SDR SWAA2022083142204None · corrodedAFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT HAS AREAS OF CORROSION BS727I TO BS767 RBL21 WL156 / [01] EVALUATED CORROSION AT ALL LOCATIONS ON FLOOR TO SIDEWALL SUPPORT; FOUND DEEPEST LOCATION TO BE AT BS 727J+10 RBL 21 WL 156; FOUND 0.015 REMOVED FROM ORIG 0.0SDR SWAA2022083142215Shield · corrodedAFT CARGO BAY SHIELD FWD OF CARGO DOOR HAS AREAS OF CORROSION BS767 TO BS792 RBL21 WL156 / [01] EVALUATED CORROSION ON SHIELD BS 767 TO 792 RBL 21 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02]SDR SWAA2022083142207Support · corrodedFWD CARGO BAY BS500I LOWER BULKHEAD SUPPORT HAS AREA OF CORROSION RBL10 TO LBL10 WL156 / [01] EVALUATED CORROSION AT ALL LOCATIONS ON BULKHEAD SUPPORT; FOUND DEEPEST LOCATION TO BE AT BS 500I RBL 10 WL 156; FOUND 0.020 REMOVED FROM ORIG 0.071 IN NUMEROUS 1'X1'SDR SWAA2022083142208Plate · crackedFWD CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE HAS AREAS OF CORROSION BS500A TO BS500I RBL23 WL156 / [01] EVALUATED CORROSION AT ALL LOCATIONS ON FLOOR TO SIDEWALL SUPPORT; FOUND DEEPEST LOCATION TO BE AT BS 500D+10 RBL 23 WL 156; FOUND 0.015 REMOVED FROM OSDR SWAA2022082642198Intercostal · elongatedINTERCOSTAL HAS ELONGATED HOLE COMMON TO FLOOR RAIL BS 727A-727B RBL 13 / [01] REMOVED INTERCOSTAL HAS ELONGATED HOLE COMMON TO FLOOR RAIL BTW BS 727A-727B RBL 13 IAW SRM 51-40-02-0G-0.;[02] REMOVED (2EA) CLIPS FOR ACCESS LOCATED BTW BS 727A - 727B IAW SRM 51-SDR SWAA2022082642199None · elongatedFRAME TO RAIL CLIP HAS ELONGATED HOLE BS 767 RBL 13 / [01] LOCATED AND DRILLED NEW CLIP PN# 146A1310U6; PO#879079 IAW SRM 51-40-05 AND IAW DWG#146A1261... OK TO INSTALL;[02] VERIFIED CORRECTIVE ACTION 1.<BR>OK TO INSTALL;[03] INSTALLED NEW CLIP AT BS 767 RBL 1SDR AALA202208239552None · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON MAIN CABIN RIGHT HAND MOP SILL LOCATED FROM BS 292 TO BS 305, RBL 64. REPLACED SILL PER SRM 51-40-02-0G.SDR REXA2022081601875Frame · corrodedFRAME SECTOR F.S.333 IS CORRODED BETWEEN STRINGER 24L- 26R OUT OF LIMITS REQUIRES REPAIR/REPLACEMENT. REPAIRED FRAME SECTOR F.S.333 IAW CRJ 900 SRM PROCEDURESSDR CALA2022081602100Fitting · crackedHOLES #1 AND #3 INTERCOSTAL FITTING 7 FR15-16 LH FOUND WITH CRACK. AS NOTED ON LTPR NR# 5001169092-0010 EVALUATED THE INTERCOSTAL AT LH FR16 #7 DOOR STOP HOLES #1 & #3, REMOVED FITTING AND REAMED HOLES PER DRW R53113118, SRM 51-42-11 & SRM 51-44-11, CRACK STILSDR F3LA2022100300123Door Sill · corrodedDISCREPANCY: AFT RH PAX DOOR CUT OUT LOWER STRUCTURE HAS CORROSION ON SEVERAL PLACES. CORROSION FOUND OUT OF LIMITS IAW SRM 53-00-29-283-001
CORRECTIVE ACTION: REMOVED AND REPLACED DOOR SILL AND SHAPE IAW 51-42-11SDR VNAA2022092499912Intercostal · corrodedCORROSION WAS FOUND ON INTERCOSTAL AT STRINGER 20R, BTW FS 310.00 AND FS 319.70 ON MAIN AVIONICS COMPARTMENTSDR F3LA2022083100092Shear Plate · crackedDISCREPANCY: REFERENCE PEMCO N/R#12704.0309 AFT CABIN AFT WET AREA R/H SHEAR PLATE CRACKED UNDERNEATH FWD END
