SDR RRXA001666Floorbeam · misdrilledDURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES, FABRICATED Feb 21, 2000 · N994CF · Doug DC862SDR RRXA003396Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE MAIN DECK FLOOR BOARD BETWEEN STA'S 1200 TO 1220 AND X32 Z=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53Feb 18, 2000 · N831AL · Doug DC873FSDR RRXA000519Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOOR PANEL BETWEEN STA 1580 TO STA 1680 AND BL 26 RIGHT. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FOUND TO BE IN LIMITS IAW DC-8 SRM 53-2-0 FIGURE 1. CORROSION DAMAGE RECORDED IN EWA CORROSION PFeb 17, 2000 · N831AL · Doug DC873FSDR CA000215026Floorboard · corroded(CAN) FLOOR HONEYCOMB CORRODED IN PANELS DIRECTLY UNDER THE DOWN RING ASSY AND TIE DOWN STUD. CORROSION IS ONLY APPARENT VISUALLY ON BOTTOM SIDE OF PANELS WHEN FILLER ASSY P/N 205-031-257-074 IS REMOVED.Feb 11, 2000 · Bell 212SDR DHL200080389CFloorboard · deterioratedAT C-CHECK, FWD LOWER CARGO NR 3 FLOOR DETERIORATED FROM FS 260 TO 280. REMOVED FLOOR PANEL AND FASTENERS IAW SRM 51-3-0 PAGE 1, 2, 3. FABRICATED FLOOR PANEL IAW SRM 53-11-3 PAGE 4C. CLEANED, TREATED AND PRIMED IAW SRM 51-1-21 PAGE 11 & 12. INSTALLED FLOORFeb 11, 2000 · N803DH · Doug DC873FSDR DHL200080389Floorboard · deterioratedFWD LOWER CARGO NR 3 FLOOR DETERIORATED FROM FS 260 TO 280. REMOVED FLOOR PANEL AND FASTENERS IAW SRM 51-3-0 PAGE 1, 2, 3. FABRICATED FLOOR PANEL IAW SRM 53-11-3 PAGE 4C. CLEANED, TREATED AND PRIMED IAW SRM 51-1-21 PAGE 11 & 12. INSTALLED FLOOR PANELS WITHFeb 11, 2000 · N803DH · Doug DC873FSDR RRXA002933Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL AT STA 1300 AND X-47, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-2. (CORROSION DAMAGE RECFeb 7, 2000 · N792FT · Doug DC873FSDR RRXA002960Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AND X-24 & X-44, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORRFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002947Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 740 - 760 AND X-+59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSIONFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002943Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AND X-59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21. (CORROSIONFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002942Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AT X-44, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002941Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DAMAGE REFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002940Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 720, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DAMAGE REFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002939Splice · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FINGER SPLICES ON THE FLOOR PLANK BETWEEN STA 580 - 880 AND X-24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002938Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 1680 AND X-+24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4. (CORROSION DAMAGE REFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002937Splice · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FINGER SPLICE ON THE FLOOR PLANK BETWEEN STA 580 - 720 AND X-+24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002935Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 720 AND AT X-+24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (CORROSFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002931Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 580 - 880, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DAMAGE RECORDEFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002930Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FINGER SPLICES ON THE FLOOR PLANK AT STA 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSIOFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002929Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DAMAGE RECORDED IN EFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002928Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 & 880 AT X-24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002927Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 & 880 AT X-24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002926Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 & 720 AT X-59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002925Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 & 720 AT X-+59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21. (CORROSIONFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002923Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4. (CORROSION DAMAGE RECORDED IN EFeb 4, 2000 · N792FT · Doug DC873FSDR RRXA002922Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL AT STA 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21. (CORROSION DAMAGE RECORDED IN Feb 4, 2000 · N792FT · Doug DC873FSDR RRXA002921Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21. (CORROSION DAMAGE RECORDED IN Feb 4, 2000 · N792FT · Doug DC873FSDR RRXA002920Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMGE TO THE FLOOR PLANK AT STA 800 AND X-24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4. (CORROSION DAMAGE RECORFeb 4, 2000 · N792FT · Doug DC873FSDR 20000503SH032Floorboard · crackedREPAIR OF CRACK IN CABIN FLOOR BOARD AT BS 237 TO BS 503, LBL 39 (EIA ECRA 940-53-028-2). (X)Feb 4, 2000 · N940F · Doug DC933FSDR 20000503SH031Floorboard · crackedREPAIRS TO FLOOR PANEL FOR DENTS AND CRACKS FROM BS 237 TO BS 484, BL ZERO TO RBL 14 PER EIA ECRA 940-53-049-2. (X)Feb 4, 2000 · N940F · Doug DC933FSDR RRXA002946Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AT X-59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-8. (CORROSION DFeb 3, 2000 · N792FT · Doug DC873FSDR RRXA002945Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AT X-59, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0. (CORROSION DFeb 3, 2000 · N792FT · Doug DC873FSDR RRXA002944Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK BETWEEN STA 580 - 880 AT X-44.