JASC 5753
Service difficulty reports · 31,521
Reports filed under 5753 · Trailing Edge Flaps, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5753' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5753' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA010828Skin · delaminatedDURING SCHEDULED C3 CHECK, FOUND LT WING INBOARD T/E AFT FLAP DELAMINATED ON UPPER SKIN. REMOVED AND REPLACED AFT FLAP PER MM.SDR DHL2001806531Rib · crackedC-CHECK - RT WING INBOARD FLAP INTERIOR SKIN RIB SHOWS CRACKS AT STA XRS 162.263. STOP DRILLED IAW SRM 57-2-0 FIG 2. FABRICATED DOUBLER IAW SRM 57-2-0 FIG 2. TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED DOUBLER IAW SRM 57-2-0 FIG 2. STATUS-CLOSED.SDR DHL2001806599Skin · delaminatedC-CHECK - RT WING FLAP JOINT DELAMINATED. R/R JOINT FLAP IAW MM 57-20-1 PAGE 204-214. STATUS-CLOSED.SDR SWAA010806Skin · delaminatedDURING SCHEDULED C2 CHECK, FOUND RT WING INBD AFT T/E FLAP DISBONDED AT RT LOWER SIDE. REMOVED AND REPLACED AFT FLAP PER MM.SDR SWIA972434Flap Track · dirtyWHEN FLAPS ARE SELECTED 45 DEGREES OUTBOARD PAIR OF FLAPS STOPS AT APPROXIMATELY 35 DEGREES (DISAGREEMENT). FLAPS EXTEND TO 45 DEGREES AT APPROXIMATELY 120 - 125 KTS. CLEANED FLAP TRACK AND ROLLERS. OPS CHECK GOOD.SDR SWIA972439Flap Track · dirtyFLAP DISAGREEMENT IN FLIGHT DURING FLAP RETRACTION. FOUND FLAP TRACKS AND ROLLERS DIRTY. CLEANED ALL TRACKS AND ROLLERS. OPERATED FLAPS NUMEROUS TIMES. OPS CHECK GOOD AT THIS TIME.SDR TWAA0104912Skin · dentedDURING CHECK-C MAINT FOUND DENT ON RIGHT WING ON BOTTOM SIDE OF TRAILING EDGE FLAP, 4 IN BY 4 IN BY .6875 INCH, OUTBOARD AND AFT OF RT MAIN GEAR. APPLIED WET LAY UP. APPLIED CONDUCTIVE COAT AND PRIMER.SDR ARWA0010305Bolt · brokenDURING PREFLIGHT INSPECTION FOUND LT INBOARD FLAP TRACK BROKEN HANGER BOLT. REMOVED AND REPLACED LT INBOARD FLAP STA 97 TRACK HANGER BOLT IAW MM 27-51-3. OPERATIONAL CHECK OF THE FLAP SYSTEM FOUND NORMAL IAW MM 27-53-1.SDR MWEA010326Structure · chafedRIGHT WING FLAP LEADING EDGE IS CHAFED 3 INCHES INBOARD OF FLAP HINGE FITTING. BLENDED RUB STRIP OUT OF LIMITS. REMOVED DAMAGED SECTION, FABRICATED, LOCATED, DRILLED AND INSTALLED NEW SECTION.SDR DHL2001806603Skin · crackedC-CHECKED - LT WING L/E LWR SKIN SURFACE CRACKED 1/2 INCH AT STA XFS 585. CUT OUT DAMAGED AREA OF LT WING L/E LWR SKIN XFS 585 AND FABRICATED FILLER AND DOUBLER IAW SRM 57-2-0 FIG 2. CLEANED, TREATED AND PRIMED IAW SRM 51-1-8B. INSTALLED FILLER AND DOUBLESDR EISA20010070Flap · delaminatedDURING ROUTINE B-CHECK INSPECTION, FOUND RT INBOARD LOWER FLAP HAS