JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR COMA9960563Floor · crackedFS 280 IS CRACKED AT RBL 9 OUTBOARD SIDE. PERFORMED A MAJOR REPAIR, FABRICATED AND INSTALLED A REPAIR ANGLE AT FS 280, RBL 9 IAW WVAC EO 601R-53-0394.SDR MWEA99649Floor · crackedSUBFLOOR IS CRACKED AT RIVET HOLE AT STATION 205. MAINTENANCE FABRICATED AND INSTALLED NEW FLOOR DOUBLER.SDR MWEA99648Floor · crackedSUBFLOOR CRACKED AT STATION 210 AT NUT PLATE. MAINTENANCE FABRICATED AND INSTALLED DOUBLER.SDR AT9900750Floor · corrodedFOUND RT INBOARD FLOOR PANEL AT BS 579-617 CORRODED. FLOOR PANEL HAT SECTION CORRODED ON SQUARE ENDS AND ANGLED ENDS. MOST OF THE FASTENER HOLES ON THE TOP OF THE FLOOR PANEL HAVE CORROSION AND CIRCULAR WEAR GROOVES. REMOVED CORROSION FROM AROUND FASTENER SDR TWAA9913514Floor · corrodedDURING CHECK-C MAINT, FOUND CORROSION ON FLOOR WEB AT STA 522 AND 541, LONGERON 18R. REPLACED WEB PER SRM 53-01, FIG 2, FROM STA 503 TO 551.SDR TWAA9913513Floor · corrodedDURING CHECK-C MAINT, FOUND CORROSION ON FLOOR WEB AT STA 503, LONGERON 18R. REPLACED WEB PER SRM 53-01, FIG 2, FROM STA 503 TO 551.SDR TWAA9913512Floor · corrodedDURING CHECK-C MAINT, FOUND CORROSION ON FLOOR WEB AT STA 1094, LONGERON 18R. REPAIRED PER SRM 53-01, FIG 2.SDR TWAA9913511Floor · corrodedDURING CHECK-C MAINT, FOUND CORROSION ON FLOOR WEB BETWEEN STA 1199 AND 1209. INSTALLED DOUBLER PER SRM 53-01, FIGURE 2.SDR TWAA9913510Floor · corrodedDURING CHECK-C MAINT, FOUND CORROSION ON FLOOR WEB AT STA 1079, APPROXIMATELY LONGERON 18R. REPAIRED PER SRM 53-01, FIG 2.SDR C2XA99IA510Floor · corrodedIAH - DURING C-CHECK INSPECTION, FLOOR PANEL 21FF WAS FOUND TO BE CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFFECTED FLOOR PANEL, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)SDR AT9900644Floor · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FLORIDA, FOUND THE RIGHT SIDE CABIN FLOOR PANEL AT BS 200-237 CORRODED. FABRICATED NEW PANELS AND INSTALLED NEW HAT CHANNELS IAW DC9 SRM 53-05, 51-10-04, 51-10-03, 51-30-02, 53-21-0.SDR COMA9960522Floor · crackedTHE FLOOR MEMBER (P/N 600-34017-17) AT FS 280 IS CRACKED L/2, APPROXIMATELY 1 TO THE RIGHT OF FLOOR SUPPORT AT RBL 9. PERFORMED A MAJOR REPAIR TO CRACKED FLOOR MEMBER (P/N 600-34017-17) AT FS 280 IAW WVAC EO 601R-53-0325A.SDR CALA9901187Floor · corrodedINSPECTION FOUND CABIN LT FLOOR SKIN CORRODED AT FS 1183, LBL 42. REMOVED FORWARD AND AFT FRAME FITTINGS TORQUE BOX DOUBLER AND VERTICAL STIFFENER IAW SRM 51-30-1 AND 51-30-5. A REPAIR WEB WAS INSTALLED IAW SRM 51-10-3, 51-10-4, 51-30-2, AND 51-30-5. THE FISDR CALA9901185Floor · corrodedINSPECTION FOUND COCKPIT RT FLOOR SKIN CORRODED AT FS 148, RBL 6. THE CORRODED AREA WAS CUT OUT, FILLER AND DOUBLER WERE INSTALLED IAW SRM 53-01, FIGURE 4, 51-10-3 AND 51-30-2.SDR AT9900737Floor · crackedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL,FOUND FLOORBOARD #71 TO HAVE CRACKED HAT CHANNEL AND CORRODED SKIN BEYOND LIMITS. CORRECTIVE ACTION: REMOVED AND FABRICATED FLOORBOARD #71 SKIN AND HAT CHANNEL IAW DC9 SRSDR AT9900731Floor · corrodedFOUND FORWARD ENTRY FLOOR PANEL NR 4699 CHANNEL TIPS CHAFED, CORROSION AROUND NUT PLATES, AND CORROSION ON TOP AND BOTTOM SURFACES. FABRICATED NEW PANEL AND HAT SECTIONS IAW DC9 SRM 51-10-2, 51-10-3, 51-30-2, 53-21-0.SDR AT9900697Floor · corrodedFOUND FLOOR PANEL UNDER 1ST OFFICERS SEAT CORRODED AT BS 120-131. FABRICATED NEW FLOOR PANEL AND HAT FRAMES. INSTALLED NEW HAT FRAMES AND FLOOR PANEL IAW DC9 SRM 53-05 FIGURE 1, 51-30-2.SDR AT9900696Floor · crackedFOUND FLOOR PANEL AT FS 598 CRACKED AND CUT, 3 