Airbus A319-111
Service difficulty reports · 2,475
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319111' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319111' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR WX0A2020121673620Power Supply · no testEPSU BATTERIES 10WL, 11WL, 12WL FAILED CABIN EMERGENCY LIGHTING CAPACITANCE TEST. REPLACED ALL 3 EPSU BATTERIES 10WL, 11WL, 12WL W/REF TO AMM 33-51-38 PB 401. OPERATIONS CHECK GOOD. OK FOR SERVICE.SDR WX0A2020121573618Power Supply · no testWEEKLY CHECK CIDS1 EPSU SYS TEST BAT/EPSU 11WL FAILED TEST. REMOVED AND CLEANED CONNECTOR AT L MID BATT 11WL AND MESSAGE CLEARED FROM CIDS1, TEST OK REF TC 05-000-002 AND AMM 33-51-00. ALSO REF ESPM 20-55-40.SDR WX0A2020121573619Power Supply · no testBATTERY ON EPSU 10WL FAILED EMERGENCY LIGHT TEST. REMOVED AND REPLACED EPSU BATTERY 10WL, IAW A319 AMM 33-51-38 PB 401. OPERATIONS CHECK GOOD.SDR WX0A2020112773609Connector · disconnectedEPSU TEST FAILS 13WL AFT LT EMERGENCY SLIDE LT. PERFORMED TSM 25-62-00-810-819-A REMOVED AND REPLACED 13WL ESPU AND FAILS EXTERIOR LIGHTS. CONTINUED TROUBLESHOOTING AND FOUND CONNECTER UNDER SLIDE COVER AT L2 DOOR SLIDE DISCONNECTED. RECONNECTED SLIDE WIRE SDR WX0A2020112073607Epsu · no testEMERGENCY LIGHT BATTERY FAILED AT FIN (10WL) DURING EPSU TEST. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY AT FIN (10WL), IAW AMM 33-51-38-000-002-A/33-51-38-400-002-A. OPERATIONS CHECKED GOOD.SDR WX0A2020112073606Power Supply · failedEMERGENCY LIGHT BATTERY FAILED AT FIN (11WL) DURING EPSU TEST. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY AT FIN (10WL), IAW AMM 33-51-38-000-002-A/33-51-38-400-002-A. OPERATIONS CHECKED GOOD.SDR WX0A2020111373602Power Supply · no testEMERGENCY LIGHT ESPU TEST FAILS 12WL LOCATION. REMOVED AND REPLACED BATTERY ON ESPU AT 12WL, IAW MM 33-51-38-000-002-A AND MM 33-51-38-400-002-A. OPERATIONS CHECKED GOOD, IAW MM 33-51-00-710-001-A.SDR WX0A2020111373603Battery Pack · no testEPSU BATTERY AT 12WL SHOWS FAULT ON CIDS EPSU TEST RESULTS. REMOVED AND REPLACED EPSU (12WL) AT RT OFFWING EMERGENCY EXIT, IAW A319 AMM 33-51-38 PB 401. OPS CHECK GOOD.SDR WX0A2020111173600Battery · no testRIGHT OVERWING EPSU BAT FAILED EPSU SYSTEM TEST. REMOVED AND REPLACED EPSU BATTERY, IAW AMM 33-51-38-000-002-A AND AMM 33-51-38-400-002-A. OPERATIONS CHECK GOOD.SDR WX0A2020101973592Epsu · no testEMERGENCY POWER SUPPLY UNIT FAILED BATTERY TEST. REMOVED AND REPLACED 12WL (RT) EMERGENCY POWER SUPPLY UNIT, IAW AMM 33-51-38-000-002 