JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023081779276Support · corrodedCORROSION LOWER SILL BTW BS 787 TO BS 847 RBL 24 WL 159 AFT CARGO COMPARTMENT 2023-447612<[01] EQUIPMENT P/N 45MG; S/N 221859911; DUE DATE 07-NOV-23 WAS USED;[02] REMOVED CORROSION AND EVALUATE REWORK LOWER SILL BTW BS 787 TO BS 847 RBL 24 WL 159 AFT CARGO COMSDR SWAA2023081578915Scuff Plate · crackedAFT CARGO COMPT FWD DOOR SCUFF PLATE IS CRACK P/N 146A8341-7<[01] AFT CARGO DOOR COMPT FWD SCUFF PLATE P/N 146A8341-7 WAS REPAIRED BY J.L WELDING INC. CUSTOMER ORDER # 414134. INSTALLATION TO SCUFF PLATE TO BE ACCOMPLISH ON TASKCARD TTG8R007SXFW.;[02] VERIFIEDSDR DALA2023071905829Unknown · unknownSHIP 667 CORROSION ON FLOOR STRUCTURE SURFACE BTW STA 760 TO STA 740 BESIDE CUSP WEB RH SIDE (W2). CORRECTIVE ACTION: SUMMARY OF NRC 00631: FLOOR SUPPORT STA 760 BESIDE CUSP WEB RH SIDE (W2) WAS REPLACED PER B757-200 SRM. (2869536)SDR DALA2023071905828Unknown · unknownSHIP 0687 CORROSION ON RH SIDE PLATE (OUT OF LIMIT) FROM STA. 1460 TO 1480 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00774: SIDE PLATE AT STA 1440 TO STA 1520 + 1 0 RH SIDE WAS REPLACED PER B757-200 SRM 51-40. (2869236)SDR DALA2023071905826Unknown · unknownSHIP 6703 MAIN CABIN FLOOR BEAM HAS A CRACK IN THE UPPER CHORD AT RADIUS BS.700 APROX RBL.25.5 (VIEW FROM FWD CARGO CEILING). CORRECTIVE ACTION: REPAIRED THE MAIN CABIN FLOOR BEAM AT STA 700 RBL 24 TO 26 IAW DELTA ERA 610023-14. (2868904)SDR DALA2023071905825Unknown · unknownSHIP CORROSION ON PREVIOUS REPAIRED DOBLER FLOOR STRINGER RBL 2.90,RBL 7.55, RBL 10.45 , LBL 2.90, LBL 7.55 ,LBL 10.45 BTW STA 1500 TO STA 1520 AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00099 REPAIR DOBLER ON FLOOR STRINGER RBL 2.90,RBL 7.55,SDR DALA2023071905824Unknown · unknownSHIP 0687 INITIAL INSPECTION: CORROSION ON SIDE PLATE STA 740 S-27LH AT FWD CARGO. CORRECTIVE ACTION: SUMMARY OF NRC 00082: SIDE PLATE BETWEEN STA 645 TO STA 765 LH AT FWD CARGO WAS REPAIRED PER B757-200 SRM 53- 00 (2868017)SDR AALA202307186554Angle · crackedAIRCRAFT IN BASE MAINTENANCED: CRACK IN WING CENTER SECTION REAR SPAR VAPOR BARRIER ATTACH ANGLE LOCATED AT BS 727, WL 171.5 AND RBL 12. REPAIRED ANGLE PER SRM 57-10-10-2R-5.SDR DALA2023071705780Unknown · unknownCRACK ON CUSP MEMBRANE LOWER SURFACE ON STA Y=645 AND X=-44 AT CPAX. SUMMARY OF NRC 421: CUSP MEMBRANE LOWER SURFACE ON STA Y=645 AND X=-44 AT CPAX WAS REPAIRED PER B717-200 SRM 53-00-55-2R REPAIR 4 FIGURE 203 AND (ET) HFEC INSPECTION WAS PERFORMED. NO CRACKS SDR DALA2023071705779Unknown · unknownCORROSION OUT OF LIMITS ON LH MEMBRANE WEB UPPER, LOWER SURFACE BTW STA 463 TO STA 466 AT PAX CABIN IN REF NRC 0353. SUMMARY OF NRC 00657: CORROSION LEVEL 2. CORROSION OUT OF LIMITS ON LH MEMBRANE