SDR AT9900395Floor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE RIGHT OUTBOARD FORWARD ENTRY FLOOR PANEL AT BS 160-200 CORRODED. FABRICATED FLOOR PANEL, TREATED, AND PRIMED IAW DC9 SRM 51-10-3, 53-01 FIG.1, 51-10-3, AND 53-21-0.May 18, 1999 · N867AT · Doug DC932SDR AT9900394Floor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE CABIN FLOORBOARD PANEL AT BS 200-218 CORRODED ON TOP SIDE AND AROUND EDGES. REMOVED CORROSION, DISSASEMBLED FLOOR PANEL, FABRICATED REPAIR AND REPLACEMENT SKIN, TRIMMED, DRILLED, DEBURRED, TREATED, PRIMEDMay 18, 1999 · N867AT · Doug DC932SDR AT9900439Floor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE FORWARD ENTRY FLOOR PANEL NR 4693 AT LBL 45-65 CORRODED. REMOVED FLOOR PANEL, FABRICATED, COUNTERSUNK, DEBURRED, TREATED, PRIMED, AND INSTALLED IAW DC9 SRM 51-10-3, 51-10-2, 53-21-0 FIG 2D.May 15, 1999 · N817AT · Doug DC932SDR AT9900402Floor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE CABIN FLOOR PANEL NR 90 CORRODED AROUND THE EDGES. REMOVED, FIT, TRIMMED, DRILLED, TREATED, AND PRIMED REPLACEMENT SKIN PANEL AND INSTALLED IAW DC9 SRM 53-21-0, 51-10-2, 51-10-4, AND 51-30-2.May 14, 1999 · N817AT · Doug DC932SDR AT9900393Floor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE FLOORBOARD SUBFLOOR BOTTOM SIDE CORRODED ON EDGES AND AROUND SCREW HOLES AT BS 160-200 LEFT SIDE. REMOVED CORROSION, FABRICATED REPAIR SKIN, DRILLED, COUNTERSUNK, DEBURRED, TREATED, PRIMED, AND INSTALLED May 13, 1999 · N867AT · Doug DC932SDR AT9900388Floor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND SUB FLOORBOARD AT BS 160 TO 200 OUTBOARD RIGHT HAND TOP SIDE CORRODED. MECHANICALLY REMOVED CORROSION, FABRICATED, TRIMMED, DRILLED, DEBURRED, COUNTERSUNK PANEL, TREATED, PRIMED AND INSTALLED HAT SECTION IAWMay 13, 1999 · N867AT · Doug DC932SDR AT9900375Floor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE FORWARD FLOOR PANEL NR 4691 AT BS 160 TO 200 BL 0-45L CORRODED. FABRICATED NEW FLOOR PANEL, FIT, DRILLED AND INSTALLED NEW SKIN ON HAT CHANNELS AND REINSTALLED FLOOR PANEL IAW DC9 SRM 53-21-0, 51-10-2, AMay 12, 1999 · N817AT · Doug DC932SDR USAA990417Floor · crackedCLT - DURING Q-2 CHECK, NDT VISUAL INSPECTION, FOUND A .75 INCH CRACK AT BS 663.75 LBL 32 FLOOR. INSTALLED DOUBLER PER EA 64378. (M)May 2, 1999 · N413US · Boeing 737401SDR AT9900361Floor · corrodedSCHEDULED INSPECTION AT AERO CORP, FL, FOUND CORROSION ON THE SUB FLOOR AT BS 170-200 RBL 55. CUT OUT CORRODED PORTION OF SUB FLOOR. FORMED NEW DOUBLERS, DRILLED, DEBURRED, TREATED, PRIMED, AND INSTALLED DOUBLER IAW DC9 SRM 51-10-4, 51-10-3, 51-30-2, AND 53-2May 2, 1999 · N823AT · Doug DC932SDR AT9900366Floor · corrodedSCHEDULED INSPECTION AT AERO CORP, FL. FOUND CABIN FLOOR PANEL NR 5857 CORRODED UNDER FASTENERS. FABRICATED, TREATED, PRIMED, AND INSTALLED CABIN FLOOR PANEL IAW DC9 SRM 51-01 FIG 1, 53-05 FIG 1, 51-10-2, 51-10-3, 51-30-2, AND 51-30-1.Apr 28, 1999 · N823AT · Doug DC932SDR AT9900362Floor · corrodedSCHEDULED INSPECTION AT AERO CORP, FL, FOUND THE COCKPIT FLOOR BOARD JUST AFT OF FIRST OFFICER SEAT BOTTOM SEAT TRACK AT BS 130 LBL 20 CORRODED. FABRICATED REPAIR FLOOR BOARD. CUT, TRIMMED, DRILLED HOLES, DEBURRED, COUNTERSUNK, TREATED, PRIMED, AND