JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR MWEA99967Floor Panel · damagedCOCKPIT FLOOR HAS A HOLE IN IT, 6 AFT. OF F/O'S LOWER INBOARD SEAT RAIL. MAINTENANCE FABRICATED AND INSTALLED DOUBLER.SDR QXEA9902651Floor Panel · corrodedPDX - MAIN ENTRY THRESHOLD WHERE FLOOR PANEL ATTACHES HAD NUMEROUS SPOTS OF CORROSION. REPAIRED IAW DHC-8 SRM 51-40-11.SDR CALA9901624Floor Panel · corrodedINSPECTION FOUND AFT PIT FLOOR PANEL CORRODED. A NEW FLOOR PANEL WAS INSTALLED IAW SRM 51-30-5, 51-10-2, AND MM 51-20-0.SDR AT9900912Floor Panel · corrodedFOUND CORROSION AROUND FASTENER HOLES ON FLOOR PANEL NR 71. FABRICATED AND INSTALLED REPAIR IAW SRM 53-3 AND 51-30-2.SDR CALA9901575Floorboard · corrodedINSPECTION FOUND COCKPIT FLOORBOARD BETWEEN TWO LOWER FIRST OFFICER'S SEAT TRACKS CORRODED. THE FLOORBOARD WAS REMOVED AND A NEW FLOORBOARD WAS INSTALLED IAW SRM 53-05, FIGURE 1.SDR RRXA000494Floorboard · crackedDURING A MAINTENANCE VISIT FOUND FLOOR PANEL CRACKED BETWEEN STA 1580 TO STA 1600. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 51-3-0.SDR AALA991920Floorboard · corrodedTUL - FOUND CORROSION ON COCKPIT FLOORBOARD, STATION 148 BETWEEN SEAT TRACKS, RIGHT SIDE RBL 23-27. INSTALLED NEW FLOORBOARD PER SRM 51-01. (M)SDR TWAA9917503Floor Panel · corrodedDURING OP 16 MAINT CHECK, FOUND THE CABIN FLOOR MEMBRANE AND FORMER FOOT AT LONGERON 18R, STA 945, APPROX RBL 58 WAS CORRODED. REMOVED CORROSION AT FORMER FOOT AND ATTACH AREA PER SRM 51-10-3. REINSTALLED FORMER FOOT AND NEW FAB MEMBRANE PER SRM 51-30/51-1-4SDR TWAA9917502Floor Panel · corrodedDURING OP 16 MAINT CHECK, THE CABIN FLOOR MEMBRANE AND FORMER FOOT WAS CORRODED AT STA 929, APPROX RBL 58. REMOVED CORROSION AT FORMER FOOT AND ATTACH AREA SRM 51-10-3. REINSTALLED FORMER FOOT AND NEW FAB MEMBRANES PER SRM 51-30/51-10-4/53-05 FIG 97 AT STA 9SDR AT9900867Floor Panel · crackedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND FLOOR PANEL CRACKED AND CORRODED AT BS 160-200. FABRICATED AND INSTALLED FLOOR PANEL AND HAT CHANNELS IAW DC9 SRM 53-21 FIG 20, 51-10-02, 51-10-04, 51-10-03, AND 51-30-03.SDR AT9900860Floor Panel · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CABIN FLOOR PANEL BS 579-680 TO BE CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED NEW FLOOR PANEL IAW DC9 SRM 51-10-03, 51-10-04, 51-30-02, AND 53-21.SDR AT9900859Floorboard · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND CABIN FLOOR PANEL BS 237 RBL 47 CORRODED BEYOND LIMITS. REMOVED AND REPLACED FLOOR PANEL AT BS 237 RBL 47 IAW DC9 SRM 51-20-02, 51-10-04, 51-10-02, 51-30-02, AND 51-21.SDR QXEA9902503Floor Panel · corrodedPDX - CORROSION ON CO-PILOTS FLOOR, 11 FORWARD OD COCKPIT AFT WALL, JUST OUTBOARD OF CO-PILOTS RIGHT