JASC 5322

Service difficulty reports · 12,776

Reports filed under 5322 · Fuselage Internal Mounting Structure, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '5322'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SWIA202265412None · corrodedRBL9 FLOOR BEAM IS CORRODED AT F.S. 416. (C-CHECK RO 4/20/2022) REMOVED AND REPLACED PRESSURE FLOOR BEAM CAP IAW REO 601R-53-41-3024 REV -- DATED 2022-02-21. COMPLETED SKYWEST TASK CARD 51-900-1003-SKY AND ATTACHED COMPLETED FORM 337. WEIGHT CHANGE +3.9Feb 15, 2022 · N479CA · Cndair CL6002B19SDR SWIA202265410None · corrodedLBL9 FLOOR BEAM IS CORRODED BETWEEN F.S. 559.0+16 TO F.S. 559.0+32. (C-CHECK RO 4/20/2022) COMPLIED WITH CRJ 200 SRM 53-00-43 REPAIR 1 ON LBL#9 BETWEEN 559.00+16- 559.00+43. ATTACHED COMPLETED SKYCARD 51-900-1003- SKY , COMPLETED 337 ATTACHED.TOTAL WEFeb 15, 2022 · N479CA · Cndair CL6002B19SDR SWIA202264902None · corrodedR/H PRESSURE FLOOR SILL HAS AREAS OF CORROSION AT F.S. 519.00 AND 522.00. (C CHECK RO 3/11/2022) REPAIRED R/H PRESSURE FLOOR SILL I.A.W. BOMBARDIER REO 601R-53-41-666 REV.C, DATED 2012-11-06, MHIRJ REO 601R-53-41-3008 REV.--, DATED 2022-01-26 AND MHIRJ REOFeb 15, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264901None · corrodedR/H PRESSURE FLOOR SILL PANEL HAS AREAS OF CORROSION AT F.S. 501.00 AND F.S. 507.00. (C CHECK RO 3/11/2022) REPAIRED R/H PRESSURE FLOOR SILL I.A.W. BOMBARDIER REO 601R-53-41-666 REV.C, DATED 2012-11-06, MHIRJ REO 601R-53-41-3008 REV.--, DATED 2022-01-26 ANFeb 15, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264900None · corrodedR/H PRESSURE FLOOR SILL PANEL HAS AREAS OF CORROSION BETWEEN F.S. 524.00 AND 544.00. (C CHECK RO 3/11/2022) REPAIRED R/H PRESSURE FLOOR SILL I.A.W. BOMBARDIER REO 601R-53-41-666 REV.C, DATED 2012/11/06, MHIRJ REO 601R-53-41-3006 REV.--, DATED 2022/02/26 ANFeb 14, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264899None · corrodedL/H PRESSURE FLOOR SILL PANEL HAS AREAS OF CORROSION BETWEEN F.S. 439.00 AND 449.85. (C CHECK RO 3/11/2022) REPAIRED L/H PRESSURE FLOOR SILL I.A.W. BOMBARDIER REO 601R-53-41-666 REV.C, DATED 2012-11-06, MHIRJ REO 601R-53-41-3010 REV.--, DATED 2022-01-26 ANFeb 14, 2022 · N877AS · Cndair CL6002B19SDR SWIA202264898None · corrodedL/H PRESSURE FLOOR SILL PANEL HAS AREAS OF CORROSION BETWEEN F.S. 424.00 AND F.S. 439.00 (C CHECK RO 3/11/2022) .REPAIRED L/H PRESSURE FLOOR SILL I.A.W. BOMBARDIER REO 601R-53-41-666 REV.C, DATED 2012-11-06, MHIRJ REO 601R-53-41-3010 REV.