WEB UPPER/LOWER SURFACE BTW STA 463 TO STA 466 AT PAX CABIN WASSDR SWAA2023081778810Support Angle · crackedCRACK ON SUPPORT ANGLE LOCATED CEILING AREA BS 867 BTW STR 2R TO STR 3R AT PASSENGER CABIN 2023-447553<[01] REPLACED SUPPORT ANGLE LOCATED CEILING AREA BS 867 BTW STR 2R TO STR 3R AT PASSENGER CABIN IAW B737-700 SRM-51-40-02 AND DWG-146A7901 REV: -;[02] REPLACSDR AALA202307188740Bracket · brokenAIRCRAFT WAS GROUNDED: FLIGHT DECLARED AN EMERGENCY AND DIVERTED TO IAD, AFTER TAKEOFF, GEAR RETRACTION HYDRAULIC GREEN RESERVOIR LOW LEVEL, FLIGHT LANDED AT IAD WITHOUT INCIDENT AND TAXIED TO GATE ON OWN POWER. MAINTENANCE FOUND THE GREEN SYSTEM HYDRAULIC PIPSDR DALA2023071805808Unknown · unknown(LOG 2867807)FWD CARGO BAY L/H ZEE CHANNEL HAS MULTIPLE LOCATIONS OF CORROSION FROM STA 500C TO 500L) DUE LH ZEE CHANNEL BETWEEN BS 500A AND BS 500C HAS FASTENER HOLES MISALIGNED WITH THE BAFFLE. REPAIRED L/H ZEE CHANNEL FROM STA 500D+6-STA. 500B+10 IAW B737 SSDR DALA2023071805815Floor Support · corroded(LOG 2867076) MAIN CABIN FLOOR INTERCOSTAL HAS CORRODED UPPER SURFACE BS 294.5 TO BS 312 AT LBL 11. REMOVED AND REPLACED INTERCOSTAL IAW B737 SRM 51-40-02-0G.SDR AALA202307188385Support Strap · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON G1 GALLEY FLOOR SUPPORT STRAP LOCATED AT BS 260 AND RBL 41.50. REPLACED SUPPORT STRAP PER SRM 51-40-02.SDR AALA202307180132Intercostal · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON G1 GALLEY FLOOR INTERCOSTAL LOCATED AT BS 290 AND RBL 41.80. REPLACED INTERCOSTAL PER SRM 51-40-02.SDR AALA202307186782Unknown · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LOWER SILL INNER CHORD LOCATED FROM BS 290 TO BS 315 AT RBL 59.5. REPLACED CHORD PER SRM 51-40-02.SDR DALA2023071705776Unknown · unknownCRACK ON INTERCOSTAL FROM STA Y=1002 TO STA Y=1022 AND X=0 AT PAX CABIN. SUMMARY OF NRC 00438: INTERCOSTAL FROM STA Y=1002 TO STA Y=1022 AND X=0 AT PAX CABIN WAS REPAIRED PER B717-200 SRM 51-70-11-2R PROCEDURE 1 REPAIR 1 PAR 4 FIGURE 201 AND 51-41-05-0G. (LP #SDR SWIA20230901001Unknown · corrodedMAIN AVIONICS BAY FS364.00 FRAME CORRODED AT LBL 1.0 (C-CHECK RO 8/31/2023) INSTALLED NEW FS364.00 FRAME FROM STR 24L TO STR 24R REF. DRWG SH670-32050 REV. J, CRJ 700 SRM 51-42-06-001-001-A01 AND CRJ 700 SRM 53-21-23-201-008-A01SDR SWAA2023081778580Intercostal · crackedCRACK ON WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 328 TO BS 344 LBL 46.5 AT FWD GALLEY AREA 2023-447482<[01] TOOLS USED: TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 01-FEB-24; TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 1SDR SWAA2023081778581Intercostal · crackedCRACK ON WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 312 TO BS 328 LBL 46.5 AT FWD GALLEY AREA 2023-447483<[01] TOOLS