JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022090244199None · corrodedFOUND CORROSION ON ANGLE UNDER R/H TRANSITION ANGLE STA 767 -STA 787. / [01] REMOVED DAMAGED PART PER SRM 51-40-02.;[02] REMOVED DAMAGED FROM ANGLE AND FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.;[03] DRILLED; DEBURRED NEW PARTS PER SRM 51-40-05;[04] OK TSDR REXA2022082501923Seat Track · corrodedSEAT TRACK CORRODED - RBL9, FS559+85-559+96 REPLACED CORRODED SEAT TRACKSDR REXA2022082401949Frame · corrodedFRAME AT FS 927 CORRODED BETWEEN STRGR 24L AND 24R REMOVED AND REPLACED NEW FRAME P/N: SH690-37083-3 AT FS 927 BETWEEN STR 20L TO STR 23R IAW CRJ 900 SRM 53-00-06-201-001-A03SDR REXA2022082401947Seat Track · corrodedSEAT TRACK CORRODED - RBL27,FS 559.00+80-559.00+96 REPLACED CORRODED SEAT TRACKSDR REXA2022082401946Seat Track · corrodedSEAT TRACK CORRODED - LBL27, FS559.00+80-559.00+96 REPLACED CORRODED SEAT TRACKSDR REXA2022082301940Channel · crackedAFT CARGO DOOR AFT TRACK LOWER FWD "U" CHANNEL IS CRACKED. REPLACED“U” CHANNEL P/N MM670-35552-005 IAW CRJ900 SRM 51-42-06-001-001-A01 AND CRJ900 SRM 51-42-21-001-001-A01.SDR REXA2022082301938Post · corrodedBOTTOM CORNER OF BULKHEAD POST IS CORRODED AT LBL9 FS 280.00 CROSS BEAM. REPAIRED IAW CRJ-900 SRM 53-11-10-201-004-A01.SDR REXA2022082301937Angle · corrodedBOTTOM CORNER ANGLE OF BULKHEAD POST IS CORRODED AT LBL9 FS 280.00 CROSS BEAM. REMOVED AND REPLACED ANGLE IAW CRJ 900 SRMS 51-40-11-001-001-A01, AND 51-42-06-001-001-A01.SDR REXA2022082301933Post · corrodedBOTTOM CORNER OF BULKHEAD POST IS CORRODED AT LBL9 FS 280.00 CROSS BEAM. REPAIRED IAW CRJ-900 SRM 53-11-10-201-004-A01.SDR REXA2022082301928Stringer · corrodedSTGR22L IS CORRODED BETWEEN FS349 AND FS364. REPAIRED STRINGER 22L IAW CRJ900 SRM 53-00-03-201-001-A02.SDR REXA2022082301927Intercostal · corrodedSTGR 20R INTERCOSTAL IS CORRODED FROM FS310 TO FS364. REMOVED AND REPLACED INTERCOSTAL IAW CRJ 900 SRMS 51-40-11-001-001-A01, 51-42-06-001-001-A01, AND 51-42-21-001-001-A01.SDR REXA2022082301926Intercostal · corrodedSTGR 20R INTERCOSTAL IS CORRODED FROM FS310 TO FS364. REMOVED AND REPLACED INTERCOSTAL IAW CRJ 900 SRMS 51-40-11-001-001-A01, 51-42-06-001-001-A01, AND 51-42-21-001-001-A01.SDR REXA2022082301925Cleat · corrodedSTGR 20R INTERCOSTAL CLEAT IS CORRODED FROM FS310 TO FS364. REMOVED AND REPLACED CLEAT IAW CRJ 900 SRMS 51-40-11-001-001-A01, 51-42-06-001-001-A01, AND 51-42-21-001-001-A01.SDR REXA2022082301924Angle · corrodedSTGR 20R INTERCOSTAL ANGLE IS CORRODED FROM FS310 TO FS364. REMOVED AND REPLACED