JASC 5321
Service difficulty reports · 49,369
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR FDEA201703120857Floor Panel · delaminatedFWD CARGO-COMPT FLOOR PNL 131RF, PNL SOFT, DELAMINATED. FWD CARGO COMPT FLR PNL 131RF FABRICATED ON T17/1262667 PER SRZ 25-005, CAT "A" MAJOR REPAIR.SDR FDEA201703120856Floor Panel · brokenFWD CARGO-COMPT FLOOR PNL 132QF, SEVERAL EDGE AREAS BROKEN, HONEYCOMB EXPOSED. FWD CARGO COMPT FLOOR PANEL 132QF FABRICATED ON T17/1262665 PER SRZ25-005, CAT 'A' MAJOR REPAIR.SDR AALA201703139032Floor Panel · delaminatedDELAMINATION ON AFT CARGO ENTRY FLOOR PANEL, JUST FORWARD OF CARGO OPENING. APPROXIMATELY 24 INCHES BY 50 INCHES. MAINTENANCE REPLACED FLOOR PANEL 151VG PER AMM 53-42-14. AIRCRAFT WAS GROUNDED.SDR AALA201703139031Floor Panel · delaminatedDELAMINATION ON AFT CARGO FLOOR BOARD AT CARGO DOOR ENTRY WAY. ENTRY WAY IS DELAMINATED APPROXIMATELY 24 INCHES BY 48 INCHES. MAINTENANCE REPLACED FLOOR PANEL 151ZG PER AMM 53-42-14. AIRCRAFT WAS GROUNDED.SDR IPXA2017032315434Floor Panel · brokenINSPECTION TYPE: SEG4, MAIN DECK FLOOR PANEL 242XKF IS BROKEN. FABRICATED A NEW FLOOR PANEL IAW SREO B757-5320-9692.SDR AALA201703139026Floor Panel · corrodedAIRCRAFT IN BASE MAINTENANCE. CORROSION ON FORWARD CABIN FLOOR PANEL 222FF (PANEL RACK). REPLACED FLOOR PANEL 222FF PER 51-72-11.SDR FDEA201703110853Floor Panel · crackedMAIN CARGO FLOOR PANEL 251BJ HAS CRACK FABRICATED FLOOR PANEL 251BJ ON T17/1262296 IAW SRZ-25-005. CLASSIFIED AS CAT "A" MAJOR REPAIR.SDR FDEA201703110852Floor Panel · crackedMAIN CARGO FLOOR PANEL 252NH HAS CRACKED EDGE FABRICATED FLOOR PANEL 252NH ON T17/1262298 IAW SRZ-25-005. CLASSIFIED CAT "A" MAJOR REPAIR.SDR FDEA201703110851Floor Panel · crackedMAIN CABIN FLOOR PANEL 252BJ HAS CRACK. FABRICATED FLOOR PANEL 252BJ ON T17/1262268 IAW SRZ-25-005 CLASSIFIED AS CAT "A" MAJOR REPAIR.SDR AALA201703139025Floor Panel · debondedDEBONDED FORWARD CABIN FLOOR PANEL 221FF). REPLACED THE FLOOR PANEL IAW SRM 51-72-11.SDR AALA201703319051Floor Panel · delaminatedDELAMINATION FOUND ON THE AFT CARGO BAY FLOOR PANEL 151FF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00, AND IRM 9701, REVISION G.SDR AALA201703319049Floor Panel · crackedA CRACK WAS ON THE FORWARD FWD CARGO BAY FLOOR PANEL 131EF. REPLACED THE FLOOR PANEL IAW SRM 53-02-00, AND IRM 9701 REVISION G.SDR IPXA2017031415139Floor Panel · brokenINSPECTION TYPE: 1C, MAIN CABIN FLOOR PANEL 261DM IS BROKEN. FABRICATED A NEW FLOOR PANEL IAW SREO A300-5320-40552.SDR DALA2017031301980Floor Panel · damagedAFT CARGO FLOOR PANELS 151LF FOUND DAMAGE. FABRICATED NEW FLOOR PANELS IAW DWG 453W5210.SDR FDEA201703100847Floor Panel · crackedMAIN CARGO FLOOR PANEL 231AH HAS CRACK. FABRICATED FLOOR PANEL 231AH ON T17/1262292 IAW SRZ-25-005. CLASSIFIED AS CAT "A" MAJOR REPAIR.SDR FDEA201703100846Floor Panel · crackedMAIN CARGO FLOOR PANEL 241EF HAS CRACK. FABRICATED FLOOR PANEL 241EF ON T17/1262291 IAW SRZ-25-005. CLASSIFIED AS CAT "A" MAJOR REPAIR.SDR FDEA201703100845Floor Panel · crackedMAIN CARGO FLOOR PANEL 242VH HAS CRACK. FABRICATED FLOOR PANEL 242VH ON T17/1262294 IAW SRZ-25-005. CLASSIFIED AS CAT "A" MAJOR