Airbus A319-111
Service difficulty reports · 2,475
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319111' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319111' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR F3LA200800457Floor Panel · damagedDURING C-CHECK INSP NOTED AFT PIT PANEL 151FE DAMAGED. MAINT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800456Panel · damagedDURING C-CHECK INSP NOTED AFT PIT PANEL 151DE DAMAGED. MAINT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800455Floor Panel · damagedDURING C-CHECK INSP NOTED AFT PIT PANEL 151PE DAMAGED. MAINT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800454Panel · damagedDURING C-CHECK INSP, NOTED AFT PIT PANEL 161NF DAMAGED. MAINT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800453Floor Panel · damagedDURING C-CHECK INSP AFT PIT PANEL 161BF DAMAGED. MIANT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800452Floor Panel · damagedDURING C-CHECK INSP, NOTED AFT PIT PANEL 162EF DAMAGED. MAINT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800451Floor Panel · damagedDURING C-CHECK INSP, NOTED AFT PIT PANEL 161CF DAMAGED. MAINT REMOVED DAMAGE AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800464Floor Panel · damagedDURING C-CHECK INSP NOTED FWD PIT PANEL 131EG DAMAGED. MAINT REPAIRED DAMAGE IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800481Floor Panel · damagedDURING C-CHECK INSP, NOTED FLOOR PANEL 261PF HAD COMPOSITE DAMAGE. MAINT REMOVED AND REPLACED FLOOR PANEL 261PF WITH NEW PANEL, REFERENCED ON EAC NON ROUTINE ITEM 9651. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800487Skin · chafedDURING C-CHECK INSP NOTED THE RT AILERON APPEARS TO BE CHAFING AT IB LOWER EDGE. MAINT CLEANED AREA OF DAMAGE AND REPAIRED IAW SRM 51-75-12. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800471Profile · corrodedDURING C-CHECK INSP NOTED CORROSION SEVERAL PLACES ON PROFILE LT SIDE AFT OF FRAME C28 FWD CARGO COMPARTMENT. MAINT REMOVED OLD PROFILE AT FRAME C28 ON LT SIDE, LOCATED AND DRILLED HOLES ON NEW PROFILE AND INSTALLED NEW PROFILE IAW SRM 51-72-11 AND SRM 51-42-1SDR F3LA200800472Floor Support · corrodedDURING C-CHECK INSP NOTED RT LONGERON BEAM AT Y-1292 FROM FRAME 66 TO FRAME 68 HAD AREAS OF CORROSION. MAINT REMOVED AND REPLACED FLOOR SUPPORT LONGERON Y-1292 FROM FRAME 66 TO FRAME 69 IAW SRM 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUNDSDR F3LA200800473Longeron · corrodedDURING C-CHECK INSP NOTED RT LONGERON BEAM AT Y-1162 FROM FRAME 68 TO FRAME 69 HAD AREAS OF CORROSION. MAINT REMOVED AND REPLACED FLOORBEAM LONGERON Y-1162 FROM FRAME 68 TO FRAME 69 IAW SRM 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCSDR F3LA200800474Cargo Track · corrodedDURING C-CHECK INSP NOTED CORROSION ON PLATE BELOW TIE-DOWN PLATE UNDER FRAME C25 FWD CARGO PIT. MAINT REMOVED PLATE AND BLENDED CORROSION, MORE THAN 50 PERCENT MATERIAL LOSS AND FOUND TO BE OUT OF LIMITS IAW SRM 53-21-14 OUT TO LIMITS OR ACTIONS NOT STATED. SDR F3LA200800475Girt Bar · stickingDURING C-CHECK INSP NOTED R1 GIRT BAR FITTING FOR DOOR SLIDE STOP LEVER STICKS, DOES NOT SNAP BACK WHEN PRESSED DOWN AND RELEASED. MAINT REMOVED AND REPLACED WITH NEW GIRT BAR FITTING IAW AMM 52-11-31-000-003 AND 52-11-31-400-003. UPON COMPLETION OF THE REPAIRSDR F3LA200800476Profile · corrodedDURING C-CHECK INSP NOTED CORROSION ON PROFILE PARALLEL WITH FRAME C28 FWD CARGO COMPARTMENT. MAINT REMOVED AND REPLACED CORRODED PROFILE ON FRAME C28 IN FWD CARGO COMPARTMENT IAW FO A319 SRM 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ASDR F3LA200800477Fitting · corrodedDURING C-CHECK INSP NOTED CORROSION ON PLATE BELOW TIE-DOWN PLATE AT FRAME C29 FWD CARGO COMPARTMENT. MAINT REMOVED AND REPLACED FITTING, REINSTALLED PLATE AND TIE-DOWN AT FWD CARGO COMPARTMENT FRAME C29 IAW SRM 51-42-11 AND 51-72-11. UPON COMPLETION OF THE RESDR F3LA200800478Profile · corrodedDURING C-CHECK INSP, NOTED CORROSION ON AFT CARGO COMPARTMENT LT PROFILE, FWD AREA OF AFT CARGO, AT FRAME C47 TO FRAME C51. MAINT REMOVED AND REPLACED PROFILE AT FRAME C47 TO FRAME C51 IAW SRM 51-72-11, 51-21-11 AND 51-42-11. UPON COMPLETION FO THE REPAIR IT WSDR F3LA200800479Profile · corrodedDURING C-CHECK INSP NOTED CORROSION ON THE AFT CARGO COMPARTMENT PROFILE AT FRAME C56. MAINT REMOVED AND REPLACED PROFILE IN AFT CARGO COMPARTMENT AT FRAME C56 IAW A319 SRM 51-72-11 AND 51-42-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTASDR F3LA200800480Seat Track · corrodedDURING C-CHECK INSP NOTED THE RT LONGERON BEAM Y-765 AT FRAME 66 HAD CORROSION AROUND THE HOLE. MAINT REMOVED AND REPLACED CORRODED LONGERON BEAM AT Y-765 FRAME 64 TO FRAME 66 IAW SRM 51-42-11 AND 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOSDR F3LA200800448Floor Support · wornDURING C-CHECK INSP NOTED BEAM NR FOUR AT AFT WALL MOUNT HAS EXCESSIVE PLAY AT MOUNT AT FLOOR TRACK IN THE FWD CARGO COMPARTMENT. MAINT REMOVED AND REPLACED BEAM NR FOUR AFT WALL MOUNT FITTING IN THE FWD CARGO COMPARTMENT IAW SRM 51-72-11 PAGE 1 AND 2. UPON COSDR F3LA200800447Cargo Track · wornDURING C-CHECK INSP, NOTED BEAM NR 11 HAS EXCESSIVE PLAY AFT WALL OF FWD CARGO PIT AT FLOOR TRACK. MAINT REMOVED AND REPLACED BEAM NR 11 AFT WALL MOUNT FITTING IN FWD CARGO BAY IAW SRM 51-72-11 PAGE 1 AND 2. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FSDR F3LA200800446Fitting · wornDURING C-CHECK INSP NOTED BEAM NR TWO AT AFT WALL OF FWD CARGO COMPARTMENT MOUNT AND WALL BEAM HAS EXCESSIVE PLAY. MAINT REMOVED AND REPLACED BEAM NR 11 AFT WALL MOUNT FITTING IN THE FWD CARGO BAY IAW SRM 51-72-11 PAGE 1 AND 2. UPON COMPLETION OF THE REPAIR ITSDR F3LA200800442Longeron · corrodedDURING C-CHECK INSP NOTED THE LT LONGERON BEAM AT Y765 AND FRAME 68 HAS AREAS OF CORROSION. MAINT REMOVED AND REPLACED THE LT LONGERON BEAM AT Y765 AND FRAME 68 IAW SRM 51-42-11 PAGE 1 AND 2.UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. SDR F3LA200800445Fitting · wornDURING C-CHECK INSP NOTED THE FWD CARGO COMPARTMENT AFT WALL BRACE MOUNT AT UPPER FLOOR TRACKS HAS EXCESSIVE PLAY ON BEAM NR 1. MAINT REMOVED AND REPLACED BEAM NR 1 AFT WALL MOUNT FITTING IN THE FWD CARGO BAY IAW SRM 51-72-11 PAGE 1 AND 2. UPON COMPLETION OF TSDR F3LA200800444Skin · damagedDURING C-CHECK INSP NOTED LIGHTNING STRIKE ON FASTNER AT FRAME 29 STATION 1270 STRINGER 41. MAINT REPAIRED BY REMOVING BLIND FASTNER AND COLD WORKING HOLE AND INSTALLING LOCK FASTENER IAW SRM 51-42-11, SRM 51-48-00 AND SRM 53-21-11. UPON COMPLETION OF THE REPASDR F3LA200800443Longeron · corrodedDURING C-CHECK INSP, NOTED THE LT LONGERON BEAM AT Y1162 AND FRAME 68 HAS AREAS OF CORROSION. MAINT REMOVED AND REPLACED THE LT LONGERON BEAM AT Y1162 AND FRAME 68 IAW SRM 51-72-11 AND SRM 51-42-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCESDR F3LA200800439Skin · damagedDURING C-CHECK INSP, NOTED LIGHTNING STRIKE BURN MARK BELOW FWD CARGO DOOR STATION 927 AT STRINGER 38. MAINT REPAIRED BY REMOVING BLIND FASTENER COLD WORKING HOLE AND INSTALLING LOCK FASTENER IAW SRM 51-42-11, SRM 51-48-00 AND SRM 53-21-11. UPON COMPLETION OF SDR F3LA200800438Skin · damagedDURING C-CHECK INSP NOTED LIGHTNING STRIKE ON FASTNER AT FRAME 26 STATION 1057 STRINGER 40. MAINT REPAIRED