JASC 5322
Service difficulty reports · 12,776
Reports filed under 5322 · Fuselage Internal Mounting Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5322' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5322' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023011016125Shear Tie · corrodedR/H PRESSURE DECK SHEAR TIE AT STA 665 TO 669 RBL 65 TO RBL 70 WL 202 HAS AREA OF CORROSION. REMOVED CORROSION IAW SRM 51-10-02-0G-0; EVALUATED MATERIAL LOSS - ORIGINAL THICKNESS .063'; LOSS OF .006'; REMAINING .057'. NO ALLOWABLE MATERIAL LOSS LIMITS. RECESDR SWIA202266768None · corrodedFS 349.0 AT RBL 36 FLOOR SUPPORT HAS CORROSION.(MARKED) (C-CHECK RO 11/8/2022) REPAIRED FS 349.0 AT RBL 36 FLOOR SUPPORT REF REO 601R-53-21-2745, REV --, DATED 2016-11-18. COMPIED WITH 51-900-1003-SKY SEE CONTINUATION CARD FOR DETAILS. COMPLIED WITH ALSDR SWIA202266767None · crackedFS 280 AT APPROX RBL 11.0 UNDER FLOOR FWD OF FLOOR SUPPORT STIFFNER HAS SUSPECT CRACK. (C-CHECK RO 11/8/2022) REMOVED AND REPLACED CRACKED FLOOR SUPPORT STIFFENER AT FS 280 APPROX RBL 11.0 UNDER FLOOR FWD SIDE WITH NEW PN 600-34017-724 PO # T-68095 PERSDR SWIA202266766None · crackedFS 280 FWD FLOOR SUPPORT HAS CRACKS AT UPPER RADIUS AT LBL 9.0 AND RBL 9.0 (C-CHECK RO 11/8/2022) REMOVED AND INSTALLED NEW FLOOR SUPPORT ANGLE P/N 600-34017-351 REF CRJ 200 SRM 51-42-06 / BOMBARDIER DWG 600-34017 REV AD. COMPLIED WITH 51-900-1003-SKSDR JJBA20220930044Shear Tie · crackedCRACK FOUND ON LH SHEAR CLIP FR 58 BTW STR 15L-16L. CRACK FOUND ON LH SHEAR CLIP AT FR 58 BTW STR 15L-16L. SHEAR CLIP REPLACED AT FR 58 BTW STR 15L-16LSDR JJBA20220930043Shear Tie · crackedCRACK FOUND ON LH SHEAR CLIP AT FR 66 BTW STR 6L-7L IN RF1 AREA. CRACK FOUND ON LH SHEAR CLIP AT FR 66 BTW STR 6L-7L IN RF1 AREA. SHEAR CLIP FABRICATED WITH AN ALTERNATE MATERIAL. LH SIDE AT FR 66 BTW STR 6L-7L FABRICATED SHEAR CLIP INSTALLED.SDR JJBA20220930042Shear Tie · crackedSUSPECTED CRACK FOUND ON LH SHEAR CLIP AT FR 72 BTW STR 7L-10L IN RF1 AREA. SUSPECTED CRACK FOUND ON LH SHEAR CLIP AT FR 72 BTW STR 7L-10L IN RF1 AREASDR DALA2022092106233None · noneERA 602195-14AD ISSUED FOR WASTE BOX CORROSION FOUND DURING ACCOMPLISHMENT OF DAL WC 5327-01014. FOLLOW ON ACTION IS REQUIRED. ACCOMPLISH SECTION II EVERY 850 FH AFTER SECTION I ACCOMPLISHMENT UNTIL SECTION III ACCOMPLISHMENT. ACCOMPLISH SECTION III PERMANENT SDR SWIA202266762None · corrodedRBL 46 TO RBL27 FLOOR STRAP CORRODED AT FS 559.0 (C-CHECK RO 11/8/2022) REMOVED AND REPLACED CORRODED FLOORSTRAP WITH NEW AT FS 559.0 RBL 46 - RBL 27 REF BOMBARDIER DWG 601R31025 REV N / CRJ 200 SRM 51-42-06, LEAK CHECK GOOD. / COMPLIED WITH SKYWEST TASSDR SWIA202266761None · corrodedFLOOR STRAP CORRODED FROM LBL 46 TO LBL 27 AT FS 559.0 (C-CHECK RO 11/8/2022) REMOVED AND REPLACED CORRODED FLOORSTRAP WITH NEW AT FS 559.0 LBL 46 - LBL 27 REF BOMBARDIER DWG 601R31025 