--, DATED 2022-01-Feb 14, 2022 · N877AS · Cndair CL6002B19SDR SWIA202265486None · corrodedFLOORBEAM AT RBL9 APPROX. FS 661+83.00 IS CORRODED. MARKED. (C-CHECK RO 4/25/2022) REPAIRED FLOORBEAM AT RBL9, SF661.00+83.00 PER CRJ900 SRM 53-00-41-201-001-A03, FIGURE 53-00-41-995-828. SEE CONTINUATION CARD FOR DETAILS. COMPLIED WITH TASK CARD 51-Feb 12, 2022 · N549CA · Cndair CL6002D24SDR SWIA202265463None · corroded*CORROSION ON FS280 FLOOR PANEL SUPPORT ANGLE (MARKED) (C-CHECK RO 4/25/2022) BLENDED CORROSION FROM FLOOR SUPPORT ANGLE AT FS280 PER REF CRJ 900 SRM 51-21-06-001-001-A01. REPLACED DAMAGED FLOOR SUPPORT ANGLE BY NEW ONE PER DWG # CC670-34010 REV -K, CRJFeb 10, 2022 · N549CA · Cndair CL6002D24SDR N6WA2022021101Seal Plate · crackedAFT CARGO COMAPRTMENT DOOR CUTOUT, AFT DOOR TRACK SUPPORT CHANNEL IS CRACKED.R&R UPPER SEAL PLATE IAW CRJ 700 SRM 51-41-02Feb 10, 2022 · N539GJ · Cndair CL600*SDR SWIA202265457None · corroded*IN MAIN CABIN, AT AND BELOW FLOOR, AT APPROXIMATELY BETWEEN FS319 & FS349 AND NEAR STR17R, FLOOR SUPPORT AT GALLEY DOOR HAS MULTIPLE AREAS OF CORROSION. (MARKED). (C-CHECK RO 4/25/2022) REMOVED AND REPLACED FLOOR SUPPORT ANGLE IN MAIN CABIN AT FLOOR Feb 9, 2022 · N549CA · Cndair CL6002D24SDR SWIA202265456None · corroded*IN MAIN CABIN, AT AND BELOW FLOOR, AT FS288 AND APPROXIMATELY RBL14, BETWEEN 2 INTERCOSTALS, SUPPORT BRACKET HAS AEAS OF CORROSION. (MARKED). (C-CHECK RO 4/25/2022) REPLACED GALLEY 1 ANCHOR FITTING AT FS288.00 RBL14 PER CRJ900 SRM 51-42-20-001-001-A0Feb 9, 2022 · N549CA · Cndair CL6002D24SDR SWIA202264959None · corrodedCORROSION FOUND ON LBL9.0 FLOOR BEAM CAP BETWEEN FS1025 AND FS1035. (C-CHECK RO 3/11/2022) REMOVED AND REPLACED CORRODED FLOOR BEAM SECTION WITH NEW FABRICATED FLOOR BEAM SECTION AT LBL9.0 BETWEEN FS1025.00 AND FS1035.00 WITH ALL NEW HARDWARE PER CRJ700Feb 9, 2022 · N732SK · Cndair CL600*SDR SWIA202264957None · corrodedCORROSION FOUND ON RBL9.0 FLOOR BEAM CAP BETWEEN FS1025 AND FS1035. (C-CHECK RO 3/11/2022) REMOVED AND REPLACED CORRODED FLOOR BEAM SECTION WITH NEW FABRICATED FLOOR BEAM SECTION AT RBL9.0 BETWEEN FS1025.00 AND FS1035.00 WITH ALL NEW HARDWARE PER CRJ700Feb 9, 2022 · N732SK · Cndair CL6002C10SDR A6WA202202088160Fitting · corrodedPAX DOOR FORWARD COUNTER BALANCE ANCHOR FITTING ASSEMBLY AT FS310.00 IS CORRODED. ***AIRCRAFT REMOVED FROM SERVICE **** REMOVED AND REPLACED PAX DOOR FORWARD COUNTER BALANCE ANCHOR FITTING ASSEMBLY PN 601R38075-4 AT FS310.00. RESTORED PROTECTIVE FINISH. ALL WFeb 8, 2022 · N436AW · Cndair CL6002B19SDR SWIA202264948None · crackedLH FLOOR SUPPORT ANGLE FOUND TO BE CRACKED AT LBL 9.0 JUST FWD FS 280. (C-CHECK RO 3/11/2022) DISCREPANCY LOCATION IS LBL 12 THERE IS NO STRUCTURE LOCATED AT LBL9 JUST FWD OF FS280 / INSTALLED NEW LH FLOOR SUPPORT ANGLE LBL 12. REF CRJ 700 CRJ700 SRM Feb 6, 2022 · N732SK · Cndair CL6002C10SDR