Airbus A310-203
Service difficulty reports · 2,392
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A310203' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A310203' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 04FDEA02558Sequence Valve · malfunctionedON INITIAL TAKEOFF RETRACTED GEAR AND LT MLG REMAINED DOWN AND LOCKED WITH RED UNLOCK LIGHT ILLUMINATED ON BOTH LANDING GEAR PANELS. PLACED GEAR HANDLE DOWN AND GOT 3 GREEN NO RED LANDED UNEVENTFUL SYSTEM 1 SELECTED. PER FLIGHT CREW DEBRIEF, THE DOOR OPEN LISDR 04FDEA02543Connector · corrodedNR 1 MLG DOOR WOULD NOT CLOSE ON GEAR RETRACTION. PUT GEAR DOWN IAW ECAM, RETURNED FOR LANDING. PERFORMED BITE CHECK OF PROX DET UNIT REF A310 M/M 32-31-71-4, RECEIVED BOX FAULT CODE (BOX LIGHT ON) CODE 64= 28VDC POWER SUPPLY NR 4 OR NR 3,SEE A310 TSM 32-SDR 04FDEA02498Adc · malfunctionedAT 80 KTS THE F/O CALLED NO AIRSPEED. REJECTED T/O MAX SPEED 85 KTS. F/O HAD NO AIRSPEED INDICATIONS ON PFD, F/O PITOT PROBE BAGGED AND STATIC LINE PURGED WITH DRY N2 FROM NR 2 ADC, NO BLOCKAGE OR CONTAMINATION FOUND. CHANGED NR 2 ADC PER AMM SUPPLEMENT 34-SDR 04FDEA02440Pylon · crackedNR 1 ENGINE AFT UPPER PYLON HAS CRACKED UNDER PNL 473CL. STOP DRILLED CRACK AND INSTALLED U-CHANNEL IAW A310/200 SRM 54-50-00 AND 54-54-11 FIG 201 AND 54-54-51 FIG 206 BETWEEN PYLON STA 1059 AND STA 1115.SDR 04FDEA02439Seat Track · corrodedMDC ON RT SEAT TRACK NR 3 FR53 NOTED CORROSION INSIDE SCALLOP HOLES AND ON FLANGE. REMOVED DAMAGED SECTION AND INSTALLED NEW SECTION IAW A310/200 SRM 53-10-16.SDR 04FDEA02438Dummy Rail · corrodedUPPER MAIN CABIN FR48 BETWEEN TRACK D & E HAS 1EA DUMMY TRACK WITH CORROSION BEYOND REPAIRABLE LIMITS. REMOVED AND REPLACED DUMMY TRACK IAW A310 SRM 51-72-10.SDR 04FDEA02437Dummy Rail · corrodedUPPER MAIN CABIN BETWEEN D & E HAS 3EA DUMMY TRACK WITH CORROSION (LEVEL 2) AND 1EA DUMMY TRACK CRACKED (2 INCHES IN LENGTH) BETWEEN FR 52 AND 53. REMOVED AND REPLACED 4EA DUMMY TRACKS.SDR 04FDEA02435Fuel Tank · crackedAT BLOCK IN, FOUND LT OUTER WING FUEL TANK LEAKING FROM BOTTOM OF WING JUST OUTBD OF RIB NR 20, JACK 05, TRACK 08. FUEL COMING OUT OF DRAIN HOLE ON BOTTOM OF WING JUST FWD OF OVAL ACCESS PANEL. MX FOUND LT NR 8 SLAT TRACK CANISTER TO HAVE APPROX 1 - 2 INCH CSDR 04FDEA02393Floor Support · corrodedFLOOR SUPPORT CORRODED FWD PIT LEFT OF CTR AND AFT OF FR 38.2 (LEVEL 2). REMOVED AND REPLACED FLOOR SUPPORT (ANGLE) IAW A310/200 SRM 51-40-21.SDR 04FDEA02392Roller Tray · corrodedFWD PIT CTR