REV N / CRJ 200 SRM 51-42-06, LEAK CHECK GOOD. / COMPLIED WITH SKYWESDR SWIA202266760None · corrodedLH PRESSURE FLOOR SILL CORRODED FROM FS 409+128 TO FS 559.0 (C-CHECK RO 11/8/2022) COMPLIED WITH REO 601R-53-41-666 REV -C DATED 2012-11-06 ON LH PRESSURE FLOOR SILL BETWEEN FS 409+128 AND FS 559.00, COMPLIED WITH 51-900-1003-SKY.SEE CONTINUATION CARD SDR DALA2022091306067None · noneWASTE SERVICE DOOR 146BR HAS SEALANT MISSING AND CORROSION VISIBLE AT BOTH HINGE FITTING TO DOOR ATTACH POINTS.-M- REF WORK CARD 5327-01014-01- AD 2021-13-20. SCEPTRE LOG PAGE ENTERED FOR SDR REPORTING. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 022-0001:5327-0SDR SWIA202266585None · corrodedLH SIDE SILL RETAINER PN: SH670-36172-3 IS CORRODED. (C-CHECK RO 10/1/2022) REMOVED AND REPLACED L/H SIDE SILL RETAINER PN SH670-36172-3 PER CRJ 900 SRM 51-40-06-001-001-A01 AND CRJ 900 SRM 51-40-13-001-001-A01.SDR SWAA2022100652924Seat Track · damagedPAX CABIN SEAT TRACK AT STA 727B AND LBL-24.75 FASTENER LOCATION 'B' WITH HEAD SHEARED (SEE TTG8Q0038RHG) / [01] REMOVED FASTENER AT STA# 727B LBL 24.75 P0SITION 'B' AS PER B-737-700 SRM # 51-40-02;[02] PERFORMED HFEC ROTO INSP ON FASTENER OPEN HOLE; IAW B 737SDR DALA2022090705970None · noneERA 602016-14AD ISSUED FOR WASTE BOX CORROSION FOUND DURING ACCO MPLISHMENT OF DAL WC 5327-01014. FOLLOW ON ACTION IS REQUIRED. ERA 602016-14AD ISSUED AND IS CURRENT. NO DEVIATIONS ALLOWED. FOLLOW ON ACTION REQ. ACCOMPLISH SECT. II @ EVERY 850FH AFTER SE CT.I.SDR FDEA202209032161Shear Tie · crackedCTR CARGO, STA. 1601 HAS A SHEAR CLIP CRACKED FROM LOG 49L TO 50R. REPAIRED SHEAR CLIP AT CTR CARGO, STA. 1601 FROM LOG 49L TO 50R PER SRM 53-00-06-2R FIG 202. ORIG SUB DATE: 9/6/2022SDR SWAA2022100545337Intercostal · crackedCRACKED INTERCOSTAL AT PASSENGER CABIN BS380+14 BL0 WL208. / [01] REQUIRE NDI TO VERIFY FOR CRACK;[02] HFEC INSPECTED SUSPECTED CRACKED AREA IAW 737 NDTM PART 6 51-00-00 PROCEDURE 23.<BR>CRACKS NOTED TO BE .4' AT AREA MARKED.<BR>EQUIP USED:<BR>-NORTEC 600 ID: SDR SWIA202266829None · corroded*MULTIPLE SPOTS OF CORROSION AT R/H FLOOR SILL BETWEEN FS559.00-FS559.00+16 (MARKED) (C-CHECK RO 11/10/2022) REMOVED AND INSTALLED NEW INTERCOSTAL AT R/H FLOOR SILL BETWEEN FS559.00-FS559.00+16. REF CRJ 200 SRM 51-42-21, CRJ 200 SRM 51-42-06 AND DWG NO SDR SWIA202266824None · corrodedR/H SIDE PRESSURE FLOOR SILL HAS AREAS OF CORROSION FROM FS 409+128 TO FS 559.0 (C-CHECK RO 11/10/2022) EVALUATED AND BLENDED AREA, FOUND TO BE WITHIN LIMITS. REF. REO 601R-53-41-3077 REV. -- DATED: 2022-10-03 STEPS 1-7. COMPLIED WITH SKYWEST TASK CARDSDR SWIA202266823None · corrodedL/H SIDE INSIDE PRESSURE FLOOR SILL FROM FS 409+128 TO FS 559.0 HAS AREAS OF CORROSION (C-CHECK RO 11/10/2022) BLENDED CORROSION WITHIN LIMITS ON L/H PRESSURE FLOOR SILL FROM FS 409+128 TO FS 559.0 REF REO 601R-53-41-666 REV. -C DATED 2012-11-06, AND RESDR DALA2022090205896None · noneLAV SERVICE PANEL DOOR HAS AREAS OF CORROSION AROUND BOTH HINGE AND BOTH LATCHES. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 053-0001:5327-01014-01 /001 00058 COMPLIED WITH PRI 601705-14 REVISION 0, 1, 2, 3, 4 AND ER/A 601705-14 REVISION ORIGINAL.SUMMARY SEE NRSDR DALA2022083005811None · noneER/A 601705-14AD ISSUED FOR CORROSION AROUND THE WASTE BOX DURING WKCD 5327-01014. FOLLOW ON ACTION IS REQUIRED. ACCOMPLISH SECTION II REPEAT INSPECTIONS EVERY 850FH FOLLOWING THE ACCOMPLISHMENT OF SECTION I. ACCOMPLISH SECTION III PERMANENT REPAIR WITHIN 8500SDR SWAA2022091546986None · corrodedCORROSION CARGO TRACK-TIE BS794 PLUS 11INCH RBL13 WL159 AT AFT CARGO COMPARTMENT 2022-452190 / [01] TOOL USED DIGITAL CALIPER P/N: 500-196-30; S/N: A21033526; DUE DATE : 18-OCT-22;[02] REPAIRED CARGO TRACK-TIE LOCATED ON RBL 13 WL 159 BTW BS 747 TO BS 887 IAW SDR DALA2022091606165None · noneER/A 601449-14AD ISSUED FOR CORROSION AROUND THE WASTE BOX. FOLLOW ON ACTION IS REQUIRED. ACCOMPLISH SECTION II REPEAT INSPECTIONS EVERY 850FH FOLLOWING THE ACCOMPLISHMENT OF SECTION I. ACCOMPLISH SECTION III PERMANENT REPAIR WITHIN 8500FH FOLLOWING THE ACCOMPSDR DALA2022081805610None · noneLAV PAN CORROSION AROUND LIP OFF PAN. "M". SCEPTRE LOG PAGE ENTERED FOR SDR REPORTING. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 039-0001:5327-01014-01/004 00176 REPAIRED PER PRI 601355-14 REV 0, REV 1. REV 2, REV 3, REV 4 AND ER/A 601355-14AD REV ORIGINAL SECSDR SWIA202266503None · corrodedRH PRESSURE FLOOR SILL HAS SPOTS OF CORROSION BETWEEN FS424.00 TO FS559.00 (C-CHECK RO 9/12/2022) REMOVED CORROSION FROM R/H PRESSURE FLOOR SILL . REF: CRJ-200 S.R.M.51-21-06. FOUND ALL BELNDS TO BE WITH IN LIMITS. RECEIVED AND COMPLIED WITH ALL STEPS SDR SWIA202266502None · corrodedLH PRESSURE FLOOR SUPPORT PLATE (TOP STRAP) AT FS559 BETWEEN OB FUSELAGE SILL AND APPROXIMATE LBL 27.00 CORRODED (C-CHECK RO 9/12/2022) REMOVED CORROSION FROM FLOOR SUPPORT PLATE (TOP STRAP) AT F.S.559 BETWEEN PRESSURE FLOOR SILL AND LBL 27. REF: CRJ-2SDR DALA2022081805611None · noneER/A 601355-14 ISSUED FOR CORROSION AROUND THE WASTE BOX. FOLLOW ON ACTION IS REQUIRED. ACCOMPLISH SECTION II REPEAT INSPECTIONS EVERY 850FH FOLLOWING THE ACCOMPLISHMENT OF SECTION I. ACCOMPLISH SECTION III PERMANENT REPAIR WITHIN 8500FH FOLLOWING THE ACCOMPLISDR SWIA202266532None · corrodedLH FLOOR SILL IS CORRODED ON TOP AND BOTTOM SURFACE BETWEEN FS349 AND FS409. (C-CHECK RO 9/28/2022) REPAIRED LH FLOOR SILL TOP AND BOTTOM SURFACE BETWEEN FS349 AND FS409. IAW MHIRJ REO 601R-53-21-3564 REV -- DATED 2022-09-08 COMPLETED SYY TRACK TASK CASDR YENA2022081600803Frame · crackedDURING HEAVY MAINTENANCE: CRACK INDICATION ON FRAME 2 WINDSHIELD CENTER POST LOWER NODE AREA CONTINUITY FITTING LH SIDE, CRACK LENGTH IS 0.200 INCH APROXIN COCKPIT(1EA); REMOVED