Service difficulty reports · 2,475
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319111' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319111' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR F3LA2008100600670Plate · corrodedDURING C3 C-CHECK, INSPECTION NOTED L-2 GIRT BAR FITTINGS ATTACH PLATE HOLES HAVE CORROSION. MAINTENANCE FABRICATED REPAIR DOUBLER AND FILLER, TREATED, PRIMED, PAINTED AND INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ENGINEERING AUTHORIZATION A9-53R-30662.SDR F3LA2008100600669Plate · corrodedDURING C3 C-CHECK, INSPECTION NOTED THE L-2 FORWARD GIRT BAR FITTING BLANKING PLATE HAS CORROSION ON CORNER. MAINTENANCE REMOVED AND REPLACED L-2 DOOR FORWARD GIRT BAR FITTING BLANKING PLATE IN ACCORDANCE WITH THE REQUIREMENTS OF A319 AMM 52-13-31-400-007.SDR F3LA200800652Skin Panel · dentedREFERENCE NON ROUTINE 2008-196216. DURING C4/S1 C CHECK, INSPECTION NOTED DENT ON FUSELAGE SKIN AT FRAME 63 + 9 INCHES AND LT STRINGER 43 + 1 INCH. MX REPAIRED DENT ON EXTERNAL SKIN AT FRAME 63 + 9 INCHES BETWEEN LT STRINGER 41 AND RT STRINGER 43, IAW THE RESDR F3LA2008100700672Blanking Plate · corrodedDURING C3 C-CHECK, INSPECTION NOTED THE R2 DOOR AFT GIRT BAR FITTING BLANKING PLATE IS CORRODED ON LOWER SURFACE. MAINTENANCE REMOVED GIRT BAR BLANKING PLATE AND INSTALLED NEW, REFERENCE WORK CARD C534103-01.SDR F3LA2008100700671Blanking Plate · corrodedDURING C3 C-CHECK, INSPECTION NOTED THE R2 FORWARD DOOR GIRT BAR FITTING BLANKING PLATE IS CORRODED ON UPPER AND LOWER SURFACE. MAINTENANCE REMOVED CORRODED GIRT BAR BLANKING PLATE AND INSTALLED NEW, REFERNCE WORK CARD C534103-01.SDR F3LA200800651Skin · dentedDURING C4/S1 C-CHECK, INSPECTION NOTED DENT ON TOP SKIN OF LT SLAT NR 3 BETWEEN RIB 3 AND 4. MX REPAIRED THE DENT IAW THE REQUIREMENTS OF A319 SRM 57-40-00, FIGURE 224. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800650Floor Panel · corrodedDURING C4/S1 C-CHECK, INSPECTION NOTED CORROSION ON FLOOR PANEL 222FF, FWD GALLEY AREA. MX REMOVED AND REPLACED THE FLOOR PANEL IAW THE REQUIREMENTS OF A319 SRM 53-12-12-000-001. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800649Floor Panel · corrodedDURING C4/S1 C-CHECK, INSPECTION NOTED CORROSION ON FLOOR PANEL 221FF, FWD GALLEY AREA. MX REMOVED AND REPLACED THE FLOOR PANEL IAW THE REQUIREMENTS OF A319 SRM 53-12-12-000-001. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800637Shear Plate · corrodedDURING C4/S1 C-CHECK, INSPECTION NOTED CORROSION ON SHEAR PLATE LOCATED AT FRAME 69 TO FRAME 70 ON THE RIGHT SIDE OF THE PASSENGER CABIN. MX REMOVED AND REPLACED THE SHEAR PLATE IAW THE REQUIREMENTS OF A319 SRM 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS SDR F3LA200800638Floor Panel · delaminatedDURING C4/S1 C-CHECK, INSPECTION NOTED DELAMINATION ON FLOOR PANEL 162EF IN THE AFT CARGO COMPARTMENT. MX REMOVED AND REPLACED THE FLOO PANLE IAW THE REQUIREMENTS OF A319 SRM 53-02-00, TABLE 105. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCESDR F3LA200800628Flap · damagedLINE MX NOTED DAMAGE FROM A BIRD STRIKE ON THE LEADING EDGE OF THE LT WING OUTBOARD FLAP. MX REPAIRED FLAP IAW THE REQUIREMENTS OF A319 SRM 57-53-00, FIGURE 202. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800635Floorbeam · corrodedDURING C4/S1 C-CHECK, INSPECTION NOTED CORROSION ON PASSENGER CABIN FLOORBEAM Y1732 AT FRAME 66. MX REPAIRED FLOORBEAM Y1732 AT FRAME 66 IAW THE REQUIREMENTS OF A319 SRM 53-41-14, FIGURE 201. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABSDR F3LA200800648Floor Panel · perforatedDURING C4/S1 C-CHECK, INSPECTION NOTED FLOOR PANEL 131CG WAS PERFORATED. MX REPAIRED THE FLOOR PANEL IAW THE REQUIREMENTS OF A319 SRM 53-02-00 PARA 8C. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800642Floor Panel · damagedDURING C4/S1 C-CHECK, INSPECTION NOTED FLOOR PANEL 151TG WAS DAMAGED. MX REMOVED AND REPLACED THE FLOOR PANEL IAW THE REQUIREMENTS OF A319 SRM 53-02-00. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800641Floor Panel · delaminatedDURING C4/S1 C-CHECK, INSPECTION NOTED DELAMINATION ON FLOOR PANEL 151DE. MX REMOVED AND REPLACED THE FLOOR PANEL IAW THE REQUIREMENTS OF A319 SRM 53-02-00. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800640Floor Panel · delaminatedDURING C4/S1 C-CHECK, INSPECTION NOTED DELAMINATION ON FLOOR PANEL 151TG. MX REMOVED AND REPLACED THE FLOOR PANEL IAW THE REQUIREMENTS OF A319 SRM 53-02-00. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800629Floorbeam · corrodedDURING C4/S1 C-CHECK, INSPECTION NOTED CORROSION ON PASSENGER CABIN FLOORBEAM Y765 AT FRAME 67+10 INCHES. MX REMOVED AND REPLACED FLOORBEAM AT FRAME 67 IAW THE REQUIREMENTS OF A319 SRM 51-72-11, PAGE 1 AND 2. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED ASDR F3LA200800634Floorbeam · corrodedDURING C4/S1 C-CHECK, INSPECTION NOTED CORROSION ON PASSENGER CABIN FLOORBEAM Y1292 AT FRAME 68. MX REMOVED AND REPLACED FLOORBEAM Y1292 AT FRAME 68 IAW THE REQUIREMENTS OF A319 SRM 51-72-11. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABSDR F3LA200800633Floorbeam · corrodedDURING C4/S1 C-CHECK, INSPECTION NOTED CORROSION ON PASSENGER CABIN FLOORBEAM Y765 AT FRAME 68. MX REMOVED AND REPLACED FLOORBEAM AT FRAME 66 TO FRAME 70 IAW THE REQUIREMENTS OF A319 SRM 51-72-11. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCSDR F3LA200800632Floorbeam · corrodedDURING C4/S1 C-CHECK, INSPECTION NOTED CORROSION ON PASSENGER CABIN FLOORBEAM Y765 AT FRAME 66+3 INCHES. MX REMOVED AND REPLACED FLOORBEAM Y765 FROM FRAME 64 TO FRAME 66+6 IAW THE REQUIREMENTS OF A319 SRM 51-72-11, PAGE 1 AND 2. UPON COMPLETION OF THE REPAIRSDR F3LA200800636Floorbeam · corrodedDURING C4/S1 C-CHECK, INSPECTION NOTED CORROSION ON PASSENGER CABIN FLOORBEAM Y1292 AT FRAME 66. MX REMOVED AND REPLACED FLOORBEAM Y1292 AT FRAME 64 TO FRAME 66 IAW THE REQUIREMENTS OF A319 SRM 51-72-11. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOSDR F3LA200800631Sill · corrodedDURING C4/S1 C-CHECK, INSPECTION NOTED CORROSION ON PASSENGER CABIN LOWER SILL LOCATED AT LT FRAME 67+17 INCHES AND FRAME 68. MX PERFORMED STRUCTURAL REPAIR IAW THE REQUIREMENTS OF A319 SRM 53-41-14, FIGURE 201. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTESDR F3LA200800630Floorbeam · corrodedDURING C4/S1 C-CHECK, INSPECTION NOTED CORROSION ON PASSENGER CABIN FLOORBEAM Y1292 AT FRAME 68 TO FRAME 69. MX REMOVED AND REPLACED FLOORBEAM AT FRAME 68 TO FRAME 69 IAW THE REQUIREMENTS OF A319 SRM 51-72-11. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED SDR F3LA200800653Skin · burnedREFERENCE NON ROUTINE 2008-196727. DURING C4/S1 C-CHECK, INSPECTION NOTED LIGHTNING STRIKE DAMAGE ON EXTERNAL SKIN LOCATED AT FRAME 1 + 8 INCHES, RT HAND SIDE UPPER FUSELAGE AT VERTICAL REFERENCE AXIS Z O. MX PERFORMED PERMANENT REPAIR IN ACCORDANCE WITH THESDR F3LA200800647Floor Panel · perforatedDURING C4/S1 C-CHECK, INSPECTION NOTED FLOOR PANEL 131DG WAS PERFORATED. MX REPAIRED THE FLOOR PANEL IAW THE REQUIREMENTS OF A319 SRM 53-02-00 PARA 8C. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800646Floor Panel · perforatedDURING C4/S1 C-CHECK, INSPECTION NOTED FLOOR PANEL 132DG WAS PERFORATED. MX REPAIRED THE FLOOR PANEL IAW THE REQUIREMENTS OF A319 SRM 53-02-00 PARA 8C. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800645Floor Panel · perforatedDURING C4/S1 C-CHECK, INSPECTION NOTED FLOOR PANEL 132EG WAS PERFORATED. MX REPAIRED THE FLOOR PANEL IAW THE REQUIREMENTS OF A319 SRM 53-02-00, PARA 8C. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800644Floor Panel · perforatedDURING C4/S1 C-CHECK, INSPECTION NOTED FLOOR PANEL 131EG WAS PERFORATED. MX REPAIRED THE FLOOR PANEL IAW THE REQUIREMENTS OF A319 SRM 53-02-00,PARA 8C. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800643Floor Panel · perforatedDURING C4/S1 C-CHECK, INSPECTION NOTED FLOOR PANEL 151AE WAS PERFORATED. MX REPAIRED THE FLOOR PANEL IAW THE REQUIREMENTS OF A319 SRM 53-02-00, PARA 8C. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800639Floor Panel · damagedDURING C4/S1 C-CHECK, INSPECTION NOTED PERFORATION ON FLOOR PANEL 151VG IN THE AFT CARGO COMPARTMENT. MX REPAIRED THE FLOOR PANEL IAW THE REQUIREMENTS OF A319 SRM 53-02-00, PARA 8C. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE.SDR F3LA200800611Floor Panel · damagedREFERENCE NON ROUTINE CO51333. DURING C3 C CHECK, INSPECTION NOTED FLOOR PANEL 261EF HAD DAMAGED AREA AROUND INSERT ON OTBD EDGE. MX REMOVED FLOOR PANEL AND REPLACED WITH NEW IN ACCORDANCE WITH THE REQUIREMENTS OF A319 AMM 53-42-12-400-002. UPON COMPLETION SDR F3LA200800612Scuff Plate · corrodedREFERENCE NON ROUTINE C051324. DURING C3 C CHECK, INSPECTION NOTED THE L2 DOOR AFT OTBD SCUFF PLATE SUPPORT ATTACHMENT HAD A CORRODED FASTENER. MX REMOVED CORNER ANGLE, OVERSIZED 3 HOLES, FABRICATED 3 FREEZE PLUGS, INSTALLED CORNER ANGLE AND NEW SCUFF PLATE SDR F3LA200800615Sill · corrodedREFERENCE NON ROUTINE CO51321. DURING C3 C CHECK INSPECTION NOTED THE L2 DOOR SILL AFT OTBD NUT PLATE HOLE WAS CORRODED. MX CUT CORRODED AREA OUT OF THE SILL WEB, FABRICATED REPAIR FILLER AND INSTALLED REPAIR IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 5SDR F3LA200800614Floorbeam · corrodedDURING C3 C-CHECK INSPECTION NOTED FLOORBEAMS INBOARD OF THE L2 DOOR SILL CORRODED AND CORROSION IN ALL NUT PLATE HOLES. MX REMOVED FLOORBEAMS, REMOVED BARREL NUT FITTING AND SPLICE, DRILLED HOLES IN SERVICEABLE BEAM, INSTALLED BARREL NUT FITTING AND SPLICE ASDR F3LA200800616Pin · failedFLIGHT NR 3183. NR 1 ELECTRONIC CENTRALIZED ACFT MONITOR INDICATED LANDING GEAR CONTROL INTERFACE UNIT FAULT. ACFT VIBRATION WAS FELT AFTER LANDING AND ACFT STOPPED ON RUNWAY. MX FOUND NOSE GEAR TIRES TURNED 90 DEGREES AND SEVERAL BROKEN NLG PARTS ON THE RUSDR F3LA200800613Sill · corrodedDURING C3 C-CHECK, INSPECTION NOTED THE L2 FORWARD GIRT BAR ATTACH FITTING, AFT INBOARD HOLE HAD CORROSION. MX CUT CORRODED AREA OUT OF THE SILL WEB, FABRICATED REPAIR FILLER AND INSTALLED REPAIR IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-41-14, 51-75SDR F3LA200800609Floorbeam · corrodedDURING C3 C-CHECK, INSPECTION NOTED THE FLOORBEAM IB OF THE R2 DOOR SILL HAS CORROSION IN ALL NUT PLATE HOLES. MAINT REMOVED AND REPLACED FLOORBEAM. Y1292 IAW THE REQUIREMENTS OF A319 SRM 51-42-11. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ASDR F3LA200800610Shear Plate · corrodedREFERENCE NOT ROUTINE C051378. DURING C3 C-CHECK, INSP NOTED THE RT SHEAR PLATE FROM FR 69 TO FRAME 70 WAS CORRODED. MAINT REMOVED AND REPLACED SHEAR PLATE ASSY AND SUPPORT FRAME IAW THE REQUIREMENTS OF A319, SRM 51-42-11, PARA 6 AND 7. UPON COMPLETION OF THSDR F3LA200800606Panel · puncturedREFERENCE NON-ROUTINE C050859. DURING C3 C-CHECK. INSPECTION NOTED THE AFT PIT TRANSITION PANEL 151FE WAS DAMAGED. MAINTENANCE REPAIRED DAMAGED FLOOR PANEL IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR. IT WAS INSPECTEDSDR F3LA200800607Panel · puncturedREFERENCE NON-ROUTINE C050860. DURING C3-C-CHECK, INSPECTION NOTED THE AFT PIT TRANSITION PANEL 151BE WAS DAMAGED. MAINTENANCE REPAIRED DAMAGED FLOOR PANEL IAW THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED ASDR F3LA200800608Panel · puncturedREF NON-ROUTINE C050863. DURING C3-C-CHECK. INSP NOTED THE AFT PIT TRANSITION