JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR REXA2022051800950Intercostal · corrodedINTERCOSTAL 20R HAS CORROSION. AFT OF FS 379.00. REPLACED INTERCOSTAL 20R LOCATED AT FS319 TO FS349 REF CRJ900 SRM 51-42-06-01-001-001-A01, CRJ900 SRM 51-42-21-001-001-A01, DWG #SH670-31950 REV YSDR REXA2022051800949Intercostal · corrodedINTERCOSTAL 20R HAS CORROSION. FORWARD OF FS 379.00. REPLACED INTERCOSTAL 20R LOCATED AT FS310 TO FS319 REF CRJ900 SRM 51-42-06-001-001-A01, CRJ900 SRM 51-42-21-001-001-A01 DWG #SH670-31950 REV Y.SDR SWAA2022051795147Panel · deterioratedAFT CARGO PANEL FWD CUTOUT 142KW LOWER SIDE IS DETERIORATED (228-012). / [01] RECEIVED NEW PANEL 142KW AFT CARGO COMP. FWD DOOR CUTOUT; PANEL 142KW INSTALLATION IS ACCOMPLISHED ON CARD TTG8Q00B7SW6.;[02] VERIFIED STEP 1.SDR IXXA20220506104Fairing · corrodedWING TO BODY RH AFT LWR OF WW DOOR CUT OUT IB SIDE HAS CORROSION. FAS WO N431AZ-01-01 NON ROUTINE 00124SDR REXA2022050300776Intercostal · corroded3EACH FWD INTERCOSTALS ARE CORRODED AT AVIONICS DOOR SURROUNDING STRUCTURE FS 349.00-364.00, STR26L-26R. CA: REMOVED AND REPLACED INTERCOSTALS IAW CRJ 900SRM 51-40-11-001-001-A01, 51-42-21-001-001-A01, 53-21-23-001-003-A01 AND 51-42-06-001-001-A01. (2EA) SH670SDR IPXA2022042681494Structure · corrodedINSPECTION TYPE:CWING TO BODY SUPPORT STRUCTURE AT FS 1200 FROM WL 208 TO 133 RBL 70 HAS EXFOLIATED CORROSIONREMOVED AND REPLACED WITH TO BODY LOWER T CHORD SEGMENT PER SRM 51-40-02-0GSDR IPXA2022042081337Floor Panel · corrodedINSPECTION TYPE:3CRCB FLOOR PANEL P/N WSP0786-501 HAS CORROSION AT BETWEEN STA Y=475.0 - Y=503.175 AND X=-17.500 - X=-27.500.REMOVED, REPLACED CORRODED FLOOR PANEL P/N WSP0786-501 IAW DWG WSP0786 AND MD11 SRM 51-31-01. (MINOR)SDR DALA2022041802650None · noneSHIP 6821 EXCESSIVE CORROSION: RH SIDE PANEL BTW STA 1300 TO STA 1310 AT AFTER CARGO COMPARTMENT ,IT'S OUT OF LIMITS IN REFERENCE TO NRC 186. CORRECTIVE ACTION: SUMMARY OF NRC 00494 RH SIDE PANEL BTW STA 1300 TO STA 1310 AT AFTER CARGO COMPARTMENT WAS REPAIREDSDR QXEA2022041500155Tie Clip · corrodedRH FR 80 BETWEEN STGR 23 AND 25 RH CORROSION ON SUPPORT CLIP. REMOVED AND REPLACED AFT CARGO SUPPORT CLIP IAW 51-40-08.SDR 2024FA0000153Stiffener · crackedAFT FUSELAGE LOWER SKIN STIFFENER FOUND CRACKED. REPLACED WITH NEW STIFFENER.SDR F3LA2022091400105Floor Support · corrodedMAIN CABIN L/H FLOOR SUPPORT Y1292 HAS CORROSION ON UPPER FLANGE STA 16-STA20. REMOVED AND REPLACED Y1292 FLOOR SUPPORT STA 16-20 IAW A320 SRM 51-72-911-002SDR REXA2022060600970Stringer · corrodedSTR 24L CORRODED BETWEEN FS333-364. CORROSION MEASURES 7.0"X1.0"X.040" DEEP. REMOVE AND REPLACE STRINGER.SDR SWAA2022050394244Transition Panel · corrodedFWD CARGO BIN LT TRANS ANGLE CORRODED IN NUMEROUS AREAS STA 500 TO 500I. / [01] INSTALLED LH TRANSITION ANGLE AND SLICE REPAIR FROM STA 500D+10 TO STA 500I IAW SRM 53-00-53-2R-5. NUT PLATE INSTALLATION ON NEW TRANSITION ANGLE SECTION STILL REQUIRED.;[02] INSTASDR SWAA2022050394245Angle · corrodedFWD CARGO BIN RT TRANS ANGLE CORRODED IN NUMEROUS AREAS STA 500A TO 