AND REPLACED CONTINUITY FITTING LH SIDE ON FRAME 2 WINDSHIELD CENTER POST LOWER NOSDR SWIA202266527None · corrodedRH FLOOR SILL PLATE IS CORRDED BETWEEN FS529 AND FS544 (C-CHECK RO 9/28/2022) REPAIRED RH FLOOR SILL IAW REO 601R-53-41-0666 REV. C, DATED 2012-11-06. MAJOR REPAIR TASK CARD 51-900-1003-SKY AND FORM M-337 COMPLETED AND ATTACHED. NO WEIGHT CHANGE NOTED SSDR A6WA202208108268None · nonePAX DOOR HINGE, FUSELAGE SIDE, HOLES ARE WORN/OUT OF ROUND ON SEVERAL LOBES, PIN IN EXCESSIVELY LOOSE WHEN INSTALLED ****AIRCRAFT REMOVED FROM SERVICE **** INSTALLED NEW PAX DOOR HINGE (FUSELAGE SIDE) PN 600-31529-15 PO# 7835-00002 AND TOUCHED UP REPAIR AREASDR A6WA202208098266Seal · gougedUPPER SEAL SURROUND FOR THE SERVICE DOOR HAS SEVERAL GOUGES ****AIRCRAFT REMOVED FROM SERVICE **** INSTALLED NEW MID UPPER AND UPPER FWD SERVICE DOOR SURROUND IAW CRJ200 SRM 51-42-06 AND DWG 601R38340 REV BSDR CALA2022081002034Shear Web · corrodedAFT SHEAR WEB CORRODED @ FR70 A3NB-53-3-622 GENERATED BY V079881 AT HAECO LCQ PER NR 9296340 (26340) REMOVED AND REPLACED RH SHEAR WEB IAW A319 SRM 51-72-11-001 PERF ORMED BY V915851 INSP BY N078570SDR DALA2022080905438None · noneREMOVE AND REPLACE WASTE BOX PAN REF A220 ABC DWG C01342100 REV - W AND ABC DWG C011342957 REV - E. ER/A 601047-14 REV ORIGINAL. PRI 601047-14 REV 0,1,2,3,4,5. REMOVED AND REPLACED WASTE BOX PAN REF A220 ABC DWG C01342100 REV - W AND ABC DWG C011342957 REV - ESDR DALA2022080905437None · noneREMOVE AND REPLACE WASTE BOX PAN REF A220 ABC DWG C01342100 REV - W AND ABC DWG C011342957 REV - E. ER/A 601047-14 REV ORIGINAL. REMOVED AND REPLACED WASTE BOX PAN REF A220 ABC DWG C01342100 REV - W AND ABC DWG C011342957 REV - E. ER/A 601047-14 REV ORIGINAL. SDR DALA2022080905439None · noneACCOMPLISH PRI 601047-14 REV 0, REV 1, REV 2, REV 3, REV 4, REV 5 AND ER/A 601047-14AD REV ORIGINAL. DUE TO LAV SERVICE PANEL CORROSION. ACCOMPLISHED PRI 601047-14 REV 0, REV 1, REV 2, REV 3, REV 4, REV 5 AND ER/A 601047-14AD REV ORIGINAL. SEE EMPOWER WORKORDESDR DALA2022080505376None · noneERA 601047-14AD SECTION I ACCOMPLISHED IN MSP DURING C CHECK.FO LLOW ON ACTION IS REQUIRED. ACCOMPLISH ERA 601047-14AD SECTION II EVERY 850 FH AFTER SECTION I UNTIL SECTION III. SECTION I REPAIR IS TIME LIMITED TO 8500 F H. THIS RESTRICTION IS TRACKED PER SECTSDR SWAA2022090636045Angle · crackedCRACK ANGLE FLOOR STRUCTURE LOCATED BS 695 RBL 24.75 AND WL 208.1 AT PASSENGER CABIN 2022-410203 / [01] TOOL USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 112031023 DUE DATE: 01-FEB-23. TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 112820025 DUE DATE: 01SDR SWIA202266471None · corrodedLH PRESSURE FLOOR SILL HAS CORROSION FROM FS424.00 TO FS559.00 (C-CHECK RO 9/12/2022) REMOVED CORROSION FROM LH PRESSURE FLOOR SILL AT FS424.00 TO FS559.00 REF CRJ200 SRM 51-21-06. FOUND TO BE OUT OF LIMITS