REPAIR.SDR IPXA2017031415103Roller Tray · corrodedINSPECTION TYPE: C11, CORROSION ON AFT CARGO ROLLER TRAY AT BS 1197 + 44 TO 1197 + 132, RBL 6.5. REPLACED THE ROLLER TRAY.SDR IPXA2017031415102Roller Tray · corrodedINSPECTION TYPE: C11, CORROSION ON AFTER CARGO ROLLER TRAY AT BS 1197 + 44 TO 1197 + 132, RBL 20. REPLACED THE ROLLER TRAY.SDR AALA201703149007Floor Panel · damagedPASSENGER CABIN FLOOR PANEL SOFT OR DAMAGED.SDR IPXA2017031415130Floorboard · damagedINSPECTION TYPE: SEG2, MAIN DECK FLOORBOARD 242XJK DAMAGED, FABRICATED A NEW FLOORBOARD 242XJF IAW SREO 757-5320-9692-J.SDR IPXA2017031615215Floor Panel · delaminatedINSPECTION TYPE: SEG2, MAIN DECK FLOOR PANEL 231XJF DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW SREO 757-5320-9692-J.SDR IPXA2017031615214Floorboard · delaminatedINSPECTION TYPE: SEG2, MAIN DECK FLOORBOARD 231XFF DELAMINATED. FABRICATED A NEW FLOORBOARD IAW SREO 757-5320-9692-J.SDR IPXA2017031415131Floor Panel · damagedINSPECTION TYPE: SEG2, MAIN DECK FLOOR PANEL 241XEF DAMAGED. FABRICATED A NEW FLOOR PANEL IAW SREO 757-5320-9692-J.SDR IPXA2017031415128Floorboard · damagedINSPECTION TYPE: SEG2, MAIN DECK FLOORBOARD 241XHF DAMAGED. FABRICATED A NEW FLOORBOARD IAW SREO B757-5320-9692-J.SDR IPXA2017031014962Floor Panel · brokenINSPECTION TYPE: 1C, MAIN CABIN FLOOR PANEL 252BN IS BROKEN. FABRICATED A NEW FLOOR PANEL IAW SREO A300-5320-40552.SDR IPXA2017031014960Floor Panel · damagedINSPECTION TYPE: 1C, MAIN CABIN FLOOR PANEL 231MJ HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SREO A300-5320-40552.SDR IPXA2017031014958Floor Panel · puncturedINSPECTION TYPE: 1C, MAIN CABIN FLOOR PANEL 252UJ PUNCTURED. FABRICATED A NEW FLOOR PANEL IAW SREO A300-5320-40552.SDR IPXA2017031014957Floor Panel · brokenINSPECTION TYPE: 1C, MAIN CABIN FLOOR PANEL 252JF IS BROKEN. FABRICATED A NEW FLOOR PANEL IAW SREO A300-5320-40552.SDR IPXA2017031014956Floor Panel · brokenINSPECTION TYPE: 1C, MAIN CABIN FLOOR PANEL 231KJ IS BROKEN. FABRICATED A NEW FLOOR PANEL IAW SREO A300-5320-40552.SDR IPXA2017031014955Floor Panel · brokenINSPECTION TYPE: 1C, MAIN CABIN FLOOR PANEL 231TG IS BROKEN. FABRICATED A NEW FLOOR PANEL IAW SREO A300-5320-40552.SDR ASAA2017030720086Floor Panel · corrodedAFT PIT FLOOR PANEL 140EF HAS MINOR CORROSION ALONG EDGE. GROUNDED - YES. EVALUATED DAMAGE ON AFT PIT FLOOR PANEL 140EF, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53. FABRICATED NEW 140EF P/N 453A2610-58 IAW DWG 453A2610 REV K AND GPM 05-00-85 4.A.2.SDR IPXA2017031615239Floor Panel · debondedFORWARD CARGO BAY FLOOR PANEL 131RG HAD SEVERAL AREAS OF DISBONDMENT. REPAIRED IAW EO A300-5320-42721-F.SDR ASAA2017030620087Floor Panel · corrodedFWD PIT FLOOR PANEL 120CF HAS MINOR CORROSION ALONG EDGE. GROUNDED - YES. FABRICATED/REPLACED CARGO FLOOR PANEL 120CF IAW DRAWING 453A1610 REV T/D. ALODINED AND PRIMED IAW SOPM 20-43-03 AND BOEING SOPM 20-41-02 AND IAW GPM 05-00-85 4.A.2.SDR ASAA2017030620085Floor Panel · corrodedAFT PIT FLOOR PANEL 140AF HAS MINOR CORROSION ALONG EDGE. GROUNDED - YES. CLEANED PANEL 140AF IAW SOPM 20-30-80. PANEL FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53. FABRICATED