JASC 5753
Service difficulty reports · 31,521
Reports filed under 5753 · Trailing Edge Flaps, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5753' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5753' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AU980829Track · worn(AUS) FLAP TRACKS WORN. SEE MDR 98/0828 FOR ADDITIONAL INFORMATION.SDR AU980828Roller · worn(AUS) FLAP ROLLERS WORN AND CORRODED.SDR CALA9801275Skin · delaminatedINSPECTION FOUND RT I/B AFT FLAP DELAMINATED AT 15 INCHES O/B OF I/B END AT UPPER SURFACE. THE AFT FLAP WAS REMOVED, REPAIRED AND REINSTALLED IAW WORK CARD 07-5750-1-2802.SDR CALA9801273Skin · delaminatedINSPECTION FOUND LT I/B FOREFLAP UPPER SKIN INBOARD END DELAMINATED. THE FOREFLAP WAS REMOVED, REPAIRED AND REINSTALLED IAW WORK CARD 07-5750-1-2801.SDR CALA9801272Rib · crackedINSPECTION FOUND A 2 INCH CRACK IN RT WING INBOARD FLAP OUTBOARD CABLE ATTACH RIB (MIDFLAP). THE MIDFLAP WAS REMOVED AND REPLACED IAW WORK CARD 07-5750-1-4703.SDR TWAA9813702Skin · damagedDURING ROUTINE CHECK OF ACFT, FOUND RT O/B TE FLAP, I/B OF I/B CANOE, WITH LEADING EDGE DAMAGED 18 IN BY 8 IN. REPAIRED DAMAGE PER SRM 57-53-01 AND 57-70-17. CHECK-C 6-28-98 LAX.SDR 98ZZZX3744Skin · chafedICT - OVERNIGHT MAINTENANCE FOUND A CHAFED SPOT ON THE DOVETAIL SKIN ON LT IBD FLAP. REPAIRED IAW ANWA TO 2900-27-00-0001. (X)SDR UPS98227181Track · corrodedINSPECTION TYPE-SI, CORROSION (C57-581-06.00-04) NR 7 FLAP TRACK FWD LUG HAS RUST AROUND BOLT HOLE. REMOVED FLAP TRACK AND SENT TO OUTSIDE SERVICES FOR REPAIR AND REINSTALLED AFTER REPAIR.SDR UPS98227180Track · corrodedINSPECTION TYPE-SI, NR 1 FLAP TRACK FWD MOUNT BOLT LUGS ARE CORRODED. REMOVED FLAP TRACK AND SENT TO OUTSIDE SERVICES FOR REPAIR AND REINSTALLED AFTER REPAIR.SDR UPS98227179Track · corrodedINSPECTION TYPE-SI, NR 3 FLAP TRACK CENTER MOUNT BOLT IS CORRODED ON THE AFT SIDE CORROSION (C57-581-06.00-03) AND CORROSION (C57-581-06.00-03) NR 3 FLAP TRACK IS CORRODED ON THE SPOILER BEAM MOUNT PAD. FLAP TRACK REMOVED AND SENT TO OUTSIDE SERVICES FOR REPASDR 98ZZZX3743Skin · crackedICT - OVERNIGHT MAINTENANCE FOUND A 1 INCH CRACK ON LT OTBD FLAP 11 INCHES FROM TRAILING EDGE AND 29 INCHES FROM INBD EDGE ON BOTTOM SKIN. REPAIRED CRACK IAW AMWA TO 1900-27-00-0001. (X)SDR P5CA9801177Skin · damagedRIGHT OUTBOARD FLAP, MID FLAP LOWER SKIN JUST OUTBOARD OF JACK SCREW HAS A HOLE IN THE SKIN. REMOVED, SANDED DAMAGED AREA, PREPARED FOR BONDING, POTTED DAMAGED .5 INCH DIA APPLIED 3 PLY FIBERGLASS LAY-UP IAW SRM 51-40-09.SDR DHL9872175DSkin · crackedAT