JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022042786924Floor Support · crackedCABIN FLOOR INTERCOSTAL CRACKED AT UPPER FLANGE B.S. 312 +14' RBL. 31' WL. 208. / [01] REMOVED DAMAGE INTERCOSTAL AT STA 312+14';RB.L 31';WL.208 AS PER B737-700 REF SRM 51-40-02-0G-0;[02] LOCATED AND DRILLED NEW INTERCOSTAL AT STA 312+14';RBL 31';WL.208 AS PERSDR SWAA2022042786926Intercostal · crackedCABIN FLOOR INTERCOSTAL CRACKED AROUND FASTENER HOLE AT B.S.270 +3 B.L. 0' WL. 208. / [01] REMOVED DAMAGE INTERCOSTAL AT STA 270+3';B.L 0';WL.208 AS PER B737-700 REF SRM 51-40-02-0G-0;[02] VERIFIED STEP # 1;[03] LOCATED AND DRILLED NEW INTERCOSTAL AT STA 270+3SDR SWAA2022042686727Angle · corrodedIN THE FORWARD CARGO COMPARTMENT THE L/H TRANSITION ANGLE HAS NUMEROUS CORROSION AREAS FROM STA 514 TO STA 500I. / [01] LOCATED AND DRILLED HOLES FOR NEW PART FROM LBL 24 STA 500 TO STA 500I PER SRM 51-40-05;[02] L/H TRANSITION ANGLE REPLACED FROM STA 500-500ISDR SWAA2022042686726Angle · corrodedIN THE FORWARD CARGO COMPARTMENT THE 'L' ANGLE IS CORRODED AT STATION 500I FROM RBL 24 TO LBL 24. / [01] REMOVED AND REPLACED L ANGLE AT STA 500I FROM RBL 24 TO LBL 24 REF SRM 51-40-02.;[02] INSPECTED WORK PERFORMEDSDR SWAA2022042686728Angle · corrodedIN THE FORWARD CARGO COMPARTMENT THE R/H TRANSITION ANGLE HAS NUMEROUS AREAS OF CORROSION FROM STA 500A TO STA 500I. / [01] REMOVED AND REPLACED R/H TRANSITION ANGLE PER SRM 51-40-02;[02] 4 EA. FASTENERS MISSING IN ANGLE AT R/H AFT BULKHEAD THAT WERE REMOVED FSDR SWAA2022042686729Web · crackedCORROSION ON AFT CARGO DOOR CUTOUT BEADED WEB / [01] FOUND CORROSION DAMAGE TO BE OUT OF LIMITS PER SRM 53-60-15-1A-1.015 DEPTH; .030 REMAING;.045 WEB.;[02] STEP 1 C/W;[03] REMOVED BEADED WEB FOR REPLACEMENT PER SRM 51-40-02.;[04] MATCH DRILLED AND COUNTERSANKSDR SWAA2022042686732Angle · corrodedCORROSION ON L/H TRANSITION ANGLE STA 747-767 / [01] CORROSION IS OUT OF LIMITS .REMOVED L/H TRANSITION ANGLE FROM STA 727G+10 TO STA 807 +10 FOR REPLACEMENT PER SRM 51-40-02.;[02] LOCATED NEW SECTION FROM STA. 727G + 10 TO STA. 807 + 10 ; AND DRILL HOLES PER SDR SWAA2022042686736Angle · corrodedCORROSION ON R/H TRANSITION ANGLE STA 727H-727I / [01] COMPLIED WITH MEASUREMENTS REQUIREMENT.;[02] REMOVED AND REPLACED RH TRANSITION ANGLE STA 727E +10 TO STA 767 PER SRM 53-00-53-2R-5. REFERENCE NONROUTINE TTG8Q00BFQSU FOR WORK ACCOMPLISHED.;[03] INSPECTED SDR SWAA2022042686737Angle · corrodedCORROSION ON R/H TRANSITION ANGLE STA 727G-727H / [01] CORROSION FOUND TO BE OUT OF LIMITS. REMOVED R/H TRANSITION ANGLE FROM STA 727E+10 TO STA 767 FOR REPLACEMENT