CORRECTIVE ACTION: REMOVED AND REPLACED AFT CABIN AFT WET AREA R/H SHEER PLATE IAW A320 SRM 51-42-11 PARA 2 E AD PARA 2L.//END//SDR AALA202208245711Baffle · crackedAIRCRAFT IN BASE MAINTENANCE: LEFT BAFFLE CRACKED AT 500C TO 500D AND LEFT BUTT LINE 21. REMOVED AND REPLACED BAFFLE PER SRM 51-40-02.SDR REXA2022081601873Web · corrodedRH FS 280 BULKHEAD LOWER WEB CORRODED. INSTALLED NEW RH LOWER WEB IAW CRJ 900 SRM 53-11-001-004-A01.SDR REXA2022081601872Web · corrodedLH FS 280 BULKHEAD LOWER WEB CORRODED. INSTALLED NEW LH LOWER WEB IAW CRJ 900 SRM 53-11-10-201-004-A01.SDR FDEA202208132122Floor Support · corrodedLWR FWD CARGO COMPT, AFT WALL, STA. 6-73, LBL 51, CORROADED FLOOR SUPPORT. DOT #45 LWR FWD CARGO COMPT, AFT WALL, STA. 6-73, LBL 51, CORRODED FLOOR PANEL SUPPORT LEG, REPAIR PERFORMED IAW EA 1-5310-T0370168 P1. MINOR REPAIR. ORIG SUB DATE: 8/31/2022SDR SWAA2022082441326Scuff Plate · crackedFWD CARGO DOOR FWD LOWER CORNER THRESHOLD AT STA 440 CRACKED. / [01] INSTALLED NEW FWD CORNER SCUFF PLATE AT FWD CARGO DOOR CUTOUT; STA 440 PER AMM 53-11-02.;[02] NO WORK ACCOMPLISHED. SIGNED FOR PART INSTALLED.;[03] INSPECTED INSTALLED NEW FWD CORNER SCUFF PLSDR AALA202208242670Baffle · crackedAIRCRAFT IN BASE MAINTENANCE: FOUND BAFFLE CRACKED ON LEFT SIDE AT STA 500A TO 500B AND LEFT BUTT LINE 21. REMOVED AND REPLACED SERVICEABLE BAFFLE PER SRM 51-40-02.SDR AALA202208248691Baffle · crackedAIRCRAFT IN BASE MAINTENANCE: FOUND BAFFLE CRACKED ON LEFT SIDE LOCATED AT STA 500 TO 500A AND LEFT BUTT LINE 21. REMOVED AND REPLACED BAFFLE PER BOEING DRAWING.SDR AALA202208243487Baffle · crackedAIRCRAFT IN BASE MAINTENANCE: FOUND BAFFLE LOCATED AT LEFT STA 500B TO 500C AND LEFT BUTT LINE 21L. REMOVED AND REPLACED BAFFLE PER BOEING DRAWING.SDR FDEA202208131975Floor Support · corrodedAFT CARGO - FLOOR PANEL SUPPORT AFT UPPER CHORD STATION 1841 X = -26.5 FOUND CORROSION AFT CARGO - FLOOR PANEL SUPPORT AFT UPPER CHORD STATION 1841 X = -26.5 CORROSION REMOVED AS PER SRM 51-21-01-0G AND FOUND EXCEEDED ALLOWABLE LIMITS PER SRM 53-00- 00-2RSDR AALA202208236427None · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON TRANSITION PANEL LOCATED AT BS 480 AND LBL 25. REPAIRED PANEL PER SRM 53-00-53-2R-5.SDR SWAA2022081741434Angle · corrodedFWD CARGO COMPARTMENT AFT BULK HEAD PANEL SUPPORT LOWER L-ANGLE AT STA. 500I HAS CORROSION. / [01] REMOVED DAMAGED ANGLE PER SRM 51-40-02. REMOVED DAMAGE PER SRM 51-10-02 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. MATCH DRILLED NEW ANGLE PER SRM 51-40-05SDR REXA2022081701886Seat Track · corrodedLBL9 SEAT TRACK SEGMENT BETWEEN F.S.693 TO F.S.847 IS CORRODED REMOVED AND INSTALLED NEW FABRICATED SEAT TRACK SEGMENTSDR REXA2022081701885Seat Track · corrodedRBL9 SEAT TRACK SEGMENT BETWEEN F.S.693 TO F.S.847 IS CORRODED REMOVED AND INSTALLED NEW FABRICATED SEAT TRACK SEGMENTSDR REXA2022081701883Intercostal · corrodedINTERCOSTAL BETWEEN FS394 AND