SWIA202264947None · crackedRH FLOOR SUPPORT ANGLE FOUND TO BE CRACKED AT RBL 12.0 AT FS 280 JUST FWD , (C-CHECK RO 3/11/2022) REMOVED AND REPLACED R/H FLOOR SUPPORT ANGLE ASSY AT RBL 12.0 FWD OF FS280 AND RESTORED FINISH. REF CRJ700 SRM 51-42-06-001-001-A01 AND CRJ700 SRM 53-11-4Feb 6, 2022 · N732SK · Cndair CL6002C10SDR SWIA202265046None · cracked: DURING FLOOR SUPPORT ANGLE REMOVAL FROM FLOOR BEAM AT FS280, LBL9-RBL9, IT WAS FOUND FLOOR BEAM VERTICAL ATTACH ANGLE CRACKED AT FS280.00, LBL9 (C-CHECK RO 3/14/2022) REMOVED DAMAGED FLOOR BEAM VERTICAL ATTACH ANGLE AT FS280.00, LBL9 AND REPLACED BY A Feb 4, 2022 · N854AS · Cndair CL6002B19SDR SWIA202264574None · corrodedFWD WET AREA FR12 TO FR14 R/H SIDE 3 HOLE SILL IS CORRODED AS MARKED (C CHECK RO 02/21/2022) REMOVED AND REPLACED FWD WET AREA FR12 TO FR14 R/H SIDE 3 HOLE SILL REF EMB SRM 51-40-08.Feb 3, 2022 · N241SY · Emb EMB110*SDR SWIA202264571None · brokenFR86 RH SIDE FLOOR BOARD SUPPORT BROKEN OFF AS MARKED (C CHECK RO 02/21/2022) REMOVED AND INSTALLED NEW FRAME 86 RH SIDE FLOOR BOARD SUPPORT REF SRM 51-40-08. APPLIED SURFACE PROTECTION REF SRM 51-23-06 ANS CIC REF CPM 51-25-00.Feb 3, 2022 · N241SY · Emb ERJ170200LRSDR SWIA202264570None · brokenFR85 LH SIDE FLOORBOARD SUPPORT IS BROKEN AS MARKED (C CHECK RO 02/21/2022) REMOVED AND INSTALLED NEW FRAME 85 LH SIDE FLOOR BOARD SUPPORT REF SRM 51-40-08. APPLIED SURFACE PROTECTION REF SRM 51-23-06 AND APPLIED CIC REF CPM 51-25-00Feb 3, 2022 · N241SY · Emb ERJ170200LRSDR SWAA2022030366897Track · corrodedCORROSION ON TRACK AT ACB BS727A RBL13. MARKED. / [01] EVALUATED CORROSION AT BS 727A RBL 13 WL 156; FOUND 0.020 REMOVED FROM ORIG 0.071 IN 1'X1' AREAS FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ATS 2473; TRACK TO BE REPLACED ON CUSFeb 2, 2022 · N469WN · Boeing 737*SDR R61A2022021400142Shear Tie · corrodedSHEAR CLIP CORRODED ON FRAME 17 FROM STRINGERS 26R TO 25R EVALUATED SHEAR CLIP AT STGR 26R-25R REF. EMB SRM 51-10-02. 100% THICKNESS REDUCTION AT DEEPEST AREAS. REMOVED AND REPLACED SHEAR CLIP REF. EMB SRM 51-40-08Feb 2, 2022 · N826MD · Emb ERJ170200LRSDR SWIA202264301None · corrodedAFT WET AREA- LH FLOOR BEAM 2" FWD FR 86-89 ; LBL12" HAS CORROSION; MARKED. (C-CHECK RO 2/15/2022) REMOVED AND REPLACED LH FLOOR BEAM FR 86-89 LBL 12 REF ERJ 175 SRM 51-40-08 SEE CONTINUE CARD FOR WORK PERFORMED.Jan 28, 2022 · N242SY · Emb ERJ170200LRSDR SWAA2022021764319Seat Track · damagedF/OS AFT SEAT TRACKS ARE OUT OF LIMITS. (2EACH) / [01] REMOVED F/O?S AFT SEAT TRACKS (2 EACH) PER AMM 25-11-11.;[02] INSTALLED SERVICEABLE AFT F/OS SEAT TRACKS PER AMM 25-11-11;[03] C/W INSPECTIONJan 26, 2022 · N8312C · Boeing 7378H4SDR