JASC 5321
Service difficulty reports · 49,350
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022072127918Floor Panel · pulledCABIN FLOOR PANEL 231XF UPPER SURFACE HAS PULLED FIBERS / [01] EVALUATED AND FOUND MISSING PLIES ON UPPER SURFACE. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1.<BR><BR>CLEANED AND PREPPED IAW SRM 53-00-50-2R-1 STEP A; C; E-F. SDR SWAA2022072127919Floor Panel · pulledCABIN FLOOR PANEL 241AF UPPER SURFACE HAS PULLED FIBERS / [01] EVALUATED AND FOUND MISSING PLIES ON UPPER SURFACE. NO DAMAGE TO COMPOSITE SUBSTRATE. FOUND TO BE REPAIRABLE IAW SRM 53-00-50-2R-1.<BR><BR>CLEANED AND PREPPED IAW SRM 53-00-50-2R-1 STEP A; C; E-F. SDR DALA2022071104826None · noneSHIP 3229 CORROSION LOWER SILL ENTRY AFT PASSENGER CREW DOOR 842 FR 66 AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED LOWER SILL ENTRY PER A320 SRM 51-72-11. (2314297)SDR DALA2022071004813Floorbeam · corrodedAIRCRAFT 0664, CORROSION ON FLOORBEAM ( UPPER AND LWR FACES) AT PASSENGER FLOOR STRUCTURE, STA. 365, BTW BL0 TO RBL 63. CORRECTIVE ACTION: CORROSION ON FLOOR BEAM WAS FOUND ON PREVIOUS REPAIR T CHORD, PREVIOUS REPAIR T CHORD BEAM WAS REPLACED PER B757-200 SRM SDR DALA2022071004812Floor Panel · brokenAIRCRAFT 0684, BROKEN (FLOOR PANEL) ( 2EA) FIBERGLASS PAN ASSY BTW STA 775 TO 780 AT FWD CARGO COMPARTMENT. CORRECTIVE ACTION: FIBERGLASS PAN ASSY BTW STA 775 TO 780 AT FWD CARGO COMPARTMENT WAS REPAIRED PER B757-200 CMM 25-00-66 REPAIR 1-1 PAR. 4. B. (2313565SDR SWAA2022081027371Floor Panel · delaminatedFLOOR PANEL 221DF HAS DELAMINATION ON LOWER SURFACE / [01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 2 TABLE 2.<BR><BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F.<BR><BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-1.<BRSDR SWAA2022080227425Bulkhead · delaminatedDELAMINATED BULKHEAD PANEL 141JW AT AFT CARGO COMPARTMENT 2022-383933 / [01] FABRICATED BULKHEAD PANEL 141JW AT AFT CARGO COMPARTMENT IAW B737-700 AMM 25-52-01-201-801; STEP 1(F) DWG: 453A2510 REV: E MATERIAL USED: CONOLITE P/N: BMS8-2TY45CL3GRA PO: 2022 11057SDR DALA2022071104825None · noneSHIP 3229 CORROSION ON COUPLING AT LEVEL STRINGER 26R BTW FR66 TO FR67 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED COUPLING AND FASTENERS PER A320 SRM 51-72-11 AND 51-42-11 (2313072)SDR DALA2022071104817Floor Support · corroded(LOG 2313483) DURING INSPECTION FOUND CORROSION ON FLOOR SUPPORT BTW FS: 951 AND LBL 27 TO LBL 50 AT PASSENGER CABIN. FLOOR SUPPORT WAS REPLACED AT NRC 00745.SDR DALA2022071004811Floorbeam · corrodedAIRCRAFT 0664, UPPER AND LWR FACES) AT PASSENGER CABIN FLOOR STRUCTURE, STA. 377, BTW BL0 TO LBL 63. CORRECTIVE ACTION: CORROSION ON FLOORBEAM (UPPER AND LWR FACES) AT PASSENGER CABIN FLOOR STRUCTURE, STA. 377, BTW BL0 TO LBL 63. WAS FOUND ON PREVIOUS REPAIR TSDR DALA2022071004810Floorbeam · corrodedAIRCRAFT 0664, CORROSION ON FLOORBEAM ( UPPER AND LWR SIDE) AT PASSENGER CABIN, STA. 324, AT RBL 46 AND FROM RBL 54 TO RBL 64. CORRECTIVE ACTION: CORROSION ON FLOORBEAM (UPPER AND LWR SIDE) AT PASSENGER CABIN, STA. 324, AT RBL 46 AND FROM RBL 54 TO RBL 64. WASSDR