INSTALLEDApr 22, 1999 · N823AT · Doug DC932SDR RAAA99B2029Floor · corrodedDURING SCHEDULED C CHECK, FOUND CORROSION ON FLOOR PLATE AROUND FWD LAV DUMP PIPE TOP AND BOTTOM SURFACES BS 303 TO 344. REMOVED CORROSION IAW SRM 51-10-06. TREATED AND PRIMED IAW SRM 51-10-06. REMOVED SUPPORT ANGLES AND FABRICATED NEW ANGLES OF 7075T6 .094Apr 21, 1999 · N832RV · Boeing 72722CSDR RAAA99B2028Floor · corrodedDURING SCHEDULED C CHECK, FOUND CORROSION ON FORWARD LAV FLOORBOARD ATTACH HOLES AND CAP SECTION OF CHANNEL BS320 TO 340 7 RBL14 TO RBL16. REMOVED CORROSION ON FLOORBOARD AND CAP SECTION AND TREATED AND PRIMED IAW SRM 51-10-06. REMOVED CHANNEL AND FABRICATEDApr 21, 1999 · N832RV · Boeing 72722CSDR AU990466Floor Panel · corroded(AUS) FUSELAGE FLOOR CORRODED IN SEVERAL AREAS. SUSPECT CAUSED BY LEAKING SIDE WINDOWS ALLOWING WATER TO ENTER AND SOAK INTO THE CARPET WHICH HAD BEEN DAMP FOR A LONG PERIOD. AIRCRAFT ALSO OPERATES IN A SALT AIR ENVIRONMENT.Apr 20, 1999 · Cessna 210NSDR AT9900386Floor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND CORROSION UNDER FASTENERS ON BOTH SIDES OF PANEL NR 5851 AT BS 313 TO 389. FABRICATED NEW PANEL WEB AND FIVE SECTIONS HAT CHANNELS, TRIMMED, DRILLED, DEBURRED, COUNTERSUNK, ASSEMBLED, TREATED AND PRIMED IAW Apr 15, 1999 · N823AT · Doug DC932SDR GTIA9901027Floor · crackedMHV - CABIN LT SIDE FLOOR PANEL STA 669 TO STA 775 CRACKED AT FASTENER HOLE WITH LIGHT SURFACE CORROSION AROUND FASTENER HOLES. SKIN REPLACEMENT NEEDED. COMPLETION OF WORK ON PANEL TO BE COMPELTED ON W122. (X)Apr 14, 1999 · N934ML · Doug DC931SDR AT9900387Floor · corrodedSCHEDULED INSPECTION AT TIMCO LAKE CITY, FL. FOUND THE R-1 FLOOR DOOR ENTRANCE AT BS 160 TO 197 RBL 54 CORRODED. REMOVED R-1 DOOR ENTRANCE PANEL, FABRICATED, PRIMED, PAINTED AND INSTALLED IAW DC9 SRM 53-01 FIG 1, 51-10-3 AND 51-30-0.Apr 14, 1999 · N823AT · Doug DC932SDR RRXA991225Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSEALAGE, LT CABIN FLOOR BETWEEN STA 680 AND STA 700 AT BL 54 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC8 SRM 53-2-3 PGS Apr 5, 1999 · N997CF · Doug DC862FSDR P2EA99161Floor · corrodedSJO - DURING C-CHECK, IN THE PASSENGER CABIN AFT LAVATORY AREA, BETWEEN BS 1016 AND BS 1016 PLUS 11 INCHES, FROM BL 0 TO RBL 36, FLOOR WEB WAS FOUND WITH CORROSION INCLUDING THE SUPPORT ANGLE. REPLACED FLOOR WEB BETWEEN BS 1016 TO BS 1032.5 FROM BL 0 TO RBL 3Apr 5, 1999 · N603DJ · Boeing 737222SDR DHL9980720CFloor · crackedAT C-CHECK, FLOOR PANEL IN FRONT OF CAPTAIN SEAT HAS CRACK APPROX 3 INCHES LONG. STOP DRILLED CRACK IN FLOOR PANEL, INSTALLED REPAIR DOUBLER PER SRM 51-1-21, 5 X 5.Mar 31, 1999 · N807DH · Doug DC873FSDR TWAA9904914Floor · corrodedDURING OP 16 MAINT CHECK, FOUND CABIN FLOOR MEMBRANE CRACKED AND CORRODED AT STA 1271 TO 1287, RBL 52 IN. REPLACED MEMBRANE WITH (P/N 9930612-11), PER SPM 6-70-01, PG 3. INSTALLED WITH FASTENERS PER SPM 6-30-01, PG 1 AND 2.Mar 25, 1999 · N916TW · Doug DC982SDR RRXA991251Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 700 AND STA 822 AT BL 49 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5Mar 24, 1999 · N997CF · Doug DC862FSDR RRXA991250Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 460 AND STA 540 AT BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53Mar 24, 1999 · N997CF · Doug DC862FSDR RRXA991249Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL BETWEEN STA 900 AND STA 920 AT BL 54 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53Mar 24, 1999 · N997CF · Doug DC862FSDR RRXA991248Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL AT STA 700 BL 36 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR FILLER AND ANGLE IAW DC8 SRM 51-1-8 PG 16Mar 24, 1999 · N997CF · Doug DC862FSDR RRXA991247Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL BETWEEN STA 1460 AND STA 1480 AT BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED IAW DC8 SRM 53-2-3 FIG 10 PMar 24, 1999 · N997CF · Doug DC862FSDR RRXA991246Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1460 AND STA 1480 AT BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM Mar 24, 1999 · N997CF · Doug DC862FSDR RRXA991245Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 1400, BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 52-2-3 PGS 39/40 FIGMar 24, 1999 · N997CF · Doug DC862FSDR RRXA991244Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL AT STA 880, BL 38 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-3 FIG 10 PGS 39/Mar 24, 1999 · N997CF · Doug DC862FSDR AT9900319Floor · corrodedSCHEDULED INSPECTION AT AERO CORP, FL, FOUND CORROSION ON FLOOR AT BS 965 LBL-50 JUST AFT OF WALL. REMOVED CORROSION, FABRICATED NEW DOUBLER, DRILLED, DEBURRED, TREATED, PRIMED, AND INSTALLED IAW DC9 SRM 51-10-3, 53-01 FIG 1, 51-10-4, 53-20-1, AND 51-30-2.Mar 23, 1999 · N818AT · Doug DC932SDR TWAA9904907Floor · corrodedDURING OP 16 MAINT CHECK, THE FIRST FLOOR PANEL I/B OF FWD GALLEY DOOR JAMB HAD CORROSION. FABRICATED FLOOR PANEL AND 2 NEW EVAC SLIDE CASTINGS. PRIMED AND PAINTED WHITE.Mar 22, 1999 · N916TW · Doug DC982SDR RRXA991255Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 600 AND STA 620 AT BL 8 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 51Mar 22, 1999 · N997CF · Doug DC862FSDR RRXA991254Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PANEL BETWEEN STA 660 AND STA 680 AT BL 20 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 53Mar 22, 1999 · N997CF · Doug DC862FSDR RRXA991253Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 840, BL 4 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 51-1-8 PG 16 AND 53-2-Mar 22, 1999 · N997CF · Doug DC862FSDR RRXA991252Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK AT STA 800, BL 54 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FILLER AND DOUBLER IAW DC8 SRM 53-2-3 FIG 10 PGSMar 22, 1999 · N997CF · Doug DC862FSDR AT9900330Floor · corrodedSCHEDULED INSPECTION AT AERO CORP, FL. FOUND THE AFT CARGO PIT CENTER FLOOR PANEL AT BS 832-915 CORRODED, PUNCTURED AND DENTED. FABRICATED FLOOR PANEL, DRILLED, DEBURRED, ALODINED IAW DC9 SRM 51-10-2, 51-10-3 AND 53-21-0 FIG 10.Mar 22, 1999 · N818AT · Doug DC932SDR RRXA991256Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 580 AND STA 879 AT BL 13 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 51Mar 21, 1999 · N997CF · Doug DC862FSDR RRXA991284Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FLOOR PANEL, CARGO COMPARTMENT NR 5 BETWEEN STA 