PER SRM 51-40-02.;[02] LOCATED HOLES ON NEW TRANSITION ANGLE STA 727E+10 TO 767 PER SRM 51-40-0SDR SWAA2022042686740Angle · corrodedCORROSION ON R/H TRANSITION ANGLE STA 767-787 / [01] MEASUREMENT REQUIREMENT .;[02] REMOVED AND REPLACED PER SRM 51-40-02 .SDR SWAA2022042586847Shield · corrodedFWD CARGO;CARGO DOOR SURROUND STRUCTURE AFT SHIELD CORRODED AT TOP SURFACE. / [01] REMOVED CORROSION ON AFT SHIELD REF. B737-7 SRM 51-10-02-0G-0 FOUND SEVERAL CRACKS ON PANEL OUT OF LIMITS REF. B737-7 SRM 53-30-15-1A-1;[02] RECEIVED NEW SHIELD AT FWD CARGO COMSDR SWAA2022042586859Channel · corrodedAFT CARGO COMPARTMENT L/H Z CHANNEL FROM STA. 727 TO STA 847 AT NUT PLATE HOLES WITH DEEP CORROSION / [01] REMOVED CORROSION ON AFT L/H CARGO Z CHANNEL FROM STA 727 TO STA 847 I.A.W. SRM 51-10-02-0G-0; OUT OF LIMITS PASS THROUGH I.A.W 53-00-53-1A-2.;[02] VERIFSDR SWAA2022042090989Transition Panel · missingSEVERAL NUT PLATES MISSING AFT CARGO R/H TRANSITION ANGLE STA 727F-727H / [01] REMOVED AND REPLACED RH TRANSITION ANGLE AND BONDED NUTPLATES STA 727E +10 TO STA 767 PER SRM 51-40-10-2R-0 AND SRM 53-00-53-2R-5. REFERENCE NONROUTINE TTG8Q00BFQSU FOR WORK ACCOMPLSDR SWAA2022041987433Tie Down · corrodedCORROSION ON TIE DOWN LOC BS 495 BTW STR 18L TO STR 25L FWD CARGO COMPARTMENT 2022-148308 / [01] REPLACED TIE DOWN LOC BS 495 BTW STR 18L TO STR 25L FWD CARGO COMPARTMENT IAW B737-700 SRM 51-40-02;[02] REPLACED TIE DOWN LOC BS 495 BTW STR 18L TO STR 25L FWD CASDR SWAA2022041287468Transition Panel · corrodedFORWARD CARGO COMPARTMENT CORROSION FOUND ON RH TRANSITION ANGLE UPPER SURFACE FORM STA 500A-500B; RBL 24; AND WL 156 / [01] FOUND DAMAGE TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2;[02] REMOVED R/H TRANSITION ANGLE FROM STA 500A TO STA 500I; PICKED UP HOLES; DESDR SWAA2022041287466Support Angle · corrodedFORWARD CARGO COMPARTMENT CORROSION FOUND ON AFT BULKHEAD FLOOR SUPPORT ANGLE UPPER SURFACE AT STA 500I; LBL 24 TO RBL 24; AND WL 156. / [01] FOUND TO BE OUT OF LIMITS IAW SRM 53-30-08-1A-1 REMOVED ANGLE PER SRM 51-40-02; DRILLED NEW PART; AND OK TO INSTALL;[0SDR SWAA2022040886958Channel · corrodedAFT CARGO COMP. R/S FLOOR LEVEL. Z-CHANNEL ASSY. ATTACHMENT HOLES FOUND WITH EXFOLIATION CORROSSION . ( MRK. RED CIRCLE ) ' OFF A/C PART' AFT CARGO COMP. R/S FLOOR LEVEL. -CHANNEL ASSY. ATTACHMENT HOLES FOUND WITH EXFOLIATION CORROSSION . ( MRK. RED CIRCLE ) 'SDR REXA2022040700587Stringer · corrodedCORROSION FOUND ON STGR 20R BETWEEN FS661+90-177. - COMPLIED WITH EA CRJ953-13031 REV A.SDR REXA2022040100554Beam · corrodedFLOOR BEAM AT RBL9 HAS MULTIPLE