DALA2022070904808Frame · wornAIRCRAFT 0664, WEAR ON PREVIOUS REPAIR ON FRAME STA 1320 BTW S-27R-S26R AND S-27L-S-26L AT AFT CARGO COMPARTMENT. CORRECTIVE ACTION: PREVIOUS REPAIR ON FRAME STA 1320 BTW S- 27R-S26R AND S-27L-S-26L AT AFT CARGO COMPARTMENT WAS REPLACED PER B757-200 SRM 53-00-SDR SWAA2022080427092Floor Panel · crackedCRACK FLOOR PANEL 221GF AT FWD GALLEY AREA 2022-398263 / [01] TOOL USED: CALIPER P/N: 500-197-30 S/N: 15120589 DUE DATE: 28-NOV-2022;[02] REPLACED FLOOR PANEL 221GF AT FWD GALLEY AREA I.A.W B737-700 AMM 53-21-00-400-801 SEE INDIVIDUAL SIGNOFF BELOW;[03] REPLACSDR SWAA2022080427099Floor Panel · brokenBROKEN FLOOR PANEL 231JF AT PASSENGER CABIN 2022-398267 / [01] TOOL USED CALIPER P/N: 500-197-30 S/N: 15120589 DUE DATE: 28-NOV-2022;[02] TOOL USED: HOT BONDER P/N HCS9200B-AV S/N:18196127 DUE DATE: 16-JAN-23;[03] TOOL USED: SCALE P/N: CL5000 S/N: AE-408753 DUSDR SWAA2022080427102Floor Panel · crackedCRACK FLOOR PANEL 242XF AT AFT GALLEY AND LAV 2022-398272 / [01] TOOL USED: CALIPER P/N: 500-197-30 S/N: 15120589 DUE DATE: 28-NOV-2022;[02] REPLACED CRACK FLOOR PANEL 242XF AT AFT GALLEY AND LAV I.A.W B737-700 AMM 53-21-00-400-801;[03] CORRECTED STEP 2; REPLASDR SWAA2022072827073Floor Panel · crackedFWD CABIN FLOOR 231EF HAS A PUNCTURE IS CRACKED ON EDGE / [01] PREPARED DAMAGED AREA ON FLOOR PANEL #231EF FOR REPAIR PER B737 SRM 53-00-50-2R-4 PARAG 3.K;[02] OK TO REPAIR PANEL 231EF;[03] REPAIRED PANEL #231EF AT DAMAGED AREA PER B737 SRM 53-00-50-2R-4 PARAGSDR SWAA2022081826586Floor Panel · damagedFWD FLOOR PANEL 222DF HAS A RIPPED OUT INSERT ALONG THE O/B EDGE. (MARKED) / [01] IDENTIFIED FWD PANEL 222DF IAW SRM 53-00-50-0I-1 FIGURE 2 TABLE 2. FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW 53-00-50-1A-1 PARA 4.F. <BR>DAMAGE WILL BE REPAIRED IAW SRM 53-0SDR SWAA2022081826585Floor Panel · pulledFWD FLOOR PANEL 222BF UPPER SURFACE HAS AREAS OF PULLED STRANDS. / REMOVED ALL INSERTS TO FACILITATE REPAIR IAW SRM 53-00-50-2R-1 PARA 3B<BR>REMOVED PREVIOUS REPAIR AND ALL DAMAGE NOTED AND CLEANED REPAIR AREAS IAW SRM 53-00-50-2R-1 PARA 3C-F;[02] VALIDATED APSDR SWAA2022081826583Floor Panel · pulledFWD FLOOR PANEL 221EF UPPER SURFACE OF FWD EDGE HAS AREA OF PULLED STRANDS. / REPAIRS TO BE ACCOMPLISHED IAW SRM 53-00-50-2R-1<BR><BR>REMOVED ALL INSERTS TO FACILITATE REPAIR IAW SRM 53-00-50-2R-1 PARA 3B<BR>REMOVED ALL DAMAGE NOTED AND CLEANED REPAIR AREAS IASDR SWAA2022081826582Floor Panel · pulledFWD FLOOR PANEL 221DF UPPER SURFACE HAS AREAS OF PULLED STRANDS. / REMOVED AN APPROX. 19'X9' AREA OF DAMAGED TOOLSIDE PLY DAMAGE LOCATED 10' FROM THE OUTBOARD EDGE AND 14' FROM THE FORWARD EDGE WITH NO DISBOND; EXPOSED CORE CELLS OR CONTAMINATION NOTED; ALSO RSDR SWAA2022081826581Floor Panel · pulledFWD FLOOR PANEL 221CF UPPER SURFACE HAS AREAS OF PULLED STRANDS. / [01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 6 TABLE 6.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F.<BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-SDR SWAA2022080426743Floor Panel · brokenBROKEN FLOOR PANEL 221BF AT FWD GALLEY AREA 2022-398192 / [01] TOOL USED: CALIPER P/N: 500-197-30 S/N: 15120589 DUE DATE: 28-NOV-2022;[02] REPLACED AND INSTALLED SERVICEABLE FLOOR PANEL 221BF AT FWD GALLEY AREA I.A.W B737-700 AMM 53-21-00-400-801.SEE INDIVIDUASDR SWAA2022080426744Floor Panel · brokenBROKEN FLOOR PANEL 242TF AT AFT GALLEY AND LAV REPAIRED FLOOR PANEL 242TF AT AFT GALLEY AND LAV IAW B737-700 SRM 53-00-50-2R-1 REPAIR 1. SEE INDIVIDUAL SIGNOFFS BELOW.;[09] REPAIRED FLOOR PANEL 242TF AT AFT GALLEY AND LAV IAW B737-700 SRM 53-00-50-2R-1 REPAIR SDR DALA2022070804787Support Angle · corrodedSHIP 664 CORROSION ON ANGLE SUPPORT LBL 19 STA 740 AT STRINGERS FWD CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00409- ANGLE SUPPORT LBL 19 STA 740 AT STRINGERS FWD CARGO COMPARTMENT WAS REPLACED PER DWG 453N1853 REV.G AND B757-200 SRM. (2309892)SDR DALA2022070804786Stringer · corrodedSHIP 664 CORROSION ON FLOOR STRINGER LBL 10.45 BTW STA 780 TO 740 FWD CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00406-FLOOR STRINGER LBL 10.45 BTW STA 700 TO 810 FWD CARGO COMPARTMENT WAS REPAIRED PER B757-200 SRM. (2309887)SDR DALA2022070804784Stringer · corrodedSHIP 664 CORROSION ON FLOOR STRINGER LBL 16.10 BTW STA 740 TO 760. CORRECTIVE ACTION: SUMMARY OF NRC 00405-FLOOR STRINGER LBL 16.10 BTW STA 700 TO 770 WAS REPAIRED PER B757-200 SRM. (2309874)SDR DALA2022070804760None · noneSHIP 3229 CORROSION FLOOR BEAM +Y254 FR 16 TO FR 17 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-72-11 AND 51-72-11. (2310614)SDR DALA2022070804759None · noneSHIP 3229 CORROSION FLOOR BEAM BETWEEN Y 1292 TO Y 1162 FR 66 TO FR 68 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-42-11 AND 51-72-11. (2310611)SDR SWAA2022081226111Floor Panel · debondedFLOOR PANEL 242UF DRAIN FITTINGS ARE DISBONDED. (MARKED) / [01] DRAIN FITTINGS FOR FLOOR PANEL 242UF WILL BE INSTALLED WITH PANEL INSTALLATION.;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2022081126114Floor Panel · pulledFLOOR PANEL 241NF HAS A PULLED-THROUGH INSERT AT FWD EDGE. (MARKED) / [01] IDENTIFIED FLOOR PANEL 241NF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 5 TABLE 5<BR><BR>DUE TO EXTENT OF DAMAGE NEW FLOOR BOARD WILL BE FABRICATED IAW SRM 53-00-50-2R-0 PAR.1 A(NOTE) <BR><BSDR SWAA2022081026101Floor Panel · brokenFLOOR PANEL 242XF IS BROKEN. / [01] IDENTIFIED PANEL 242XF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 6 TABLE 6. FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F. DAMAGE TO BE REPAIRED IAW SRM 53-00-50-2R-1.<BR>REMOVED DAMAGED SKIN; REMOVEDSDR SWAA2022072926437Floor Panel · crackedCRACK FLOOR PANEL 120BF AT FWD CARGO COMPARTMENT 2022-383747 / [01] REPLACED FLOOR PANEL 120BF AT FWD CARGO COMPARTMENT IAW B737-700 SRM 53-00-53-1A-1 PARAGRAPH 5.A.