ROLLER TRAY AT JUST FWD OF FR 38.1 BOTTOM SIDE IS CORRODED (LEVEL 2). REMOVED DAMAGED SECTION AND INSTALLED SPLICE SECTION IAW A310/200 SRM 53-10-15.SDR 04FDEA02391Floorbeam · corrodedLOWER FUSELAGE BULK CARGO PIT LATERAL FLOORBEAM AT FR66 LT OF CENTERLINE HAS EXFOLIATED CORROSION AROUND FASTENER HOLE (LEVEL 2). REMOVED DAMAGED AREA, FABRICATED FILLER, ANGLE AND INSTALLED IAW A310/200 SRM 53-10-15 AND 51-25-00.SDR 04FDEA02335Tee Fitting · corrodedMDC FR 10 TO FR 14A, 20 INCHES OUTBOARD FROM LEFT OF CTR T-CAP HAS CORROSION (LEVEL 2) INCLUDING IN AND AROUND ALL FASTENER HOLES. REMOVED AND REPLACED T-CAP IAW A310/200 SRM 51-40-21.SDR 04FDEA02159Crossbeam · crackedZONE 232 FRAME IS CRACKED UNDER CLS ADAPTER PLATE AT FR 23 BETWEEN SEAT TRACKS 1R & 2R. REPAIRED CRACKED FRAME 23 IAW A310-200 SRM 53-10-15 WITH REPAIR ANGLES AND FILLERS. WORK DOCUMENTED ON NRC N00411.SDR 04FDEA02157Seat Track · corrodedMAIN CABIN SEAT TRACK 1L 3 INCHES AFT OF FR 38.2 HAS CORROSION ON SCALLOPS. REMOVED AND REPLACED SEAT TRACK IAW A310-200 SRM 51-40-20, 51-40-21, AND 51-72-10.SDR 04FDEA02156Seat Track · corrodedMAIN CABIN DUMMY TRACK 2R FR38.2 TO FR40/41 HAS 3 EA AREAS OF EXFOLIATED CORROSION LEVEL 3. REMOVED AND REPLACED SEAT TRACK IAW 51-40-20 AND 51-40-21.SDR 04FDEA02155Seat Track · corrodedMAIN CABIN SEAT TRACK 2R FR45 TO FR54 HAS 6 EA AREAS OF EXFOLIATED CORROSION. REMOVED AND REPLACED SEAT TRACK IAW A310 SRM 51-72-10.SDR 04FDEA02154Mount · damagedMAIN CARGO COMPT LAV I/B AFT MOUNTING HOLE IS GOUGED. REPLACED DAMAGED SECTION OF TEE CAP IAW A310 SRM 51-40-21, 51-27-00, 51-23-10, AND 51-21-10.SDR 04FDEA02153Seat Track · crackedMAIN CABIN SEAT TRACK 2R FR 40/41 TO 6 INCHES AFT OF FR 45 IS 1 CORRODED AND CRACKED AT FR 43 ON THE I/B SIDE FLANGE AND 2 CORRODED IN THE SCALLOP AREA 10 INCHES AFT OF FR 44 (LEVEL 2). REMOVED AND REPLACED SEAT TRACK FROM FR40 TO FR 46 IAW SRM 51-72-10.SDR 04FDEA02152Seat Track · corrodedMDC - SEAT TRACK L4 AT FR 16 HAS SEVERE LEVEL 3 CORROSION STARTING AT FR 16 AND GOING FORWARD 26 INCHES. REMOVED AND REPLACED TRACK IAW A310 SRM 51-40-20 AND 51-40-21.SDR 04FDEA02068Seat Track · crackedMDC, LATERAL SEAT RACK AT FRAME 44 BETWEEN SEAT TRACK R1 AND R2 HAS A POSSIBLE CRACK ON BOTTOM SIDE OF TRACK ON OUTBOARD END. REMOVED AND REPLACED SEAT TRACK ADAPTER IAW SRM 51-72-10.SDR 04FDEA02067Seat Track · crackedMDC, LATERAL SEAT RACK AT FR 45 BETWEEN SEAT TRACKS R1 AND R2 HAS A POSSIBLE CRACK ON BOTTOM SIDE OUTBOARD END. REMOVED AND REPLACED SEAT