SPOTS OF CORROSION FROM FS1000-FS1088. CA:REPAIRED IAW CRJ 900 SRM 53-00-41-201-001-A03 AND IAW ENDEAVOR AIR EA CRJ953-12550 REV IR DATED 3/09/2022SDR REXA2022040100553Beam · corrodedFLOOR BEAM AT LBL9 HAS MULTIPLE SPOTS OF CORROSION FROM FS1000-FS1088. CA:REPAIRED IAW CRJ 900 SRM 53-00-41-201-001-A03 AND IAW ENDEAVOR AIR EA CRJ953-113047 REV A DATED 3/11/2022SDR REXA2022040100552Beam · corrodedFLOOR BEAM AT LBL9, FS1015 TO 1051 REQUIRES SPLICE REPAIR PER CRJ 900 SRM 53-00-41 DUE TO CORROSION. CA:REPAIRED IAW CRJ 900 SRM 53-00-41-201-001-A01.SDR CALA2022032500774Floor Support · corrodedTRANSCRIBED FROM HAECO NR 9284825. B757-53-3-0579/CBN AFT WET AREA FLOOR SUPPORT CHANNEL CORRODED AT FASTENER HOLE BS 1675, BL 0. DOT: T679. REMOVED AND REPLACED FLOOR SUPPORT CHANNEL IAW B757-200 SRM 51-4 0-02 AND BAC DWG 146N5230 REV-. REMOVED AND REINSTALLESDR GTIA2022032436339Skin Panel · gougedCOURSE ON FUSELAGE SKIN PNL FINAL FR. 27-28 AND STR 39LH-40LH DE. L= 35MM W= 3MM D= 1.2MM REF-01279970301 GENERATED REF LTPR NRI 5001145967-0010.-REVIEWED NR# 5001145967-0010 AND TC 1003703926-0010. REPAIR WAS ACCOMPLISHED I.A.W SPIRIT EO 5321-2214 REV. 00, WISDR GTIA2022032436338Hinge Fitting · corrodedRUDDER HINGE ARM #7 CORRODED RIB 11 RAF-01 2799703-02 CREATED. REF LTPR NRI 5001142604-0010.-VERIFIED NR# 5001140903-0060 AND TC 1003697579-0010.PERFORMED REPAIR BY REPLACEMENT OF RUDDER HINGE ARM BR#7 I.A.W. EO 5536-2203 REV.00 SDR CREATEDSDR FDEA202203230660Strap · corrodedWHILE REMOVING THE APU INLET DUCT TO F.O.M. CORROSION WAS FOUND ON THE FWD SIDE OF THE DUCT CUTOUT. REMOVED & REPLACED CORRODED STRAP ON APU INLET DUCT CUTOUT FWD STRAP WITH ONE FABRICATED ON TRAVELER T22/1605340 PART # FX148N3138-20 IAW SRM 51-40-02 & DRASDR REXA2022050300788Web · corrodedSERVICE DOOR SEAL STRIKER, UPPER ANGLE, LOWER ANGLE, AND BOTH CENTER FITTINGS HAVE SIGNS OF CORROSION. CA: REPLACED SERVICE DOOR SEAL STRIKER, UPPER ANGLE, LOWER ANGLE, AND BOTH CENTER FITTINGS IAW CRJ 900 SRM 51-42-06-001-001-A01, 51-42-36-001-001-A01, 51-40SDR REXA2022050300787Fitting · corrodedSERVICE DOOR SEAL STRIKER, UPPER ANGLE, LOWER ANGLE, AND BOTH CENTER FITTINGS HAVE SIGNS OF CORROSION. CA: REPLACED SERVICE DOOR SEAL STRIKER, UPPER ANGLE, LOWER ANGLE, AND BOTH CENTER FITTINGS IAW CRJ 900 SRM 51-42-06-001-001-A01, 51-42-36-001-001-A01, 51-40SDR REXA2022050300786Angle · corrodedSERVICE DOOR SEAL STRIKER, UPPER ANGLE, LOWER ANGLE, AND BOTH CENTER FITTINGS HAVE SIGNS OF CORROSION. CA: REPLACED SERVICE DOOR SEAL STRIKER, UPPER ANGLE, LOWER ANGLE, AND BOTH CENTER FITTINGS IAW CRJ 900 SRM 51-42-06-001-001-A01, 