ANGLE IAW CRJ 900 SRMS 51-40-11-001-001-A01, 51-42-06-001-001-A01, AND 51-42-21-001-001-A01.SDR 2024FA0000162Stiffener · crackedAFT FUSELAGE LOWER SKIN STIFFENER FOUND CRACKED. REPLACED WITH NEW STIFFENER.SDR F3LA2022100300120Floor Support · corrodedAT MAIN CABIN AT FR66 LH SIDE ABOUT 13INCHES FROM DOOR CUT OUT, FLOOR SUPPORTS STRUCTURE HAS CORROSION. CORROSION FOUND OUT OF LIMITS IAW SRM 53-11-14-283-004. REMOVED AND REPLACED AFT CABIN FLOOR SUPPORT FR66 LH SIDE IAW SRM 51-42-11 AND SRM 51-44-11SDR F3LA2022100300117Floor Support · corrodedAFT MAIN CABIN AT FR69 RBL31 FLOOR SUPPORT STRUCTURE HAS CORROSION. REMOVED AND REPLACED FLOOR SUPPORT STRUCTURE AT MAIN CABIN FR 68 TO FR70 RBL31. IAW DWG D53472201 REV B AND SRM 51-42-00 AND SRM 51-72-11-911-001SDR SWAA2022092765187Intercostal · crackedCRACKED INTERCOSTAL AT STA 344+10; WL 208; LBL 1. / [01] REQUEST NDI TO VERIFY CRACK;[02] HFEC INSPECTED AREA IAW 737 NDTM PART 6 51-00-00 PROCEDURE 23.<BR>CRACK NOTED AT AFT FASTENER HOLE. ENDS OF CRACK MARKED.<BR><BR>HFEC INSPECTED OPEN HOLES IAW 737 NDTM PASDR SWAA2022092765186Angle · corrodedCORROSION ON FWD ENTRY DOOR THRESHOLD SUPPORT ANGLE FROM STA 303.9+13 TO STA 328+12; WL 209; LBL 60 TO LBL 65. / [01] REMOVED CORROSION IAW SRM 53-10-15-1A-1. 2'X.65X.015 BS 341.5-343.5. FOUND TO BE OUT OF LIMITS IAW SRM 53-10-15-1A-1.;[02] TOOL ID: ATS401<BR>SDR SWAA2022092765188None · corrodedCORROSION ON FWD ENTRY DOOR MOP SILL FROM STA 294.5+7 TO STA 348.2+6; WL 208 TO WL 209; LBL 54 TO LBL 62. / [01] VERIFIED APPLICABILITY FOR SRM<BR>REMOVED CORROSION FROM FWD ENTRY DOOR MOP SILL AT STA 335 LBL 59 WL 208 WITH ORIGINAL THICKNESS 0.090' AND WITH MSDR SWAA2022092765182Intercostal · crackedCRACKED INTERCOSTAL AT STA 277+7; WL 208; RBL 1. / [01] REMOVED INTERCOSTAL AT STA 277+7' WL 208 RBL 1 IAW SRM 51-40-02.;[02] INTERCOSTAL IT IS OUT OF LIMITS DUE TO NO LIMITS GIVEN IN THE SRM BY REPAIRED BY REPLACEMENT OF PART IAW SRM 51-10-02 PAR 9.;[03] LOCASDR SWAA2022092765185Intercostal · crackedCRACKED INTERCOSTAL AT STA 328+8; WL 208; LBL 45. / [01] LOCATED AND DRILLED NEW INTERCOSTAL BS 328 TO 344 WL 208 LBL 45 IAW SRM 51-40-05-0G-0; AND OK TO INTALL;[02] REMOVED INTERCOSTAL BS 328 TO 344 WL 208 LBL 45 IAW SRM 51-40-02-0G-0;[03] UPDATED MEASUREMENTSDR SWAA2022092765184Intercostal · corrodedCORROSION ON INTERCOSTAL AT STA 312+8; LBL 45; WL 208. / [01] VERIFIED APPLICABILITY FOR SRM 53-10-51-1A-1<BR>REMOVED CORROSION FROM THE INTERCOSTAL OF THE FLOOR STRUCTURE AT STA 312+8 LBL 45 WL 208; WITH ORIGINAL THICKNESS 0.040' AND MEASUREMENTS