USED: TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 01-FEB-24; TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 1SDR SWAA2023081778583Intercostal · crackedCRACK ON WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 294.5 TO BS 312 LBL 27 AT FWD GALLEY AREA 2023-447485<[01] REPLACED WEB-INTERCOSTAL LOCATED FLOOR STRUCTURE BETWEEN BS294.5 TO BS312 AND LBL27 FWD GALLEY AREA IAW B737-700 SRM:51-40-02 AND DWG: 141A5400 RSDR SWAA2023081778584Intercostal · crackedCRACK ON WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 294.5 TO BS 312 RBL 15 AT FWD GALLEY AREA 2023-447486<[01] EDDY CURRENT EQUIPMENT P/N: NORTEC500D; S/N: N500X12101V022237; DUE DATE: 26-JAN-24.;[02] PERFORMED PERMANENT REPAIR ON WEB INTERCOSTAL LOCATED FSDR SWAA2023081778585Intercostal · crackedCRACK ON WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 312 TO BS 328 RBL 32 AT FWD GALLEY AREA 2023-447487<[01] TOOLS USED: TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 01-FEB-24; TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 142SDR SWAA2023081778586Intercostal · crackedCRACK ON WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 277 TO BS 294.5 RBL 1 AT FWD GALLEY AREA 2023-447488<[01] TOOLS USED: TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 01-FEB-24; TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 14SDR SWAA2023081778589Intercostal · crackedCRACK ON WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 277 TO BS 294.5 LBL 32 AT FWD GALLEY AREA 2023-447491<[01] REPLACED WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 277 TO BS 294.5 LBL 32 AT FWD GALLEY AREA. IAW B737-700 SRM 51-40-02 AND DWG 141A5400 SHESDR SWAA2023081778590Intercostal · crackedCRACK ON WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 344 TO BS 360 LBL 12 AT FWD GALLEY AREA 2023-447497<[01] TOOL USED: EDDY CURRENT INSTRUMENT P/N: NORTEC 600D; S/N: 220272512; DUE DATE: 17-DEC-23;[02] PERFORMED PERMANENT REPAIR ON WEB INTERCOSTAL LOCATEDSDR SWAA2023081778592Intercostal · crackedCRACK ON WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 344 TO BS 360 BL 0 AT FWD GALLEY AREA 2023-447498<[01] TOOL USED: EDDY CURRENT INSTRUMENT P/N: NORTEC 600D; S/N: 220272512; DUE DATE: 17-DEC-23;[02] TOOL USED: EDDY CURRENT INSTRUMENT P/N: NORTEC 600D; S/SDR SWAA2023081778797Support Angle · crackedCRACK ON SUPPORT ANGLE LOCATED BTW BS 291.5 TO BS 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA 2023-447516<[01] REPLACED SUPPORT ANGLE LOCATED BTW BS 291.5 TO BS 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND DWG 141A8310 SHEET 25 REV : SSDR SWAA2023081778587Support Angle · crackedCRACK ANGLE - SUPPORT LOCATED BS727A TO BS727E AT LBL51 AFT CARGO COMPARTMENT 2023-447481<[01] REMOVED FASTENER