JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR RRXA000060Floor Board · misdrilledDURING A MAINTENANCE VISIT FOUND CRUSHED AND MISDRILLED HOLES, FUSELAGE, FLOORBOARD, UPPER CARGO COMPT FS 1698.5 - 1725 - XCW 10.5 TO 59.5, PANEL SEPARATED. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM.. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000059Floor Board · misdrilledDURING A MAINTENANCE VISIT FOUND CRUSHED AND SEVERAL MISDRILLED HOLES, FUSELAGE, UPPER CARGO COMPT FS 1727.5 - 1746 - XCW -0 TO 58 LT FLOORBOARD (WORN, CRUSHED AND MISDRILLED HOLES). DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8SDR RRXA000058Floor Board · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, UPPER CARGO COMPT FS 1746 - 1766 LT FLOORBOARD WEAK AND SEVERAL MISDRILLED HOLES XCW -0 TO 34.5. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR TWAA0001413Floor Panel · corrodedDURING OP 16 MAINT CHECK, FOUND CABIN FLOOR PANEL MEMBER NUMBER 12 HAD CORROSION ON IT. REF CPCP TASK C46-53306 FWD GALLEY AREA. REMOVED CORROSION PER SPM 51-10-3 AND TREATED.SDR GAIA0035Floorboard · damagedDURING C-CHECK INSPECTION, FOUDN THE FLOORBOARD DAMAGED AT FUSELAGE STATION 332 BL 22R. THE FLOORBOARD WAS REPAIRED IAW THE DC-9 SRM. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GAIA0034Floorboard · damagedDURING C-CHECK INSPECTION, FOUND THE FLOORBOARD DAMAGED AT FUSELAGE STATION 424 BL 6R AND 10R. THE FLOORBOARD WAS REPAIRED IAW THE DC-9 SRM. THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GAIA0033Floorboard · damagedDURING C-CHECK INSPECTION, FOUND THE FLOORBOARD DAMAGED AT FUSELAGE STATION 339 BL 5. THE FLOORBOARD WAS REPAIRED IAW THE DC-9 SRM THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR GAIA0028Floor Panel · gougedDURING C-CHECK INSPECTION, FOUND A GOUGE THROUGH THE FLOOR PANEL AT STATION 170. A NEW FLOOR PANEL WAS FABRICATED IAW THE DC-9 SRM THE AIRCRAFT WAS RETURNED TO SERVICE. (M)SDR TWAA0001411Floor Panel · corrodedDURING OP 16 MAINT CHECK, FOUND CABIN FLOOR PANEL 35 HAD CORROSION. FABRICATED NEW FLOOR PANEL PER SSRM 53-00-104, PAGE 201.SDR TWAA0001409Floor Panel · crackedDURING OP 16 MAINT CHECK, FOUND CABIN FLOOR PANEL SCREW HOLES CRACKED IN SEVERAL PLACES, PANEL 48. FABRICATED NEW PANEL PER SSRM 53-00-104, PAGE 201.SDR TWAA0001408Floor Panel · damagedDURING OP 16 MAINT CHECK, FOUND CABIN FLOOR PANEL 77, HAD THE END OF THE PANEL BROKEN OUT. FABRICATED NEW PANEL PER SSRM 53-00-104, PAGE 201.SDR TWAA0001407Floor Panel · damagedDURING OP 16 MAINT CHECK, FOUND CABIN FLOOR PANEL 42 HAD BOTTOMSIDE IN CHANNEL. FABRICATED NEW PANEL PER SSRM 53-00-104, PAGE 201..SDR TWAA0001204Floor Panel · crackedDURING OP 16 MAINT CHECK, FLOOR PANEL NUMBER 61 HAD 2 EA CRACKED HAT SECTIONS AT AFT END. REMOVED 4 HAT SECTIONS AND REPLACED WITH 4 NEW HAT SECTIONS PER SSRM 53-00-104, A AND B.SDR AT0000028Floor Board · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND RIGHT SIDE CABIN FLOORBOARD CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED NEW FLOORBOARD IAW DC9 SRM 53-01 FIG 1, 51-10-03, 51-10-04, AND 51-30-02.SDR RRXA003377Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LAV FLOOR BOARDS AT FS 25-37 AND LBL18 TO RBL34, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PART IAW DC-8S RM 53-7-1 AND 51-1-2SDR RRXA000179Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 4 NUMEROUS DRILLED HOLES ON FLOOR PLANK (C9-R11). DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000178Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 5 NUMEROUS DRILLED HOLES ON FLOOR PANEL/PLANK. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000177Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 4 NUMEROUS DRILLED HOLES ON FLOOR PANEL/PLANK (C4-R7). DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000176Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FORM NR 84 ITEM NR 4 NUMEROUS DRILLED HOLES IN FLOOR PLANK/PANEL (C1-R4). DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000175Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 1 NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL/PLANK (O1-R6). DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000174Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 3 NUMEROUS DRILLED HOLES ON FLOOR PLANK/PANEL (C5-R9). DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000173Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 1 NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK (C5-R7). DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000172Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEMS NR 4 AND NR 5 12 FROM EDGE FLANGE DRILLED. ALSO NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK/PANEL (C1-R7). DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAWSDR RRXA000171Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM #84 ITEMS #1, #3, AND #5 NUMEROUS DRILLED HOLES THROUGH FLOOR PLANK/PANEL. ALSO LARGE HOLE WITH CRACK AT ABOUT