SDR WX0A2021072373785Epsu · no testEMERG BATTERY FIN 12WL FAILED CAP TEST OVERTEMP / REMOVED AND REPLACED EMERG BATTERY FIN 12WL IAW A319 AMM 33-51-38 OPS CHECK GOOD"SDR WX0A2021071973770Flashlight Assy · inoperativeFWD FA (INBOARD) EMERGENCY FLASHLIGHT NOT CHARGING. / R&R'D FWD FA (INBOARD) EMERGENCY FLASHLIGHT IN REF TO AMM 25-65-00. OPS CHECK GOOD."SDR WX0A2021071973772Warning Message · illuminatedAPPROXIMATELY 1 HOUR AFTER TAKEOFF ""WHEEL N/W STRG FAULT"" ECAM DISPLAYED AND REMAINED ON UNTIL RESET PER QRH ON THE GROUND. / "SDR WX0A2021071673767Warning Message · false activation(EMERGENCY DECLARED) APX 1 HOUR AFTER T/O, ""WHEEL N/W STRG FAULT"" ECAM DISPLAYED AND REMAINED ON UNTIL RESET PER QRH ON THE GROUND. / PERFORMED OPERATIONAL TEST OF THE NWS IAW AMM 32-51-00-710-001-A. OPS TEST PASSED. A/C GOOD FOR SERVICE."SDR WX0A2021071473765Engine · power loss(EMERGENCY DECLARED) #2 ENGINE ROLLED BACK DURING DECENT. ENGINE #2 WINDMILLED FOR ABOUT :17 MIN / AIRCRAFT IS CURRENTLY AOS AT TOL. TROUBLESHOOTING IN PROGRESS."SDR WX0A2021071273761Battery Pack · damagedFA REPORTS HIGH PITCH SQUEAL NEAR EMERGENCY EXITS. / FOUND HIGH PITCH QUEAL COMING FROM EMERGENCY LIGHT BATTERY PACK. REMOVED AND REPLACED EPSU IAW AMM 33-51-38-PB 401 CONF 00. OPS CHECK GOOD."SDR WX0A2021071273760Megaphone · damagedFWD CABIN MEGAPHONE IS COMING APART AND HAS CORRODED BATTERY TRAY. / REMOVED AND REPLACED FWD CABIN MEGAPHONE PER AMM 25-65-51. OPS CHECK GOOD."SDR WX0A2021063073751Epsu · failedREF NR 794471 CIDS1 EPSU SYS TEST FAILS AND DISPLAYS ESCAPE SLIDE LT/EPSU (10WL) FWD L MESSAGE CLASS 1; REQUIRES FURTHER TROUBLESHOOTING. / REPIN WIRE 5109 PIN B CONNECTOR 2871VC L DOOR SLIDE. OP TEST EPSU SYSTEM OK W/REF TSM 25-60-00-810-811A, ESPM 20-*48-14SDR WX0A2021062373747Power Supply · no testWAKING UP A/C NOTICED FWD EMERGENCY CABIN LIGHTS ON. / C/W OPS CHECK OF EMERGENCY POWER SUPPLY UNITS BY BITE CHECK REF A319 AMM 33-51-00-710-001A. EPSU BAT 10WL FAILED. REMOVED AND REPLACED EPSU BATTERY 10WL REF A319 AMM 33-51-38 PB401. OPS CHECK GOOD."SDR WX0A2021062173745Switch · faulted(EMERGENCY DECLARED) CLIMBING THROUGH FL 270 WE RECEIVE HYD Y RESVR LO LVL ECAM. ECAM LED UT TO SHUTDOWN PUT PUMP AND ENG 2 PUMP / FOUND YELLOW HYD RSVR LOW LEVEL SWITCH WITH LOW VOLTAGE. REMOVED AND REPLACED LOW LEVEL SWITCH IAW TSM 29-13-00-810-801-A AND ASDR WX0A2021061673742Epsu · no testEPSU BATTERY 13WL FAILED EPSU TEST. / REMOVED AND REPLACED ESPU BATTERY 13WL REF A319 AMM 33-51-38 PB401. OPS CHECK GOOD."SDR WX0A2021061473739Battery Pack · no testFAILED BATTERY CAPACITY CHECK ON 1A1 CHECK / REMOVED AND REPLACED BATTERY (FIN 10WL,FWD LEFT HAND) IAW AMM TASK 33-51-38-002-A, 33-51-38-400-002-A. OPERATIONAL CHECK COMPLETED"SDR WX0A2021061173735Battery Pack · no testEPSU BATTERY FAILED MCDU TEST (FIN 