TRACK ADAPTER IAW A310 SRM 51-72-10.SDR 04FDEA02066Floorbeam · corrodedUPPER MAIN CABIN ZONE 220 AT Y1959, FR14 TO 15A TOP OF FLOOR STRUCTURE HAS EXFOLIATION CORROSION. REMOVED AND REPLACED T-CAP IAW A310 SRM 51-40-20.SDR 04FDEA02065Floor Support · corrodedUPPER MAIN CABIN ZONE 220 AT Y1456 FR 15A - FR 14 TOP OF FLOOR STRUCTURE HAS EXFOLIATION CORROSION. REMOVED AND REPLACED T-CAP IAW A310 SRM 51-72-10, ZONE 220 AT Y1456 FR15A-FR14.SDR 04FDEA02064Seat Track · corrodedMDC, SEAT TRACK L3 AT FRAME 16 AND GOING FWD 16 INCHES HAS MODERATE LEVEL 2 SURFACE CORROSION. SEAT TRACK FR 16 L3 OUT OF LIMITS. SEAT TRACK REMOVED AND REPLACED IAW SRM 51-40-21. SEAT TRACK FABRICATION WAS ACCOMPLISHED ON N00428.SDR 04FDEA02063Seat Track · corrodedUPPER TRACK BREAK TO BREAK FR 69 TO 59.5, 6 EA PLACES AS MARKED FLOOR TRACKS HAVE LITE SURFACE CORROSION EACH APPROX 1 X 1 X 0.003 INCH DEPTH WITHOUT BLENDOUT, AND 1 EA GOUGE TOP SIDE OF TRACK AS MARKED (FR 60) 0.500 X 0.500 X 0.010 INCH DEPTH WITHOUT BLENDOUTSDR 04FDEA02062Seat Track · corrodedZONE 252, SEAT TRACK 2 RIGHT 4 INCHES AFT OF FR 72 HAS CORROSION ON TOP OF SCALLOPS. REMOVED AND REPLACED SEAT TRACK SECTION PER A310 SRM 53-10-16.SDR 04FDEA02061Seat Track · corrodedZONE 252, SEAT TRACK 2 RIGHT HAS THREE AREAS OF CORROSION BETWEEN FRAMES 69 TO 10 INCHES AFT OF FRAME 71, 12 INCHES AFT OF FR 69, 12 INCHES AFT OF FR 70, 8 INCHES AFT OF FR 71, ALL ON TOP OF SCALLOPS. REMOVED AND REPLACED SEAT TRACK IAW A310 SRM 51-72-10, NEWSDR 04FDEA02060Floorbeam · corrodedAFT CARGO LEFT SIDE FLOORBOARD SUPPORT CROSS MEMBER HAS EXFOLIATION CORROSION AT FRAME 60. CUT DAMAGED SECTION IAW A310-200 SRM 53-10-15, VERIFIED MAT'L TO FAB, FABBED REPAIR ANGLE AND FILLER, LOCATED, DRILLED DEBURRED AND COUNTERSUNK IAW A310 SRM 51-40-44. SDR 04FDEA02054Crossbeam · corrodedZONE 152, AFT CARGO FLOOR CROSS MEMBER BEAM, RT CENTER AT FR 58 CORRODED. REMOVED CORRODED BAD SECTION IAW A310-200 SRM 53-10-15 FIG 207. FABBED REPAIR ANGLE AND FILLER IAW A310-200 SRM 53-10-15. LOCATED, DRILLED, DEBURRED, AND COUNTERSUNK IAW A310-200 SRM SDR 04FDEA02047Computer · malfunctionedAFTER TAKEOFF NR 1 SYSTEM FAULT, FLAPS RETRACTED NORMAL FROM 20/20. NEXT RETRACTION GOT BOTH SYSTEM 1 & 2 FAULT. SLATS LOCKED AT 15 DEG. FOLLOWED QRH PROCEDURES, RECYCLED AND NO HELP. SET UP FOR SLATS 15 STUCK LANDING. SFCC NR 2 WAS REMOVED AND REPLACED DSDR 04FDEA01937Controller · malfunctionedON TAKEOFF DURING SLAT FLAP RETRACTION SYSTEM 2 FLAP FAULT LIGHT ON OVERHEAD