SDR SWAA2023041716208Support Angle · crackedCRACK ON SUPPORT ANGLE CEILING AREA LOCATED BS 867 BTW STR 2R TO STR 3R AT PASSENGER CABIN 2023-185374<[01] REPLACED SUPPORT ANGLE CEILING AREA LOCATED BS 867 BTW STR 2R TO STR 3R AT PASSENGER CABIN IAW B737-700 SRM 51-10-02 ITEM 9 AND DRAWING# 146A7601 REV: ASDR SWAA2023041215683Floor Panel · peelingFLOOR PNL 241DF HAS FIBERS PEELING ON UPPER SIRFACE. 8-82<[01] RECEIVED NEW PANEL 241DF (PO#2012626). PANEL WILL BE INSTALLED ON TTG8Q00H698M.;[02] VERIFIED STEP#1SDR AALA202304030305Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN FLOOR SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23L. REPLACED SHEAR PLATE PER SRM 51-42-11.SDR AALA202304037259Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN FLOOR SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23R. REPLACED SHEAR PLATE PER SRM 51-42-11.SDR SWAA2023041715782Fitting · crackedDURING BUYBACK FOUND SUPPORT FITTING HAS 0.390' CRACK AT STR 16L BETWEEN STA 294.5 THRU 303.9 WL 208.1<[01] STARTED TO REMOVE FASTENERS AT SUPPORT FITTING LOCATED AT STR 16L BETWEEN STA 294.5 AND 303.9 WL 208.1 PER B737-700 SRM 51-40-02-0G-0;[02] REMOVED SUPPOSDR SWAA2023041715732Intercostal · corrodedCORROSION ON FLOOR STRUCTURE INTERCOSTAL BRAKE PANEL LOCATED BTW BS 312 TO BS 328 WL 208.1 RBL 10 AT FWD GALLEY AREA 2023-185317<[01] REPLACED FLOOR STRUCTURE INTERCOSTAL BRAKE PANEL LOCATED BTW BS 312 TO BS 328 WL 208.1 RBL 10 AT FWD GALLEY AREA IAW B737-700 SDR AALA202304140230Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN FLOOR SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23R. REPLACED SHEAR PLATE PER SRM 51-72-11.SDR AALA202304133442Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN FLOOR SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23L. REPLACED SHEAR PLATE PER SRM 51-42-11.SDR SWAA2023041115179Intercostal · crackedCABIN FLOOR STRUCTURE INTERCOSTAL CRACKED BETWEEN STA 380-400 AND LBL 13<[01] C/W;[02] C/W;[03] VERIFIED REPLACEMENT OF CABIN FLOOR INTERCOSTAL BETWEEN STA. 380-400 AND LBL 13SDR SWAA2023041115178Intercostal · crackedCABIN FLOOR STRUCTURE INTERCOSTAL CRACKED BETWEEN STA 380-400 AND RBL 39<[01] REMOVED AND REPLACED NEW INTERCOSTAL AT MAIN CABIN STA 380-400 RBL 39' AS PER SRM 51-40-02 AND DWG 143A5400;[02] VERIFIED STEP 1;[03] TASK C/W;[04] VERIFIED STEP 1SDR SWAA2023041115182Intercostal · crackedCABIN FLOOR STRUCTURE INTERCOSTAL CRACKED BETWEEN STA 380-400 AND RBL 9<[01] INSTALLED NEW INTERCOSTAL BETWEEN STA 380-400 AT RBL 9 REF 51-40-02-0G-0 AND DWG 145A5400;[02] C/W;[03] TASK C/WSDR SWAA2023041115180Intercostal · crackedCABIN FLOOR STRUCTURE INTERCOSTAL CRACKED BETWEEN STA 277-291.5 AND BL0<[01] REMOVED AND