51-42-36-001-001-A01, 51-40SDR REXA2022050300785Angle · corrodedSERVICE DOOR SEAL STRIKER, UPPER ANGLE, LOWER ANGLE, AND BOTH CENTER FITTINGS HAVE SIGNS OF CORROSION. CA: REPLACED SERVICE DOOR SEAL STRIKER, UPPER ANGLE, LOWER ANGLE, AND BOTH CENTER FITTINGS IAW CRJ 900 SRM 51-42-06-001-001-A01, 51-42-36-001-001-A01, 51-40SDR REXA2022050300775Buttstrap · corrodedFS280 CIRCUMFERENTIAL JOINT IS CORRODED BETWEEN STGR 24R TO STGR 26R CA: REPAIRED IAW ENDEAVOR EA CRJ953-13136 REV IR, DATED: 3/17/2022.SDR REXA2022050300770Plate · corrodedDOUBLER PLATE AT FS 565.00,BETWEEN 25L AND 26L CORRODED CA: REMOVED & REPLACED DOUBLER PLATE IAW CRJ 900 SRM 51-40-11-001-001-A01, 51-42-21-001-001-A01 & 51-42-27-001-001-A01.SDR REXA2022050300767Frame · corrodedINTERCOSTAL (LOWER STUB FRAME) CORRODED AT FS 549.00 BETWEEN STGR 25L AND STGR 26L. CA: REMOVED & REPLACED LOWER STUB FRAME IAW CRJ 900 SRM 51-40-11-001-001-A01, 51-42-20-001-001-A01 & 51-42-13-001-001-A01.SDR REXA2022050300766Frame · corrodedINTERCOSTAL (LOWER STUB FRAME) CORRODED AT FS 533.00 BETWEEN STGR 25L AND STGR 26L. CA: REMOVED & REPLACED LOWER STUB FRAME IAW CRJ 900 SRM 51-40-11-001-001-A01, 51-42-20-001-001-A01 & 51-42-13-001-001-A01.SDR SWAA2022050386875Fitting · corrodedEVIDENCE OF CORROSION IN AFT LAV B FWD I/B FITTING ADJACENT TO CENTER CLOSET / [01] REMOVED I/B FITTING AND BLOCK CORRODED AT LAVATORY B AS PER ZODIAC SPM 25-46-99;[02] VERIFIED STEP 1. OK TO APPLY REPAIR.;[03] REPAIRED AREA (INSTALLED NEW BLOCK) AFT LAVATORY SDR SWAA2022042585953Strap · corrodedT FLOOR SPLICE AT STA 727D + 5 WITH DEEP CORROSION. / [01] FOUND EXFOLIATE CORROSION ON FLOOR SPLICE STRAP AT STA 727 D +5; OUT OF LIMITS PER REF 737 -700 SRM 53-00-53-1A-2;[02] VERIFIED STEP 1.;[03] RECEIVED NEW FLOOR SPLICE STRAP P/N 146A9401-8; NEW STRAP TOSDR SWAA2022042086602Support Plate · corrodedAFT CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT PLATE HAS AREAS OF CORROSION BS727G+13 TO BS807 LBL21 WL 156 / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 747+10 LBL 21 WL 156; FOUND 0.015 REMOVED FROM ORIG 0.040 IN NUMEROUS 1'X1'SDR SWAA2022042086604Support Plate · corrodedAFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE HAS AREAS OF CORROSION BS 727E+12 TO BS767 RBL 21 WL156 / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 727F+10 RBL 21 WL 156; FOUND 0.015 REMOVED FROM ORIG 0.040 IN NUMEROUS 1'XSDR SWAA2022042086600Shield · corrodedAFT CARGO BAY ATTACH ANGLE UNDER SHIELD HAS CORROSION BS 767+3 RBL21 WL 156 / [01] EVALUATED CORROSION ON ATTACH ANGLE UNDER SHIELD BS 767+3 RBL 21 