AND 33-51-38-400-002. OPERATIONS CHECK GOOD.SDR WX0A2020101973591Epsu · no testEMERGENCY POWER SUPPLY UNIT 13WL FAILED EPSU BAT CAP TEST. REMOVE EMERGENCY POWER SUPPLY UNIT 13WL AMM 33-51-38-000-001-A AND INSTALL 33-51-38-400-001-A. BITE TEST GOOD, AMM 33-51-00-710-001-A.SDR WX0A2020101473588Power Supply · no testEPSU BAT (12WL) FAILED EPSU BAT CAP TEST. REPLACED EPSU BAT (12WL), IAW AMM 33-51-38 PB 401. OPERATIONAL CHECK GOOD.SDR WX0A2020100573585Power Supply · no testL2 & R2 EXIT SIGN LIGHTS INOPERABLE. PERFORMED EPSU SYS TEST AND TSM 33-51-00-810-859-A. REMOVED AND REPLACED EPSU (12WL), IAW AMM 33-51-38 PB 401. OPS CHECK GOOD.SDR WX0A2020100573584Battery Pack · no testEMERG LIGHTS BATTERY (11WL) FAILED ON CIDS TEST, PER WEEKLY CHECK. REMOVED AND REPLACED EPSU BATTERY PACK (FIN 11WL) ON A/C LEFT, OVER WING. TESTED GOOD, IAW AMM 33-51-38-000-002-A/33-51-38-400-002-A.SDR WX0A2020092873582Battery Pack · no testEMERGENCY LIGHTING BATTERY RT FIN (12WL) ECAM FAILURE MESSAGE ON START OF BATTERY CAP TEST. NEEDS TO BE REPLACED BEFORE BATTERY CAP TEST CAN START AND CONTINUE. REMOVED EMERGENCY POWER SUPPLY BATTERY FROM RT POWER SUPPLY, IAW AMM 33-51-38-000-002-A AND INSTASDR WX0A2020091473573Epsu · no testAFT EPSU BATTERY (13WL) FAILED OPS TEST OF CABIN EMERGENCY LIGHTS. REPLACED AFT EPSU (13WL) IAW AMM 33-51-38 PB 401, OPS CHECK GOOD.SDR WX0A2020091173570Power Supply · no testEPSU BITE TEST SHOWS 13WL FAILS. FOUND EPSU BATT FAILED AT 13WL. REMOVED AND REPLACED BATT PACK AND OPS CK GOOD, BITE TEST GOOD. REF AMM 33-51-38 PB 401.SDR WX0A2020091173569Epsu · failedEMERGENCY LIGHTS CHECK FAULTS ESPU 11WL LOCATION. REPLACED BATTERY ON ESPU 11WL LOCATION, IAW MM 33-51-38-000-002-A AND MM 33-51-38-400-002-A. OPS CHECKED GOOD, IAW MM 33-51-00-710-001-A.SDR WX0A2020082673564Battery Pack · no testDURING ESPU BATTERY CHECK. BATTERY AT POSTION 12WL SHOWING FAILED ON MCDU / REMOVED AND REPLACED ESPU BATTERY AT POSTION 12WL IAW AMM 33-51-38-00-002-A AND AMM 33-51-38-400-002. OPS CHECK GOOD."SDR WX0A2020082673563Battery Pack · no testAFT EMERGENCY LIGHT BATTERY FAIL CAP CHECK / REMOVED AND REPLACED AFT EMERGENCY LIGHT BATTERY REF AMM 33-51-38 PB401. OPS CHECK GOOD."SDR WX0A2020082673562Battery Pack · no testDURING WEEKLY EPSU TEST BATTERY 11WL FLAGGED DURING TEST. REMOVED AND REPLACED EPSU BATTERY 11WL REF A319 AMM 33-51-38 PB 401. OPS CHECK GOOD.SDR WX0A2020081973557Battery Pack · no testPERFORM A CABIN EMERGENCY LIGHTING TEST. BATTERY EPSU 11WL EMER L AND BATTERY EPSU 