CENTER OF FLOOR PLANK, ALSO LARGE DENT WITH CRACK ABOUT 2' FROM EDGE (C2-R13). DAMSDR RRXA000170Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 1 NUMEROUS DRILLED HOLES FLOOR PANEL (C12-R3). DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000168Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 1 NUMEROUS DRILLED HOLES ON FLOOR PLANK/PANEL (C9-R13). DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000167Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 1 NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL (C5-R2). DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000166Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 5 SCREW HOLE CRACKED 63-1/2 FROM EDGE AND 3 FROM OUTBOARD EDGE (C5-R4). DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000164Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84, ITEM NR 2 NUMEROUS DRILLED HOLES ON FLOOR PLANK (C1-R1). DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000163Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84, ITEM NR 4 & NR 5. WORN DRILLED HOLE AREAS ON FLOOR PLANK AND NUMEROUS DRILLED HOLES ON FLOOR PLANK (C12-R1). DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SDR RRXA000162Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84, ITEM NR 4, NUMEROUS DRILLED HOLES ON FLOOR PLANK/PANEL (C7-R1). DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000161Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM #84, ITEM #4, NUMEROUS HOLES THROUGHOUT FLOOR PLANK/PANEL. (C12-R11). DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA000160Floor Panel · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84, ITEM NR 1 NUMEROUS DRILLED HOLES IN FLOOR PLANK/PANEL. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8.SDR RRXA003376Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE MAIN DECK FLOOR BOARD 1688C, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21 AND DWG 5755032.SDR AT0100007Floorboard · corrodedFOUND CABIN CENTER FLOORBOARD AT BS 480 - 520 HAS NUMEROUS INSERTS CORRODED, CORNER OF PANEL BROKEN AND SKIN SPREADING. FABRICATED CABIN FLOORBOARD CENTER PANEL AT BS 480 - 520 IAW B737 SRM 53-20-1 AND -2 CMM 25-00-66.SDR RRXA002934Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR PLANK AT STA 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-1-21. (CORROSION DAMAGE RECORDED IN SDR RRXA002924Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMGE TO THE FLOOR PANEL BETWEEN STA 580 & 880 AT X-24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CORROSION DASDR MWEA00016Floorboard · crackedRIGHT SIDE CABIN FLOORBOARDS MARKED F4 AND E6 HAVE SEVERAL CRACKS NEAR THE ENDS. MTC FABRICATED AND INSTALLED DOUBLERS.SDR RRXA003369Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR BOARD AT FS 50 X+50 Z=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0, FIG 1F AND 53-2-0.SDR TWAA0001009Floor Panel · damagedDURING OP 16 MAINT CHECK, FOUND CABIN FLOOR PANEL NUMBER 40B WITH FIELD REPAIR. MADE NEW FLOOR PANEL PER TWA SSRM 53-00-104, PAGE 201.SDR TWAA0001008Floor Panel · corrodedDURING OP 16 MAINT CHECK, PANEL NUMBER 44 HAD GOUGES AT END OF TOP HATS AND CORROSION AT OPPOSITE END. FABRICATED NEW FLOOR PANEL PER SSRM 53-00-104, PAGE 201.SDR TWAA0001007Floor Panel · brokenDURING OP 16 MAINT CHECK, NUMBER 21 FLOOR PANEL CORNER WAS BROKEN. FABRICATED NEW PANEL PER SSRM 53-00-14, PAGE 201.SDR TWAA0001006Floor Panel · crackedDURING OP 16 MAINT CHECK, FOUND FLOOR PANEL 19 SUPPORT RIBS WERE CRACKED. FABRICATED NEW FLOOR PANEL PER SSRM 53-00-104, PAGE 201..SDR TWAA0001005Floor Panel · corrodedDURING OP 16 MAINT CHECK, FOUND CORROSION ON FLOOR PANELS 7, 8, 9, 10, 11, 29, AND 58. NEW FLOOR PANELS MADE PER TWA SSRM 53-00-104.SDR TWAA0000905Floor Web · corrodedDURING OP 16 MAINT CHECK, THE CABIN AFT SERVICE DOOR TOP OF FLOOR WEB WAS CORRODED AROUND AFT DOOR JAM AREA, TOP OF WEB AND UNDER WEB STA 1174. REPAIRED PER SRM 53-01, FIG 2, SRM 51-60-00 PAGE 27, AND SRM 51-30-02.SDR TWAA0000904Floor Web · crackedDURING OP 16 MAINT CHECK, FOUND COCKPIT FLOOR MEMBRANE CRACKED AT STA 159, RBL 8 TO 10 IN. ACCOMP EDDY CURRENT PER NDT MANUAL 51-00-03, PART 6. INSTALLED DOUBLER REPAIR PER SRM 53-01, FIG 2, PAGE 9.SDR RRXA002953Splice · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOOR SPLICE BETWEEN STA 280 - 340 AT X-48 AND Z-50, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3. (CSDR CALA9901725Floor Panel · corrodedINSPECTION FOUND BLUE WATER STAINS AND CORROSION ON FLOOR PANEL AT STA 290-300. THE PANEL WAS REMOVED AND A NEW PANEL WAS INSTALLED IAW SRM 51-10-4, PAGE 4, 51-10-2, AND MM 51-20-0.SDR MWEA99978Floor Board · corrodedFORWARD EDGE ON FLOORBOARD F2 IS MODERATELY CORRODED AT STATION 267. MAINTENANCE FABRICATED AND INSTALLED NEW FLOORBOARD.SDR MWEA99977Floor Board · corrodedFLOORBOARD E2 AT STATION 267, THE FORWARD EDGE IS MODERATELY CORRODED. MAINTENANCE FABRICATED AND INSTALLED NEW FLOORBOARD.
Back to JASC 5321