AT CERTAIN LOCATIONS. RECEIVED AND COMPLIED WISDR SWAA2022082333003Track · crackedCRACK TRACK RBBL 13.84 LOCATED ON BS 767 AT AFT CARGO COMPARTMENT 2022-375996 / [01] TOOL USED EDDY CURRENT FLAW DETECTOR P/N: NORTEC600D; S/N: 210136503; DUE DATE: 11-APR-23.;[02] TOOL USED DIGITAL CALIPER P/N: 500-197-30; S/N: A21147750; DUE DATE: 29-JUN-23;SDR SWAA2022082231785Track · corrodedCORROSION ON TRACK AT AFT CARGO BAY RBL13 BS727+10 - BS727B; BS727D; BS787; BS787+12. / [01] REMOVED MULTIPLE CORROSION AREAS ON THE TIE DOWN TRACK FROM BS 727+10 - BS787+12 RBL 13 IAW SRM 51-10-02. MAX. MATERIAL REMOVED IN AREA OF 1.3'X0.9'X0.04'DEPTH FROM ANSDR SWAA2022082231817Rail · corrodedCORROSION ON RAIL AT AFT CARGO BAY BS767+6 LBL12. / [01] CORRODED SPLICE REPAIR ; ON UPPER FLANGE AT A JOGGLE; LOCATED AT AFT CARGO BAY BS 767 + 6 LBL12 NOT HAVE ENTRIES IN SRM BY ALLOWABLE DAMAGE MUST BE REPAIR BY REPLACEMENT IAW SRM 51-10-02 ITEM 9.C.;[02] VSDR SWIA202266318None · elongatedRH FLOOR SILL HAS ELONGATED HOLE FWD OF FS295.00 (C-CHECK RO 8/15/2022) COMPLIED WITH REO REPAIR 601R-53-21-3558 REV--, DATED: 2022-08-01. TASK CARD 51-900-1003-SKY COMPLIED WITH.SDR U2RA2022072800033Seat Track · damagedSEAT TRACK (P/N: 65B38272-1) ON CABIN MAIN DECK STA 1481 -1766, LBL 11.33 WAS FOUND BROKEN, THE PERMANENT REPAIR WAS ACCOMPLISHED IN ACCORDANCE WITH FLIGHT VEHICLES CONSULTING, LNC'S ENGINEERING ORDER 22089-9, REV LR, WHICH WAS APPROVED BY FAA FORM 8110-3 SDR U2RA2022072800028Seat Track · damagedSEAT TRACK ON M/D STA 1265-1480, RBL 11.33 WAS FOUND BROKEN AND NO APPLICABLE REPAIR IN 747-400SF SRM. THE PERMANENT REPAIR WAS ACCOMPLISHED IN ACCORDANCE WITH FLIGHT VEHICLES CONSULTING, INC'S ENGINEERING ORDER 22089-4, REV LR, WHICH WAS APPROVED BY FAA FORMSDR DALA2022071904977Bracket · corrodedREF AMDS 5327-01014-01, AD 2021-13-20, LAV SERVICE ACCESS DOOR 146BR, BONDING WIRE BRACKET HAS CORROSION. REPAIR CORROSION PRIOR TO FURTHER FLIGHT. SUMMARY SEE NR FOR ADDITIONAL INFORMATION 026-0001:5327-01014-01 /001 00089 REPLACED BONDING WIRE REF A220 AMP 5SDR DALA2022070904803Panel · crackedAIRCRAFT 0664, CRACK ON LH SIDE PANEL BTW STA 1540 TO STA 1560 AT AFT CARGO COMP. CORRECTIVE ACTION: CRACK ON LH SIDE PANEL BTW STA 1540 TO STA 1560 AT AFT CARGO COMP WAS REPAIRED PER B757-200 SRM 51-70-13- 0G. (2312294)SDR SWIA202266153None · corrodedAFT WET AREA HAS CORROSION ON FLOOR SPLICE AT FR 90-91 RH SIDE. (C-CHECK RO 7/23/2022) REMOVED AND REPLACED FLOOR SPLICE AT FR 90-91 RH SIDE REF EMB 170/175 SRM 51-40-08. REF CONINUATION CARD FOR CORRECTIVE ACTION DETAILS.SDR SWIA202266206None · shearedFLOOR SUPPORT BEAM FS280-FS 295 NEAR FWD O/B GALLEY MOUNT FITTING HAS SHEARED RIVET WITH CRACKS AROUND FASTENER HOLE (C-CHECK RO 7/26/2022) COMPLIED WITH MHIRJ REO 601R-53-21-3556 REV-- DATED: 2022-07-09. COMPLETED SKYCARD 51-900-1003-SKY AND COMPLETED
Back to JASC 5322