HAT CHANNELS CRACKED. FABRICATED NEW PANEL AND INSTALLED NEW HAT CHANNELS IAW DC9 SRM 51-10-1, 51-10-2, 51-10-4, 51-10-3, 51-30-2.SDR AT9900678Floor · corrodedCABIN FLOOR PANEL (NR 75) HAD CORROSION AROUND THE ATTACHMENT DURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, THE HOLES. REMOVED CORROSION AROUND FASTENER HOLES OF FLOOR PANEL NR 75. CHECKED WITH CALIPER NR A-2542 IAW DC9 SRM 53-01 AND FOUND TO BE OUSDR AT9900676Panel · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY, FL, FOUND SUBFLOOR PANEL WAS CORRODED AT LT CUSPLINE TO BS 0 AND RT CUSPLINE TO BS 160-218. REMOVED, FABRICATED, AND INSTALLED 3 EACH SUBFLOOR PANELS AT BS 160-218 IAW DC9 SRM 51-30-2, 53-30-2, 51-30-5, 51-SDR AT9900727Floor · corrodedFOUND FORWARD ENTRY FLOOR PANEL 4692B WAS CORRODED, 3 HAT SECTIONS LOOSE, AND GIL LINER STRIPS MISSING. FABRICATED NEW PANEL IAW DC9 SRM 53-21-0, 51-10-3, 51-30-2.SDR CALA9901134Floor · puncturedINSPECTION FOUND COCKPIT RT FLOOR SKIN PUNCTURED AT FS 148, RBL 14. THE PUNCTURED AREA WAS REMOVED AND TWO DOUBLERS WERE INSTALLED IAW SRM 53-10-1, FIGURE 12, SHEET 2.SDR AT9900730Floor · corrodedFOUND FORWARD ENTRY FLOOR PANEL NR 4698 WAS CORRODED AND HAD ELONGATED MOUNT HOLES. FABRICATED NEW PANEL IAW DC9 SRM 51-10-2, DPS3-40.9.SDR AT9900728Floor · corrodedFOUND FLOOR PANEL 4697B CRACKED AND CORRODED. FABRICATED NEW PANEL IAW DC9 SRM 51-10-2 TO 51-30-2.SDR AT9900665Floor · corrodedDURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY FL, FOUND FLOOR PANEL AT REAR OF COCKPIT, BETWEEN ELECTRICAL PANEL AND RIGHT SIDE WALL CORRODED. REMOVED, FABRICATED NEW SKIN. INSTALLED CHANNELS ON SKIN AND INSTALLED PANEL IAW DC9 SRM 51-10-3, 51-10-4, 51-30SDR AT9900664Floor · corrodedDURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY FL, FOUND RT OUTER FLOOR PANEL NR 40 HAS ELONGATED HOLES AND CORROSION. FABRICATED NEW FLOOR PANEL IAW DC9 SRM 51-30-21, 51-10-2/-3/-4.SDR AT9900662Floor · corrodedDURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY FL, FOUND RT OUTER FLOOR PANEL NR 39 HAS ELONGATED HOLES AND CORROSION. FABRICATED NEW FLOOR PANEL SKIN AND REINSTALLED HAT CHANNELS IAW DC9 SRM 53-21-0, 51-70-3.SDR AT9900655Floor · corrodedDURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY FL, FOUND FORWARD ENTRY SUBFLOOR PANELS AND SUPPORT BRACKEST AT BS 160-200 LBL 56 - RBL 56 CORRODED. REPLACED 3 PANELS, REMOVED AND REPLACE SUPPORT BRACKET, REPLACED RETAINER PLATE, REMOVED AND REPLACED DOUBLERSDR AT9900675Floor · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY, FL, FOUND FORWARD ENTRY FLOOR PANEL NR 894 WAS CORRODED. FABRICATED NEW SKIN FOR FLOOR PANEL NR 894 IAW DC9 SRM 51-10-3, 51-30-2.SDR AT9900674Floor · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY, FL, FOUND FORWARD ENTRY FLOOR PANEL NR 4696 WAS CORRODED. FABRICATED NEW SKIN FOR FLOOR PANEL NR 4696 IAW DC9 SRM 51-10-3, 51-30-2.SDR DHL9980668CFloor · puncturedAT C CHECK, CENTER FLOOR STA 1240-1260 HAS HOLES IN MIDDLE OF PANEL. FABRIACATED DOUBLERS TWO 3 BY 3 FT AND TWO 1 BY 1 PER SRM 53-2-0. N/R 802.SDR DHL9980636CFloor · crackedAT C CHECK, C3 CARGO COMPT FLOOR FROM STA 1140-1160 CENTER HAS CRACK AROUND GOUGE ON LWR SIDE. TRIMMED CRACKED AREA OF FLOOR BOARD, FABRICATED REPAIR DOUBLER IAW DC8 SRM 53-2-0 FIG 1D. INSTALLED DOUBLER IAW DC8 SRM 51-1-21, PG 1. N/R CARD NR 0810.SDR RRXA991719Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL E-2 BETWEEN Y=1500 TO Y=1540. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENGSDR RRXA991749Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL E-2 BETWEEN Y=1580 TO Y=1680. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENGSDR RRXA991747Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL C-2 BETWEEN Y=1500 TO Y=1540 AND X=-10. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVSDR RRXA991720Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL D-2 AT Y=1560. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENGINEERING SKETCHSDR AT9900726Floor · corrodedFOUND FLIGHT DECK CENTER FLOOR PANEL CORRODED AT BS 160 LONG 30. FABRICATED FLOOR PANEL IAW DC9 SRM 51-10-2, 51-30-2.SDR AT9900613Floor · corrodedDURING SCHEDULED INSPECTION AT TIMCO LAKE CITY FLORIDA, FOUND CABIN FLOOR PANEL AT BS 160-200 CORRODED. REMOVED HAT SECTIONS, CUT AND DRILLED NEW SKIN PANEL AND INSTALLED HAT SECTIONS IAW DC9 SRM 53-05 PG 1, 51-30-2, 51-10-3.SDR AT9900612Floor · corrodedDURING SCHEDULED INSPECTION AT TIMCO LAKE CITY FLORIDA, FOUND CABIN FLOOR PANEL AT BS 200-237 CORRODED. FABRICATED AND INSTALLED NEW FLOOR PANEL IAW DC9 SRM 51-10-2, 51-30-3, 53-21-0.SDR RRXA991510Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, UPPER CARGO COMPARTMENT FLOOR PANEL CORRODED (EXFOLIATION) REQUIRES REPAIR DOUBLERS. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIRED FLOOR PANELS IAW DC8 SDR RRXA991508Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, UPPER CARGO COMPARTMENT FLOOR PANEL CORRODED (EXFOLIATION) REQUIRES SKIN REPLACEMENT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FILLED GAP WITH HYSOLEA934NA.SDR CALA9901071Floor · delaminatedINSPECTION FOUND FLOOR PANEL 283KF DELAMINATED WITH CORRODED FERRULES. A NEW FLOOR PANEL WAS INSTALLED IAW GMM 10-100-01.SDR AT9900643Floor · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FLORIDA, FOUND THE UPPER AND LOWER SURFACES OF THE CABIN FLOOR PANEL AT BS 160-200 CORRODED. FABRICATED AND INSTALLED NEW SKIN PANEL IAW DC9 SRM 53-05, 53-20, 51-30-2.SDR AT9900646Floor · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FLORIDA, THE FLOOR PANEL AT BS 160-200 WAS FOUND TO BE CORRODED. FABRICATED AND INSTALLED NEW SKIN PANEL IAW DC9 53-21, 51-10-04, 51-10-03, 51-30-02.SDR AT9900645Floor · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FLORIDA, THE RIGHT SIDE FORWARD CABIN FLOOR PANEL AT BS 200-237 WAS FOUND TO BE CORRODED. FABRICATED NEW PANEL AND INSTALLED HAT CHANNELS IAW DC9 SRM 53-21, 51-10-02, 51-10-03, 51-30-02.SDR AT9900647Floor · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FLORIDA, THE LEFT SIDE CABIN FLOOR PANEL AT BS 200-237 WAS FOUND TO BE CORRODED. FABRICATED NEW SKIN PANEL AND INSTALLED HAT CHANNELS IAW DC9 SRM 53-21, 51-10-04, 51-10-03, 51-10-02.SDR AT9900606Floor · weakSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, UPON INSTALLATION FOUND CABIN FLOORBOARD NR 97 WEAK. FABRICATED A REPLACEMENT FLOORBOARD PANEL IAW DC9 SRM 53-21-0, DOUGLASS DRAWING NR 9915532 AND TIMCO RES NR 07642.SDR AT9900649Floor · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FLORIDA, THE COCKPIT FLOORBOARD BETWEEN THE CAPTAIN AND FIRST OFFICER BY THE INBOARD SEAT TRACKS WAS FOUND TO BE CORRODED. FABRICATED AND INSTALLED REPAIR PANEL IAW DC9 SRM 51-30-02, 51-10-02, 51-10-03, 51-1SDR AT9900650Floor · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FLORIDA, THE RIGHT SIDE CABIN FLOOR PANEL AT BS 160 - 200 WAS FOUND TO HAVE CORROSION. FABRICATED AND INSTALLED NEW FLOOR PANEL IAW DC9 SRM 53-21 FIGURE 2E.SDR AT9900729Floor · corrodedFOUND FORWARD ENTRY FLOOR PANEL 4692 HAD 2 CRACKED CHANNELS, TWO CHANNELS LOOSE, AND CORROSION ON EDGE OF PANEL. FABRICATED NEW PANEL IAW DC9 SRM 53-21-0, 51-10-3, 51-30-2.
Back to JASC 5321