DELAMINATED AREA. BONDED FIBERGLASS OVERLAYS TO REPAIR DOUBLER AND FILLER, ALODINED, SEALED AND PRIMED IAW SRM 51-40-5, 51-40-2, 57-50-1 AND M/M 51-20-151.SDR TWAA0104608Skin · delaminatedDURING CHECK-C THE RT WING OTBD T/E FLAP OTBD END, 48 INCHES FROM THE OTBD END AND 7.5 IN FROM THE T/E HAD A 5 IN BY 3.75 IN DELAMINATION. INSTALLED REPAIR 9 IN BY 21 IN WET LAYUP USING SRM 51-70-17 AS GUIDE. PRIMED AND PAINTED PER MM 51-22-02.SDR DL72W010404Shim · looseINSPECTIONS OF THE INBD FLAP INBD TRACK ON THE RT WING PER AD 90-07-05 REVEALED A LAMINATED SHIM WHICH HAD MIGRATED MORE THAN THE .25 INCH ALLOWED. THE MIGRATED SHIM WAS REMOVED AND REPLACED AND THE ATTACH BOLTS RE-TORQUED PER THE REQUIREMENTS ON THESDR AALA20014013Bearing · looseAFW - FOUND RIGHT INBOARD FLAP OUTBOARD SUPPORT FITTING OUTBOARD TOP MOUNT BEARING LOOSE. REMOVED GOUGES AND REAM BORE TO 1.81-1.84 INCH DIAMETER. FABRICATE REPAIR BUSHING PER REF REPAIR 5-1 WITH THE FOLLOWING DEVIATIONS. BUSHING WALL THICKNESS TO BE A MINISDR SWAA010713Skin · delaminatedDURING SCHEDULED SPECIAL VISIT, FOUND RT WING T/E AFT FLAP DELAMINATED AT T/E. REMOVED AND REPLACED AFT FLAP PER MM.SDR DHL2001741506Skin · delaminatedRT I/B MID FLAP UPPER SURFACE DELAMINATED AREA AT I/B TRAILING EDGE AREA (MKD). INSTALLED BOND REPAIR TO I/B MID FLAP UPPER SURFACE AT I/B TRAILING EDGE AREA AS PER B727 SRM 51-40-6 PAGE 7 MATERIAL USED ADHESIVE AF 163-2K 085 PO 2429 AND ALUMINUM 7075-T6 016 SDR COOSDR02016Fitting · corrodedFITTING, LEFT WING, OUTBOARD MID-FLAP INBOARD/OUTBOARD FITTINGS FLAP CARRIAGE WITH CORROSION.SDR DKAA01002Flap · damagedRIGHT INBOARD FLAP NR 2 AFT PANEL DAMAGED AT XFS209.5. REPAIRED PER DER DRAWING NR 57-01010-3, DATED 01/16/2001. AIRCRAFT RETURNED TO SERVICE. (M)SDR F3LA200100041Tube · corrodedDURING C-1 CHECK, INSPECTION REPORTED INTERIOR OF LT INBD FOREFLAP SUPPORT TUBE CORRODED. REPLACED LT INBD FOREFLAP SUPPORT TUBE PER BAC OHM 57-53-26.SDR 20010507CW006Bracket · wornINSPECTION FOUND ALL FLAP TRACK BRACKETS WORN BEYOND ACCEPTABLE LIMITS.SDR 20010507CW005Bracket · wornINSPECTION FOUND ALL FLAP TRACK BRACKETS WORN BEYOND ACCEPTABLE LIMITS.SDR SWAA010689Skin · delaminatedDURING SCHEDULED C2 CHECK, FOUND LT WING OUTBD T/E AFT FLAP DELAMINATED AT INBD AFT CORNER. REMOVED AND REPLACED AFT FLAP PER MM.SDR DHL2001806639Fitting · crackedC-CHECK, LT WING VERIFY POSSIBLE CRACK ON FITTING FROM O/B FLAP STA 406.000. PERFORMED HFEC INSPECTION IAW DC-8 NON-DESTRUCTIVE TESTING STANDARD PRACTICE MANUAL PART 6.SDR DL72L011111Rib · crackedINBOARD AFT RIB CRACKED ON THE NR 