SEAT TRACK. REPAIRED IAW FOKKER SRM 51-10-4.SDR QXEA9902502Floor Panel · corrodedPDX - BL33.0 WL22.047 CORROSION IN SEVERAL PLACES, NEAR AFT WALL 3 OUTBOARD OF CO-PILOTS RIGHT SEAT TRACK. REPAIRED IAW FOKKER SRM 51-10-4.SDR MWEA99822Floor · crackedREMOVED CENTER FLOOR BETWEEN LAVS FOM SEVERAL OF THE HAT CHANNELS ON THE FLOORBOARD WERE CRACKED. MTC FABRICATED AND INSTALLED NEW CENTER FLOOR.SDR 2000ZZZX697Floor Panel · corrodedCORROSION EXISTS ON THE SURFACE OF ALL FLOOR PLANKS FROM STA 280 TO STA 1490 L21L TO L21R. REMOVED CORROSION BY CHEMICAL METHOD. TREATED AND PRIMED. IT IS ACCEPTABLE TO RETURN TO SERVICE PER EO 99-136 WITH APPROVED 8110-3 DATED 8-11-99. REF: ZANTOP INTERNATSDR 20000522AP013Floorboard · crackedFOUND DURING D-CHECK, FOUND CABIN STATION 45 XCW 53 LEFT - XCW 53 RT FLOOR MEMBRANE NUMEROUS CRACKS. FABRICATED DOUBLER IAW DC-8 SRM 53-2-0, 51-1-4. TREATED, PRIMED, AND INSTALLED DOUBLER IAW DC-8 SRM 51-1-8, 51-1-21, 53-2-0. (M)SDR RRXA000322Floorboard · crackedDURING A MAINTENANCE VISIT FOUND FLOOR PANEL MEMBRANE CRACKED AT STA 45 AND BL 53 RIGHT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-0.SDR ABXA9900798Floor · corrodedDURING D-CHECK, FOUND COCKPIT FLOOR PANEL CORRODED FROM STATION 140-160 AND RBL 10-48. REPLACED FLOOR PANEL IAW DC9 SRM 53-21-0.SDR TWAA9917510Floor Panel · corrodedDURING OP 16 MAINT CHECK,THE CABIN FLOOR AT STA 160 TO 200 HAD HEAVY CORROSION ON FLOOR PANEL ATTACH ANGLE RBL 45 IN. REMOVED AND REPLACED SUPPORT PER SPM 6-70-01.SDR TWAA9917509Panel · wornDURING OP 16 MAINT CHECK, FOUND CABIN FLOOR AT STA 160 TO 200, LBL 0 TO LBL44, FLOOR PANEL MEMBRANE WITH DEEP WORN AREAS FROM CHAFING FLOOR PANEL WORN ALMOST THROUGH IN 22 PLACES. REMOVED AND REPLACED MEMBRANES FROM STA 160 TO 200, BLB 0 TO LBL 44, PER STD PRSDR TWAA9917508Floor Panel · wornDURING OP 16 MAINT CHECK, FOUND CABIN FLOOR AT STA 160 TO 200, RBL 0 TO 50 IN, THE FLOOR PANEL MEMBRANE WITH A HEAVY WORN DEEP AREA IN MEMBRANE FROM FLOOR PANEL CHAFING WORN ALMOST THROUGH. REMOVED AND REPLACED MEMBRANE FROM STA 160 TO 200, RBL 0 TO 50, PER SSDR ASAA9980240Floor Panel · corrodedPHX - DURING 30K CHECK, FOUND CORROSION ON CABIN FLOOR PANEL AT FS 206. REMOVED CORROSION AND INSTALLED DOUBLER IAW DC9 SRM 53-01, FIG 4. (M)SDR ASAA9980239Floor Panel · corrodedPHX - DURING 30K CHECK, FOUND CORROSION ON CABIN FLOOR PANEL FROM FS 180 TO 188. REMOVED DAMAGED MATERIAL AND INSTALLED NEW PANEL IAW DC9 SRM 51-10-03, FIG 1. (M)SDR ASAA9980238Floor Panel · corrodedPHX - DURING 30K CHECK, FOUND CORROSION ON CABIN FLOOR PANEL FROM FS 148 TO 210. REMOVED DAMAGED MATERIAL AND INSTALLED NEW PANEL IAW DC9 SRM 51-30-02 AND 51-30-05. (M)SDR ABXA9900810Floor Panel · crackedDURING C-CHECK, FOUND COCKPIT