PANEL 151TG WAS DAMAGED. MAINT REPAIRED DAMAGED FLOOR PANEL IAW WITH THE REQUIREMENTS OF SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR. IT WAS INSPECTED AND FOUND ACCEPTABSDR F3LA200800618Floor Panel · corrodedREFERENCE NON ROUTINE CO51286. DURING C3 C CHECK, INSPECTION NOTED FLOOR PANEL 262FF HAD CORROSION ON AFT BOTTOM SURFACE. MX REMOVED FLOOR PANEL AND INSTALLED NEW IN ACCORDANCE WITH THE REQUIREMENTS OF A319 AMM 53-42-12-400-002. UPON COMPLETION OF THE REPAISDR F3LA200800617Floor Panel · corrodedREFERENCE NON ROUTINE CO51223. DURING C3 C CHECK INSPECTION NOTED FLOOR PANEL 261FF HAD CORROSION ON UPPER AND LOWER SURFACES. MX REMOVED FLOOR PANEL AND INSTALLED NEW IN ACCORDANCE WITH THE REQUIREMENTS OF A319 AMM 53-42-12-400-002. UPON COMPLETION OF THE SDR F3LA200800604Floor Panel · corrodedREF: NON ROUTINE C050752. DURING C3 C-CHECK, INSPECTION FOUND (1) MOUNT BUSHING CORRODED ON FLOOR PANEL 261DE. MAINTENANCE REMOVED AND REPLACED MOUNT BUSHING ON C-CHECK CARD NR C5341032. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND ACCEPTABLE. (KSDR F3LA200800605Skin · dentedREF NON ROUTINE C00003. DURING EXIT CHECK, INSPECTION NOTED THE AC INCURRED A BIRD STRIKE CAUSING A DENT IN THE FUSELAGE SKIN BELOW THE RT COCKPIT WINDSHIELD. THE DENT MEASURED 2 INCHES WIDE AND 2 INCHES LONG BY .1250 INCH DEEP. MAINT PERFORMED A DETAILED VISUSDR F3LA200800601Floorbeam · corrodedDURING C3 C-CHECK, INSPECTION NOTED SEVERAL NUT PLATE HOLES ON FRAME Y-1292 BETWEEN FRAME 66 AND FRAME 68 HAS CORROSION. MAINTENANCE REMOVED AND REPLACED FLOORBEAM IN ACCORDANCE WITH A319 SRM 51-42-11.SDR F3LA200800600Floorbeam · corrodedREF NON ROUTINE C050600. DURING C3 C-CHECK, INSPECTION NOTED FWD NUT PLATE HOLE ON FRAME Y-1292 AT FRAME 66, HAD CORROSION. MAINT REMOVED CORROSION FROM HOLE, FABRICATED REPAIR BUSHING AND INSTALLED IAW WITH THE REQUIREMENTS OF ENGINEERING AUTHORIZATION NR A9SDR F3L2008F00005Floor Support · corrodedREF: NON ROUTINE C050602. DURING C3 C-CHECK, INSPECTION NOTED SEVERAL NUT PLATE HOLES ON FRAME Y-1292 BETWEEN FRAME 66 AND FRAME 68, HAD CORROSION. MAINTENANCE REMOVED AND REPLACED FLOORBEAM IAW WITH THE REQUIREMENTS OF A319 SRM 51-42-11. UPON COMPLETION OF THSDR F3LA200800599Floorbeam · corrodedREF NON ROUTINE C050605. DURING C3 C-CHECK, INSPECTION NOTED SEVERAL NUT PLATE HOLES ON FRAME Y-1292 BETWEEN FRAME 66 AND FRAME 68, HAD CORROSION. MAINT REMOVED CORROSION FROM HOLES, FABRICATED REPAIR PROFILE AND FILLER, AND INSTALLED IAW THE REQUIREMENTS OFSDR FELA200800597Floor Panel · corrodedREFERENCE NON ROUTINE C050515. DURING C3 C-CHECK INSPECTION NOTED FLOOR PANEL 261FF HAS CORROSION ON LOWER SURFACE. MX R&R FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 AMM 53-42-12 PB 401. UPON COMPLETION OF THE REPAIR, IT WAS INSPECTED AND FOUND
Back to Airbus A319-111