1 MID FLAP. REPAIRED PER M/M 57-52-0 FIG 808.SDR SWAA010629Skin · delaminatedDURING SCHEDULED C4 CHECK, FOUND LT WING OUTBOARD T/E AFT FLAP DELAMINATED AT INBOARD LOWER SURFACE. REMOVED AND REPLACED AFT FLAP PER MM.SDR SWAA010628Skin · delaminatedDURING SCHEDULED 1/2D CHECK, FOUND LT WING T/E OUTBOARD AFT FLAP DELAMINATED AT INBOARD SIDE. REMOVED AND REPLACED AFT FLAP PER MM.SDR SWAA010627Skin · delaminatedDURING SCHEDULED 1/2D CHECK, FOUND LT WING INBOARD T/E AFT FLAP DELAMINATED AT OUTBOARD SIDE. REMOVED AND REPLACED AFT FLAP PER MM.SDR MALA010308Skin · chafedFOUND DURING C-CHECK, IN NASHVILLE, TN. RT FLAP UPPER SURFACE PANEL 641AT IS CHAFED AFT OF THE FORWARD IB EXHAUST COWLING CHAFE STRIP. MAINTENANCE SMOOTHED OUT, CHECKED LIMIT.REMAINING MATERIAL IS WITHIN LIMITS OF S/B340-57-012, ALODINED, PRIMED, REPAIRED CHASDR SWAA010610Skin · delaminatedDURING SCHEDULED 1/4D CHECK, FOUND RT WING OUTBD AFT FLAP INBD CORNER DELAMINATED. REMOVED AND REPLACED AFT FLAP PER MM.SDR 2001UALA00225Skin · gougedRT INBOARD FOREFLAP GOUGED AT OUTBOARD LOWER SURFACE. REPAIRED FOREFLAP PER SRM 57-50-04 FIG 1.SDR SWAA010582Skin · delaminatedDURING SCHEDULED 1/4D CHECK, FOUND LT WING INBD T/E AFT FLAP DELAMINATED AT OUTBD AFT EDGE. REPAIRED AFT FLAP PER SRM.SDR DL72L010324Flap Track · corrodedDURING OVERHAUL AT BF GOODRICH THE INBOARD FLAP, NR 4 INBOARD TRACK WAS FOUND WITH WEAR AND CORROSION AT THE MLG AND SPOILER BEAM ATTACH PADS, THE MLG DOOR FWD HINGE FITTING AND FWD BRACKET LOWER ATTACH HOLES, FWD LUG BORES, AND IN THE TOGGLE DETENT HOLESDR 2001UALA00185Skin · delaminatedRIGHT INBOARD FLAP IS DELAMINATED AND LEFT INBOARD FORE FLAP UPPER SURFACE IS CHAFED. REMOVED AND REPLACED RIGHT INBOARD FLAP PER MM 27-51-04. REPAIRED LEFT INBOARD FORE FLAP PER GN MM 1-0-1-66.SDR SWAA010534Skin · delaminatedDURING SCHEDULED SERVICE CHECK, FOUND LT WING T/E OUTBD AFT FLAP DELAMINATED. REMOVED AND REPLACED AFT FLAP PER MM.SDR AWXA0001406Former · wornLT WING NR3 FLAP TRACK FAIRING AFT I/B FORMER AND FORMER ANGLE WORN AT AFT END. REMOVED FORMER AND FORMER ANGLE IAW SRM 51-40-02; FABED ANGLE AND INSTALLED NEW FORMER AND ANGLE IAW DWG 65C28309-33.SDR SWAA010515Skin · delaminatedDURING SCHEDULED SERVICE CHECK, FOUND LT WING OTBD T/E AFT FLAP DELAMINATED AT INBD END. REMOVED AND REPLACED AFT FLAP PER MM.SDR SWAA010510Skin · delaminatedDURING SCHEDULED SERVICE CHECK, FOUND LT INBD T/E AFT FLAP OTBD EDGE DELAMINATED. REMOVED AND REPLACED AFT FLAP PER MM.SDR ABXA010055Mount · corrodedRIGHT FLAP CARRIAGE MOUNT ANGLE WAS CORRODED. MAINTENANCE