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4. (CORROSIONFeb 3, 2000 · N792FT · Doug DC873FSDR UPS00831702Floor Panel · corrodedINSPECTION TYPE:C123 STATION 350 BL 29L FLOOR PANEL HAS CORROSION. REPLACED SECTION OF FLOORBOARD IAW DC8 SRM 51-3-0.Feb 1, 2000 · N752UP · Doug DC871FSDR RAIA0001032Floor Panel · corrodedMX- DURING INSPECTION FOUND CORROSION AT FRAME 35-36 FLOOR WEB, RIGHT OUTBOARD SIDE. MAINTENANCE REPLACED RIGHT OUTBOARD FLOOR WEB BETWEEN FRAMES 35 AND 36 IAW ATR42 SRM.Jan 30, 2000 · N422TE · Aerosp ATR42300SDR RRXA002959Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PANEL AT STA 40, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-4. (CORROSION DAMAGE RECORDED IN EWJan 29, 2000 · N792FT · Doug DC873FSDR CALA0000098Floor Panel · crackedINSPECTION FOUND A .5 INCH CRACK IN FLIGHT DECK FLOOR PANEL AT ENTRYWAY AREA, STA 297, LBL17. THE FLOOR PANEL WAS REPAIRED IAW BOEING DRAWING 141N5810 AND ECRA 5321-01080.Jan 27, 2000 · N14114 · Boeing 757224SDR DHL200080392CFloorboard · crackedAT C-CHECK, FWD GALLEY NR 684 FLOOR INTERNAL SKIN CRACKED 2 INCHES AT STA 50.00 RT. PERFORMED STOP DRILL ON AFFECTED AREA IAW SRM 53-2-0 PAGE 2C, PERFORMED ANTI-CORROSION TREATMENT IAW SRM 51-1-A PAGE 11 & 12. FABRICATED DOUBLER, TREATED THEN INSTALLED WITH Jan 22, 2000 · N803DH · Doug DC873FSDR DHL200080392Floorboard · crackedFWD GALLEY NR 684 FLOOR INTERNAL SKIN CRACKED 2 INCHES AT STA 50.00 RT. PERFORMED STOP DRILL ON AFFECTED AREA IAW SRM 53-2-0 PAGE 2C, PERFORMED ANTI-CORROSION TREATMENT IAW SRM 51-1-A PAGE 11 & 12. FABRICATED DOUBLER, TREATED THEN INSTALLED WITH SOLID RIVETSJan 22, 2000 · N803DH · Doug DC873FSDR DHL200080388CFloorboard · crackedAT C-CHECK, FWD GALLEY NR 684 FLOOR INTERNAL SKIN CRACKED 2 INCHES AT STA 50.00 RT. PERFORMED STOP DRILL ON AFFECTED AREA IAW SRM 53-2-0 PAGE 2C, PERFORMED ANTI-CORROSION TREATMENT IAW SRM 51-1-A PAGE 11 & 12. FABRICATED DOUBLER, TREATED THEN INSTALLED WITH Jan 22, 2000 · N803DH · Doug DC873FSDR TWAA0001605Floor Panel · corrodedDURING OP 16 MAINT CHECK FOUND CABIN FLOOR PANEL 71 CORRODED. MADE NEW FLOOR PANEL PER SSRM 53-00-104 PAGE 201.Jan 21, 2000 · N989Z · Doug DC931SDR DHL200080313CFloor Panel · crackedAT C-CHECK, MAIN CARGO FLOOR SKIN BROKEN AT STA 690.00 BETWEEN TRACK 2LM AND TRACK 3LT. REMOVED DAMAGED AREA AND FABRICATED DOUBLER IAW SRM 53-2-3 PG 39-40 FIG 10. TREATED AND PRIMED IAW SRM 51-1-8 PG 11-12. INSTALLED DOUBLER WITH SOLID RIVETS IAW SRM 51-1-Jan 19, 2000 · N803DH · Doug DC873FSDR TWAA0001406Floor Panel · corrodedDURING OP 16 MAINT CHECK, FOUND CABIN FLOOR PANEL 23 HAD CORROSION. FABRICATED NEW FLOOR PANEL PER SRRM 53-00-104, PAGE 201.Jan 19, 2000 · N925L · Doug DC932SDR RRXA002958Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 67 AND X+40, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-20D. (CORROSION DAMAGE RECJan 18, 2000 · N792FT · Doug DC873FSDR RRXA000066Floor Board · damagedDURING A MAINTENANCE VISIT FOUND SCREWS PULLING THROUGH, FUSELAGE, UPPER CARGO COMPT AT STA 1230 - XCW 16.5 RT SCREW PULLING THROUGH FLOORBOARD. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.Jan 18, 2000 · N792FT · Doug DC873FSDR RRXA000065Floor Board · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, UPPER CARGO COMPT AT STA 1678.5 TO STA 1698.5 XCW 24.5 - 59..5 FLOORBOARD PANEL HAS MISDRILLED HOLES. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.Jan 18, 2000 · N792FT · Doug DC873FSDR RRXA000064Floor Board · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, UPPER CARGO COMP AT STA 1698.5 TO STA 1725 XCW 10.5 - 59.5. RT FLOORBOARD PANEL MISDRILLED HOLES AND WORN. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.Jan 18, 2000 · N792FT · Doug DC873FSDR RRXA000063Floor Board · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, UPPER CARGO COMPT STA 1727.5 TO STA 1746 XCW 0 - 58 RT PANEL SEPARATED, WORN AND MISDRILLED HOLES FLOORBOARD. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.Jan 18, 2000 · N792FT · Doug DC873FSDR RRXA000062Floor Board · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, UPPER CARGO COMPT AT STA 1746 TO STA 1766, PANEL WEAK AND SEVERAL MISDRILLED HOLES XCW 0-35.5 RT FLOORBOARD. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.Jan 18, 2000 · N792FT · Doug DC873FSDR RRXA000061Floor Board · damagedDURING A MAINTENANCE VISIT FOUND HOLD DAMAGE; FUSELAGE, UPPER CARGO COMPT AT FS 1678.5 - 1698.5 - XCW 24.5 TO 59.5 PANEL HAS HOLE AND AREAS OF WEAR, FLOORBOARD. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.Jan 18, 2000 · N792FT · Doug DC873F
Back to JASC 5321