COMMON TO ANGLE - SUPPORT LOCATED BS727A TO BS727E AT LBL51 AFT CARGO COMPARTMENT IAW B737-700 51-40-02 AND PERFORMED VISUAL INSPECCIÏ¿½N IAW B737-7SDR SWAA2023081778795Support Angle · corrodedCORROSION ON SUPPORT ANGLE LOCATED BTW BS 312 TO BS 344 AT LEVEL STR 17R RBL57 WL 208.1 AT FWD GALLEY AREA 2023-447502<[01] ULTRASONIC EQUIPMENT USED P/N: 45MG; S/N:221861811 AND DUE DATE: 08-NOV-23.;[02] REPLACED NEW SUPPORT ANGLE LOCATED BTW BS 312 TO BS 344SDR SWAA2023081778796Support Bracket · corrodedCORROSION ON SUPPORT BRACKET LOCATED BS 312 RBL 54 AT LEVEL STR 17L AT FWD GALLEY AREA 2023-447504<[01] REPLACED SUPPORT BRACKET LOCATED BS 312 RBL 54 AT LEVEL STR 17L AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND SRM B737-700 SRM 51-10-02. TOOK MEASURE OF SDR SWAA2023081578553Retainer · corrodedCORROSION ON SEAL RETAINER BS227 AFT SIDE OF BULKHEAD RBL3 WL161<[01] SEAL RETAINER @ BS227 AFT SIDE OF BLKHD WL 161 RBL3 WAS FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED PART IAW SRM 51-40-02 AND DWG #141A7410.;[02] VERIFIED CORRECTIVE ACTION 1 AND MEASURESDR SWAA2023081478784Structure · corrodedCORROSION ANGLE FLOOR STRUCTURE LOCATED BS 294 TO BS 328 AT FWD GALLEY AREA 2023-444050<[01] ULTRASONIC THICKNESS GAGE P/N:45MG; S/N: 221859911; DUE DATE: 07-NOV-23.;[02] REPLACED ANGLE FLOOR STRUCTURE LOCATED BS 294 TO BS 328 AT FWD GALLEY AREA I.A.W B737-700SDR SWAA2023080778923Angle · crackedB.S. 663 LOWER COMPOSITE BULKHEAD UPPER ATTACH ANGLE IS CRACKED AT L.B.L. 45; W.L. 165.<[01] ACCOMPLISHED REMOVE AND REPLACE BS 663 LOWER COMPOSITE BULKHEAD UPPER ATTACH ANGLE ON CUSTOMER CARD # TTG8Q00M7WFD (FUSELAGE 5026);[02] VERIFIED CORRECTIVE ACTION 1 ANSDR SWAA2023080778615Scuff Plate · crackedFWD CARGO BAY FWD CORNER SCUFF PLATE CRACKED<[01] WELDED CRACKED RADIUS ON FWD CARGO BAY; FWD CORNER SCUFF PLATE USING ER4043 ALUMINUM FILLER ROD LOT NUMBER 1131216 PER SRM 53-30-15-2R-1 PARAGRAPH 4.B. (2) AND (4). REPAIR STILL REQUIRES A DYE PENETRANT INSPECTSDR SWAA2023080478249Floor Support · crackedCRACK WEB - INTERCOSTAL BTW BS847 TO BS867 WL208 FLOOR LEVEL AT AFT CARGO COMPARTMENT 2023-431308<[01] OPEN FAULT HAS AN ERROR AND IS BEING CORRECTED BY RAISING A NEW FAULT; SEE [TTG8Q00M7MDZ];[02] CORRECTED STEP 1:FAULT SOLVED IN OTHER FAULT DUE TO REPLACED PSDR SWAA2023080478569Support Angle · crackedCRACK SUPPORT ANGLE LOC. BS 847 BETWEEN BS867 LBL 21 AT AFT GALLEY AREA AT PASSENGER CABIN 2023-431309<[01] REPLACED SUPPORT ANGLE LOC. BS 847 BETWEEN BS867 LBL 21 AT AFT GALLEY AREA AT PASSENGER CABIN IAW B737-700 SRM 51-40-02 AND SRM 51-10-02 ITEM 9 AND DWG SDR YENA2023071800817Unknown · unknownDURING HEAVY MAINTENANCE: CORROSION INTERNAL STRUCTURE WEB LOCATED BTW FR 69 AND FR70 AT LEVEL STR 23R AT AFT GALLEY AREA (CPCP