JASC 5321

Service difficulty reports · 49,402

Reports filed under 5321 · Fuselage Floor Panel, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '5321'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AT9900775Web · corrodedFOUND 4 CRACK AT BS 955-960, LBL 48-52 IN CUSP WEB AND CORROSION OUT OF LIMITS. FABRICATED REPAIR IAW DC9 SRM 53-05 FIGURE 97, 51-10-3, 51-30-1, 51-30-2, AND DC9 MM 53-20-1.Aug 6, 1999 · N803AT · Doug DC932SDR UPS99230297Floor · corrodedINSPECTION TYPE:C, CORROSION (C53-111-03.00-01) ON DOG HOUSE FLOOR IN A FEW AREAS BS 342 TO 351, WL 169, RBL 14 TO 16. REMOVED CORRODED FLOOR BS 342 TO 351. FABRICATED NEW FLOOR AND INSTALLED IAW SRM 51-30-05 AND DRG NR 65-18415.Aug 5, 1999 · N935UP · Boeing 7271A7CSDR USAA990797Floorpan · corrodedCLT - DURING Q-1 CHECK VISUAL INSPECTION, FOUND SURFACE CORROSION 2 INCH BY 2 INCH AT STA 1024, RBL 6, WL 208 FLOORPAN. CORROSION LEVEL 1, CORROSION NR C53-107-02. FABRICATED NEW STRAP PER DRAWING 6546812 AND SRM 51-10-02. (X0Aug 3, 1999 · N341US · Boeing 737301SDR CALA9900943Floor · puncturedINSPECTION FOUND TWO PUNCTURES IN SUBFLOOR AT STA 200, LBL 50. A DOUBLER WAS INSTALLED IAW SRM 53-01, FIGURE 4, 51-10-3, 51-10-4, AND 51-30-2.Aug 2, 1999 · N83872 · Doug DC982SDR CALA9900933Floor · corrodedINSPECTION FOUND COCKPIT FLOOR PANEL LOCATED AT PILOT'S SEAT POSITION STA 150, LBL 40 CORRODED. A NEW FLOOR PANEL WAS INSTALLED IAW SRM 51-10-04 AND 51-10-03.Aug 1, 1999 · N83872 · Doug DC982SDR CALA9900929Floor · crackedINSPECTION FOUND A 6 INCH CRACK IN SUBFLOOR AT STA 150, LBL 12. THE CRACK WAS STOP DRILLED AND A REPAIR WAS INSTALLED IAW SRM 51-10-4, 51-30-2, AND 53-01, FIGURE 2.Aug 1, 1999 · N83872 · Doug DC982SDR CALA9900924Floor · corrodedINSPECTION FOUND SUBFLOOR AT FORWARD SERVICE DOOR ENTRANCE GIRT BAR ATTACH STRUCTURE CORRODED FROM STA 150 TO 200, LBL 58. THE SUBFLOOR WAS REMOVED AND A REPAIR WAS INSTALLED IAW SRM 51-30-1, 51-10-2, 51-10-4, AND 51-10-3.Jul 31, 1999 · N83872 · Doug DC982SDR CALA9900923Floor · corrodedINSPECTION FOUND SUBFLOOR CORRODED AT STA 148, BL 0. THE SUBFLOOR WAS REMOVED IAW SRM 51-30-2 AND A NEW ONE WAS INSTALLED IAW SRM 51-10-2, 53-11-1, 51-10-4, 51-10-3, AND 51-30-2.Jul 31, 1999 · N83872 · Doug DC982SDR CALA9900922Floor · corrodedINSPECTION FOUND CORROSION ON SUBFLOOR AT STA 160, LBL 10 TO LBL 18. THE SUBFLOOR AND FLOOR SUPPORT WERE REMOVED AND REPAIRS WERE INSTALLED IAW SRM 51-30-1, 51-10-03, 51-30-2, 51-30, 51-10-2, 53-11-1, 51-10-4, AND 51-30-5.Jul 31, 1999 · N83872 · Doug DC982SDR AT9900567Floor · corrodedDURING SCHEDULED CHECK AT TIMCO LAKE CITY FL, FOUND FWD ENTRY FLOOR PANEL AT BS 160-200 RT CORRODED. FABRICATED NEW PANEL IAW DC9 SRM 53-20-0, 51-10-4.Jul 29, 1999 · N866AT · Doug DC932SDR AT9900563Floor · corrodedDURING SCHEDULED CHECK AT TIMCO LAKE CITY FL, FOUND FLOOR PANEL ON RT SIDE AT BS 280 CORRODED. FABRICATED NEW PANEL AND INSTALLED IAW DC9 SRM 51-21-0, 51-30-1.Jul 29, 1999 · N866AT · Doug DC932SDR COMA9960401Floor · crackedFLOOR MEMBER P/N 600-34017-17 AT FS 280.00 IS CRACKED 2, APPROXIMATELY 1 TO THE RIGHT OF FLOOR SUPPORT OF RBL 9.0. PERFORMED A MAJOR REPAIR TO CRACKED FLOOR MEMBER P/N 600-34017-17 AT FS 280.00 IAW WVAC EO 601R-53-0117A.Jul 28, 1999 · N918CA · Cndair CL6002B19SDR CALA9900975Floor · corrodedINSPECTION FOUND CABIN FLOOR CORRODED AT STA 2007. REPAIRED IAW SRM 53-40-00.Jul 28, 1999 · N68060 · Doug DC1030SDR RRXA991725Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL B-3 BETWEEN Y=280 TO Y=580 AND X=40. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED Jul 27, 1999 · N791FT · Doug DC873FSDR RRXA991723Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL C-1 BETWEEN Y=280 TO Y=580 AND X=30. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED Jul 27, 1999 · N791FT · Doug DC873FSDR RRXA991698Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL E BETWEEN Y=280 TO Y=580 AND X=45. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DJul 27, 1999 · N791FT · Doug DC873FSDR AT9900545Floor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE FORWARD ENTRY FLOOR PANEL AT BS 180-200 CORRODED. FABRICATED FLOOR BOARD, DRILLED, DEBURRED, COUNTERSUNK, DRILLED AND INSTALLED HAT CHANNELS PARTS, AND INSULATION IAW DC9 SRM 53-01 FIG.1, 51-10-4, 51-30-Jul 27, 1999 · N866AT · Doug DC932SDR AT9900535Floor · corrodedDURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND FWD ENTRY RT FLOOR PANEL AT BS 200-280 CORRODED. 3 HAT CHANNELS CRACKED, ELONGATED HOLES AND INSULATION MISSING. FABRICATED NEW FLOOR PANEL AND HAT CHANNELS IAW DC9 SRM 53-21-0, 51-10-4. REINSTALLEJul 23, 1999 · N866AT · Doug DC932SDR SCNA99529Floor · corrodedDURING A HEAVY MAINTENANCE CHECK, THE FLOORBOARD SUPPORT AT STA 760 BBL 0 UNDER FLOORBOARD 3/10 SUPPORT WAS FOUND TO BE CRACKED. FABRICATED AND DRILLED AND TREATED AND PRIMED AND INSTALLED NEW PART WITH ANGLE REPAIRS IAW SRM 51403.Jul 22, 1999 · N290SC · Boeing 7272J4SDR AT9900614Floor · crackedDURING SCHEDULED INSPECTION AT TIMCO LAKE CITY FLORIDA, FOUND CUSP WEB CRACKED AT BS 955-960 LBL 48-52. REMOVED CUSP FOUND CORROSION. FORMED, DRILLED AND DEBURRED ONE CUSP SECTION AND FOUR REPAIR STRAPS. TREATED, PRIMED AND INSTALLED IAW DC9 SRM 53-05 FIG 9Jul 22, 1999 · N803AT · Doug DC932SDR AT9900607Floor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND RIGHT FLOOR PANEL AT BS 160-180 CORRODED. FABRICATED FLOORBOARD PANEL, DRILLED, DEBURRED, DIMPLED, ALODINED, PRIMED, AND INSTALLED NUT PLATES IAW DC9 SRM 53-21 FIG D, 51-10-4, 51-10-3, AND 51-30-2.Jul 21, 1999 · N866AT · Doug DC932SDR AT9900548Floor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE CABIN FLOOR PANEL NR 99 AT BS 200 CORRODED. REMOVED CORROSION, FABRICATED REPAIR DOUBLER, LOCATED, DRILLED, TREATED, PRIMED, AND INSTALLED DOUBLER IAW DC9 SRM 51-10-3, 51-10-4, AND 53-01.Jul 21, 1999 · N807AT · Doug DC932SDR AT9900534Floor · corrodedDURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND FLOOR PANEL NR 4693 AT BS 180-200 CORRODED ON TOP SIDE OF PANEL AND INSULATION TORN. REMOVED CORROSION, PANEL OUT OF LIMITS. FABRICATED NEW FLOOR PANEL IAW 53-21-0, 51-10-3, 51-30-2.Jul 21, 1999 · N866AT · Doug DC932SDR RRXA991713Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL BETWEEN Y=968 TO Y=973 AND BETWEEN X=45 TO X=59. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FJul 20, 1999 · N791FT · Doug DC873FSDR RRXA991712Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL BETWEEN Y=949 TO Y=952 AND BETWEEN X=45 TO X=59. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FJul 20, 1999 · N791FT · Doug DC873FSDR DHL9970309CFloor · crackedAT C CHECK, NOSE W/W PRESS FLOW HAS CRACK AT BS 284.5. REMOVED FLOOR PANEL AT FWD PER SRM 51-30-2. REMOVED 2 EACH OLD DOUBLERS PER SRM 51-30-2. CUT OUT DAMAGED AREA AT BS 284.5 4 BY 1 PER S/B 53-0145, HFEC INSPECTED CUTOUT IAW 51-00-0 FIG 4. NO CRACKS NOTEJul 20, 1999 · N703DH · Boeing 72730CSDR MWEA99410Floor · crackedSUB FLOOR PAN CRACKED AT 3 LOCATIONS BETWEEN STATION 120 TO 134. MTC FABRICATED AND INSTALLED DOUBLERS.Jul 19, 1999 · N700ME · Doug DC914SDR AT9900513Floor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND FLOOR PANEL AT BS 200-280 LEFT CORRODED ALONG EDGE UPPER AND LOWER FLANGE. CRACKS ON END HOLES IN PANEL. HAT CHANNEL CORRODED ENTIRE LENGTH. UPON FURTHER EVALUATION, FLOOR PANEL HAD EXFOLIATION CORROSION. Jul 19, 1999 · N866AT · Doug DC932SDR RRXA991711Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL A-3 BETWEEN Y=940 TO Y=980 AND X=50. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED Jul 16, 1999 · N791FT · Doug DC873FSDR RRXA991735Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL C-1 BETWEEN Y=1000 TO Y=1300 AND X=15. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVEJul 12, 1999 · N791FT · Doug DC873FSDR RRXA991729Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL C-3 BETWEEN Y=580 TO Y=880. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENGINJul 12, 1999 · N791FT · Doug DC873FSDR RRXA991728Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL D-3 BETWEEN Y=580 TO Y=880 AND X=-15. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED Jul 12, 1999 · N791FT · Doug DC873FSDR RRXA991726Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL A-2 BETWEEN Y=280 TO Y=580 AND X=50. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVEDJul 12, 1999 · N791FT · Doug DC873FSDR RRXA991724Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL D-1 BETWEEN Y=280 TO Y=580 AND X=-15. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVEDJul 12, 1999 · N791FT · Doug DC873FSDR RRXA991715Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL D-1 BETWEEN Y=1020 TO Y=1040. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENJul 12, 1999 · N791FT · Doug DC873FSDR RRXA991708Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL A-1 BETWEEN Y=900 TO Y=920. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENGIJul 12, 1999 · N791FT · Doug DC873FSDR RRXA991699Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL E AT Y=329 AND X=-50. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENGINEERINJul 12, 1999 · N791FT · Doug DC873FSDR HEEA062854Deck · separatedSERVICE DECK SEPARATED BEYOND ALLOWABLE REPAIR.Jul 12, 1999 · N108X · Bell 412SDR QXEA9901508Floor · corrodedPDX - FORWARD CARGO BAY FLOOR SKIN HAS CORROSION AROUND ANTENNA OPENING BETWEEN FLOOR FRAME 9305C AND 9805 AND BETWEEN STRINGER 1 AND 74. ALSO, THERE IS CORROSION ON ANTENNA MOUNT NUT PLATES. REPAIRED IAW FOKKER SRM 51-10-4, PAGES 8 AND 9 AND PARAGRAPH 4B.Jul 11, 1999 · N490US · Fokker F28MK4000SDR UPS99830092Floor · corrodedINSPECTION TYPE:C-2 CORROSION ON MAIN CABIN FLOORBOARD SPLICES (3) STA 1040 X10 TO X17. FABRICATED AND INSTALLED NEW SPLICE IAW DC8 SRM 51-3-0. MAT ID 7075-T 6 .063 PO NR 289791 IAW DC8 SRM 53-7-3, DAC DWG 289791.Jul 9, 1999 · N809UP · Doug DC873FSDR UPS99830091Floor · corrodedINSPECTION TYPE:C3 FLOOR BOARD F88 TO F90 HAS LARGE DOUBLER BULBED BY CORROSION AND EX FOLIATION SHOWING ON UNDERSIDE OF PLANK FABBED AND INSTALLED NEW SECTION AND SPLICES IAW DC8 SRM 53-2-3 FIG 9 AND 51-3-0.Jul 9, 1999 · N809UP · Doug DC873FSDR 9902719913Slat Press Panel · corrodedDURING PERIODIC CHECK, FOUND CORROSION ON LHS SLAT PRESSURE PANEL (P/N 5956065-41) AND RHS (P/N 5956065-43). REPAIRED PER EA 99-164469.Jul 6, 1999 · N963N · Doug DC931SDR RRAX000001Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL A-2 BETWEEN Y=880 TO Y=900. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENGJul 1, 1999 · N791FT · Doug DC873FSDR RRXA991748Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL B-3 BETWEEN Y=1580 TO Y=1680 AND X=-24. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVJul 1, 1999 · N791FT · Doug DC873FSDR RRXA991740Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL E-1 BETWEEN Y=1000 TO Y=1300 AND X=20. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVEJul 1, 1999 · N791FT · Doug DC873FSDR RRXA991734Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL B-3 BETWEEN Y=1000 TO Y=1300 AND X=40. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVJul 1, 1999 · N791FT · Doug DC873FSDR RRXA991733Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL B-2 BETWEEN Y=1000 TO Y=1300 AND X=40. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVEJul 1, 1999 · N791FT · Doug DC873FSDR RRXA991730Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL D-1 BETWEEN Y=880 TO Y=1000 AND X=-15. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVEJul 1, 1999 · N791FT · Doug DC873FSDR RRXA991727Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL D-1 BETWEEN Y=580 TO Y=880. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENGIJul 1, 1999 · N791FT · Doug DC873FSDR RRXA991722Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL C-1 BETWEEN Y=1580 TO Y=1680 AND X=-5. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVEJul 1, 1999 · N791FT · Doug DC873F
Back to JASC 5321