D-CHECK, RIGHT O/B AFT FLAP L/E LOWER SURFACE HAS CRACK ON SKIN AT FITTING, 2 FT FROM I/B END. HFEC CONFIRM CRACK CONTAINMENT. INSTALLED DOUBLER REPAIR PER SRM 57-50-4, 6.25 X 4.5. N/R 2565.SDR DHL9872155DSkin · dentedAT D-CHECK, LEFT I/B AFT FLAP HAS A DENT ON UPPER SURFACE. CUT OUT DAMAGED AREA, INSTALLED REPAIR PER SRM 57-50-4, 7 X 4.5. N/R 1414.SDR UPS98227225Fairing · corrodedINSPECTION TYPE:C, NR 1 FLAP TRACK MID FAIRING FWD HINGE CASTING CORRODED. CASTING REPLACED IAW SRM 51-30-02.SDR UPS98227209Fitting · corrodedINSPECTION TYPE:C, NR 6 FLAP TRACK MIDFAIRING FWD HINGE CASTING HAS LIGHT SURFACE CORROSION FITTING REPLACED IAW SRM 51-30-02.SDR UPS98227234Fairing · crackedINSPECTION TYPE-C, NR 5 FLAP TRACK AFT FAIRING CRACK AT AFT INBOARD CORNER. FLAP FAIRING REPAIRED IAW UPS EO B727-5750-3837.SDR DHL9872173DLink · gougedAT D-CHECK, RT WING LOWER FOREFLAP CENTER ATTACHING LINK LOWER SURFACE GOUGED AND CORRODED. CUT OUT DAMAGED AREA, INSTALLED DOUBLER REPAIR PER SRM 57-50-4, 5 X 5. N/R 2547.SDR DHL9872148DSkin · crackedAT D-CHECK, RT WING O/B FOREFLAP ATTACHING POINT 53 FROM I/B EDGE CRACKED AND RIVETS LOOSE. FABRICATED DOUBLER PER SRM 57-40-4, 3.75 X 3.5. N/R 2546.SDR 98ZZZX3216Bracket · crackedPN POST-FLIGHT AT OXC, FOUND LT WING SHROUD BENT, THE FLAP VANE MISSING, AND THE TWO BRACKETS THAT ATTACH THE VANE TO THE FLAP WERE BROKEN. THE AIRCRAFT HAD A 48 MONTH 2400 HOUR INSPECTION IN 1-98 AND THE FLAPS AND VANES WERE X-RAYED AT THAT TIME. WILL REVIESDR UPS98227202Track · damagedINSPECTION TYPE:C, LT WING INB FLAP INB FLAP TRACK DAMAGED DUE TO SHEARED DEAD WEIGHT ROLLER. REMOVED NR 4 FLAP TRACK IAW MM 27-51-31. INSTALLED NEW TRACK IAW MM 27-51-31.SDR UPS98227194Casting · crackedINSPECTION TYPE-C, NR 4 FLAP TRACK TEAR DROP FAIRING SPIGOT CASTING CRACKED. REPLACED CASTING IAW MM 27-50-00.SDR UPS98227191Casting · crackedINSPECTION TYPE-C, NR 5 FLAP CARRIAGE LWR DEAD WEIGHT ROLLER CASTING CRACKED. FITTING AND ASSOCIATED HARDWARE REPLACED IAW OHM 57-58-02.SDR UPS98227189Angle · crackedINSPECTION TYPE-C, LWR CHORD ANGLE ON LT INB MIDFLAP INB CARRIAGE SUPPORT STRUCTURE CRACKED. LWR CHORD ANGLE REPLACED IAW SRM 51-30-02.SDR UPS98227195Rib · crackedINSPECTION TYPE-C, SUSPECT CRACK IN LT I/B FLAP I/B CARRIAGE SUPPORT STRUCTURE. RIB CHORD REPLACED IAW SRM 51-30-02.SDR TWAA9811003Rib · bentMCI - DURING OP 16 MAINTENANCE CHECK, FOUND ON LT WING FLAP, TWO RIBS INSIDE LOWER INBD ACCESS PLATE WERE BENT. INSTALLED REPAIR DOUBLER PER ARA 15361. ACFT TT: 77,210 HOURS. ACFT TC: 84,221. (X)SDR DL72S981412Flap Track · corrodedINB'D