SDR RRXA991718Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL C-3 BETWEEN Y=1357 TO Y=1360 AND BETWEEN X=0 TO X=-8. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLERSDR RRXA991717Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL B-2 BETWEEN Y=1330 TO Y=1500 AND X=30. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVSDR RRXA991716Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL B-3 BETWEEN Y=1300 TO Y=1580. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENGSDR RRXA991710Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL A-2 BETWEEN Y=960 TO Y=1000. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENGSDR RRXA991706Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL E-1 BETWEEN Y=813 TO Y=990. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENGINSDR RRXA991705Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL B-3 BETWEEN Y=760 TO Y=1000 AND X=15. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVEDSDR RRXA991704Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL BETWEEN Y=584 TO Y=600. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENGINEERISDR RRXA991703Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL C-2 BETWEEN Y=580 TO Y=435 AND X=24. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED SDR RRXA991697Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL E BETWEEN Y=95 TO Y=110 AND BETWEEN X=-27 TO X=30. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAWSDR RRAX991706Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL A-2 BETWEEN Y=880 TO Y=900. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENGINSDR RRXA991732Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL C-3 BETWEEN Y=1000 TO Y=1300 AND X=-15. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVSDR RRXA991731Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL C-3 BETWEEN Y=1000 TO Y=1300 AND X=-10. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVSDR RRXA991714Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL C-3 BETWEEN Y=1000 TO Y=1300 AND X=15. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVSDR RRXA991702Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL AT Y=435 BETWEEN X=16 TO X=24. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENSDR AT9900594Floor · corrodedDURING A ROUTINE INSPECTION AT TIMCO LAKE CITY FL, FOUND CENTER FLOOR PANEL AT BL 0 TO RBL 22 AT BS 237-313 HAS SURFACE CORROSION AND INSULATION DETERIORATED. LOCATED AND DRILLED REPLACEMENT FLOOR PANEL ASSEMBLY IAW DC9 SRM 51-30-4. INSTALLED INSULATION IAW SDR RRXA991700Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL D-3 AT Y=360 BETWEEN X=16 TO X=24. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DSDR DHL9970233CFloor · crackedC CHECK, AFT CARGO COMPARTMENT AFT BULKHEAD AREA BOTTOM OF CABIN FLOOR HAS AREA OF CORROSION AND A CRACK LEFT SIDE. REMOVED FASTENERS AFT CARGO AFT BULKHEAD BOTTOM AREA AS PER 727 SRM 51-30-2. CUT OUT DAMAGE CORRODED AREA AS PER 727 SRM 51-40-2 SIZE CUT OUT SDR RRXA991750Angle · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO VERTICAL STABILIZER FRONT SPAR ATTACHMENT ANGLE AT Y=1766 AND X=24. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW SDR AT9900589Floor · corrodedDURING A ROUTINE INSPECTION AT TIMCO LAKE CITY FL, FOUND FWD CARGO COMPARTMENT FLOOR PANEL AT BS 351-484 CORRODED. CUT OUT AND DRILLED FLOOR PANEL IAW DC9 SRM 51-10-4.SDR AT9900588Floor · corrodedDURING A ROUTINE INSPECTION AT TIMCO LAKE CITY FL, FOUND AFT CARGO COMPARTMENT FLOOR PANEL AT BS 860-996 CORRODED. CUT OUT AND DRILLED FLOOR PANEL IAW DC9 SRM 51-10-4, 53-21-0.SDR 9902649984Slant Panel · corrodedDURING PERIODIC CHECK, FOUND CORROSION AT FS 700 SLANT PANELS. REPAIRED PER EA 99-164419. (P/N 5956065-5)SDR AALA990885Floor · corrodedTUL - EXFOLIATED CORROSION ON FLOOR PAN EXTRUDING UNDER AND CAUSING BULGING TO FLOOR STRAP ON FORWARD SIDE OF STATION 1183 BULKHEAD, AT LOWER RIGHT CORNER OF VAULT DOOR FRAME, RBL 14 - RBL 24. FABRICATED AND INSTALLED DOUBLER PER SRM 51-40-2 AND FLOOR PAN ON SDR RRXA991746Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL A BETWEEN Y=1300 TO Y=1680 AND X=56. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED SDR RRXA991739Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL A-2 BETWEEN Y=1000 TO Y=1300 AND X=50. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVESDR GTIA9900910Floor · corrodedMHV - STATION 140X=PLUS 35 TO PLUS 52, 9 BY 18 INCH AREA OF CORROSION DEEP POTTING .5 INCH PUNCTURE AND SURFACE CORROSION NUMEROUS AREAS TOP SURFACE COCKPIT FLOORBOARD. REMOVED CORRODED WEB FROM LOCATION REMOVING ALL ATTACH FASTENERS FABRICATED NEW FLOOR WEB SDR RRXA991745Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL A BETWEEN Y=1300 TO Y=1680 AND X=-10. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVEDSDR RRXA991744Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL A BETWEEN Y=1300 TO Y=1620 AND X=50. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED SDR RRXA991742Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL E-3 BETWEEN Y=1300 TO Y=1680 AND X=-20. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVSDR RRXA991741Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL D-3 BETWEEN Y=1300 TO Y=1680 AND X=-10. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVSDR RRXA991738Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL E-1 BETWEEN Y=1000 TO Y=1300 AND X=30. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVESDR RRXA991737Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL E-1 BETWEEN Y=1000 TO Y=1300 AND X=-30. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVSDR RRXA991736Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL F BETWEEN Y=1000 TO Y=1300 AND X=-50. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVEDSDR RRXA991709Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL D AT Y=907 AND X=-15. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER ENGINEERINGSDR RRXA991701Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO UPPER FLOOR PANEL BETWEEN Y=409 TO Y=417 AND LONGERON 21 LEFT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SDR UPS99829963Floor · corrodedINSPECTION TYPE:C-1, CORROSION ON FLOOR PANEL AT RBL 35 AT FS 350. REMOVED CORROSION, FABRICATED REPAIR DOUBLER IAW DC8 SRM 53-2-3 AND INSTALLED REPAIR.SDR USAA990561Floor · crackedCLT - DURING Q-1 CHECK, FOUND 1.5 INCH CRACK AND .400 INCH CRACK JUST AFT OF STATION 663.75 BL 32 IN PRESSURE FLOOR PANEL. INSTALLED DOUBLER, FILLER AND ANGLE STIFFENER PER EA 64667. (M)SDR UPS99829962Floor · corrodedINSPECTION TYPE:C-1 FLOOR PNL 58-880 ROW A IS CRACKED AT