OF THE REWORSDR SWAA2022092765183Intercostal · corrodedCORROSION ON INTERCOSTAL FROM STA 312 TO 328; WL 208; LBL 12. / [01] REMOVED PANEL BREAK AT STA 312 TO 328 WL 208 LBL 12 IAW SRM 51-40-02<BR><BR>REMOVED CORROSION ON PANEL BREAK BS 314 IN L=2' X W=2' X D=0.40' FROM ORIGINAL TICKNESS OF 0.80' FOUND TO BE OUT OFSDR SWAA2022092765180Intercostal · corrodedCORROSION ON INTERCOSTAL AT STA 294 TO STA 312; WL 208; LBL 10 TO LBL 12. / [01] VERIFIED APPLICABILITY FOR SRM 53-10-51-1A-1<BR>NO DAMAGE IS PERMITTED AT FLOOR BEAM UPPER CHORD UNDER INTERCOSTAL FOR GALLEY HARD MOUNT/ATTACHMENT IAW SRM 53-10-51-1A-1 PARAGRAPHSDR SWAA2022092765178None · corrodedCORROSION ON FWD SERVICE DOOR MOP SILL FROM STA 291.5 TO STA 344; WL 208.1 RBL 52 TO 59. / [01] REMOVED CORROSION IAW SRM 53-10-15-1A-2. 2'X1'X.020. FOUND TO BE OUT LIMITS IAW IAW SRM 53-10-15-1A-2.;[02] TOOL ID: ATS2739<BR>S/N: A22004232<BR>DUE DATE: 04/2023;SDR SWAA2022092765179Intercostal · crackedCRACKED INTERCOSTAL AT STA 312+5 & STA 312+11; WL 208; RBL 31. / [01] NO ALLOWABLE LIMITS FOUND ON SRM REPLACEMENT OF THE PART IS APPLICABLE I.A.W SRM 51-10-02-0G-0 PAR.9.C;[02] REMOVED INTERCOSTAL LOCATED BS312-BS328 RBL31 WL208 I.A.W SRM 51-40-02-0G-0;[03] LSDR SWAA2022092765190Seat Track · corrodedCORROSION ON PASSENGER CABIN SEAT TRACK RBL45 BS562; BS683 - BS691. MARKED. / [01] REMOVED CORROSION IN THE BOTTOM OF SEAT TRACK RBL 45 BS 561 TO BS 563 IN L'=2 X W=1' X D= 0.011' IAW SRM 51-10-02-0G-0 AND EVALUATED BLEN AREA AND FOUND TO BE IN LIMITS IAW SRM SDR SWAA2022092243356Intercostal · crackedCRACKED INTERCOSTAL AT STA 277+7; WL 208; RBL 1. / [01] REMOVED INTERCOSTAL AT STA 277+7' WL 208 RBL 1 IAW SRM 51-40-02.;[02] INTERCOSTAL IT IS OUT OF LIMITS DUE TO NO LIMITS GIVEN IN THE SRM BY REPAIRED BY REPLACEMENT OF PART IAW SRM 51-10-02 PAR 9.;[03] LOCASDR SWAA2022092243361Intercostal · crackedCRACKED INTERCOSTAL AT STA 344+10; WL 208; LBL 1. / [01] REQUEST NDI TO VERIFY CRACK;[02] HFEC INSPECTED AREA IAW 737 NDTM PART 6 51-00-00 PROCEDURE 23.<BR>CRACK NOTED AT AFT FASTENER HOLE. ENDS OF CRACK MARKED.<BR><BR>HFEC INSPECTED OPEN HOLES IAW 737 NDTM PASDR SWAA2022092243746Seat Track · corrodedCORROSION ON PASSENGER CABIN SEAT TRACK RBL45 BS562; BS683 - BS691. MARKED. / BLEND AREA AT BS 682-687; RBL 45 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-52-1A-1;[06] REMOVED PASSENGER CABIN SEAT TRACK RBL45 BS562 BS683- BS691 IAW SOPM 20-50-01.;[07] COMPLETED COSDR SWAA2022092243360None · corrodedCORROSION ON FWD ENTRY DOOR THRESHOLD SUPPORT ANGLE FROM STA 303.9+13 TO STA 328+12; WL 209; LBL 60 TO LBL 65. / [01] REMOVED CORROSION IAW SRM 53-10-15-1A-1. 