500I. / [01] REMOVED AND REPLACED R/H TRANSITION ANGLE PER SRM 51-10-02SDR SWAA2022050394248Support Angle · corrodedFWD CARGO BIN AFT FLRBD SUPPORT ANGLE CORRODED STA 500I LBL24 TO RBL24. / [01] REMOVED AND INSTALLED NEW PART PER SRM 51-10-02.;[02] C/W INSPECTIONSDR SWAA2022042794169Angle · corrodedDOT A-24-003 WIFI ADAPTER RING FORWARD BONDING STRAP ATTACH ANGLE CORRODED. / [01] EVALUATED ATTACH ANGLE FOUND 100% MATERIAL LOSE<BR>OUT OF LIMITS I.A.W SRM 51-10-02-0G-0;[02] REMOVED ATTACH ANGLE I.A.W SRM 51-40-02-0G-0;[03] VERIFIED MATERIAL FOR FABRICATIONSDR IPXA2022042681497Structure · corrodedINSPECTION TYPE:CWING TO BODY SUPPORT STRUCTURE LOWER T CHORD AT FS 1180-1240 LBL 57.5 IS EXFOLIATEDREMOVED AND REPLACED WING TO BODY LOWER T CHORD SEGMENT PER SRM 51-40-02-0GSDR SWAA2022042593740Baffle · crackedFWD CARGO BAFFLE AT STA.400-STA.420; STR.26L; WL 206; CRACKED / [01] REMOVED BAFFLE AT FWD CARGO COMPARTMENT BETWEEN FS 400-420 STR 26L WL 206 IN REF B737-700 SRM 51-40-02-0G-0;[02] LOCATED AND DRILLED BAFFLE AT FWD CARGO COMPARTMENT BETWEEN FS 400-420 STR 26LSDR SWAA2022041893791Floorboard · looseEE BAY; FLOORBOARD NOT SECURED NEAR P92. / [01] SECURED FLOORBOARD IN EE BAY NEAR P92 USING SOPM 20-50-01;[02] VERIFIED CORRECTIVE ACTIONS STEP 1.SDR IXXA2022041303Intercostal · corrodedALC INTERCOASTAL STATION 1087-1107 LBL42 HAS CORRODED NUTPLATES AND CORROSION ON SURFACESDR REXA2022060901087None · corrodedRH FLOOR SILL IS CORRODED AROUND NUT PLATES AT FS 280. REMOVED AND REPLACED FLOOR SILL IAW CRJ 700 SRM 51-42-06-001-001-A01, 51-42-13-001-001-A01, AND 51-42-15-001-001.SDR SWAA2022051193794Angle · corrodedR/H TRANSITION ANGLE STA 767 THROUGH STA 787; RBL 21 SHOWS EVIDENCE OF CORROSION. / [01] REPLACED SECTION OF TRANSITION ANGLE FROM STA. 727F +10 TO 767 ON NR# TTG8Q00BU45D;[02] C/W INSPECTION.SDR SWAA2022051193800Angle · corrodedR/H TRANSITION ANGLE STA 747 THROUGH STA 767; RBL 21 SHOWS EVIDENCE OF CORROSION. / [01] REMOVED CORR. R/H TRANSITION ANGLE STA. 747 - 767 PER SRM 51-10-02 ; MATERIAL MESUMENT ( .006 ) FOUND OUT OF LIMITS PER SRM. 53-00-53-1A-1;[02] REPLACED SECTION OF TRANSITSDR SWAA2022051193801Angle · corrodedR/H TRANSITION ANGLE STA 727J THROUGH STA 747; RBL 21 SHOWS EVIDENCE OF CORROSION. / [01] REMOVED CORR. R/H TRANSITION ANGLE STA. 727J-747 - PER SRM 51-10-02 ; MATERIAL MESUMENT ( .006 ) FOUND OUT OF LIMITS PER SRM. 53-00-53-1A-1;[02] REPLACED SECTION OF TRANSSDR SWAA2022051193802Angle · corrodedR/H TRANSITION ANGLE STA 727I THROUGH STA 727J; RBL 21 SHOWS EVIDENCE OF CORROSION. / [01] REMOVED CORR. R/H TRANSITION ANGLE STA. 727I-727J ; PER SRM 51-10-02 ; MATERIAL REMOVED MESUMENT ( .006 ) FOUND OUT OF LIMITS PER SRM. 53-00-53-1A-1;[02] REPLACED SECTIOSDR SWAA2022051193803Angle · corrodedR/H TRANSITION ANGLE STA 727G THROUGH STA 727G+10; RBL 21 SHOWS EVIDENCE OF CORROSION. / [01] REMOVED CORR. R/H TRANSITION ANGLE STA. 727G THROUGH 727G+10 ; PER SRM 51-10-02 ; MATERIAL REMOVED MESUMENT ( .005 ) FOUND OUT OF LIMITS PER SRM. 53-00-53-1A-1;[02] RSDR SWAA2022051193804Angle · corrodedR/H TRANSITION ANGLE