PANEL CAME ON WITH ACCOMPANIED ECAM WARNING. ALSO, SPEED LIMIT WARNING (LOCATED AT THE BASE OF THE FIRST OFFICERS PFD CAME ON). SELECTED ADC INST ON FO'S SIDE SWITCHING PANEL AND SPSDR 04FDEA01560Warning System · faultyON CLIMBOUT PASSING 6800 FT GOT LEFT FWD COMP DOOR UNLOCK LIGHT (AMBER INDICATION). RETURNED TO LAS. ON APPROACH AT 4000 FEET LIGHT TURNED GREEN (DE-PRESSURIZED AT THIS POINT). LWR FD DOOR CLOSED & LOCKED INDICATION ON ECAM DOOR PAGE - INOP. LWR FD DOOR VISDR 04FDEA01415Warning System · activatedON DEPARTURE ECAM ALERT FLAPS SYS 2 FAULT. RECYCLED TO NO AVAIL. CATEGORY: C EXPIRATION: 01JUN04 "MEL 27-51-01-01: NR 2 SLATS / FLAPS CONTROL COMPUTER INOP. C/W PROCEDURES IN MEL 27-51-01-01, SYSTEM TESTS ARE OK. REMOVED & REPLACED NR 2 SFCC IAW A310 MM 27SDR 04FDEA01374Angle · damagedAFT PRESSURE BULKHEAD FR80 OUTER ANGLE LABELED LEFT NR 8 HAS INCOMING ELONGATED HOLES. FABBED REPLACEMENT ANGLE P/N A5398182321000 IAW ACFT DRAWING A53981823 ANGLE TO BE INSTALLED ON N CARD N00035 REF SDR 04-1346.SDR 04FDEA01351Pressure Blkhd · corrodedAFT PRESSURE BULKHEAD FR 80 LEFT WEB ASSY HAS AREAS OF EXCESSIVE CORROSION. FABRICATED NEW WEB IAW AIRBUS DRWG A53981860, INSTALLED NEW WEB ASSY IAW A310 SRM 51-40-21 ON ATTACH ANGLE. WORK PERFORMED ON NRC N00269.SDR 04FDEA01349Fitting · damagedSTRINGER 57 O/B END FITTING AT FRAME 80 HAS TWO ELONGATED HOLES. .300 X .280. .225 X .190. FABBED REPLACEMENT PART IAW AIRBUS DWG A53981973 ANGLE (END FITTING). ANGLE INSTALLED ON WORK CARD NON ROUTINE N00035.SDR 04FDEA01350Fitting · damagedSTRINGER 57 I/B END FITTING AT FRAME 80 HAS TWO ELONGATED HOLES. .300 X .200. .225 X .190. NO ACTION REQUIRED OLD PART IS BEING REPLACED AT STR 57 FR 80 REF DRAWING R53970100 ITEM 40 PART A5398020620300 REF N00035 FOR INSTALLATION OF END FITTING.SDR 04FDEA01347Angle · corrodedAFT PRESSURE BULKHEAD FR 80 INNER ANGLE LABELED LT NR 2 AND SHIM ARE CORRODED [EXFOLIATED]. REPLACED ANGLE AND SHIM ON FR 80 INNER ANGLE LT NR 2 IAW A310 SRM 51-72-10 AND 53-19-17.SDR 04FDEA01343Angle · corrodedAFT PRESSURE BULKHEAD FR 80 INNER ANGLE {LABELED NR 3} HAS EXFOLIATED CORROSION. REPLACED ANGLE ON FR 80 INNER ANGLE NR 3 LT IAW A310 SRM 51-72-10 AND 53-19-17.SDR 04FDEA01348Web · damagedWEBBING AT FRAME 80 HAS THREE ELONGATED HOLES COMMON TO STRINGER 57. .300 X .280 HOLE WITH ED OF .250 FROM CENTER. ELONGATED HOLE .225 X .190. ELONGATED HOLE .225 X .180.SDR 04FDEA01346Pressure Blkhd · corrodedREAR PRESSURE BULKHEAD FWD FACE ON THE AFT SIDE