FLAP, INB'D TRACK, TYP CORROSION AT FWD AND AFT, PAD-UP ATTACH HOLES AND FWD LUG: AD 90-07-05. FWD AND AFT PAD-UP ATTACH HOLES SUBJECT OF AD 90-07-05; REC'D BAC/FAA APPROVAL TO STEP-UP HOLES AND BUSH. FWD ATTACH LUG NOT SUBJECT OF AD; REC'D BAC APPROVSDR 98FDEA00437Casting · corrodedN/R N00434 STA-LAX: RT WING INBD FLAP, INBD FLAP DRIVE MOUNT HOLE (INBD) HAS DEEP CORROSION AROUND SECTION OF BUSHING. REMOVED CORROSION REF SRM 51-21-01. C/W HFEC REQUIRED BY ENGINEERING NO CRACK INDICATION FOUND. REF: EA 8-5750-38590.SDR DL72S981573Skin · repairedDURING SHOP VISIT, THE COVE SKIN WAS FOUND CRACKED 31 FROM IB END OF FLAP. THE SKIN WAS REPAIRED PER 727 MM 57-52-0, FIG 809, BY REMOVING THE DAMAGE AND INSTALLING A DOUBLER AND FILLER.SDR DL72S981572Angle · repairedDURING SHOP VISIT, THE REAR CHORD ANGLE WAS FOUND CRACKED 17 AND 22 FROM IB END OGF FLAP. THE ANGLE WAS REPAIRED PER 727MM 57-52-0 BY INSTALLING A DOUBLER.SDR DL72S981571Angle · crackedTHE MIDFLAP REAR CHORD ANGLE WAS FOUND CRACKED 37 AND 31 FROM IB END DURING SHOP VISIT. THE ANGLE WAS REPAIRED PER 727 MM 57-52-0 BY INSTALLING A DOUBLER.SDR DL72S981570Angle · repairedDURING SHOP VISIT, THE NR 3 MIDFLAP, SN DL15, WAS FOUND WITH A CRACKED REAR CHORD ANGLE. THE ANGLE WAS REPAIRED PER 727 MM 57-52-0, FIG 802 BY INSTALLING A DOUBLER.SDR CALA9801197Angle · crackedINSPECTION FOUND A CRACK IN AFT END OF LOWER ANGLE AT RT OUTBOARD MID-FLAP INBOARD END RIB. THE CRACK WAS STOP DRILLED AND A DOUBLER WAS FABRICATED AND INTALLED IAW SRM 51-40-2.SDR C2XA98IA232Rib · crackedIAH - DURING C-CHECK INSPECTION, FOUND LEFT NACELLE FLAP CRACKED ON OUTBOARD NOSE RIB. MAINTENANCE STOP-DRILLED THE CRACK AND INSTALLED A REPAIR DOUBLER IAW EMB-120 SRM 54-20-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)SDR COMA9860171Vane · damagedC-CHECK TASK 002-27-580-100 LEFT WING INBORAD FLAP VANE AT WS 86.30 HAS CHAFE DAMAGE. REPLACED FLAP.SDR UPS98827113Rib · crackedINSPECTION TYPE:C LT WING T/E AT FLAP STA 3.00, THE T/E RIB IS CRACKED BEHIND NR 1 SPOILER I/B HINGE. STOP DRILLED CRACK AND REPAIRED IAW SRM57-2-0 FIG 2.SDR P5CA9801075Skin · delaminatedRT WING INBOARD FOREFLAP LOWER SURFACE FOUND DELAMINATED. REPAIRED AREA OF FIBERGLASS DELAMINATION PER SRM 51-40-12.SDR DL72S981620Angle · crackedDURING SHOP INSPECTION, THE AFT LOWER CHORD ANGLE WAS FOUND CRACKED IN 21 PLACES AT I/B CUTOUT FOR I/B AFT FLAP DRIVE. THE ANGLE WAS REPAIRED BY STOP DRILLING THE CRACKS AND INSTALLING A DOUBLER PER 727 MM 57-52-0, PG 807.SDR TWAA9810802Flap · contaminatedLAX - DURING CHECK-C, MAINTENANCE