STA 727F +10; RBL 21 SHOWS EVIDENCE OF CORROSION. / [01] REMOVED CORR. R/H TRANSITION ANGLE STA. 727F- ; PER SRM 51-10-02 ; MATERIAL REMOVED MESUMENT ( .005 ) FOUND OUT OF LIMITS PER SRM. 53-00-53-1A-105;[02] REMOVE AND REPLACE R/H TRANSITSDR SWAA2022051193798Web · corrodedAFT CARGO DOOR THRESHOLD WEB HAS EVIDENCE OF CORROSION FROM STA 794 THROUGH STA 847; S-25R / [01] CORROSION FOUND OUT OF LIMITS PER SRM 53-00-53-1A-1<BR>REMOVED FASTENERS OF AFT CARGO THRESHOLD WEB PER SRM 51-40-02.;[02] INSTALLED AFT CARGO WEB P/N 146A8123U25SDR R61A2022050500323Seat Track · corrodedFWD FUSELAGE SEAT TRACK RH INB CORRODED AT FR 18-19. R&R IAW EMB 175 SRM 51-41-01, 51-41-02, 51-43-01 AND 51-43-02.SDR SWAA2022050293872Angle · brokenAFT CARGO BAY LOWER LAV BULKHEAD ANGLE BROKEN BS847 LBL10 WL165 / [01] REMOVED THE DAMAGED ANGLE AND LOCATED AND DRILLED NEW BULKHEAD ANGLE BS 847 LBL10 WL 165 PER SRM 51-40-05-0G-0 AND DWG 149A8102. OK TO INSTALL;[02] NO DATA FOUND ON SRM PART MUST BE REPLACESDR SWAA2022050293663Support Plate · corrodedFWD CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE AS AREAS OF CORROSION BS500A TO BS500I RBL23 WL 156 / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500C+10 RBL 23 WL 156; FOUND 0.015 REMOVED FORM ORIG 0.040 IN NUMEROUS 1'X1' ASDR SWAA2022050293664Support · corrodedFWD CARGO BAY LOWER BULKHEAD SUPPORT AT BS500I HAS A AREAS OF CORROSION RBL21 TO LBL21 WL156 / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500I RBL 15 WL 156; FOUND 0.020 REMOVED FORM ORIG 0.071 IN NUMEROUS 1'X1' AREAS FOUND TSDR SWAA2022050293665Plate · corrodedAFT CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT PLATE HAS AREAS OF CORROSION BS727D TO BS787 LBL21 WL156 / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 727G+10 LBL 21 WL 156; FOUND 0.015 REMOVED FORM ORIG 0.040 IN NUMEROUS 1'X1' ARSDR SWAA2022050293666Plate · corrodedAFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE HAS AREAS OF CORROSION BS727F TO BS767 RBL21 WL156 / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 727I+10 RBL 21 WL 156; FOUND 0.015 REMOVED FORM ORIG 0.040 IN NUMEROUS 1'X1' ARSDR SWAA2022050293667Shield · corrodedAFT CARGO BAY SHIELD BS767 TO BS787 HAS AREAS OF CORROSION RBL21 WL156 / [01] EVALUATED CORROSION ON SHIELD BS 767 TO 787 RBL 21 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTISDR SWAA2022050293668Shield · corrodedAFT CARGO BAY LOWER ATTACH ANGLE COMMON TO SHIELD HAS AREAS OF CORROSION BS767 TO BS787 RBL21 WL156 / [01] EVALUATED CORROSION ON ATTACH ANGLE BS 767 TO 787 RBL 21 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 5SDR SWAA2022050293669Splice · corrodedAFT CARGO BAY FLOOR PANEL SPLICE HAS CORROSION BS727I+4 RBL16 WL156 / [01] EVALUATED CORROSION ON STRAP BS 727I+4 RBL 16 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTIOSDR SWAA2022042893616Angle · corrodedAFT CARGO PIT LT Z ANGLE BETWEEN BS 727E - 807+10, LBL 23, WL 155 CORRODED ON UPPER SURFACE. REMOVED CORROSION FROM LH Z ANGLE, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. CUTOUT DAMAGE SECTION OF Z ANGLE