FS409 BETWEEN STGR26R AND STGR27 IS CORRODED. REPLACED INTERCOSTAL FROM FS394 AND FS409 BETWEEN STRINGER 26R AND STRINGER 27.SDR CALA2022081602098Structure · crackedEA 5380-01113 REV B OP 017 LH BS 2370 PIVOT BULKHEAD FORWARD CHORD CRACK FOUND AS MARKED. PLEASE GENERATE EA 5380-01113 REV B OP 25. TRANSFER REF NR HX WO.999860 AND ORIGINATED BY EMP V914372. LH BS 2370 PIVOT BULKHEAD FORWARD CHORD REPLACEMENT AS PER EA 5380-SDR F3LA2022101100131Bracket · corrodedDISCREPANCY: REFERENCE NR B000311 MAIN DCK AFT CABIN FLOOR STRUCTURE PLATE/BRACKET, LH, BETWEEN FR69 AND FR70 HAS CORROSION . CORRECTIVE ACTION: REMOVED AND REPLACED PLATE/BRACKET IAW SRM 51-42-11//END//SDR AALA202209092411Cap · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT PASSENGER COMPARTMENT FLOOR SUPPORT STRUCTURE T-CAP LOCATED AT BS 986 AND S17R. REPLACED T-CAP PER SRM 53-70-51-2R-4.SDR SWAA2022090941302Scuff Plate · crackedCRACK ON SCUFF PLATE AT FWD POSITION OF FWD CARGO COMPARTMENT DOOR 2022-426965 / [01] TOOL USED: DIGITAL CALIPER P/N: 500-197-30; S/N: B20189516 ; DUE DATE: 03-DEC-22.;[02] REPAIRED SCUFF PLATE AT FWD POSITION OF FWD CARGO COMPARTMENT DOOR I.A.W. BOEING 737-70SDR SWAA2022090741387Intercostal · corrodedCORROSION ON FLOOR SUPPORT BS 947+1 LBL26 WL 208 / [01] VERIFIED NO SRM APPLICABILITY FOR THIS PART.;[02] VERIFIED THAT THERE IS NO SRM APPLICABLE FOR THIS FLOOR SUPPORT.;[03] VERIFIED CORRECTIVE ACTION #1;[04] REMOVED CORROSION ON FLOOR SUPPORT. ORIGINAL THICSDR SWAA2022090741396Sidewall Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 460+2. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 460+2' REMOVED 0.020' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS PER SRM 53-00-SDR SWAA2022090741398Sidewall Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 500+5; BS 500+10; BS 500+15; BS 500+20; BS 500A+7; BS 500A+11; BS 500B+7; BS 500B+11; BS 500B+15; BS 500B+20. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500BSDR SWAA2022090741400Sidewall Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 500D+20; BS 500E+2; BS 500E+7; BS 500E+11; BS 500E+15; BS 500E+20; BS 500F+2; BS 500F+11; BS 500F+15; BS 500F+20. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS SDR SWAA2022090741399Sidewall Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 500C+2; BS 500C+7; BS 500C+11; BS 500C+15; BS 500C+20; BS 500D+2; BS 500D+6; BS 500D+11. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500C+20' REMOVED 0.020' ISDR SWAA2022090741401Sidewall Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 500G+2; BS 500G+6; BS 500G+11; BS 500H+2; BS 500H+7; BS 500H+11; BS 500H+15. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500G+11' REMOVED 0.025' IN A AREA OF SDR SWAA2022090741405Sidewall Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 500A+2; BS 500A+6; BS 500A+11; BS 500A+15; BS 500B+7; BS 500B+11. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500B+7'' REMOVED 0.020' IN A AREA OF 1'X1' ORIGISDR SWAA2022090741406Sidewall Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 500B+16; BS 500B+20; BS 500C+2; BS 500C+7; BS 500C+11; BS 500C+16; BS 500C+20; BS 500D+2; BS 500D+7; BS 500D+11. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 5SDR SWAA2022090741408Sidewall Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 500G+2; BS 500G+7; BS 500G+15; BS 500G+20; BS 500H+2; BS 500H+7; BS 500H+11; BS 500H+15. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500H+7'' REMOVED 0.020' ISDR SWAA2022090741407Sidewall Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 500D+15; BS 500D+20; BS 500E+2; BS 500E+7; BS 500E+11; BS 500E+15; BS 500E+20; BS 500F+4; BS 500F+7; BS 500F+11. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 5SDR SWAA2022090741412Shield · corrodedCORROSION ON FWD CARGO BAY AFT DOOR SHIELD AT RBL 24 BS 480+14. / [01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED CORRECTIVE ACTION 1<BR><BR>VERIFIED MEASUREMENTS TABLE;[03] REMOVED DAMAGED SHIELD AT SDR SWAA2022090741409Shield · corrodedCORROSION ON FWD CARGO BAY FWD DOOR SHIELD AT RBL 24 BS 420+12; BS 420+17. / [01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED CORRECTIVE ACTION 1<BR><BR>VERIFIED MEASUREMENTS TABLE;[03] REMOVED DAMAGEDSDR SWAA2022090741417Support Angle · corrodedCORROSION ON FSD MOPSILL THRESHOLD SUPPORT ANGLE BS294.5+11-BS312+4 RBL56 WL 209 / [01] SRM APPLICABILITY 53-10-15-1A-2. REMOVED CORROSION ON FSD MOPSILL THRESHOLD SUPPORT ANGLE AT BS 312+4 -BS 312+5 PER SRM 51-10-02. MAXIMUM MATERIAL REMOVED WAS 1'X1'X .011'.SDR ASAA2022081239739Floor Panel · delaminatedFLOOR PANEL P/N 141A5810-236 DELAM. GROUNDED - YES. REPAIRED DELAM ON FLOOR PANEL P/N: 141A5810-236 IAW B737-800 SRM: 53-00-50-2R-0 & 53-00-50-2R-7.SDR SWAA2022083041423Angle · crackedCRACK DOOR 315A ANGLE LOCATED AT LEVEL BS 1112 AT RBL 2 ON APU COMPARTMENT 2022-418584 / [01] TOOL USED: TEMPERATURE CONTROLLER: P/N P3015GOES00000; S/N 112031023; DUE DATE: 01-FEB-23.;[02] REPLACED LOC. DOOR 315A ANGLE LOCATED AT LEVEL BS 1112 AT RBL 2 ON APUSDR FDEA202208121988Panel · corrodedMAIN CARGO COMPARTMENT, R/H SIDE UNDER FLOOR AREA HAS EXFOLIATION CORROSION LOCATED AT STA 1248 RBL 108. REPAIRED CORROSION IN REFERENCE TO EA# 1-5710-T0370393SDR AALA202208231008Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORRODED FLOOR SUPPORT LOCATED AT BS 947, LBL 48. REPLACED FLOOR SUPPORT PER SRM 51-40-02-OG.SDR REXA2022081701884Stringer · corrodedSTRINGER 26L IS CORRODED BETWEEN F.S.985.00 AND F.S.1000 REPAIRED STRINGER 26L IAW ENDEAVOR EA CRJ953-13731SDR REXA2022081701882Intercostal · corrodedSTRINGER 26R INTERCOSTAL BETWEEN F.S.349 AND F.S.364 IS CORRODED. REMOVED AND REPLACED INTERCOSTAL STRINGER 26R, BETWEEN F.S.349 TO 364SDR REXA2022081701881Intercostal · corrodedINTERCOSTAL BETWEEN STRINGER 26R AND STRINGER 27 BETWEEN F.S.349 AND F.S.364 IS CORRODED. REMOVED AND REPLACED INTERCOSTAL BETWEEN STRINGER 26R AND STINGER 27 BETWEEN F.S.349 TO 364