SWAA2022021764321Seat Track · damagedCAPTAINS AFT SEAT TRACKS ARE OUT OF LIMITS. (2EACH) / [01] REMOVED CAPTAIN?S AFT SEAT TRACKS (2 EACH) PER AMM 25-11-11.;[02] INSTALLED SERVICEABLE AFT CAPT SEAT TRACKS PER AMM 25-11-11;[03] C/W INSPECTIONJan 26, 2022 · N8312C · Boeing 7378H4SDR V0XD20220126001Tcas System · corrodedTCAS ANTENNA DOUBLER CORRODED OUT OF LIMITS. CORRECTIVE ACTION: REMOVED AND REPLACED CORRODED TCAS ANTENNA DOUBLER IAW CRJ 700 SRM 51-42-06-001. WORK PERFORMED ON AVMAX WO 80974 WC1144.Jan 26, 2022 · N525A · Cndair CL6002C10SDR YENA2022031100159Frame · crackedDURING HEAVY MAINTENANCE, CRACK INDICATION ON FRAME 2 WINDSHIELD CENTER POST LOWER NODE CONTINUITY FITTING RH SIDE, CRACK LENGTH IS 0.200 INCH IN COCKPIT (1 EA); REF AEROMAN N/R 2021-491505, ACCOMPLISH MODIFICATION/REPAIR IN ACCORDANCE WITH AEROMAN 53-0549-21Jan 23, 2022 · N505JB · Airbus A320232SDR YENA2022031100158Frame · crackedDURING HEAVY MAINTENANCE, CRACK INDICATION ON FRAME 2 WINDSHIELD CENTER POST LOWER NODE CONTINUITY FITTING LH SIDE, CRACK LENGTH IS 0.200 INCH IN COCKPIT (1 EA); REF AEROMAN N/R 2021-491504, ACCOMPLISHED THE REPAIR IN ACCORDANCE WITH AEROMAN EA 53-0564-21 REVJan 23, 2022 · N505JB · Airbus A320232SDR SWIA202265191None · corroded*IN MAIN CABIN, ON PRESSURE FLOOR SUPPORT BEAM, FROM APPROXIMATELY 409+128 TO FS559, AND RBL9, HAS CORROSION ON MULTIPLE AREAS OF UPPER SURFACE. (MARKED) (C-CHECK RO 3-25-22) PERFORMED REPAIR ON FLOOR SUPPORT BEAM, FROM APPROXIMATELY 409+128 TO FS559.00Jan 20, 2022 · N875AS · Cndair CL6002B19SDR SWIA202265189None · corroded*IN MAIN CABIN, ON PRESSURE FLOOR SUPPORT BEAM, FROM APPROXIMATELY 409+128 TO FS559, AND LBL9, HAS CORROSION ON MULTIPLE AREAS OF UPPER SURFACE. (MARKED) (C-CHECK RO 3-25-22) PERFORMED REPAIR ON FLOOR SUPPORT BEAM, FROM APPROXIMATELY 409+128 TO FS559.00Jan 20, 2022 · N875AS · Cndair CL6002B19SDR SWIA202265187None · corroded*IN MAIN CABIN, L/H PRESSURE FLOOR SILL MEMBER, FROM APPROXIMATELY 409+128 TO FS559, NEAR STR17L, HAS MULTIPLE AREAS OF CORROSION. (MARKED) (C-CHECK RO 3-25-22) REMOVED CORROSION FROM L/H PRESSURE FLOOR SILL FS 409+128-FS 559 STR 17L PER CRJ 200 SRM 51-2Jan 20, 2022 · N875AS · Cndair CL6002B19SDR SWIA202265185None · corroded*IN MAIN CABIN, AT APPROXIMATELY FS409+30 TO FS409+128, AND NEAR LBL6-LBL8, FLOOR BEAM HAS MULTIPLE AREAS OF CORROSION. (MARKED) (C-CHECK RO 3-25-22) REMOVED AND REPLACED MAIN CABIN FLOOR BEAM CAP AT APPROXIMATELY FS409+30 TO FS409+128, AND NEAR LBL6-LBLJan 20, 2022 · N875AS · Cndair CL6002B19SDR SWIA202265184None · corroded*IN MAIN CABIN, ON FLOOR BEAM AT APPROXIMATELY FS409+16 TO FS409+128, AND BETWEEN RBL6 TO RBL8, FLOOR BEAM HAS MULTIPLE AREAS OF