OF FR 82 FROM S38L TO S38R HAS AREAS OF CORROSION. LEVEL 2 CORROSION. REF N CARD N00035. COMPLIED WITH EA 6-5310-78353 PT1SDR 04FDEA01341Warning System · activatedENGINE NR 1 REVERSER UNLOCK LIGHT ILLUMINATED IN FLT, IT DID NOT FEEL AS IF THE REVERSER WAS DEPLOYED. COMPLIED WITH ECAM/PROCEDURES AND LANDED AT TUL. LIGHT WENT OUT AFTER ENGINE SHUTDOWN ON THE GROUND. RELEASED FOR SERVICE PER MEL/CDL: 78-30-01-B CATEGORSDR 04FDEA01287Bulkhead · corrodedAFT PRESSURE BULKHEAD FR 80 RIGHT WEB ASSY HAS AREAS OF CORROSION. INSTALLED NEW WEB ON ATTACH ANGLE IAW SRM 51-40-21. WORK PERFORMED ON NRC N00272.SDR 04FDEA01252Bulkhead · corrodedREAR PRESSURE BULKHEAD FWD FACE ON THE AFT SIDE OF FR 80/82 FROM S38L TO S38R HAS AREAS OF CORROSION. COMPLIED WITH EA 6-5310-78353 PT1.SDR 04FDEA01234Spar · corrodedRIGHT HORIZONTAL UPPER TRAILING EDGE SPAR I/B OF RIB 5 HAS LEVEL 2 CORROSION, APPROX 6 INCHES L X .800 INCH W, NOTE: PREVIOUS STRAP REPAIR INSTALLED I/B OF DAMAGE TO RIB 3. REMOVED PREVIOUS REPAIR, REMOVED CORROSION, MAT'L LOSS GREATER THAN 10 PERCENT, FABRISDR 04FDEA01215Attach Bracket · corrodedRIGHT SIDE OF VERTICAL STAB FROM RIB 22 TO 26 OF REAR SPAR HAS SEVERAL AREAS OF CORROSION ON FLANGES (PANEL ATTACH BRACKET). REMOVED CORROSION AT RT SIDE OF VERTICAL STAB REAR SPAR AREA, 3 AREAS NEEDED REWORK. FABRICATED & INSTALLED REPAIRS IAW EA 6-5530-776SDR 04FDEA01214Rib · corrodedRIGHT HORIZONTAL STAB END RIB UPPER AND LOWER FORMER PROFILE CORRODED. REMOVED CORROSION FROM RIGHT HORIZONTAL STAB, END RIB UPPER & LOWER FORMER PROFILES IAW A310-200 SRM 51-74-10. FABRICATED REPAIR STRAP & INSTALLED IAW EA 6-5510-77671.SDR 04FDEA01207Attach Angle · corrodedRT SIDE OF VERTICAL STAB T/E, AT RIB 26 TOP FLANGE (PANEL ATTACHMENT ANGLE BRACKET) HAS CORROSION ON INNER SIDE OF FLANGE. REPAIRED IAW EA 6-5530-77670A RT SIDE OF VERTICAL STAB T/E AT RIB 26 TOP FLANGE.SDR 04FDEA01160Frame · corrodedAVI BAY FROM FR 7 TO 10 STR 48L TO 48R E&E GROUND ACCESS DOOR CUTOUT SKIN SURFACE, FRAME ATTACHING SUPPORT ANGLES, PLATES, FITTINGS & FASTENERS HAVE CORROSION OVER ENTIRE CUTOUT AREA. REMOVED CORROSION AT AVI BAY FR 7 TO 10 STR 48L TO 48R, DOOR CUTOUT SKIN SUSDR 04FDEA01159Structure · corrodedLEFT HORIZONTAL STABILIZER FIXED LEADING EDGE, ZONE 330 (FWD SPAR) UPPER LIP UPPER SECTION APPROX STA 158 RIB 5, 4 EA AREAS 1.0 INCH L ,(.200 INCH W AREA 2 & 3 AS MARKED), (.100 INCH W AREA 1 & 4 AS MARKED). UNABLE TO DETERMINE DEPTH WITHOUT BLENDOUT, CORROSI
Back to Airbus A310-203