13WL AFT L AND BATTERY EPSU 12WL EMER R FAILED. / R/R EMERGENCY BATTARIES PER AMM 33-51-38-000-002-A AND 33-51-38-400-002-A."SDR WX0A2020081973556Battery Pack · no testEPSU BATTERIES FAILED EPSU CAPACITANCE CHECK. / REMOVED AND REPLACED EPSU BATTERIES (10WL) (11WL) (12WL) (13WL) IAW AMM 33-51-38 PB 401. OPS CHECK GOOD. OK FOR SERVICE."SDR WX0A2020081773554Switch · failedL1 DOOR EMERGENCY SLIDE WILL NOT ARM / REMOVED AND REPLACED SWITCH 4WN1 IAW AMM 52-73-11-000-001 AND AMM 52-53-11-400-001. OPS TEST GOOD"SDR WX0A2020081073550Battery Pack · no testEPSU BATTERY (11WL) FAILED EPSU SYSTEM TEST / REMOVED AND REPLACED EPSU BATTERY IAW AMM 33-51-38-000-002-A AND AMM 33-51-38-400-002-A. OPS CHECK GOOD"SDR WX0A2020080573548Relay · inoperativeEMERGENCY EXIT SIGNS THROUGHOUT CABIN KEEP FLICKERING ON AND OFF DURING FLIGHT / PERFORMED TSM 33-51-00-810-819-A R&R RELAY 8WL IAW ESPM 20-46-50. NO FURTHER FAULTS NOTED."SDR WX0A2020080573547Power Supply · inoperativeEMERGENCY EXIT LIGHT EPSU TEST FAILS 11WL LEFT EMERG EXIT. REMOVED AND REPLACED 11WL EPSU AND BITE CHECKED GOOD. EPSU TEST OK. IAW AMM 33-51-38-000-001-A, AND 33-51-58-400-001-A."SDR WX0A2020080573546Battery Pack · inoperativeDURING EPSU BATTERY TEST EPSU 13WL BATTERY FAULT LIGHT ILLUMINATED. REMOVED AND REPLACED EPSU 13WL BATTERY REF AMM 33-51-38 PB401. OPS CHECKED GOOD.SDR WX0A2020080373542Battery Pack · no testCABIN EMERGENCY BATTERY CLASS 1 FAULT AFT L (13WL) / REMOVED AND REPLACED AFT L EMERGENCY SUPPLY BATTERY UNIT IAW AMM 33-51-000-002-A AND 33-51-38-400-002-A. OPS CHECK GOOD"SDR WX0A2020073173537Battery Pack · not reportedEPSU BATTERY (12WL) REQUIRES REPLACEMENT. REPLACED EPSU BATTERY (12WL) IAW AMM 33-51-38 PG 401. OPS CHECK GOOD."SDR WX0A2020072773535Battery · inoperativeAFT F/A EMERGENCY FLASH LIGHT RED LED IS NOT REPORTING / REPLACED FLASH LIGHT BATTERY AND OPS CHECK GOOD IAW AMM 25-64-00"SDR WX0A2020072473532Controller · malfunctionedDESCENDING THROUGH APPROXIMATELY FL320 RECEIVED ECAM CAB PR EXCESS CAB ALT AND COMPLIED WITH THOSE PROCEDURE. CABIN PRESSURE GOT AS HIGH AS 12500 FT. MASK DID NOT DEPLOY. OTHER ECAM THAT FOLLOWED WERE CABPR LO DIFF PR, DOOR R AFT CABIN, AND CAB PR SAFETY VALVSDR WX0A2020072473531Epsu · no testCABIN EMERGENCY LIGHTING, TEST SHOWS FAULT OF EPSU(13WL)AFT L / T/S PER TSM 33-51-00-810-857-A.CONFIRMED FAULT OF EPSU FIN 13WL. R/R EPSU BATTERY PER AMM 33-51-38. OPS CHK GOOD"SDR WX0A2020071500001Switch · malfunctionedEMER EXIT LLT ILLUMINATED IN FLT, NO ASSOCIATED TRIGGER. FOLLOWED 