FOUND ON RT WING NR 4 TE FLAP INBD AFT SIDE WITH INDICATION OF WATER. AFTER WATER REMOVED, INSTALLED 12 BY 30 PANEL AND ADHESIVE HOT BOND PER SRM 51-70-07, AND LIMITS PER 57-53-01. ACFT TT: 63,613 HOURS. ACFT TC: 14,886. SDR TWAA9810206Flap · contaminedLAX - DURING CHECK-C, MAINTENANCE FOUND ON RT WING THE NR 4 TE FLAP INBD AFT SIDE WITH INDICATION OF WATER. AFTER WATER REMOVED, INSTALLED 12 BY 30 PANEL AND ADHESIVE HOT BOND PER SRM 51-70-07, AND LIMITS PER 57-53. TOTAL TIME: 63,613 HOURS. TOTAL CYCLES: SDR DL72S981437Flap Track · corrosionINB'D FLAP/INB'D TRACK TYP CORROSION AT FWD AND AFT PAD-UP ATTACH HOLES AND FWD LUG - AD 90-07-05 AND 90-06-09. OVERSIZE HOLES AND SHIM FWD LUG FACE.SDR HALA9800180Flap Track · corrodedTULE - (NR 116312) - INBOARD FLAP TRACK POST HAS CORROSION IN VARIOUS HOLES ON INBOARD FLAP ON RIGHT-HAND WING. STA 118 XORS. REAMED HOLES TO REMOVE CORROSION AND INSTALLED BUSHINGS PER AARD 57-20-00-10. (X)SDR DL72S981521Doubler · damagedREPAIR DOUBLER IS CRACKED AT LWR AFT SPAR 21 AND 35 FROM I/B END. THIS DAMAGE WAS REPAIRED PER M/M 57-52-0, FIG 802. THIS DAMAGED WAS RECORDED ON N/R 007474 AND 007475.SDR CALA9801138Fairing · crackedINSPECTION FOUND A 2.5 INCH CRACK IN LT FLAP INBOARD FLAP TRACK FAIRING TRAILING EDGE. THE FAIRING WEB AND ANGLE WERE REMOVED. A NEW WEB AND ANGLE WERE FABRICATED AND INSTALLED IAW SRM 51-10-2 AND 51-10-3.SDR DL72S981522Skin · damagedCOVE SKIN IS CRACKED 32 FROM I/B END. THIS DAMAGED WAS RECORRED ON SHOP N/R 007470 AND REPAIRED PER M/M 57-52-0 FIG 809.SDR AU980644Lug · broken(AUS) LT FLAP CONTROL HORN LUG FAILED.SDR CALA9801122Skin · corrodedINSPECTION FOUND LT TRAILING EDGE INBOARD FLAP INTERIOR CORRODED AND FINGER DOUBLERS SEPARATED. THE T/E FLAP SKIN WAS REMOVED. NEW SKIN AND BONDED DOUBLER WERE FABRICATED AND INSTALLED IAW SRM 57-50-9, FIGURE 6, 51-70-2, AND 51-30-2.SDR TWAA9809811Spar · crackedMCI - DURING OP 16 MAINTENANCE CHECK, FOUND RT WING INBD TE FLAP HINGE CASTING ATTACH HOLES WITH .75 INCH LONG CRACK INDICATION ON SPAR WEB AT LOWER INBD MOUNT HOLE. INSTALLED REPAIR DOUBLER PER JO 6027 REAR SPAR REPAIR DRAWING. TOTAL TIME: 72,210 HOURS. TSDR CALA9801066Skin · cannedINSPECTION FOUND OIL CANNING ON LEFT INBOARD TRAILING EGDE FLAP UPPER SKIN AT INBOARD SIDE. THE DAMAGED SKIN SECTION WAS REMOVED, NEW SKIN WAS FABRICATED AND INSTALLED IAW SRM 51-21-01 AND 51-30-02.SDR DHL9870928CFairing · crackedAT C CHECK, NR 4 FLAP TRACK FIXED FAIRING HAS CRACKED RIB AT AFT END. REMOVED AND REPLACED FAIRING RIB PER SRM 51-30-2, N/R 1877.
Back to JASC 5753