CORROSION. (MARKED) (C-CHECK RO 3-25-22) REMOVED AND REPLACED FLOOR BEAM CAP AT FS409+16 TO FS409+128, AND BETWEEN RBL6 TJan 20, 2022 · N875AS · Cndair CL6002B19SDR SWIA202265400None · corrodedLH PRESSURE FLOOR SILL PANEL CORRODED AROUND NUTPLATES AT 5EA. LOCATIONS BETWEEN FS 499 AND FS 559. (C-CHECK RO 4/20/2022) REMOVED CORROSION FROM L/H PRESSURE FLOOR SILL FROM FS 499 TO FS 559 IAW CRJ 200 REO 601R-53-41-666 REV-C DATED 2012-11-06 AND FOUJan 19, 2022 · N479CA · Cndair CL6002B19SDR SWIA202265183None · corroded*GUSSET COMMON TO FS409 FRAME AND INTERCOSTAL AT STR25R HAS CORROSION (MARKED). (C-CHECK RO 3-25-22) REPLACED GUSSET REF DRAWING #601R31049 REV:-F, CRJ200 SRM 51-42-21-00 REV: 38B DATED: 25 NOV 2020. FOR ALL WORK ACCOMPLISHED SEE CONTINUE CARD. COMPLIED Jan 19, 2022 · N875AS · Cndair CL6002B19SDR SWIA202265181None · corroded*CORROSION ON FLOOR SILL ATTACHING ANGLE RBL 45 BETWEEN FS 605.00 €“ 621.00 (C-CHECK RO 3-25-22) REMOVED CORROSION FROM FLOOR SILL ATTACHING ANGLE RBL45 F.S.605-621.00 IAW REO 601R-53-61-4690 REV.-- DATED 2012-10-24 FOUND TO BE WITHIN LIMITS.Jan 19, 2022 · N875AS · Cndair CL6002B19SDR SWIA202265180None · corroded*CORROSION ON FLOOR SUPPORT BEAM AT FS 589.00 BETWEEN RBL 27 €“ RBL 36 (C-CHECK RO 3-25-22) REMOVED AND REPLACED WITH NEW FLOOR SUPPORT AT FS 589.00 BETWEEN RBL 27 €“ RBL 36 REF CRJ200 SRM 51-42-06 REV 38 JUL 10/2019 AND BOMBARDIER DWG 601R35031 REV -Jan 19, 2022 · N875AS · Cndair CL6002B19SDR SWIA202265179None · corroded*CORROSION ON FLOOR SUPPORT STRAP AT FS 559.00 BETWEEN RBL 9 €“ RBL 18 (C-CHECK RO 3-25-22) REMOVED CORROSION ON FLOOR SUPPORT STRAP AT FS 559.00 BETWEEN RBL 9 €“ RBL 18 IAW CRJ200 SRM 51-21-06. FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED NEW FLOOR Jan 19, 2022 · N875AS · Cndair CL6002B19SDR SWIA202265178None · corroded*CORROSION ON FLOOR BEAM RBL 9 BETWEEN FS 559.00 €“ 559.00+96 (C-CHECK RO 3-25-22) REMOVED AND REPLACED WITH NEW FABRICATED RBL9 FLOOR BEAM CAP BETWEEN FS 559.00 AND FS 574 .00 REF CRJ200 SRM 51-42-21, CRJ200 SRM 51-42-22, REO 601R-53-51-615 REV -- DATEDJan 19, 2022 · N875AS · Cndair CL6002B19SDR SWIA202265177None · corroded* THE FLOOR BEAM CAP AT RBL27 BETWEEN FS605 AND FS621 APROX HAS MULTIPLE LOCATIONS OF CORROSION. (MARKED) (C-CHECK RO 3-25-22) REPLACED FLOOR BEAM CAP AT RBL27 BETWEEN FS605 AND FS621 REF REO 601R-53-61-3778 REV -B DATE 2016-12-19 AND DRAWING 601R35031 Jan 19, 2022 · N875AS · Cndair CL6002B19SDR SWIA202265176None · corroded* THE FLOOR BEAM CAP AT RBL9 BETWEEN FS605 AND FS621 APROX HAS MULTIPLE LOCATIONS OF CORROSION. (MARKED) (C-CHECK RO 3-25-22) REMOVED AND REPLACED CORRODED FLOOR BEAM CAP AT RBL9 BETWEEN APPROX. FS605 