33-51-00-810-881-A, REPLACED COCKPIT SW (4WL). PERFORMED BITE, AMM 33-51-00-710-001-A AND OPS CHECK, AMM 33-51-00-710-004-A. CHECKS PASS "OK". GOOD FOR SERVICE.SDR WX0A2020072273528Switch · malfunctionedEMERGENCY EXIT LIGHT ILLUMINATED IN FLT - NO ASSOCIATED TRIGGER, FOLLOWED 33-51-00-810-881-A, REPLACED COCKPIT SWITCH (4WL). PERFORMED BITE, AMM 33-51-00-710-001-A AND OPS CHECK, AMM 33-51-00-710-004-A. CHECKS PASSED, GOOD FOR SERVICE.SDR WX0A2020062673519Battery Pack · no testEPSU BATTERY FIN 10WL FAILED THE EPSU BATTERY CAPACITY TEST. REPLACED EPSU BATTERY.SDR WX0A2020062473517Battery Pack · no testEPSU BATTERY FIN# 10WL FAILED EPSU BAT CAP TEST. REPLACED EPSU BATTERY.SDR WX0A2020052537508Battery Pack · no testEPSU BATTERY FIN# 10WL FAILED EPSU CAPACITY TEST. REPLACED THE EPSU BATTERY.SDR WX0A2020052273507Epsu · failedEPSU BATTERY FIN# 10WL FAILED EPSU BAT CAP TEST / REPLACED EPSU BATTERY"SDR WX0A2020051573503Battery · dischargedEPSU BATTERY FIN# 13WL FAILED EPSU BAT CAP TEST / REPLACED EPSU BATTERY"SDR WX0A2020051573504Battery · dischargedEPSU BATTERY FIN# 12WL FAILED EPSU BAT CAP TEST / REPLACED EPSU BATTERY"SDR WX0A2020050873500Battery · dischargedEPSU BATTERY FIN# 10WL FAILED EPSU BAT CAP TEST / REPLACED EPSU BATTERY"SDR WX0A2020032373490Battery Pack · failedEPSU FAILED EMERGENCY LIGHTING TEST / REPLACED EMERGENCY BATTER PACK "SDR 2020F00110None · noneMIC # 38937815 //// 2610 1 OPEN MIA 18MAR20 SMOKE FWD , AFT CRG BTL FAULT. MIC # 38937814 /////2610 1
OPEN MIA 18MAR20 SMOKE AFT CARGO WARNING NUMEROUS TIMEDURING FLIGHT
, ATTEPTED TO RUN ECAM AND WOULD GO AWAY. FINAL
WARNING RETURNED AND COMPLETED ECAMSDR WX0A2020022673483Power Supply · no testEMERGENCY POWER SUPPLY FAILED DURING LIGHTING CK /REPLACED EMERGENCY POWER SUPPLY"SDR WX0A2020022673482Power Supply · no testEMERGENCY POWER SUPPLY FAILED DURING LIGHTING CK /REPLACED EMERGENCY POWER SUPPLY"SDR WX0A2020022073474Epsu · no testWHILE PERFORMING EMERGENCY LIGHT TEST GOT A BAT/ EPSU 13WL AFT L MSG. / REPLACED EPSU BATTERY ON EPSU"SDR WX0A20200219475Power Supply · no testWHILE PERFORMING EMERGENCY LIGHT TEST GOT A BAT/ EPSU 13WL AFT L MSG. / REMOVED AND REPLACED EPSU BATTERY ON EPSU 13WL REF A319 AMM 33-51-58 PB401. OPS CHECK GOOD."SDR WX0A2020022073473Epsu · no testL/H OVERWING EPSU BATTERY (11WL) FAILED EPSU TEST. / REPLACED EPSU BATTERY"SDR WX0A2020021273472Control Unit · malfunctionedEMERGENCY DECLARED) ON APPROACH RECEIVED ECAM F/CTL FLAPS FAULT / REPLACED FLAP-PCU"
Back to Airbus A319-111