RELATED MPD TASK 534195-01; (RESOLVED ON W/O: 1222084 TASKCARD: NR-00025 ) REF AEROMAN WO 2023 204/1 NR 2023-331339, JB W/O 1222084,SDR YENA2023071800815Unknown · unknownDURING HEAVY MAINTENANCE: CORROSION INTERNAL STRUCTURE WEB LOC. BTW FR 69 AND FR 70 AT LEVEL STR 23L AT AFT GALLEY AREA (CPCP-RELATED MPD TASK 534195-01); REMOVED AND REPLACED STRUCTURE WEB LOC. BTW FR69 AND FR70 AT LEVEL OF STR 23L AT AFT GALLEY AREA IAW A320SDR YENA2023071800800Unknown · unknownDURING HEAVY MAINTENANCE: CORROSION LOWER SIL LOC. BTW FR66-FR68 STR23L AT AFT GALLEY AREA (CPCP MPD 534195-01); REMOVED & REPLACED LOWER SIL LOC. BTW FR66- FR68 AT STR 23L AT AFT GALLEY AREA IAW A320 SRM 5-42-11 & SRM 51-72-11 & DWG D53480505 REF AEM WO 2023-SDR YENA2023071800799Unknown · unknownDURING HEAVY MAINTENANCE: CORROSION INTERNAL STRUCTURE WEB LOCATED BTW FR 69 AND FR70 AT LEVEL STR 23R AT AFT GALLEY AREA (CPCP RELATED MPD TASK 534195-01.); REF AEROMAN WO 2023 204/1 NR 2023-331339, JB W/O 1222084, NR-00025. REMOVED AND REPLACED STRUCTURE WEBSDR DALA2023071705785Unknown · unknownSHIP 3118 CORROSION FLOOR BEAM -Y765 LOC BTW FR64 TO FR66 IN PASSENGER CABIN. CORRECTIVE ACTION: APPLIED PROTECTIVE TREATMENT ON HOLES OF NEW FLOOR BEAM-Y765 AS PER A319 SRM 51-21-11 AND A319 SRM 51-23-11. (2866300)SDR DALA2023071705791Unknown · unknownSHIP 687 CORROSION ON RH SIDE PLATE (BOTH FACES LWR/ UPPER) BTW STA= 1380/1440 AT AFT CARGO COMPARTMENT (C2). CORRECTIVE ACTION: SUMMARY OF NRC 00117: RH SIDE PLATE (BOTH FACES LWR/UPPER) BTW STA= 1380/1440 AT AFT CARGO COMPARTMENT WAS FABRICATED PER DWG:146N5SDR DALA2023071705790Unknown · unknownSHIP 687 CORROSION ON INTERCOSTAL BTW STA= 1300/1320 AND BTW STR= 27L/28L, AT AFT CARGO COMPARTMENT (C2).IN REF NRC 00121. CORRECTIVE ACTION: SUMMARY OF NRC 00769: INTERCOSTAL BTW STA= 1300/1320 AND BTW STR= 27L/28L, AT AFT CARGO COMPARTMENT WAS FABRICATED ANDSDR DALA2023071705748Unknown · unknown(LOG 2865651) MAIN CABIN FLOOR SUPPORT STRAP HAS CORROSION ON UPPER SURFACE AT NUTPLATE HOLES BS 947 TO BS 967 LBL 25. REMOVED AND REPLACED MAIN CABIN FLOOR STRUCTURE FLOOR SUPPORT STRAP BETWEEN STA 947 AND STA 967, LBL 25 IAW B737 SRM 51-40-02.SDR DALA2023071705747Unknown · unknown(LOG 2865609) MAIN CABIN FLOOR SUPPORT STRAP HAS CORROSION ON UPPER SURFACE AT NUTPLATE HOLES BS 947 TO BS 967 LBL 50. REMOVED AND REPLACED MAIN CABIN FLOOR SUPPORT STRAP P/N 147A5660Y21 BETWEEN STA 947 AND STA 967, LBL 50 IAW B737 SRM 51-40-02.SDR KCSA202307141078Angle · crackedVERTICAL ANGLE CRACKED ON FWD SIDE AT STA 2658 APU FIREWALL LBL 26 WL 260SDR KCSA202307141076Web · corrodedEVIDENCE OF CORROSION ON WEB @ STA 1840 RBL 51SDR 3J7R2023071400001Channel · crackedDURING INSPECTION FOUND THE CARGO DOOR FWD HINGE AND U CHANNEL CRACKED.
Back to JASC 5320