JASC 5340
Service difficulty reports · 22,407
Reports filed under 5340 · Fuselage Main, Attach Fittings, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5340' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA201804194002Tee Fitting · corrodedCORROSION ARE CARGO DOOR CUT OUT ON TEE FITTING AT FRAME 65 AND STRINGER 16L. REMOVED AND REPLACED THE TEE FITTING IAW SRM 51-40-02 AND CPM 51-21-04.SDR A6WA201845775Fitting · crackedBATH TUB FITTING AT BS 461, OTBD SIDE OF LBL 9 IS CRACKED.SDR CALA2018041801182Fitting · corrodedL2 DOOR SILL AFT CORNER UNDER GIRT BAR FITTING HAS CORROSION. REMOVED AND REPLACED THE DOOR SILL FITTING IAW SRM 51-42-11-001, PARA E.SDR DALA2018041702521Fitting · crackedCRACKED FITTINGS AT THE RT AND LT SIDES AT AFT CABIN BULKHEAD DOOR FRAME. FITTINGS REPLACED IAW SRM 51-30-2, 51-30-5, AND 51-30-1.SDR VNAA2018041799908Attach Angle · crackedATTACH ANGLE ON THE INTERCOSTAL AT STRINGER 14R, BS 625.3 IS CRACKED IN THE RADIUS. REPLACED THE ANGLE.SDR VNAA2018041799907Attach Angle · crackedANGLE ATTACHED TO THE INTERCOSTAL AT STRINGER 14L AND BS 625.3 IS CRACKED IN THE RADIUS. REPLACED THE ANGLE.SDR SWAA201805161682Bracket · crackedAFT CARGO BAY BRACKET CRACKED AT BS 867, LBL 11. R & R THE BRACKET IAW SRM.SDR ASOA201804135105Fitting · corrodedFLOORBEAM FITTING IS CORRODED AT BS 349 AND STRINGER 18L. REMOVED AND REPLACED THE FLOORBEAM FITTING IAW SRM 51-40-11-001-001-A01, 51-42-06-001-001-A01, AND 51-42-20-001-001-A01.SDR AALA201804239063Fitting · damagedELONGATED HOLE IN THE FITTING CORNER, FRAME 68, STRINGER 23R IN THE AFT GALLEY AREA. REPLACED THE FITTING IAW SRM 51-72-11.SDR AALA201804239060Fitting · damagedELONGATED HOLE ON THE FITTING CORNER, FRAME 66, STRINGER 23R IN THE AFT GALLEY AREA. REPLACED THE FITTING IAW SRM 51-72-11, AND DRAWING D53480505.SDR AALA2018041809032Cleat · corrodedCORRODED CLEAT AT FRAME 30 ABOVE STRINGER 41R. REPLACED THE CLEAT IAW SRM 51-42-11.SDR AALA2018041809031Cleat · corrodedCORRODED CLEAT AT FRAME 30 BELOW STRINGER 41R. REPLACED THE CLEAT IAW SRM 51-42-11.SDR AALA2018041809030Cleat · corrodedCORRODED CLEAT AT FRAME 32 BELOW STRINGER 41R. REPLACED THE CLEAT IAW SRM 51-42-11.SDR AALA2018041809029Cleat · corrodedCORRODED CLEAT AT FRAME 32 ABOVE STRINGER 41R. REPLACED THE CLEAT IAW SRM 51-42-11.SDR SIMA20180413004Tee Fitting · corrodedCORROSION ON THE CARGO DOOR CUT OUT TEE FITTING, LOCATED AT FRAME 68, STRINGER 16L. REMOVED AND REPLACED THE TEE FITTING IAW SRM 51-10-03, 51-40-20, CPM 51-21-04, SRM 51-40-02, AND CPM 51-21-06.SDR R61A2018050110544Attach Fitting · corrodedMAINTENANCE FOUND CORROSION ON THE FWD WET AREA LT WIND SCREEN FLOOR ATTACH FITTING, FRAME 19 INBD OF L1 DOOR. THE ATTACH FITTING WAS REMOVED AND REPLACED IAW SRM 51-43-03.SDR R61A201804301522Attach Fitting · corrodedMAINTENANCE FOUND CORROSION IN