REPLACED INTERCOSTAL AT MAIN CABIN BETWEEN STA 277 AND STA 291.5 BL 0 REF SRM 51-40-02-0G-0 AND DWG #141A5400.;[02] VERIFIED STEP 1SDR ASAA2023031242745Floor Panel · delaminatedFWD WET AREA FLOOR PANEL 141A5810-175 HAS DELAMINATION, CORRODED INSERTS & CORNER DAMAGE. GROUNDED - YES. REPAIRED FWD WET AREA FLOOR PANEL 141A5810-175 IAW ASA B737-800 SRM 53-00-50, SRM 53-00-50-2R-0.SDR ASAA2023031242709Floor Panel · delaminatedAFT WET AREA FLOOR PANEL 147A5810-30 UPPER SURFACE PEELING. GROUNDED - YES. REPAIRED AFT WET AREA FLOOR PANEL 147A5810-30 IAW ASA B737-800 SRM 53-00-50, SRM 53-00-50-2R-0.SDR ASAA2023031242598Transition Panel · corrodedFWD CARGO , R/H TRANSITION FLOOR SUPPORT HAS NUMEROUS PLACES THAT HAVE CORROSION (CIRCLED IN RED). GROUNDED - YES. EVALUATED CORROSION ON R/H TRANSITION PANEL ORIG 0.040: REMOVED 0.009;REMAINING 0.031;FOUND TO BE OUT OF LIMITS PER B737-800 SRM 53-00-53-1A-2.4.SDR ASAA2023031242539Transition Panel · corrodedAFT CARGO R/H TRANSITION FLOOR SUPPORT HAS NUMEMEROUS PLACES WITH CORROSION (MARKED IN RED). GROUNDED - YES. REMOVED CORROSION FROM AFT CARGO R/H TRANSITION PANEL; ORIGINAL THICKNESS: .040, REMOVED: .007, REMAINING: 0.33 & FOUND TO BE OUT OF LIMITS PER B737-80SDR ASAA2023031242538Transition Panel · corrodedAFT CARGO L/H TRANSITION FLOOR SUPPORT HAS NUMEROUS PLACES WITH CORROSION (MARKED IN RED). GROUNDED - YES. REMOVED CORR. FROM AFT CARGO L/H TRANSISTION PNL; ORIG MAT 0.040; 100% MAT LOSS; FOUND TO BE OUT OF LIMITS PER B737-800 SRM 53-00-53-1A-2-4-2-D; REPAIREDSDR ASAA2023031242522Baffle · crackedFWD CARGO COMPARTMENT BAFFLE CLIP STA 500H AFT SIDE UNDER L/H TRANSITION PANEL CRACKED. GROUNDED - YES. REMOVED AND REPLACED BAFFLE CLIP STA 500H AFT SIDE AT L/H TRANSITION PANEL IAW B737-800 SRM 51-40-02-0G-0.SDR ASAA2023031242359Floor Panel · delaminatedAFT WET AREA FLOOR PANEL147A5810-28 HAS CORRODED INSERTS. GROUNDED - YES. CLEANED, SANDED AND REMOVED DAMAGE AND DAMAGE INSERTS ON AFT WET AREA FLOOR PANEL 147A5810-28 AND REPAIRED IAW B37-800 SRM 55-00-50-2R.SDR VNAA202304270021Channel · corrodedIN TAILCONE AND THE DRAG ANGLE ADJACENT TO BELOW RUDDER WAS FOUND CORROSIONSDR SWAA2023041715771Bracket · crackedFWD CARGO STA 500C LBL 23.5 S-26L WL 156 INTERCOSTAL SUPPORT BRACKET ON AFT SIDE OF FRAME IS CRACKED 124-006<[01] REMOVED AND REPLACED INTERCOSTAL SUPPORT BRACKET AT FWD CARGO STA 500C LBL 23.5 S-26L WL 156 PER B737-700 SRM 51-40-02-0G-0 & DRAWING NO. 143A7505SDR SWAA2023041715779Angle · crackedINTERCOSTAL UPPER CHORD (ANGLE) AT BETWEEN STA 380 AND STA 400 BL 0; HAS CRACKS AT FASTENERS HOLES;<[01] REMOVED AND REPLACED INTERCOSTAL UPPER CHORD (ANGLE) BETWEEN STA 380 AND STA 400 BL 0 PER B737-700 SRM 