AND FS621 WITH A SERVICEABLE UNIT REF CRJ 200 SRM 51-4Jan 19, 2022 · N875AS · Cndair CL6002B19SDR SWIA202264890None · corrodedFLOOR SILL AT PAX DOOR FWD CAP ANGEL CORRODED (C-CHECK RO 3/11/2022) REMOVED AND INSTALLED NEW PAX DOOR FLOOR SILL ANGLE FWD CAP ANGLE IAW CRJ 700 SRM 51-42-06-001-001-A01 AND DWG# SH670-31810 REV AE, COMPLIED WITH SKYWEST TASKCARD 51-900-1002-SKY.Jan 18, 2022 · N732SK · Cndair CL6002C10SDR SWIA202265397None · corrodedRH FLOOR SILL CORRODED AT APPROX FS319 (C-CHECK RO 4/20/2022) REMOVED AND REPLACED R/H FLOOR SILL IAW CRJ-200 SRM-51-42-06. COMPLETED SKYCARD TASK CARD 51-900-1003-SKY AND COMPLETED FORM 337. NO WEIGHT CHANGE.Jan 17, 2022 · N479CA · Cndair CL6002B19SDR SWIA202264859None · corroded* LH FLOOR BEAM CORRODED AND PITTED LBL27 AT APROX FS 1040.MARKED (C-CHECK RO 3/11/2022) COMPLIED WITH ALL STEPS OF CRJ700 SRM 53-00-41-201-001-A01 FLOORBEAM REPAIR, CUT AWAY DAMAGE, FABRICATED & INSTALLED REPAIR PARTS. COMPLIED WITH TASK CARD 51-900-1Jan 16, 2022 · N732SK · Cndair CL6002C10SDR SWIA202264997None · none* FLOOR BEAM INBOARD FLANGE HAS A DRILL START AT APPROXIMATELY FS357, RBL9, MARKED. (C-CHECK RO 3/14/2022) RECEIVED REO 601R-53-21-3532 REV --, DATED 2022-02-10 AND DRILLED HOLE OF 0.128 DIA. AND COUNTERSINKED HOLE ENSURING ALL DAMAGE REMOVED. WITH EDGJan 14, 2022 · N886AS · Cndair CL6002B19SDR SWIA202264848None · corrodedFS 280 CROSS BEAM FWD FLOOR SUPPORT HAS CORROSION (C-CHECK RO 3/11/2022) REMOVED AND INSTALLED NEW FWD FLOOR SUPPORT AT FS280 REF CRJ700 SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-A01 AND DWG# CC670-34010 REV-K. / COMPLIED WITH SKYWEST TASKCARD Jan 14, 2022 · N732SK · Cndair CL6002C10SDR A6WA202202218113None · damagedPAX DOOR LOWER SILL SEAL STRIKER AT FS349.00 IS DAMAGED. ***AIRCRAFT REMOVED FROM SERVICE*** REMOVED AND REPLACED PAX DOOR LOWER SILL SEAL STRIKER AT FS349.00 PN 600-31535. PERFORMED HFEC WITH NO INDICATIONS. RESTORED PROTECTIVE FINISH. ALL WORK WITHIN LIMIJan 14, 2022 · N438AW · Cndair CL6002B19SDR SWIA202264995None · corroded* L/H FLOOR SUPPORT STRAP AT FS559, LBL27-LBL36 IS CORRODED, MARKED. (C-CHECK RO 3/14/2022) REMOVED AND REPLACED L/H FS559 LBL27-LBL36 FLOOR SUPPORT STRAP PN: 601R31025-29. REF CRJ200 SRM 51-42-06 REV 38 JUL 10/19 AND DWG 601R31025 REV N. PRESSURE LEAJan 13, 2022 · N886AS · Cndair CL6002B19SDR SWIA202264994None · corroded* R/H PRESSURE FLOOR SILL ANGLE IS CORRODED IN MULTIPLE SPOTS, MARKED. (C-CHECK RO 3/14/2022) REMOVED 72EA HILITES AND 17EA RIVETS TO FOM PER CRJ 200 SRM 51-42-06-00 TO FACILITATE REMOVAL OF CORROSION ON MULTIPLE SPOTS @ RH PRESSURE FLOOR SILL ANGLE PJan 13, 2022 · N886AS · Cndair CL6002B19
Back to JASC 5322