THE FWD WET AREA, LAVATORY ATTACH FITTING. FRAME 16. THE FITTING WAS REMOVED AND REPLACED IAW IAW SRM 51-43-01.SDR SIMA2018042011006Fitting · crackedFITTING AT FRAME 19 STRINGER 3L CRACKED. REMOVED AND REPLACED THE FITTING IAW SRM 51-40-02.SDR A6WA2018041645769Bracket · crackedRIGHT MLG WHEEL WELL PRESSURE TRANSDUCER BRACKET IS CRACKED. REPLACED THE BRACKET IAW SRM 51-42-06.SDR IPXA2018043029040Fitting · crackedINSPECTION TYPE: D2, A CRACK WAS FOUND ON THE FITTING AT BS 1000 , LBL 78.49. REPAIRED IAW SRID 4-4013799670, AND EO B747-5310-68303-A.SDR AALA20180410009Fitting · corrodedAFT CARGO BAY FLOOR TRANSITION FITTING, BS 1874 TO 1995, RBL 42 HAS CORROSION ON THE RECTANGULAR CUT OUT. REPLACED THE FLOOR TRANSITION FITTING IAW SRM 51-40-02-0G.SDR AALA20180410008Fitting · corrodedAFT CARGO BAY FLOOR TRANSITION FITTING FROM BS 1874 TO 1995, RBL 20 CORRODED. REPLACED THE FITTING IAW SRM 51-40-02-0G.SDR AALA201804239055Coupling · damagedELONGATED HOLE FOUND ON THE COUPLING AT FRAME 70, BL Y765. REPLACED COUPLING IAW SRM 51-72-11, AND DWG D53472816,D53472780.SDR SWAA2018041721246Attach Angle · corrodedR1 DOOR SURROUND STRUCTURE CREASE BEAM ATTACH ANGLE CORRODED BETWEEN BS 301 TO 325, RBL 59. R & R THE ATTACH ANGLE IAW SRM AND DWG.SDR CALA2018040901122Fitting · corrodedR2 DOOR SILL AFT CORNER UNDER GIRT BAR FITTING CORRODED AT FRAME 68. REMOVED AND REPLACED THE FITTING IAW SRM 51-42-11 -001.SDR A6WA2018040945753Bracket · crackedRIGHT MLG PRESSURE TRANSDUCER BRACKET IS CRACKED. REPLACED THE BRACKET IAW SRM 51-42-06, 51-40-11, AND 51-25-16.SDR CALA2018040501106Cleat · corrodedFLANGE ON CLEAT AT FRAME 26, STRINGER 37- 38L CORRODED, REMOVED THE CORROSION IAW SRM 51-74-00-001, PARA 4. OUT OF LIMITS IAW DWG D53230368. REMOVED AND REPLACED THE CLEAT IAW SRM 51-72-11-911-001, AND 51-72-11-911-002 REPAIR CLASSIFIED AS MAJOR IAW GMM 03-2SDR SWIA201804304608Mount · corrodedOUTBOARD AFT WARDROBE FLOOR MOUNT PLATE HAS CORROSION. REPLACED O/B AFT WARDROBE FLOOR MOUNT PLATE IAW SRM.SDR SWIA201804304607Mount · corrodedINBOARD FWD AND AFT GALLEY FLOOR MOUNT PLATES HAVE CORROSION. INSTALLED I/B FWD PLATE IAW SRM.SDR SIMA20180403005Attach Angle · crackedLEFT WING LATERAL PANEL UPPER ATTACH ANGLE CRACKED BEWTEEN FUSELAGE FRAMES 48 AND 49. COMPLETED A REPAIR TO THE ATTACH ANGLE BETWEEN FUSELAGE FRAMES 48-49 IAW SRM 53-23-12 TYPE II.SDR DALA2018040402175Fitting · crackedCRACKED RT FITTING BS 664, RBL 19. THE FITTING WAS REPLACED IAW SRM 51-41-02-0G AND SRM 51-41-05-0G.SDR F3LA2018043000333Fitting · corrodedL1 DOOR LOWER SILL HAS CORROSION UNDER FWD AND AFT GIRT BAR FITTING PLATE ASSBLIES. REPAIRED THE DOOR SILL GIRT BAR FITTING PLATES IAW SRM 53-11-14-283-005.SDR A6WA2018040945758Fitting · crackedBATHTUB FITTING CRACKED AT BS 461.00 OTBD SIDE OF LBL 9. REPLACED THE FITTING IAW SRM 51-40-11, 