support Angle · corrodedSERVICE DOOR CUT OUT MOUNTING ANGLE AND THRESHOLD BRACKET SUPPORT ANGLES ARE CORRODED.SDR SWAA2019051432613Threshold · corrodedAFT PIT THRESHOLD WEB CORRODED. R&R THRESHOLD WEB IAW SRM AND DWG.SDR SWAA2019051032527Gusset · crackedFORWARD CARGO PIT SIDEWALLS GUSSET CRACKED AT BS. 500D, STR. 19R. R&R GUSSET IAW SRM AND DWG.SDR SWAA2019051032526Gusset · crackedFORWARD CARGO PIT SIDEWALLS GUSSET CRACKED AT BS. 500D, STR. 19L. R&R GUSSET IAW SRM AND DWG.SDR SWAA2019050932501Angle · corrodedFORWARD CARGO PIT RT ZEE ANGLE UPPER SURFACE CORRODED BETWEEN BS. 500A TO BS. 500D. R&R Z ANGLE IAW SRM & DWG.SDR SWAA2019050732371Threshold · corrodedFORWARD CARGO PIT DOOR SURROUND, THRESHOLD WEB UPPER SURFACE CORRODED BETWEEN BS. 440 TO BS. 480+12. R&R WEB IAW SRM AND DWG.SDR FDEA201904160805Floor Support · corrodedMAIN DECK COMPARTMENT AFT FLOOR PANEL SUPPORT FOUND WITH CORROSION AT STATION 1991 X = - 25 MAIN DECK COMPARTMENT AT AFT FLOOR PANEL SUPPORT STATION 1991 X = -25 CORROSION REMOVED AND FOUND TO EXCEED LIMIT AS PER SRM 53-00-00-2R FIGURE 206 CORRODED FLOOSDR FDEA201904160804Floor Support · corrodedMAIN DECK COMPARTMENT AFT FLOOR PANEL SUPPORT FOUND WITH CORROSION AT STATION 1981 X = - 02 . MAIN DECK COMPARTMENT AFT FLOOR PANEL SUPPORT AT STATION 1981 X = - 02 , CORROSION REMOVED AND FOUND TO EXCEED LIMIT AS PER SRM 53-00-00-2R FIGURE 206 . CORRODSDR FDEA201904160803Floor Support · corrodedMAIN DECK COMPARTMENT AFT FLOOR PANEL SUPPORT FOUND WITH CORROSION AT STATION 1961 X = - 56 MAIN DECK COMPARTMENT AFT FLOOR PANEL SUPPORT AT STATION 1961 X = - 56 CORROSION REMOVED AND FOUND TO EXCEED LIMIT AS PER SRM 53-00-00-2R FIGURE 206 . CORRODED F
Back to JASC 5320