10WL) / REMOVED AND REPLACED EPSU BATTERY(FIN 10WL) IAW AMM 33-51-38-000-002-A/33-51-38-400-002-A; OP'S CHECK GOOD"SDR WX0A2021060773733Sign · brokenCABIN WALL-MOUNTED EMERGENCY LENS EXIT SIGN L/H AFT BROKEN. / REMOVED AND REPLACED EMERGENCY LENS EXIT SING L/H AFT IAW AMM 33-51-13. OPS CHECK GOOD."SDR WX0A2021060773734Hydraulic System · leaking(EMERGENCY DECLARED) OTHER AIRCRAFT AND FA'S REPORTED SOMETHING LEAKING FROM RT WING IN FLIGHT. / COMPLIED WITH A.M.M. 29-00-00-790-001A CHECK OF THE EXTERNAL LEAKS OF THE HYDRAULIC COMPONENTS. FOLLOWING CREW OBSERVATIONS OF RIGHT WING SUBSTANCE, EXERCISED FLISDR WX0A2021060273729Battery · no testEPSU BATTERY FAILED MCDU TEST (FIN 13WL) / REMOVED AND REPLACED EPSU BATTERY(FIN 13WL) IAW AMM 33-51-38-000-002-A/33-51-38-400-002-A; OP'S CHECK GOOD"SDR WX0A2021051973719Battery Pack · no testEPSU BATTERIES FAILED ON BOTH OVERWING (FIN 11WL/12WL) DURING EPSU BATTERY TEST / REMOVED AND REPLACED BOTH OVERWING EPSU BATTERIES IAW AMM 33-51-38-000-002-A/33-51-38-400-002-A; OP'S CHECK GOOD"SDR WX0A2021051973718Lamp · no testEMERGENCY OVERWING EXTERIOR LIGHTS FAILED MCDU EPSU TEST / RELAMPED ALL EMERGENCY OVERWING EXTERIOR LIGHTS (FIN 60WL,62WL, 61WL, 63WL) IAW AMM 33-51-15-000-001-A/ 33-51-15-400-001-A; OP'S CHECK GOOD."SDR WX0A2021051473715Epsu · no testFAILED CAP CHECK @ POSITIONS 10WL, 11WL, 12WL, AND 13WL DURING EMERGENCY LIGHT TASK CARD 335100-03-1-001 ON 1A PHASE CHECK / REMOVED AND REPLACED EMERGENCY LIGHT BATTERIES @ POS. 10WL, 11WL, 12WL, AND 13WL REF AMM 33-51-38 PB401. OPS CHECKS/BITE TESTS GOOD."SDR WX0A2021051073710Epsu · inoperativeFWD EPSU 10WL BATTERY FAULT / REMOVED AND REPLACED FWD EPSU (10WL) BATTERY IAW A319 AMM 33-51-38 PB 401. OPS CHECK GOOD.SDR WX0A2021050373702Light · malfunctionedAIRCRAFT RIGHT OVER WING ""EXIT"" LIGHT INOP, CYCLED EMER EXIT LT SWITCH. SYSTEM RETURNED TO NORMAL OPERATION. / CREW RESET NOTED"SDR WX0A2021050373701Cover · missing12A EXIT LIGHT CORE MISSING / INSTALLED EXIT LIGHT COVER AT ROW 12ABC IAW 33-51-13 PB401"SDR WX0A2021042873693Epsu · overtempDURING 1A CHECK FOUND EMERG BATTERY 12WL OVER TEMP / REMOVED AND REPLACED EMERGENCY EXIT LIGHTING BATTERY ESPU (12WL) IAW A319 AMM 33-51-38 BITE CHECK FOOD"SDR WX0A2021042873692Epsu · overtempDURING 1A CHECK FOUND EMERG BATTERY 11WL OVER TEMP / REMOVED AND REPLACED EMERGENCY EXIT LIGHTING BATTERY ESPU (11WL) IAW A319 AMM 33-51-38 BITE CHECK GOOD"SDR WX0A2021042873691Epsu · no testFWD EPSU BATTERY 10WL FAILED EPSU TEST / R/R FWD EPSU BATTERY 10WL IAW AMM 33-51-38 PB401. OPS CHECK GOOD."SDR WX0A2021042873690Epsu · no testAFT EPSU BATTERY 13WL FAILED EPSU TEST / R/R AFT EPSU BATTERY 13WL IAW AMM 33-51-38 PB401. OPS CHECK GOOD."SDR WX0A2021042373685Epsu · faultedEPSU BATTERY AT FIN 12 WL FAULT / REMOVED AND REPLACED EPSU BATTERY ON