51-42-06, AND 51-42-21.SDR A6WA2018040345750Angle · crackedREAR PRESSURE BULKHEAD, STRINGER 14L OBLIQUE ANGLE IS CRACKED. REPLACED THE ANGLE IAW SRM 51-42-21, AND REO 601R-53-61-422.SDR FOTR20180330002Attach Bracket · corrodedR2 SERVICE DOOR INNER LOWER FRAME AT BS 993.5, VERTICAL ATTACH BRACKET AT FLOOR LEVEL CORRODED.SDR SWAA2018040420966Attach Angle · crackedBULKHEAD LOWER ATTACH ANGLE CRACKED AT BS 663, RBL 7. REPAIRED THE ATTACH ANGLE IAW ER AND EA.SDR DALA2018033002044Tee Fitting · corrodedDURING INSPECTION, FOUND CORROSION ON THE TEE FITTING AT STRINGER 28L LBL 5.47, BETWEEN BS 351+2 AND 351+4. REPAIRED THE TEE FITTING IAW PRI 566521-14, REV O, AND ERA 566521-14, REV ORIGINAL.SDR SWAA2018041721243Attach Angle · crackedBS 663 BULHEAD ATTACH ANGLE CRACKED, RBL 8. REPAIRED THE ATTACH ANGLE IAW ER AND EA.SDR SWAA2018041021062Bracket · crackedBULKHEAD EXHAUST DUCT BRACKET CRACKED AT BS 663, RBL 15. R & R THE BRACKET IAW SRM & DWG.SDR AALA20180327008Attach Angle · crackedCRACK INDICATION ON THE RIGHT VERTICAL ATTACH (SKATE) ANGLE AT BS 1437. REPLACED ATTACH ANGLE IAW SRM 53-05-00 AND 53-10-00.SDR SWIA2018040544472Mount · corrodedAFT INBD WARDROBE MOUNT PLATE COMMON TO FLOOR STRUCTURE IS CORRODED. AFT MOUNTING PLATE WAS REMOVED AND REPLACED IAW REO.SDR SWIA201844471Mount · corrodedFWD AND AFT INBD GALLEY MOUNT PLATES COMMON TO FLOOR STRUCTURE ARE CORRODED. BOTH MOUNTING PLATES WERE REMOVED AND REPLCED IAW SRM.SDR REXA2018032500272Bracket · crackedFLIGHT DECK PILOT SIDE ANGLE BRACKET IS CRACKED NEAR WINDOW SILL BY BS 210. REMOVED AND REPLACED BRACKET IAW SRM 51-42-21.SDR WVER2018040100002Mount · corrodedFOUND CORROSION ON ANGLE MOUNTING. REPLACED THE ANGLE MOUNT.SDR EE4Y2018041806376Attach Fitting · corrodedDURING AN INSPECTION OF THE A/C BAY AREA, FOUND AT LT PRIMARY AND SECONDARY HEAT EXCHANGERS AREA, THE ATTACHING FRAME WITH SEVERAL POINTS OF CORROSION. THE DAMAGED AREA WAS REPAIRED IAW SR 4-3996015419.SDR AALA20180324001Bracket · crackedMID CARGO DOOR FORWARD EDGE STOP BRACKET CRACKED. INSTALLED A NEW STOP PAD BRACKET IAW 51-00-05-1 AND DRAWING 5910141.SDR IPXA2018040428195Tee Fitting · crackedINSPECTION TYPE: 3C, MAIN CABIN TEE FITTING IS CRACKED AT BS 1321, LONGERON 15R. REMOVED, FABRICATED AND REPLACED THE TEE FITTING IAW DWG AEA7568, AND SRM 51-35-01.SDR IPXA2018040428194Tee Fitting · crackedINSPECTION TYPE: 3C, MAIN CARGO DECK TEE FITTING IS CRACKED AT BS 1321 AND LONGERON 15L. REMOVED, FABRICATED AND REPLACED THE TEE FITTING IAW DWG AEA7568, AND SRM 51-35-01.SDR SWAA2018041021060Tee Fitting · crackedKEEL BEAM PANEL TEE FITTING CRACKED AT BS 551, RBL 6. R & R THE TEE FITTING IAW MM.SDR ASOA201803205082Fitting · crackedBS 280, STRINGER 3L, LINTEL FOUND CRACKED. REPAIRED IAW EC/TC REO 670-53-21-493, REV B, AND S/B 670BA-53-040, REV B.
Back to JASC 5340