51-40-02-0G-0 AND DRWG #143A5400.;[02] VERIFIED STEPSDR SWAA2023041715658Intercostal · corrodedCORROSION ON FLOOR STRUCTURE INTERCOSTAL BRAKE PANEL LOCATED BTW BS 294.5 TO BS 312 AT FWD GALLEY AREA 2023-185239<[01] TOOL USED: ULTRASONIC THICKNESS GAUGE; PN: 45MG; SN: 221861811; DUE DATE: 08-NOV-23;[02] REPLACED NEW INTERCOSTAL BRAKE PANEL LOCATED BTW BSSDR SWAA2023041215203Panel · brokenPANEL 242DF CORNER BROKEN. 8-79<[01] RECEIVED NEW PANEL 242DF INSTALLATION WILL BE ACCOMPLISHED ON TTG8Q00H6971;[02] FINAL INSPECTION; RECEIVED NEW PANEL 242DF INSTALLATION WILL BE ACCOMPLISHED ON TTG8Q00H6971.SDR ASAA2023031142626Web · corrodedFORWARD CARGO DOOR CUTOUT THRESHOLD SILL PLATE HAS SURFACE CORROSION AT SEEM AND AROUND FASTENERS HOLES. GROUNDED - YES. REMOVED CORROSION FROM WEB:ORIG MAT.0.056; REMOVED 0.012; RENAUBUBG 0.044 AND FOUND TO BE OUT OF LIMITS PER B737-800 SRM 53-30-15REMVOED ANSDR ASAA2023031142625Threshold Web · corrodedAFT CARGO DOOR CUTOUT- THRESHOLD SILL PLATE HAS SURFACE CORROSION LENGTH WISE ALONG SEEM AND FASTENER HOLES/. GROUNDED - YES. REMOVED CORROSION FROM AFT CARGO LOWER SILL WEB,ORIG THICKNESS 0.050;REMOVED 0.006;REMAINING 0.044 AND FOUND TO BE OUT OF LIMITS PER BSDR AALA202303222753Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT LEFT PASSENGER / CREW DOOR CUT OUT FORWARD LOWER CORNER SHAPE FITTING AT FR 66 AND S23L. REPLACED CORNER SHAPE FITTING PER SRM 51-42-11.SDR AALA202303224695Fitting · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LEFT AFT PASSENGER / CREW DOOR CUT OUT LOWER AFT CORNER SHAPE FITTING AT FR 68 AND S23L. REPLACED AFT CORNER SHAPER FITTING PER SRM 51-42-11.SDR AALA202306125846Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN FLOOR SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23R. REPLACED SHEAR PLATE PER SRM 51-42-11.SDR SWAA2023041814979Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS344+6 RBL51 WL208.<[01] REQUEST NDI TO VERIFY DAMAGE.;[02] REMOVED INTERCOSTAL AT FWD CABIN BS 344-360 RBL 51 WL 208 IAW SRM 51-40-02;[03] AFTER INTERCOSTAL REMOVED CRACKS ARE NOTED ON FASTENER HOLES AND NO DATA FOUND ON SRM SDR SWAA2023041815003Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS344+6 RBL32 WL208.<[01] REQUEST NDI TO VERIFY DAMAGE.;[02] REMOVED INTERCOSTAL AT BS 344 TO 360 RBL32 PER SRM 51-40-02-0G-0;[03] AFTER INTERCOSTAL REMOVED CRACKS ARE NOTED ON FASTENER HOLES AND NO DATA FOUND ON SRM 53-10-51-1SDR SWAA2023041815001Intercostal · crackedCRACKED INTERCOSTAL AT FWD CABIN BS344+6 LBL11 WL208.<[01] REQUEST NDI TO VERIFY DAMAGE.[11] 7075-T6 CLAD SHEET#0.080 LOT#1492623-1.