2'X.65X.015 BS 341.5-343.5. FOUND TO BE OUT OF LIMITS IAW SRM 53-10-15-1A-1.;[02] TOOL ID: ATS401<BR>SDR SWAA2022092243362None · corrodedCORROSION ON FWD ENTRY DOOR MOP SILL FROM STA 294.5+7 TO STA 348.2+6; WL 208 TO WL 209; LBL 54 TO LBL 62. / REMOVED CORROSION FROM FWD ENTRY DOOR MOP SILL AT STA 335 LBL 59 WL 208 WITH ORIGINAL THICKNESS 0.090' AND WITH MEASUREMENTS OF THE REWORKED AREA OF L= SDR SWAA2022092243353Intercostal · crackedCRACKED INTERCOSTAL AT STA 312+5 & STA 312+11; WL 208; RBL 31. / [01] NO ALLOWABLE LIMITS FOUND ON SRM REPLACEMENT OF THE PART IS APPLICABLE I.A.W SRM 51-10-02-0G-0 PAR.9.C;[02] REMOVED INTERCOSTAL LOCATED BS312-BS328 RBL31 WL208 I.A.W SRM 51-40-02-0G-0;[03] LSDR SWAA2022092243354Intercostal · corrodedCORROSION ON INTERCOSTAL AT STA 294 TO STA 312; WL 208; LBL 10 TO LBL 12. / [01] VERIFIED APPLICABILITY FOR SRM 53-10-51-1A-1<BR>NO DAMAGE IS PERMITTED AT FLOOR BEAM UPPER CHORD UNDER INTERCOSTAL FOR GALLEY HARD MOUNT/ATTACHMENT IAW SRM 53-10-51-1A-1 PARAGRAPHSDR SWAA2022092243357Intercostal · corrodedCORROSION ON INTERCOSTAL FROM STA 312 TO 328; WL 208; LBL 12. / [01] REMOVED PANEL BREAK AT STA 312 TO 328 WL 208 LBL 12 IAW SRM 51-40-02<BR><BR>REMOVED CORROSION ON PANEL BREAK BS 314 IN L=2' X W=2' X D=0.40' FROM ORIGINAL TICKNESS OF 0.80' FOUND TO BE OUT OFSDR SWAA2022092243358Intercostal · corrodedCORROSION ON INTERCOSTAL AT STA 312+8; LBL 45; WL 208. / [01] VERIFIED APPLICABILITY FOR SRM 53-10-51-1A-1<BR>REMOVED CORROSION FROM THE INTERCOSTAL OF THE FLOOR STRUCTURE AT STA 312+8 LBL 45 WL 208; WITH ORIGINAL THICKNESS 0.040' AND MEASUREMENTS OF THE REWORSDR SWAA2022092243359Intercostal · crackedCRACKED INTERCOSTAL AT STA 328+8; WL 208; LBL 45. / [01] LOCATED AND DRILLED NEW INTERCOSTAL BS 328 TO 344 WL 208 LBL 45 IAW SRM 51-40-05-0G-0; AND OK TO INTALL;[02] REMOVED INTERCOSTAL BS 328 TO 344 WL 208 LBL 45 IAW SRM 51-40-02-0G-0;[03] UPDATED MEASUREMENTSDR SWAA2022091343889Support Angle · crackedCRACK BODY FAIRING SUPPORT ANGLE LOCATED BS 500D RT SIDE AT LOWER FUSELAGE 2022-456435 / [01] REPLACED SUPPORT ANGLE AND FASTENERS LOCATED BS 500D RT SIDE AT LOWER FUSELAGE I.A.W. B737-700 SRM 51-40-02 AND SRM 51-10-02 ITEM 9 AND DRAWING #116A3010; SHEET 23; RSDR SWAA2022090843551None · out of toleranceFWD CARGO; LH TRANSITION ANGLE FROM PREVIOUS REPAIR SPLICE AT STA. 500E+12 TO STA. 500I REQUIRES REPLACEMENT DUE TO OUT OF LIMITS ON FAULT TTG8Q00E8E60. / [01] REMOVED LH TRANSITION ANGLE FROM