FLOOR PANEL CRACKED AT STATION 132 AND RBL 4.0. REPLACED FLOOR PANEL IAW DC9 SRM 53-21-0 AND DACO DWG 9957827.SDR TWAA9917605Floor Panel · crackedDURING OP 16 MAINT CHECK, FOUND CABIN FLOOR MEMBRANE AT STA 598, APPROX RBL 55 IN, WAS CRACKED. STOP DRILLED CRACK AND INSTALLED REPAIR DOUBLER PER SRM 53-01, FIG 4, SHEET 3, PAGE 19.SDR RRXA991790Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOOR PANEL BETWEEN STA 660 TO STA 750. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FLOOR PANEL IAW DC-8 SRM 53-2-3. CORROSIONSDR RRXA991789Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOOR PANEL BETWEEN STA 750 TO STA 860. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FLOOR PANEL IAW DC-8 SRM 53-2-3. CORROSIONSDR RRXA991788Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOOR PANEL BETWEEN STA 40 TO STA 80 AND BETWEEN BL 56L TO BL 68L. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FLOOR PANEL IAW SDR RRXA991787Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOOR PANEL BETWEEN STA 1240 TO STA 1348 AND BETWEEN BL 48L TO BL 62L. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FLOOR PANEL SDR RRXA991786Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOOR PANEL BETWEEN STA 340 TO STA 346. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FLOOR PANEL IAW DC-8 SRM 53-2-3. CORROSIONSDR AT9900854Floor Panel · corrodedFOUND FLOOR PANEL CRACKED (HAT SECTION) AND CORRODED AROUND SCREW HOLE. FABRICATED PANEL REPAIR, FABRICATED 5 REPAIR HAT SECTIONS, DRILLED, DEBURRED, TREATED, PRIMED, AND INSTALLED REPAIR AND HAT SECTIONS IAW DC9 SRM 51-10-4, 51-10-3, 51-30-2, AND DC9 MM 25-1SDR AT9900853Floor Panel · corrodedFOUND FLOOR PANEL NR 4692A WAS CORRODED. GAINED ACCESS, REMOVED HAT SECTIONS, FABRICATED NEW FLOOR PANEL, TREATED, PRIMED INSTALLED HAT SECTIONS AND PANEL IAW DC9 SRM 51-30-2, 57-10-2, 51-10-3, 51-70-2 AND DC9 MM 53-20-1.SDR AT9900845Floor Panel · corrodedFOUND UPPER SKIN LOOSE AND CORROSION ALONG AFT EDGE OF FLOOR PANEL NR 4695. REMOVED, FABRICATED AND INSTALLED UPPER SKIN AND HAT SECTIONS IAW DC9 SRM 53-01, 51-10-31, 53-21-0, 51-30-3, DC9 MM 25-11-0.SDR 20000522AP014Floorboard · crackedFOUND DURING D-CHECK, FOUND CABIN STATION 1380 FLOOR MEMBRANE CRACKED AT FLOORBEAM. REMOVED MEMBRANE IAW DC-8 SRM 51-1-21. FABRICATED MEMBRANE, TREATED, PRIMED AND INSTALLED IAW DC-8 SRM 51-1-4, 51-1-8, 51-1-21. (M)SDR RRXA000321Floorboard · crackedDURING A MAINTENANCE VISIT FOUND FLOOR PANEL MEMBRANE AT STA 1380 AND LONGERON 21 LEFT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED MEMBRANE IAW DC-8 SRM 51-1-21.SDR RRXA000313Floorboard · crackedDURING A MAINTENANCE VISIT FOUND FLOOR PANEL CRACKED BETWEEN STA 760 TO 1100. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3.SDR 20000424AP024Floorboard · crackedFOUND DURING D-CHECK, UPPER CARGO COMPT FLOOR PANEL 760-1100, 5-6 INCH CRACK ON FLOOR PANEL. CUT OUT DAMAGED AREA IAW DC-8 SRM 53-2-0. FABRICATED REPAIR DOUBLERS. TREATED, PRIMED, INSTALLED IAW DC-8 SRM 51-1-8 AND 53-2-3 AND 51-1-21. (M)SDR 20000424AP025Floorboard · corrodedFOUND DURING D-CHECK, UPPER CARGO COMPT FLOOR PANEL 580-840 AREA OF EXFOLIATION. REMOVED CORROSION IAW DC-8 SRM 51-1-8. FABRICATED REPAIR DOUBLER. TREATED, PRIMED AND INSTALLED IAW DC-8 SRM 51-1-8 AND 53-2-0 AND 51-1-21. (M)SDR RRXA000212Floorboard · corrodedDURING MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER CARGO COMPARTMENT FLOOR PANEL BETWEEN STA 580 TO STA 840. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SSDR RRXA000265Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOOR PANEL BETWEEN STA 880 TO STA 1100 AND BL 45R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DC-8 SRM 53-2-3.SDR UPS99830875Floor · misinstalledINSPECTION TYPE:N/A, EVACUATION SLIDE GIRT BAR COULD NOT BE INSTALLED BECAUSE OF FLOOR PANEL RAISED TO HIGH. REINSTALLED FLOOR PANEL TO BE FLUSH WITH FLOOR, OPS CHECK GOOD.SDR UPS99230873Floor · crackedINSPECTION TYPE:N/A, CRACK APPROX 6 INCHES LONG IN AFT LOWER PIT FLOOR JUST FORWARD OF DOOR. FABRICATED AND INSTALLED FLOOR PANEL I/B OF DOOR PER SRM 51-10-1.SDR RRXA000280Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOOR PANEL BETWEEN STA 340 TO STA 360 AND BETWEEN LONGERONS 32 LEFT TO 32 RIGHT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED NEW FLOOR PANEL.SDR RRXA000278Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOOR PANEL BETWEEN STA 260 TO STA 280 AND BETWEEN LONGERONS 32 LEFT TO 32 RIGHT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED NEW FLOOR PANEL ANDSDR RRXA000277Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOOR PANEL BETWEEN STA 260 TO STA 280 AND BETWEEN LONGERONS 32 LEFT TO 32 RIGHT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED NEW FLOOR PANEL ANDSDR RRXA000272Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FLOOR PANEL BETWEEN STA 55 TO STA 62 AND BL 48L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED NEW FLOOR PANEL AND INSTALLED IAW DC-8 SRM 51-1-9.SDR USAA991111Floor · corrodedPIT - DURING Q2 CHECK, FOUND 2 FOOT BY 3 FOOT CORRODED AREA AT SUB-FLOOR AT STA 160 - STA 200 AND BETWEEN CENTERLINE OF AIRCRAFT AND RT INBOARD SEAT TRACK. CORROSION TASK NR C46-53303 CORROSION LEVEL 1. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER PER SRM 53-0SDR CALA9901343Floor · corrodedE AND E BAY CEILING STA 207 LBL 6 CORROSION ON FLOOR. FABRICATED REPAIR FROM 7075-T6 .020. TREATED, PRIMED, INSTALLED PER SRM 53-01 AND 53-10-3.
Back to JASC 5321