<BR>IAW SRM 53-10-51-2R-10 PART 4.H TO 4.L FIG.205; REFER TO EA 23-153-01114-WIP1 STEPS 10-13; SRM 51-40-05-0G-0.;[12] UPDATE STSDR SWAA2023041815606Support · corrodedMULTIPLE AREA OF CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21 BS 727C+10 TO BS 767 (MARKED)<[01] VERIFIED APPLICABILITY SRM 53-60-53-01-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE.<BR><BR>STEPS 1-3 COMPLETED.;[02] VERIFIEDSDR SWAA2023041815607Support · corrodedMULTIPLE AREA OF CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 727 TO BS 727D+10 (MARKED)<[01] VERIFIED APPLICABILITY SRM 53-60-53-01-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE.<BR><BR>STEPS 1-3 COMPLETED.;[02] VERIFIEDSDR SWAA2023041815608Support · corrodedMULTIPLE AREA OF CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 21 BS 727D+10 TO BS 847 (MARKED)<[01] VERIFIED APPLICABILITY SRM 53-60-53-01-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE.<BR><BR>STEPS 1-3 COMPLETED.;[02] VERIFIEDSDR SWAA2023041814989Support · corrodedCORROSION ON FLOOR SUPPORT AT FWD CABIN BS270+6 LBL11 WL208.<[01] EVALUATED DAMAGE ON FLOOR SUPPORT AT FWD CABIN BS270+6 LBL11 WL208; FOUND TO BE OUT OF LIMITS; DUE NOT LIMITS IN SRM PART WILL BE REPAIRABLE BY REPLACEMENT; IAW SRM 51-10-02-0G-0;[02] REMOVED FLSDR SWAA2023041814665Strap · corrodedCORROSION ON PAX CABIN FLOOR TENSION STRAP AT STA 1016 TO 1016+2; RBL 3; WL 208.1<[01] NO ALLOWABLE DAMAGE LIMITS FOUND IN SRM FOR THIS ITEM. THE STRUCTURAL ITEMS THAT DO NOT HAVE ENTRIES ARE CALLED REPAIRABLE BY REPLACEMENT PER SRM 51-10-02 PARAGRAPH 9;[02] RSDR SWAA2023041815591Support · corrodedAFT CARGO - AFT BULKHEAD LOWER FLOOR SUPPORT HAS CORROSION BS 947 LBL 3; LBL 4.5; LBL 8; LBL12.5; RBL 2; RBL 5.5; RBL 7.75; RBL 8.5; RBL 10; RBL 11.75; RBL 14; RBL 15.25.<[01] REMOVED AFT CARGO BAY AFT LOWER BULKHEAD SUPPORT AT BS 947 BRACKET P/N (149A8118-29)SDR SWAA2023041815594Rail · corrodedAFT CARGO BAY - RAIL HAS CORROSION LBL 3 BS 727+9.5; BS 727+12.75; BS 767+5.<[01] VERIFIED APLICABILITY SRM 53-60-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE;[02] COMPLETED STEPS 1-3.<BR><BR>OK TO APPLY CHEMICAL CONVERSION COATING ANDSDR SWAA2023041815595Support · corrodedMULTIPLE AREA OF CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 500B+10-500D WL 158.<[01] FLOOR TO SIDEWALL SUPPORT SHOW PREVIOUS REINFORCING REPAIR & NOT HAS ALLOWABLE DAMAGE IN SRM AT LBL 24 BS 500B+10' TO BS 500D WL 156.5 MUST BE REPAIR BSDR SWAA2023041815576Support · corrodedMULTIPLE AREA OF CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 500-500B WL 158.<[01] FLOOR TO SIDEWALL SUPPORT SHOW PREVIOUS REINFORCING REPAIR & NOT HAS ALLOWABLE DAMAGE IN SRM AT LBL 24 BS 500 TO BS 500B WL 156.5 MUST BE REPAIR BY REPLACESDR SWAA2023041815578Support · corrodedMULTIPLE AREA OF CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 420-480 WL 157.