FIN 12WL, OPS CHECK GOOD, W/REF TO AMM 33-51-38 PB 401"SDR EE4Y2021041912671Skin · corrodedDURING MAINTENANCE ACCOMPLISHMENT WERE FOUND CORROSION LOCATED AT LH WING BOX TOP PANEL #2 STR 11, RIB 5, OUT OF ALLOWABLE DAMAGES LIMITS AS PER A319 SRM TASK 57-21-11-283-014, DUE TO THIS FACT DETAILS WERE SENT TO AIRBUS, REPAIR APPROVED UNDER DOSSIER 8090905SDR EE4Y2021041912672Buttstrap · corrodedDURING MAINTENANCE ACCOMPLISHMENT WERE FOUND CORROSION LOCATED AT AFT CARGO COMPARTMENT INTERNAL JOINT STRAP AT FR64 BETWEEN STR43RH AND STR41LH, NOT FOUND APPROVE DATA TO THE DAMAGE AREA, DUE TO THIS FACT DETAILS WERE SENT TO AIRBUS, REPAIR APPROVED UNDER DOSSDR WX0A2021041673684Battery Pack · no testESPU (13WL) BATT FAILED ""CABIN EMERGENCY LIGHTING"" WORK CARD 335100-03-1-001. / REPLACED EPSU (13WL) BATT, BITE CHECKED NORMAL, IAW TSM 33-51-00-810-857-A & AMM 33-51-38-400-002-A."SDR WX0A2021041473682Epsu · no testEPSU BATT (11WL) FAILED EPSU TEST. REPLACED EPSU BATT (11WL) W/REF TO AMM 33-51-38 PB 401. OPS CHECK GOOD.SDR WX0A2021040573678Epsu · no testFWD L/H (10WL) EMERGENCY LIGHT BATTERY PACK DISPLAYS FAILED ON EMERGENCY LIGHT TEST / REMOVED AND REPLACED FWD L/H (10WL) EMERGENCY LIGHT BATTERY PACK PER AMM 33-51-38-000-002-A AND 33-51-38-400-002-A OPS CHECK GOOD."SDR WX0A2021040573677Power Supply · inoperativeEMER R (12WL) AND AFT L/H (13WL) EMERGENCY LIGHT BATTERY PACK DISPLAYS FAILED ON EMERGENCY LIGHT TEST / REMOVED AND REPLACED EMER R (12WL) AND AFT L/H (13WL) EMERGENCY LIGHT BATTERY PACK PER AMM 33-51-38-000-002-A AND 33-51-38-400-002-A."SDR WX0A2021040273676Power Supply · no testCIDS EPSU SYS TEST FAULTING EPSUC (12WL) / REPLACED EPSU-POWER SUPPLY UNIT, OPS CHECK GOOD, REF AMM 33-51-38"SDR WX0A2021032473666Epsu · faultedL/H FWD EMERGENCY LIGHT POWER SUPPLY SHOWS FAULTY ON MCDU BITE. / REPLACED L/H FWD EMERGENCY LIGHT POWER PACK PER AMM 33-51-38 P/B 401. TESTS GOOD, OK FOR SERVICE."SDR WX0A2021031773663Epsu · no testEPSU BATTERY (12WL) FAILED OP'S CHECK VIA MCDU / REMOVED AND REPLACED EPSU BATTERY (12WL) IAW AMM 33-51-38-000-002-A/33-51-38-400-002-A; OP'S CHECK GOOD"SDR WX0A2021031273660Light · faultedNOTICED LH EXIT ROW EMERG LIGHTS REMAIN ILLUMINATED-BITE CK EPSU SYS TEST WITH FAULTS 11WL/DEUB. / "SDR WX0A2021021973649Epsu · no testEMERGENCY LIGHT POWER SUPPLY [EPSU] 11WL FAILS TEST / REMOVED AND REPLACED EPSU [11WL] PER AIRBUS AMM 33-51-38-000-002-A, 33-51-38-400-002-A, 33-51-00-710-001.OPS CHECK GOOD.SDR EE4Y2021021512334Skin · dentedDURING MAINTENANCE ACCOMPLISHMENT WERE FOUND (2EA) DENTS LOCATED ON CONE REAR LOWER FUSELAGE AFT FR73, BTWN S-28R AND S-31R, OUT ALOOWABLE DAMAGES LIMITS, DUE TO THIS FACT DETAILS WERE SENT TO AIRBUS, REPAIR APPROVED UNDER DOSSIER 80881489 AND APPROVED UNDER RSDR WX0A2021021573643Skin · dentedCONE REAR LOWER FUSELAGE 