AND REMOVED IAW SRM 53-00-53-2R-5. FABRICATED SDR SWAA2022042893617Shield · corrodedAFT CARGO PIT FWD SHIELD BETWEEN STA 767+2' TO STA 767+10' RBL 23 WL 155 HAS CORROSION ON UPPER AND LOWER SURFACE / [01] REMOVED CORROSION ORIGINAL T= .050' LOSS OF .006' REMAING T= .044' FOUND TO BE OUT OF LIMITS IAW SRM 53-60-15-1A-1 TOOLING INFO AAR 35351 CSDR IPXA2022042881539Structure · corrodedINSPECTION TYPE:CWING TO BODY STRUCTURE LOWER T CHORD AT FS 1180 TO FS 1240 RBL 50 LOWER FLANGE WAS EXFOLIATEDREMOVED AND REPLACED LOWER T CHORD PER SRM 51-40-02-0GSDR REXA2022042700755Cleat · corrodedSTRINGER 22R BETWEEN FS 319.70 TO FS 333 HAS 2 STRINGER CLIPS CORRODED. - FABBED CLEATS FOR 22R 319 - 333 IAW CRJ 900 SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01, 53-00-06-001-001-A01, 51-40-11-001-001-A01, & DRAWINGS SH670-35625 & SH670-31253.SDR REXA2022042700730None · corrodedSTGR 20L ATTACHMENT CLIP TO FS 295 FRAME IS CORRODED. - REPLACED CLIP AT FS 295 20L IAW CRJ 900 SRM 51-40-11-001-001-A01, 51-42-06-001-001-A01, 51-42-21-001-001-A01.SDR SWAA2022042793613Angle · crackedA-061 DOT 023 A-061 DOT 021 AFT CARGO PIT LOWER END OF VERTICAL BEAM FOR WASTE TANK CLOSE OUT AT STA 867 LBL 14 WL 155 ATTACH ANGLE CRACKED / [01] REMOVED CRACKED AFT CARGO LOWER VERTICAL BEAM WASTE TANK ATTACH ANGLE AT STA 867 LBL 14 AND REPLACED WITH NEW ATTSDR SWAA2022042793622Angle · corrodedA-061 DOT 031 AFT CARGO PIT R/H Z ANGLE FROM STA 727G TO STA 747+15' RBL 23 WL 155 CORROSION ON UPPER SURFACE / [01] REMOVED CORROSION FROM RH ZEE ANGLE STA 727G-747+15 ORIINAL T= .045' LOSS OF .009' REM T= .036' FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2SDR SWAA2022042793620Angle · corrodedA-061 DOT 032 AFT CARGO PIT ATTACH ANGLE FOR FWD SHIELD STA 767 TO STA 767+15' RBL 23 WL 155 CORROSION AT NUTPLATE HOLES LOWER SURFACE / [01] REMOVED CORROSION FROM ATTACH ANGLE. ORIGINAL T=.050' LOSS OF .006' REMNING .044' FOUND TO BE UT OF LIMITS IAW SRM 53-SDR SWAA2022042793623Baffle · corrodedA-061 DOT 033 AFT CARGO PIT BAFFLE UNDER R/H Z ANGLE BETWEEN STA 747 AND STA 767 RBL 23 WL 155 CORRODED AT NUTPLATES HOLES / [01] REMOVED DAMAGE PART IAW SRM 51-40-02-0G-0;[02] REMOVED CORROSION ON DAMAGE PARTS IAW SRM 51-10-02-0G-0 ITEM 15;[03] EVALUATED ALLOSDR SWAA2022042093513Panel · corrodedCORROSION.....AFT CARGO COMPARTMENT AFT BULKHEAD PANEL 141UW HAS EXFOLIATED CORROSION. / [01] RECEIVED NEW AFT CARGO PANEL 141 UW; NEW PANEL TO BE INSTALLED ON CUSTOMER BAR CODE TTG8Q00ASNPF;[02] VERIFIED STEP 1.SDR ASAA2022041238025Intercostal · corrodedAFT WET AREA, CORROSION ON INTERCOSTAL AT AFT O/B FLOOR MOUNT FOR LAV E. GROUNDED - YES. REMOVED CORROSIONORIGINAL THICKNESS .080, REMAINING .041, REMOVED .039 AND FOUND TO BE OUT OF LIMITS IAW B737-900ER SRM 53-70-51-1A-1.REMOVED AND REPLACED INTERCOSTAL P/N SDR IXXA2022060210012Floor Support · corrodedCORROSION ON FLOOR SUPPORTSDR REXA2022052600992None · corrodedLH SIDE SEAT RAIL AT FS 670 - 720 HAS MULTIPLE SPOTS OF CORROSION, . REMOVED AND REPLACED SEAT RAIL IAW CRJ 900 AMM 53-00-49-000/400-801-A13
Back to JASC 5320