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02SDR SWAA2022042086603Shield · corrodedAFT CARGO BAY SHIELD HAS CORROSION BS 767+3 RBL21 WL 156 / [01] EVALUATED CORROSION ON SHIELD BS 767+3 RBL 21 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION 1.;[03] RSDR SWAA2022041886647Structure · corrodedCORROSION ON BS947 UPPER CHORD LBL24 WL 208 / [01] UPDATED STEP 1 FOR APPLICABILITY OF REFERENCE;[02] SRM 53-70-51-1A;[03] STEP 1 COMPLETE;[04] UPDATED STEP 2;[05] STEP 2 COMPLETE;[06] UPDATED STEP 3 AND 4 FOR INTERCOSTAL REMOVAL.;[07] UPDATE OF STEPS 5-17.;[0SDR SWAA2022041886648Structure · corrodedCORROSION ON BS947 UPPER CHORD RBL24 WL 208 / [01] UPDATED STEP 1 FOR APPLICABILITY;[02] STEP 1 COMPLETE;[03] UPDATED STEP 2. PER SRM 53-70-51;[04] CORROSION WAS FOUND TO BE OUT OF LIMITS AT BS 947 UPPER CHORD RBL 24 WL 208 AT 1'X1' AREA. ORIGINAL MATERIAL 0.1SDR SWAA2022041886586Skin · inadequateDUE TO FLOOR BEAM REPAIR 2 EACH FLOOR BOARD MOUNTING HOLES ON PANEL 241ACF REQUIRE FILLING/PLUGGING FOR RELOCATION / [01] IDENTIFIED PANEL IAW SRM 53-00-50-0I-1 TABLE 6 FIG 6.<BR><BR>DUE TO REPAIRS BEING COMPLETED TO AFT GALLEY FLOOR STRUCTURE; (2EA) INSERT LOSDR REXA2022040700624Stringer · corrodedFWD STRINGER 20R IS CORRODED FROM FS 280 TO FS 319. - COMPLIED WITH EA CRJ 953-13053 REV IRSDR SWAA2022040490889Angle · crackedCRACK FOUND IN A/C BAY ON UPPER ATTACH ANGLE AT BS 663 LBL 8. REMOVED FASTENERS FROM REPAIR AREA AND CUT OUT DAMAGE IAW SRM 57-10-10-2R-5 FIG 202 VIEW B. ACCOMPLISHED DVI OF REPAIR AREA & UNDERLYING STRUCTURE IAW SRM 57-10-10-2R-5 REPAIR 5 ITEM 4D. NO DEFECSDR AALA202203228199Shear Plate · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CABIN FLOOR SHEAR PLATE BETWEEN FR 69 AND FR 70 AT Y1400. REPLACED SHEAR PLATE PER SRM 51-72-11.SDR REXA2022060601016Frame · corrodedFS319.70 FRAME CORRODED BETWEEN STR 26R-26L. CORROSION MEASURES: 5.0"X.75"X.020" DEEP, 4.5"X.75"X.020" DEEP. REMOVE AND REPLACE FRAME.SDR REXA2022050300791Stringer · corrodedFS295 TO FS310 STR19R IS CORRODED CA: REPLACED STR20R IAW SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01SDR REXA2022050300789None · noneCABIN FLOOR SEAT TRACK RBL 9.0 CORRODED F.S.364 TO 379. CA: REPLACED SEAT TRACK AT RBL 9 FS. 349 TO 485 IAW CRJ900 AMM 53-00-49-000/400-801-A11.SDR REXA2022050300774Stringer · corrodedFS295 TO FS310 STR20R IS CORRODED CA: REPLACED STR20R IAW SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01SDR REXA2022050300773Intercostal · corrodedFS310 TO FS319 STR20R INTERCOSTAL IS CORRODED CA: REPLACED STR20R INTERCOSTAL IAW SRM 51-42-21-001-001-A01
Back to JASC 5320