NEW PANEL IAW BAC DWG 453A2610 REV E. ALODINED AND PRIMED PANEL IAW SRM 51-20-01 AND ISDR ASAA2017030620084Floor Panel · corrodedFWD PIT FLOOR PANEL 120BF HAS MINOR CORROSION ALONG EDGE. GROUNDED - YES. FABRICATED FWD PIT PANEL 120BF PER DWG 453A1610 REV T. ALODINED AND PRIMED PER DWG 453A1610 REV T.SDR ASAA2017030620083Floor Panel · corrodedAFT PIT FLOOR PANEL 140CF HAS MINOR CORROSION ALONG EDGE. GROUNDED - YES. FABRICATED NEW PANEL IAW BAC DWG 453A2610. APPLIED FINISHES IAW SRM 51-20-01. AUTHORITY TO FAB CARGO FLOOR PANELS IAW GPM 05-00-85 4.A.2.SDR ASAA2017030620082Floor Panel · corrodedFWD PIT FLOOR PANEL HAS MINOR CORROSION ALONG EDGE 120AF. GROUNDED - YES. PANEL 120AF SCRATCHES MORE THAN 3" OUT OF LIMITS IAW SRM 53-00-53. FABRICATED, ALODINED AND PRIMED PANEL 120AF IAW DWG 453A1610 AND SOPM 20-41-01.SDR AALA201703089027Floor Panel · damagedAIRCRAFT WAS NOT GROUNDED. FORWARD CARGO COMPARTMENT FLOOR PANEL 131HF HAS A TOPSKIN SPLIT, FRAME 30-34 APPROXIMATELY 12 FROM PANEL EDGE. REPAIRED IAW AMM 25-50-00. OPERATIONAL CHECK GOOD.SDR ASAA2017030620070Floor Panel · corrodedFWD CARGO, FLOOR PANEL 120DF HAS MINOR CORROSION ALONG EDGE. ACFT GROUNDED. FABRICATED A NEW FLOOR PANEL AND APPLIED PROTECTIVE FINISHES IAW DWG 453A1610, REV T, AND GPM 05-00-85 4.A.2.SDR ASAA2017030520153Floor Panel · corrodedFWD CARGO BAY FLOOR PANEL 120AF IS CORRODED ON FWD EDGE. ACFT GROUNDED. FABRICATED A NEW FWD CARGO FLOOR PANEL IAW SRM 51-40-05-0G-1, AND 51-20-01-0G-0.SDR ASAA2017030520152Floor Panel · gougedFWD CARGO BAY FLOOR PANEL 120CF HAS A DEEP GOUGE. ACFT GROUNDED. REPAIRED THE FLOOR PANEL IAW SRM 51-70-13-2R-1.SDR ASAA2017030520093Floor Panel · corrodedAFT CARGO COMPARTMENT FLOOR PANEL 140DF CORRODED ALONG EDGE. GROUNDED - YES. FABRICATED, LOCATED AND DRILLED NEW PANEL IAW SRM 51-40-05-0G-0 W 1IN O .071 R .030 L 61IN. D .040.SDR ASAA2017030520092Floor Panel · corrodedAFT CARGO COMPARTMENT FLOOR PANEL 140AF CORRODED ALONG FWD END. GROUNDED - YES. MEASURED CORR LENGTH, FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1, FABRICATED FLOOR PANEL IAW SRM 51 40 05 0G 0, RESTORED FINISH IAW AMM 51-00-58-201 AND BSOPM 20 41 02 W .75 OSDR AALA201704039020Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE. DELAMINATION ON PASSENGER CABIN FLOOR PANEL 241MF (TOP LAYER). REPLACED FLOOR PANEL 241MF PER SRM 53-02-00 AND IRM 9701 REVISION G.SDR AALA201703209001Floor Panel · delaminatedDELAMINATED TOP LAYER OF FLOOR PANEL 251PF IN PASSENGER CABIN. REPLACED THE FLOOR PANEL IAW SRM 53-02-00, AND IRM 9701 REVISION G.SDR AALA201703049003Floor Panel · delaminatedDELAMINATION ON MID CABIN FLOOR PANEL 252BG. REPLACED THE FLOOR PANEL IAW AMM 53-42-12.SDR FDEA201703030757Floor Panel · crackedCOURIER AREA FLOOR PANEL 221PF IS CRACK ON TOP LAYER. FABRICATED A NEW FLOOR PANEL IAW DWG SRZ-25-005. MAJOR RAPAIR.SDR SWIA201743209Floor Panel · corrodedFIVE LOCATIONS ON THE LH PRESSURE FLOOR PANEL CORRODED. REPAIRED THE PRESSURE FLOOR PANEL IAW REO.SDR FDEA201703020752Floor Panel · damagedFLOOR PANEL 131ZF IN THE FWD CARGO BAY HAS EDGE DAMAGE. FABRICATED A NEW FLOOR PANEL IAW SRZ 25-005. MAJOR REPAIR.
Back to JASC 5321