(1)(A) 2) DUE TO CRACK IS COMMON TO HOLE. MEASURE OF CRACK IS: 0.730? TOOL USED DIGITAL CALIPERSDR SWAA2022072726084Floor Panel · delaminatedFLOOR PANEL 241AF UPPER SURFACE IS DELAMINATED. / [01] FABRICATED NEW 241AF FLOOR PANEL FROM BMS4-23 TYPE 2 LOT#1488929-1 USING BMS5-107 LOT#AK0KP9324K IAW SRM 53-00-50-2R-0 PARA 1A(NOTE) TABLE 204 AND DWG 144A5810-127<BR><BR>USED THERMOMETER ATS2208 CAL DUE DSDR DALA2022070804777Support · corrodedSHIP 664 CORROSION ON SUPPORT BTW 680 TO 700 AT LBL 16.10-LBL 10.45 FWD CARGO COMPARTMENT. CORRECTIVE ACTION: SUMMARY OF NRC 00621 SUPPORT BTW 680 TO 700 AT LBL 16.10-LBL 10.45 FWD CARGO COMPARTMENT WAS REPLACED PER B757 -200 SRM. (2306985)SDR SWAA2022081025447Floor Panel · debondedPANEL 222BF UPPER SURFACE IS DISBONDED / [01] IDENTIFIED PANEL 222BF IAW SRM 53-00-50-0I-1 TABEL 2 FIG 2. DAMAGE IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PARA 4B<BR><BR>DAMAGE WILL BE REPAIRED IAW SRM 53-00-50-2R-1<BR><BR>REMOVED ALL INSERTS TO SDR R61A2022072700474Upper Sheet · corrodedCF IIICABIN FLOOR UPPER SHEET AT FR 85 RH TO 86 RH, RBL 9 CORRODED. R&R IAW SRM 51-41-01 & 51-43-01.SDR R61A2022072600468Gusset · corrodedCF III FLOOR GUSSET PLATE AT RH FR 90, RBL 9. R&R IAW SRM 51-41-02.SDR R61A2022072600467Gusset · corrodedCF III FLOOR GUSSET PLATE AT RH FR 90, RBL 9. R&R IAW SRM 51-41-02.SDR R61A2022072600466Shear Panel · corrodedCF III FLOOR LH O/B SHEAR PNL AT FR 87 & 88 CORRODED. R&R IAW SRM 51-42-01, 51-41-02 & 51-43-01.SDR R61A2022072600465Shear Panel · corrodedCF III FLOOR CENTER SHEAR PNL AT FR 87 & 88 CORRODED. R&R IAW SRM 51-42-61.SDR R61A2022072600462Upper Sheet · corrodedCF III FLOOR SUPPORT LH UPPER SHEET AT FR 85 & 86, LBL 9 CORRODED. R&R IAW SRM 51-41-01 & 51-43-03.SDR DALA2022070704749None · noneSHIP 177 CORROSION FOUND ON AFT CARGO FLOOR BEAM AT STA 1219 RBL24, CORRECITVE ACTION: REPAIR THE AREA AS PER B767-300 SRM 53-00. (2304451)SDR DALA2022070704743None · noneSHIP 177 NUT PLATE HOLE CORROSION FOUND ON THE CABIN FLOOR BEAM LOWER CHORD AT STA1502.LBL52. CORRECITVE ACTION: THE CORRODED NUT PLATE HOLE REPAIRED AND ACCOMPLISHED AS PER PRI 600051-14. (2303988)SDR FDEA202207031676Floor Panel · delaminatedMAIN DECK- MCD ENTRY AREA- STA 695 LBL 100 FLOOR BOARD IS SPONGY. FABRICATED NEW FLOOR PANEL AT STA 695 LBL 100 (231LF) PER FEDEX DRAWING SRZ-25-005.SDR IPXA2023051319370Floorboard · damagedMAIN CARGO COMPARTMENT FLOOR PANEL REPAIR (SREO) 2 DENTS, 1WX 2.25LX .5D, AND .7***SM13/LMX8*** INSTALLED NEW FLOOR PANEL IAW AMM 53-01-06SDR FDEA202207011645Floor Panel · crackedMAIN DECK CARGO FLOOR PANEL P/N:152W8452-21 FOUND CRACKED AT STA1350 LBL45. REPAIRED MAIN DECK CARGO FLOOR PANEL P/N:152W8452-21 CRACKED AT STA 1350 LBL45. AS PER B777 SRM 53-00-50-2R REPAIR 1 REV 41.0 REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.SDR R61A2022072000456Panel · corrodedWHILE AC WAS IN FOR HVY CK FOUND FWD SECTION INTERNAL FUSE CORROSION FOUND ON SILL PANEL RH SIDE OF FLOOR BTWN FR12-14. REPLACED SILL PN 170-05663-005 IAW SRM 51-41-02.51-43-02 .AC WAS RETURNED TO SERVICE.SDR R61A2022072000455Support Angle · corrodedWHILE AC WAS IN FOR HVY CK FOUND CF3 RH FLOOR BOARD SUPPORT ANGLE AT FR 87 FOUND CORRODED. REPLACED SUPPORT PN 170-66797-001 IAW SRM 51-41-01.AC WAS RETURNED TO SERVICE.SDR R61A2022071500435Floor Support · corrodedCNTR FUSE III R/H FLOOR BOARD SUPP ANGLE AT FR 87 CORRODED. R&R IAW SRM 51-41-01.SDR R61A2022071500433Floor Support · corrodedCNTR FUSE III R/H FLOOR SUPPORT AT FR 88-90 CORRODED. R&R IAW SRM 51-43-01 & 51-42-01.
Back to JASC 5321