460 AND STA 540 AT BL 20 RIGHT, WL 0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED PANEMar 18, 1999 · N8091U · Doug DC871FSDR RRXA991257Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN INT UNDER FLOOR PLANK TOP W/W AT STA 980, BL 24 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FITTING IAW DC8 SRM 51-1-8 PG Mar 18, 1999 · N997CF · Doug DC862FSDR AT9900317Floor · corrodedSCHEDULED INSPECTION AT AERO CORP, FL, FOUND THE CENTER AFT FLOOR BOARD BETWEEN AFT LAVATORY AND G-4 CORRODED, CRACKED AND WORNED HAT CHANNELS. FABRICATED NEW FLOOR BOARD AND HAT CHANNELS, ALODINED, PRIMED AND INSTALLED ALL PARTS AND INSULATION IAW DC9 SRM 51Mar 18, 1999 · N818AT · Doug DC932SDR AT9900264Floorboard · corrodedSCHEDULED INSPECTION AT AERO CORP, FL. FOUND THE AFT GALLEY FLOORBOARD AROUND THE DRAIN FITTING AT BS 996 LEFT HAND CORRODED. REPLACED SKIN AND STRINGERS IAW DC9 SRM 51-70-0, 51-10-2, AND 53-21-0.Mar 18, 1999 · N818AT · Doug DC932SDR AT9900318Panel · corrodedSCHEDULED INSPECTION AT AERO CORP, FL, FOUND THE FLOOR BOARD PANEL NR 61D SKIN BULGING/CORRODED. FABRICATED NEW PANEL AND HAT SECTIONS, DRILLED, DEBURRED, TREATED, PRIMED ALL PARTS AND INSTALLED PANEL AND CHAFFED STRIPS IAW DC9 SRM 51-30-2, 53-21-0, 51-30-1, Mar 17, 1999 · N818AT · Doug DC932SDR AT9900326Floor · corrodedSCHEDULED INSPECTION AT AERO CORP, FL, FOUND CORROSION ON THE ATTACH ANGLE AND THE FLOOR BOARD BELOW FORWARD LAVATORY. MECHANICALLY REMOVED CORROSION, REMOVED THRESHOLD AT FORWARD LAVATORY DOOR AND FLOOR TRIM TO GAIN ACCESS TO ATTACH ANGLE. FABRICATED REPAIR Mar 16, 1999 · N814AT · Doug DC932SDR RRXA991277Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, LAVATORY FLOOR AND SHROUD CONNECTED AT LOCATION BETWEEN STA 55 AND STA 70 AND BETWEEN BL 60 RIGHT AND BL 40 RIGHT AT WL 0. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 5Mar 15, 1999 · N8091U · Doug DC871FSDR DHL9980750CFloor · crackedAT C CHECK, GALLEY FLOOR PANEL HAS SURFACE CORROSION ON UPPER AND LOWER SIDES. ALSO, 2 CHANNEL FRAME ARE CRACKED STA 5- 25. CORROSION REMOVED ON PANEL AND WITHIN LIMITS AND REMOVED CHANNEL AND REPLACED PER SRM 51-1-21, 34.25 BY 4 N/R 647.Mar 15, 1999 · N807DH · Doug DC873FSDR DHL9980711CFloor · crackedAT C-CHECK, FLOOR PANEL GALLEY CENTER CHANNEL FRAME IS CRACKED. REMOVED DAMAGED PANEL, FABRICATED NEW AND INSTALLED PER SRM 51-1-21, 25 X 4.Mar 15, 1999 · N807DH · Doug DC873FSDR RRXA991263Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 330 AND STA 520 AT BL 12 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLERS IAW DC8 SRM 5Mar 14, 1999 · N997CF · Doug DC862FSDR RRXA991262Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 1500 AND STA 1520 AT BL 42 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRMMar 14, 1999 · N997CF · Doug DC862FSDR RRXA991260Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 360 AND STA 520 AT BL 54 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC8 SRM 5Mar 14, 1999 · N997CF · Doug DC862FSDR RRXA991259Floor Panel · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR PLANK BETWEEN STA 360 AND STA 520 AT BL 20 LEFT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW DC8 SRM 51-1-8 PGMar 14, 1999 · N997CF · Doug DC862F
Back to JASC 5321