JASC 5320

Service difficulty reports · 216,207

Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '5320'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SWAA2021081190422Strap · corrodedCORROSION ON STRAP AT AFT CARGO BAY BS800 RBL19 WL158. ; / [01] REMOVED CORROSION ON STRAP AT AFT CARGO BAY BS800 RBL19 WL158 IN L= 0.790' * W= 0.700'. IAW SRM 53-00-53-1A-2; [02] DAMAGE REMOVAL ACCOMPLISHED IAW SRM 51-10-02; [03] VERIFIED CORROSION REMOVAL; [Jul 1, 2021 · N750SA · Boeing 7377H4SDR SWAA2021080490230Angle · crackedRH FWD FLOOR TO SIDEPLATE ANGLE AT STA 400 TO STA 420 /RBL22 IS CRACKED ON AFT END ; / [01] FABRICATED NEW SIDEPLATE FROM BAC1496-444 7075T62 PER REF B737 SRM 51-40-05-0G-0 AND DWG 143A7501.; [02] VERIFIED STEP 1.<BR>OK TO TREAT AND PRIME.; [03] TREATED AND PRJul 1, 2021 · N417WN · Boeing 7377H4SDR IPXA2021072772139Web · crackedINSPECTION TYPE:A300MDCC BET FR 76 AND FR 77 SIDEWALL BOTTOM AREA INTER-COSTAL WEB CRACKED.FABRICATED PER SRM 53-18-18 FIG 3 AND DRAWING A53980389.Jul 1, 2021 · N144UP · Airbus A300F4622RSDR ASAA2021070135486Channel · corrodedAFT WET AREA R-2 MOP SILL HAS MULTIPLE AREAS OF CORROSION. GROUNDED - YES. BLENDED CORROSION FOUND TO BE OUT OF LIMITS IAW B737-700 SRM 57-70-15-1A-1 REMOVED AND REPLACED MOPSILL IAW B737-700SRM 51-40-02-0G-0W= 1.80 O=.080 R= .070 L= 3.20 D= .010.Jul 1, 2021 · N612AS · Boeing 737790SDR ASAA2021070135477Floor Support · corrodedMAIN CABIN AFT GALLEY AREA FLOOR BEAM CORRODED AT Y512.5 BETWEEN FR70-FR69 GROUNDED - YES. REMOVED CORROSION AND CHECKED THE LIMITS. ORIGINAL THICKNESS IS .160, REMAINING IS .100, .060 WAS REMOVED . OUT OF LIMITS REF A320 SRM 53-00-14. REMOVED AND REPLACED BEAJul 1, 2021 · N638VA · Airbus A320214SDR SWAA2021072689889Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 410.5; RBL 25; WL 157, VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53--1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FCB FLOOR TO SIDEWALL SUPPORT BS410.5; RBL25; WL157; Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689890Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 407; RBL 24; WL 156.5 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53--1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION FROM FCB FLOOR TO SIDEWALL SUPPORT BS407; Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689893Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 454.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS454.5'';LJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689894Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 514.25; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS514.25''Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689895Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500A+6.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS500A+6Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689896Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500A+14.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS500A+Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689897Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500B+10.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS500B+Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689898Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500C+2; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS500C+2;LJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689899Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500C+6.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS500C+6Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689900Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500C+12; LBL 24; WL 156.5 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS500C+Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689904Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 470.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS470.5;LBLJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689905Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 474.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS474.5;LBLJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689906Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 505; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS505;LBL25;WJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689907Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 510.25; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS510.25''Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689908Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 517; LBL 24; WL 156.5 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS517'';LBLJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689909Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 518.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS518.5'';LJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689910Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500A+10.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS500A+Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689911Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500B+14.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS500B+Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689912Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500B+17.75; LBL 24; WL 156.5 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FCB FLOOR TO SIDEWALL SUPPORT BS50Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689913Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500C+14.5; LBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION O FLOOR TO SIDEWALL SUPPORT BS500C+14.5Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689901Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500A+14.5; RBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689902Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500C+13; RBL 24; WL 156.5 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689903Support · corrodedCORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500C+14.5; RBL 25; WL 157 (MARKED). ; / [01] VERIFIED APPLICABILITY OF SRM 53-30-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE; [02] REMOVED CORROSION ON FCB FLOOR TO SIDEWALL SUPPORT BS 500Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690673Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+6; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB R/H SIDEWALL SUPPORT AT BS 727D+6 RBL 21 WL 157; REWORKED AREA; L: 4' W: 0.800' ORIGINAL THICKNESS 0.040' REMOVED MAT. 0.008' REMAINING MAT. 0.Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690675Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+7; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+7; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 0.7OO' W= 0.0670' D= 0.017' ALLOWABLE MATERIAL REMAINING ISJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690676Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 747+11; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 747+11; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 0.900' W= 0.0750' D= 0.016' MATERIAL REMAINING IS 0.024' FOJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690677Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 767+7; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 767+7; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 1.125' W= 0.0750' D= 0.013' MATERIAL REMAINING IS 0.027' FOUNJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690701Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+15; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+15; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 1`' W= 0.600' D= 0.018 ALLOWABLE MATERIAL REMAINING IS 0.Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690702Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+19; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 727D+19; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 1' W= 0.0580' D= 0.018' ALLOWABLE MATERIAL REMAINING IS 0Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690703Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 747+11; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 747+11; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 0.900' W= 0.0750' D= 0.016' MATERIAL REMAINING IS 0.024' FOJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690679Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 807+15; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 807+15; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 1' W= 0.700' D= 0.004' MATERIAL REMAINING IS 0.036' FOUND TJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690705Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 767+15; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 767+15; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 1.400' W= 1' D= 0.002' MATERIAL REMAINING IS 0.038' FOUND TJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690678Support · corrodedCORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 807+11; LBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB L/H FLOOR-TO-SIDEWALL SUPPORT; BS 807+11; LBL 21; WL 157 WITH FOLLOWING MEASURES L= 0.980' W= 0.750' D= 0.007' MATERIAL REMAINING IS 0.033' FOUJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689886Shield · corrodedCORROSION ON FCB AFT SHIELD BS 514; RBL 24; WL 156.5 (MARKED). ; / [01] NOT HAVE ENTRIES FOR ALLOWABLE DAMAGE IN SRM. THE PART MUST BE REPAIRED BY REPLACEMENT PER SRM. 51-10-02 ITEM 9.C.; [02] VERIFIED PART WILL BE REPLACE PER SRM 51-10-02 STEP 9.; [03] LOCATEJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072689887Shield · corrodedCORROSION ON FCB FORWARD SHIELD BS 433; RBL 25; WL 157 (MARKED). ; / [01] NOT HAVE ENTRIES FOR ALLOWABLE DAMAGE IN SRM. THE PART MUST BE REPAIRED BY REPLACEMENT PER SRM. 51-10-02 ITEM 9.C.; [02] VERIFIED PART WILL BE REPLACE PER SRM 51-10-02 STEP 9; [03] LOCATJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690681Shield · corrodedCORROSION ON ACB FWD SHIELD; BS 767+4; RBL 23; WL 157 (MARKED) ; / [01] THIS ITEM DOES NOT HAVE ALLOWABLE DAMAGE THEREFORE HAVE TO BE REPAIRED BY REPLACEMENT PER SRM 51-10-02-0G-0 STEP 9; [02] THIS ITEM DOES NOT HAVE ALLOWABLE DAMAGE THEREFORE HAVE TO BE REPAIJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690682Shield · corrodedCORROSION ON ACB FWD SHIELD; BS 767+8; RBL 22; WL 157 (MARKED) ; / [01] THIS ITEM DOES NOT HAVE ALLOWABLE DAMAGE THEREFORE HAVE TO BE REPAIRED BY REPLACEMENT PER SRM 51-10-02-0G-0 STEP 9; [02] LOCATED AND DRILLED NEW ACB FWD SHIELD BS 767-794 RBL 22 WL 157 IAWJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690699Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727C+18; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB R/H SIDEWALL SUPPORT AT BS 727C+18 RBL 21 WL 157; REWORKED AREA; L: 1.4' W: 0.700' ORIGINAL THICKNESS 0.040' REMOVED MAT. 0.008' REMAINING MATJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690698Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727C+14; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB R/H SIDEWALL SUPPORT AT BS 727C+14 RBL 21 WL 157; REWORKED AREA; L: 1.1' W: 0.600' ORIGINAL THICKNESS 0.040' REMOVED MAT. 0.009' REMAINING MATJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690697Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727C+10; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB R/H SIDEWALL SUPPORT AT BS 727C+10 RBL 21 WL 157; REWORKED AREA; L: 1.2' W: 0.650' ORIGINAL THICKNESS 0.040' REMOVED MAT. 0.010' REMAINING MATJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690696Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727C+6; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB R/H SIDEWALL SUPPORT AT BS 727C+6 RBL 21 WL 157; REWORKED AREA; L: 1.3' W: 0.750' ORIGINAL THICKNESS 0.040' REMOVED MAT. 0.008' REMAINING MAT. Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690695Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727C+2; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB R/H SIDEWALL SUPPORT AT BS 727C+2 RBL 21 WL 157; REWORKED AREA; L: 1.4' W: 0.650' ORIGINAL THICKNESS 0.040' REMOVED MAT. 0.010' REMAINING MAT. Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690694Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727B+13 - 727B+18; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB R/H SIDEWALL SUPPORT AT BS 727B+13 - 727B+18 RBL 21 WL 157; REWORKED AREA; L: 5'' W: 0.700' ORIGINAL THICKNESS 0.040' REMOVED MAT. 0Jul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690693Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727B+10; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON ACB R/H SIDEWALL SUPPORT AT BS 727B+10 RBL 21 WL 157; REWORKED AREA; L: 1.1' W: 0.550' ORIGINAL THICKNESS 0.040' REMOVED MAT. 0.007' REMAINING MATJul 1, 2021 · N913WN · Boeing 7377H4SDR SWAA2021072690692Support · corrodedCORROSION ON ACB R/H FLOOR-TO-SIDEWALL SUPPORT; BS 727E+2; RBL 21; WL 157 (MARKED) ; / [01] REMOVED CORROSION ON SIDEWALL SUPPORT AT BS 727B+2 RBL 21 WL 157; REWORKED AREA; L:1.1' W: 0.700' ORIGINAL THICKNESS 0.040' REMOVED MAT; 0.009' REMAINING MAT; 0.031 FOUJul 1, 2021 · N913WN · Boeing 7377H4
Back to JASC 5320