<[01] PARTIAL STEPS # 1-3.;[02] PARTIAL UPDATES STEPS 1 - 3;[03] RECEIVED EXTRUSION P/N BAC1496-444 LOT. 1520195-1. LOCATED AND DRILLED (2EA) EXTRUSION (FORMED CHSDR SWAA2023041815599Support · corrodedMULTIPLE AREA OF CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 400-420 WL 157.<[01] VERIFIED APPLICABILITY FOR SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2.;[02] REMOVED CORROSION ON FCB TO SIDEWALL SUPPORT AT RBL24;BS400-420;WL157.MEASURE:L=.9';W=SDR SWAA2023041815600Shield · corrodedMULTIPLE AREA OF CORROSION ON FWD CARGO BAY FWD DOOR SHIELD AT RBL 24 BS 420-440 WL 157.<[01] VERIFIED SRM 51-10-02 PARAG 9. IS APPLICABLE FOR REPAIRABLE BY REPLACEMENT.;[02] CORROSION ON FWD CARGO BAY FWD DOOR SHIELD LOCATED BETWEEN BS 420-BS 440 RBL24.FOUND SDR SWAA2023041815601Shield · corrodedMULTIPLE AREA OF CORROSION ON FWD CARGO BAY AFT DOOR SHIELD AT RBL 24 BS 480+13-500A WL 157.<[01] VERIFIED SRM 51-10-02 PARAG 9.IS APPLICABLE FOR REPAIRABLE BY REPLACEMENT.;[02] CORROSION ON FWD CARGO BAY AFT DOOR SHIELD;LOCATED BETWEEN BS 492.4-BS 500A;FOUND SDR SWAA2023041815582Support · corrodedMULTIPLE AREA OF CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 500A-500D WL 157.<[01] VERIFIED APPLICABILITY FOR SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2.;[02] REMOVED CORROSION ON FCB TO SIDEWALL SUPPORT AT RBL24;BS500A-500D;WL157.MEASURE:L=.5SDR SWAA2023041815602Shield · corrodedAFT CARGO BAY - AFT SHIELD HAS CORROSION BS 847+4.75; RBL 18 / BS 847+5.5 RBL 15 /BS 847+16.25 RBL 16<[01] THIS PART HAS NO ALLOWABLE DAMAGE PER SRM#51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION ITEM 1.;[03] RECEIVED NEW SHIELD P/N 146A8127-10 LOT # 1497361-1 SDR SWAA2023041815585Support · corrodedMULTIPLE AREA OF CORROSION ON FWD CARGO BAY SIDEWALL SUPPORT AT BS 480+19 STRINGER 22L-25L.<[01] VERIFIED SRM 51-10-02 PARAG 9;IS APPLICABLE BY REPLACEMENT.;[02] PRIOR TO REMOVAL;FOUND PART HAS NOT SRM LIMITS AND SO PART IS REPAIRABLE BY REPLACEMENT;IAW SRM 51SDR SWAA2023041815603Shield · corrodedAFT CARGO BAY - FWD SHIELD HAS CORROSION RBL 20.75 BS 767+3.25; BS 767+7.25; BS 767+11.25; BS 767+15 / RBL 22.75 BS 767+1.5; BS 767+4.5; BS 767+5.75; BS 767+15.25.<[01] THIS PART HAS NO ALLOWABLE DAMAGE LIMITS PER SRM#51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTSDR SWAA2023041815588Support · corrodedAFT CARGO BAY - CORROSION ON SIDEWALL SUPPORT AT RBL 21.75 BS 727B+2; BS 727B+6; BS 727B+10; BS 727B+14; BS 727C+2; BS 727C+6 / RBL 20.5; BS 727B+11.5; BS727B+15; BS 727C+1.5; BS 727C+5.<[01] VERIFIED APPLICABILITY SRM 53-60-53-01-2 FOR IDENTIFICATION AND SRM
Back to JASC 5320