INSPECTED AND MANUFACTURED NEW FLAP MOUNT ANGLE PER DOUGLAS DRAWING 9923445 AND INSTALLED IAW DC-9 SRM 51-30-5.SDR AWXA0001391Attach Angle · crackedATTACH ANGLE CRACKED ON LT WING I/B MID FLAP O/B END. REMOVED AND REPLACED ATTACH ANGLE IAW SRM 51-40-02.SDR CA010403010Bearing · broken(CAN) DURING TAXI, FLAPS SELECTED WITH INDICATION PROBLEM. AIRCRAFT RETURNED TO GATE. FURTHER INVESTIGATION FOUND RT FLAP CARRIAGE BEARINGS WAS BROKEN IN 2 PIECES AND A SECOND BEARING SPLIT. NEW PARTS INSTALLED AND FLAP RIGGING CARRIED OUT I.A.W. MM. NO FURTHESDR UPS01235225Bolt · crackedINSPECTION TYPE:C+SI, DURING MAG PARTICLE INSP DEAD WEIGHT ROLLER BOLT NR 6 FOUND CRACKED. BOLT REPLACED IAW MM 27-51-03.SDR RRXA010504Panel · crackedDURING A MAINTENANCE VISIT FOUND A CRACK TO THE L/H I/B FLAP TRACK COVER PANEL BETWEEN STA 960-980, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DCSDR UPS01235260Attach Fitting · corrodedINSPECTION TYPE:C+SI, NR 1 FLAP TRACK ATTACH FITTING ON LWR SURFACE OF WING HAS LIGHT SURFACE CORROSION ON INBOARD SIDE AND OUTBOARD SIDE. REWORKED IAW SMRO EO 2001-006-006.SDR UPS01235259Flap Track · corrodedINSPECTION TYPE:C+SI, NR 5 FLAP TRACK HAS EVIDENCE OF CORROSION TO INBD LUG AT FWD ATTACH POINT. CORROSION REMOVED AND REWORKED IAW OHM 57-40-01.SDR UPS01235250Fitting · corrodedINSPECTION TYPE:C+SI, NR 7 FLAP TRACK ATTACH FITTING ON LWR SURFACE OF RT WING HAS LIGHT SURFACE CORROSION ON INBD FACE OF FITTING. CORROSION REMOVED IAW OHM REF EO SMRO 2001-006-008 FOR DETAILS.SDR UPS01235239Skin · crackedINSPECTION TYPE:C, LEFT WING I/B AFT FLAP LOWER SURFACE L/E CRACKED AT O/B CENTER ECCENTRIC ROLLER FITTING CUTOUT. REPAIRED PER SRM 57-50-4.SDR SWAA010474Flap · delaminatedDURING SCHEDULED 1/4D CHECK, FOUND LT INBD T/E AFT FLAP DELAMINATED AT OUTBD T/E. REMOVED AND REPLACED FLAP ASSY PER MM.SDR EISA20010065Skin · puncturedDURING ROUTINE C-CHECK INSPECTION FOUND RIGHT TRAILING EDGE FLAP HAS PUNCTURE HOLE. FABRICATED REPAIR DOUBLE, SEPTUM AND CONE FILLER, BONDED REPAIRS, ALODINED, SEALED, AND PRIMED AREA IAW SRM 51-40-20 FIG 18, 57-50-2, 51-10-2, M/M 51-20-151.SDR EISA20010062Skin · gougedDURING ROUTINE C-CHECK INSPECTION FOUND LEFT WING INBOARD FOREFLAP INBOARD END UPPER AND LOWER SURFACES GOUGED. FABRICATED DOUBLER AND FILLER, BONDED REPAIR FILLER AND DOUBLER, ALODINED AND PRIMED REPAIRS AND PAINTED IAW SRM 51-10-2, 51-40-20 FIG 17, 57-50-2,SDR UPS01235258Flap Track · corrodedINSPECTION TYPE:C+SI, NR 7 FLAP TRACK, AFT MOUNT OTBD HOLE DAMAGED DUE TO CORROSION. REWORKED IAW OHM 57-40-01.
Back to JASC 5753