PREVIOUS REPAIR SPLICE AT STA. 500E+12 TO STA. 500I; LOCATED; DRILLSDR SWAA2022090843550None · out of toleranceFWD CARGO; LH TRANSITION ANGLE FROM PREVIOUS REPAIR SPLICE AT STA. 500A+10 TO PREVIOUS REPAIR SPLICE STA. 500E+12 REQUIRES REPLACEMENT DUE TO OUT OF LIMITS ON FAULT TTG8Q00E8E60. / [01] REMOVED LH TRANSITION ANGLE FROM PREVIOUS REPAIR SPLICE AT STA. 500A+10 TOSDR SWAA2022090243612None · corrodedR/H TRANSITION ANGLE; STA 847-867 HAS LIGHT CORROSION / [01] BLENDED AND TREATED PER SRM 53-00-53-1A-2;[02] BLENDED CORROSION ON TRANSITION ANGEL PER SRM 53-00-53-1A-2<BR>FOUND TO BE WITHIN THE LIMITS PER SRM 53-00-53-1A-2<BR>TREATED AFTER CLEANING PER SRM 53-SDR SWAA2022090243618None · corrodedR/H TRANSITION ANGLE STA 767-787 HAS CORROSION / [01] REMOVED DAMAGED PART PER SRM 51-40-02.;[02] REMOVED DAMAGE AND FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.;[03] DRILLED; CSK; DEBURRED NEW PARTS PER SRM 51-40-05;[04] OK TO INSTALL NEW PARTS;[05] INSTASDR SWAA2022090243619None · corrodedR/H TRANSITION ANGLE STA 727D-787 HAS CORROSION / [01] REMOVED DAMAGED AREA PER SRM 51-10-02. FOUNDED TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] VERIFIED TO BE OUT OF LIMITS;[03] FABBED; LOCATED; DRILLED; TREATED AND PRIMED PER SRM 53-00-53-2R-5 OK TO INSSDR SWAA2022090243613None · corrodedL/H TRANSITION ANGLE STA 727E-817 HAS CORROSION / [01] REMOVED CORRODED LH TRANSITION ANGLE SECTION FROM STA 727D+9.5 TO 807+10.6 IAW SRM 53-00-53-2R-5.;[02] FABRICATED; LOCATED; DRILLED; ALODINED AND PRIMED ALL REPAIR PARTS IAW SRM 53-00-53-2R-5.;[03] LOCATEDSDR SWAA2022090243617Strap · corrodedCARGO FLOOR BEAM STRAP AT STA 887 HAS CORROSION / [01] REMOVED AND REPLACED CARGO FLOOR STRAP PER SRM 51-40-02.;[02] VERIFIED;[03] CERTIFIED;[04] C/WSDR REXA2022082401954Splice · corrodedGUSSET AT FS 379 AND STRINGER 21R IS CORRODED. REPLACED JOINT PIECE AT STRINGER 21R BETWEEN FS 379 TO 394 IAW CRJ900 SRM 51-42-06-001-001-A01 AND SRM 51-40-11-001-001-A01SDR REXA2022082401953Frame · corrodedFRAME 379 IS CORRODED BETWEEN STRINGERS 20R TO 21R REPLACED FS379 FRAME BETWEEN STRINGERS 20R TO 25R IAW CRJ900 SRM 51-42-06-001-001-A01 AND 51-40-11-001-001-A01SDR REXA2022082401952Splice · corrodedSTGR 21R SPLICED CORRODED AT FS 333 REPLACED STGR 21R FS 333 SPLICE IAW CRJ 900 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01SDR REXA2022082401951Stringer · corrodedSTGR 21R IS CORRODED BETWEEN FS 280 AND FS 333 REPLACED STGR 21R BTW FS 280 AND FS333 IAW CRJ900 SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01
Back to JASC 5320