70MM AFT OF FR73, 55MM BELOW OF THE STR 28RH SKIN WITH DENT. / PERFORMED PERMANENT REPAIR AT REAR CONE LWR FUSELAGE AFT FR73, SGTR28R, STGR31R I.A.W ERO # R5341-0039 REV 00. THIS IS A MAJOR PERMANENT REPAIR.SDR WX0A2021021573642Skin · dentedUPPER REAR FUSELAGE BETWEEN FR69 - FR69+300MM AND STR 19LH - STR 20LH SKIN WITH DENTS. / PERFORMED TEMPORARY REPAIR AT AFT FUSELAGE FR69-70, STGR 18LH-21LH MULTIPLE DENTS IN SKIN I/A/W ERO NO. R5341-0038. IS A MAJOR TEMPORARY REPAIR.SDR WX0A2021021573647Skin · dentedCONE REAR LOWER FUSELAGE 180MM AFT OF FR73, 55MM BELOW OF THE STR 30 RH SKIN WITH DENT. / PERFORMED PERMANENT REPAIR AT REAR CONE LWR FUSELAGE AFT FR73,STGR28R, STGR31R I.A.W ERO. # R5341-0039. THIS IS A MAJOR PERMANENT REPAIR CATEGORY A.SDR WX0A2021021573646Skin · dentedCONE REAR LOWER FUSELAGE 70MM AFT OF FR73, 55MM BELOW OF THE STR 28RH SKIN WITH DENT. / PERFORMED PERMANENT REPAIR AT REAR CONE LWR FUSELAGE AFT FR73, SGTR28R, STGR31R I.A.W ERO # R5341-0039 . THIS IS A MAJOR PERMANENT REPAIR "SDR WX0A2021021573645Skin · dentedUPPER REAR FUSELAGE BETWEEN FR69 - FR69+300MM AND STR 19LH - STR 20LH SKIN WITH DENTS. /PERFORMED TEMPORARY REPAIR AT AFT FUSELAGE FR69-70, STGR 18LH-21LH MULTIPLE DENTS IN SKIN I/A/W ERO NO. R5341-0038. THIS IS A MAJOR TEMPORARY REPAIR CATEGORY C"SDR WX0A2021021573644Skin · dentedCONE REAR LOWER FUSELAGE 70MM AFT OF FR73, 55MM BELOW OF THE STR 28RH SKIN WITH DENT. / PERFORMED PERMANENT REPAIR AT REAR CONE LWR FUSELAGE AFT FR73,STGR28R, STGR31R I.A.W ERO. # R5341-0039. THIS IS A MAJOR PERMANENT REPAIR .SDR EE4Y2023031017354Skin · dentedDURING THE VISUAL INSPECTION PER ALLEGIANT TASK CARD ZL-200-02-1-001_P1-VISUAL, MULTIPLE DENTS WERE FOUND COMMON TO REAR FUSELAGE UPPER SKIN BETWEEN FR69 AND FR70 AND BETWEEN STR 19L AND 20L, DENTS WERE EVALUATED AND DETERMINED AS OUT OF A319-SRM LIMITS. CORRSDR EE4Y2023031017353Skin · dentedDURING VISUAL INSPECTION PER ALLEGIANT TASK CARD 51-000-001_P1-VISUAL INSP. THERE WERE FOUND TWO DENTS COMMON TO THE FUSELAGE REAR CONE LOWER SKIN, BETWEEN FR73 AND FR74 AND BETWEEN STR 28R AND STR 31R, DENTS WERE EVALUATED AND DETERMINED AS OUT OF SRM LIMITS.SDR EE4Y2023031017355Elevator · gougedDURING THE INSPECTION PER ALLEGIANT TASK CARD ZL-300-02-1-001_D-1/008, AT LH ELEVATOR IT WAS FOUND THE T/E ALUMINUM PROFILE WITH GOUGE AT 1005MM O/B FROM ELEVATOR RIB 5. CORRECTIVE ACTION: PERMANENT REPAIR WAS PERFORMED AS PER A319 SRM TASK 55-21-11-300-028 PSDR WX0A2021011173627Power Supply · faultedEMERGENCY BATTERY EPSU (11WL) FAULT. REMOVED AND REPLACED EMERGENCY BATTERY EPSU (11WL), IAW AMM 33-51-38 PB 401. OPERATIONS CHECK GOOD.SDR WX0A2021010473625Battery Pack · faultedEPSU BATTERY 11WL FAULT. REMOVED AND REPLACED BATTERY 11WL, IAW AMM 33-51-38 PB 401. OPERATIONS CHECK GOOD.
Back to Airbus A319-111