ATTACH HOLE, HAS 2 EACH GOUGES, NUMEROUS AREAS OF BARE METAL AND CORROSION, AND MISSING/DAMAGED NON- SKID. FOUND TO BE WITHIN LIMITS IAW DC8 SRM 53-2-0 FIG LF. INSTALLED NON-SKID TAPE AS NECESSARY IAW SDR UPS99829957Floor Panel · corrodedINSPECTION TYPE:C-1 FLOORBOARD CORRODED ROW-C FS880-1000. REMOVED CORROSION IAW DC8 SRM 51-1-8, REPAIR CORRODED AREA IAW DC8 SRM 53-2-3. ALODINE AND PRIME IAW DC8 SRM 51-1-8, INSTALL REPAIR DOUBLER IAW DC8 SRM 51-1-21.SDR UPS99829956Floorboard · corrodedINSPECTION TYPE:C-1 FLOOR PANEL FS 1470 LBL 35 HAS CORROSION BULGE AROUND INSERT. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW DC8 SRM 53-2-0, FAB DOUBLER IAW DC8 SRM 53-2-3, INSTALL DOUBLER IAW DC8 SRM 51-1-8.SDR UPS99829955Floorboard · corrodedINSPECTION TYPE:C-1 FLOORBOARD CORRODED AROUND INSERT FS 1420 LBL 10. REMOVED CORROSION IAW DC8 SRM 51-1-8, CUT OUT DAMAGE AND REPAIR IAW DC 8 SRM 53-2-3 ALODINE AND PRIME REPAIR DOUBLER IAW DC8 SRM 51-1-8. INSTALLED ALL REPAIR DOUBLER IAW DC8 SRM 51-1-21A.SDR RRXA991601Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN, AT STA 1688, FLOOR PANEL A CORRODED AND CRACKED AT LONGERON 21 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FLOORBOASDR USAA990546Floor · corrodedCLT - DURING Q-4 CHECK, FOUND 3 INCH CORROSION AT LT LAV FLOOR PAN. CORROSION LEVEL 1, CORROSION TASK NR C53-107-02. NEW WEB INSTALLED PER SRM 51-10-02. (M)SDR CALA9900626Floor · corrodedINSPECTION FOUND FORWARD CARGO RT SUPPORT FLOOR PANEL CORRODED AT STA 1099. A REPAIR ANGLE WAS INSTALLED IAW SRM 51-30-00.SDR TWAA9907902Floor · damagedDURING OP 16 MAINT CHECK, FOUND REPAIR ON FLOOR MEMBRANE BETWEEN STA 190 TO 210, LBL O IN TO 22 IN, WAS COMING LOOSE AND HAD POPPED RIVETS INSTALLED. REPLACED MEMBRANE PER SPM 6-70-01, 775T3 30 PER ORIGINAL SAMPLE.SDR USAA990508Floor · crackedCLT - DURING Q-2 CHECK, FOUND TWO .75 INCH CRACKS AT FORWARD END OF BEAD IN PRESSURE DECK/FLOOR AT STTION 6635 LBL 33. INSTALLED DOUBLER PER EA 64506 AND REV EA 64506A. (M)SDR GTIA9901026Floor · crackedMHV - CABIN CENTER RIGHT FLOOR PANEL STA 598 TO STA 639 HAS (5 EACH) CRACKS (3 EACH AT FASTENER HOLES AND TWO BELOW FASTENER HOLES). REPAIRED CRACKS INSTALLED DOUBLERS IAW SRM DC9 53-05 FAB DOUBLERS IAW SRM DC9 53-05 ALODINED AND PRIMED IAW SRM DC9 51-10-3. SDR GTIA9901010Floor · wornMHV - LEFT CABIN FLOOR PANEL STATION 669 TO 775 SKIN AROUND NUMEROUS SCREW HOLES TO THIN. RESKINNED FLOOR PANEL IAW SRM DC9 53-20 AND 53-05, FABRICATED SKIN PANEL ALODINED AND PRIMED. (M)SDR AT9900411Floor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE CABIN FLOOR PANEL NR 29 AT BS 236-308 RBL 1-24 CORRODED ON MOST OF FACE AND SPOTS ON BACKSIDE OF HAT SECTION REINFORCEMENTS. CUT OUT NEW SKIN AND HAT REINFORCEMENT SECTIONS. DRILL, TRIMMED, ASSEMBLED, TSDR AT9900389Floor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE FORWARD ENTRY FLOOR PANEL NR 4692 AT BS 200 BL 0-65R CORRODED. FABRICATED PARTS AND INSTALLED IAW DC9 SRM 53-01 FIG 1, 53-21-0 FIG 2D, 51-70-2, 53-05-0, AND 51-30-2.SDR AT9900397Floor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE FORWARD ENTRY FLOOR PANEL CORRODED AT BS 180-200 CENTER RIGHT HAND SIDE. FABRICATED, TRIMMED, DRILLED, FLOOR PANEL AND HAT SECTIONS, TREATED, PRIMED, AND INSTALLED IAW DC9 SRM 51-10-3, 53-01 FIG.1, AND 51
Back to JASC 5321