BY MOVING BLING FASTNER AND COLD WORKING HOLE AND INSTALLING HI-LOCK IAW SRM 51-42-11, SRM 51-48-00 AND SRM 53-21-11 FIGURE 201. UPON COMPLETION OF THE RSDR F3LA200800437Skin · damagedDURING C-CHECK INSP NOTED LIGHTNING STRIKE BURN MARK BELOW FWD CARGO DOOR STATION 979 AT STRINGER 38. MAINT REMOVED AND REPLACED BLIND FASTNER WITH HI-LOCK AFTER COLD WORKING HOLE AT STATION 979 STRINGER 38 IAW SRM 53-21-11 FIGURE 210. UPON COMPLETION OF THE RSDR F3LA200800436Skin · damagedREFERENCE NON ROUTINE 29004. DURING C-CHECK INSP NOTED LIGHTNING STRIKE FOUND AT FRAME 25 STATION 1003 STRINGER 41R. MAINT REPAIRED BY REMOVING BLIND FASTNER AND INSTALLED HI-LOCK IAW SRM 51-42-11, SRM 51-48-00, AND SRM 53-21-11. UPON COMPLETION OF THE REPAIR SDR F3LA200800435Shear Plate · corrodedDURING C-CHECK INSP NOTED LT LATERAL SHEAR PLATE AT Y1162 FROM FRAME 69 TO FRAME 70 HAS CORROSION AND FOUR SHEARED FASTNERS AT FWD END. MAINT REMOVED AND REPLACED LT LATERAL SHEAR PLATE AT Y1162 FRAME 69 TO FRAME 70 IAW SRM 51-72-11. UPON COMPLETION OF THE REPSDR F3LA200800434Floorboard · puncturedDURING C-CHECK INSP NOTED AFT CARGO COMPARTMENT FLOORBOARD 151BE HAS A PUNCTURE IN IT. MAINT CLEANED, PREPPED AND REPAIRED FLOORBOARD 151BE IAW SRM 53-02-00 PARAGRAPH 8C FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800433Floorboard · puncturedDURING C-CHECK INSP NOTED AFT CARGO COMPARTMENT FLOORBOARD 151TG HAS A PUNCTURE IN IT. MAINT CLEANED, PREPPED AND REPAIRED FLOORBOARD 151TG IAW SRM 53-02-00 PARAGRAPH 8C FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800432Floorboard · puncturedDURING C-CHECK INSP NOTED AFT CARGO COMPARTMENT FLOORBOARD 151DE HAS A PUNCTURE IN IT. MAINT CLEANED, PREPPED AND REPAIRED FLOORBOARD 151DE IAW SRM 53-02-00 PARAGRAPH 8C FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800431Floor Panel · puncturedDURING C-CHECK INSP NOTED AFT CARGO COMPARTMENT FLOORBOARD 152TG HAS A PUNCTURE IN PANEL. MAINT CLEANED, PREPPED AND REPAIRED FLOORBOARD 152TG IAW SRM 53-02-00 PARAGRAPH 8C FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800430Floorboard · puncturedREFERENCE NON ROUTINE 36564. DURING C-CHECK INSP NOTED AFT CARGO COMPARTMENT FLOORBOARD 151AE IS PUNCTURED. MAINT CLEANED PREPPED AND REPAIRED FLOORBOARD 151AE IAW OF SRM 53-02-00 PARAGRAPH 8C FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUNSDR F3LA200800429Floorboard · puncturedDURING C-CHECK INSP NOTED CABIN FLOORBOARD 242FF IS PUNCTURED IN THE CENTER OF THE PANEL. MAINT PREPPED FLOORBOARD 242FF FOR REPAIR AND REPAIRED IAW SRM 53-12-00 PARAGRAPH 5B FIGURE 202. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800428Floorboard · crackedDURING C-CHECK INSP NOTED FLOORBOARD 251HF HAS A CRACK IN THE TOP OF THE BOARD. MAINT PREPPED AREA OF DAMAGE ON FLOORBOARD 251HF FOR REPAIR AND REPAIRED IAW ARM 53-12-00 PARAGRAPH 5B FIGURE 202. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABSDR F3LA200800418Bottle · lowDURING C-CHECK INSP, NOTED L2 DOOR ASSIST BOTTLE PRESSURE IS LOW. MAINT SERVICED L2 DOOR ASSIST BOTTLE IAW AMM 52-10-00-614-001. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800417Floor Support · corrodedDURING C-CHECK INSP NOTED AFT CARGO COMPARTMENT CENTER FLOORBEAM BETWEEN FRAME C60 AND FRAME C61 HAS CORROSION. MAINT REMOVED AND REPLACED FLOORBEAM BETWEEN FRAME C60 AND FRAME C61 IAW REQUIREMENTS OF SRM 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTESDR F3LA200800416Floorboard · delaminatedDURING C-CHECK INSP NOTED FLOORBOARD 241FF HAS DELAMINATION ALONG THE EDGE OF THE FLOORBOARD. MAINT PREPPED AREA OF DAMAGE ON FLOORBOARD 241FF FOR REPAIR AND REPAIRED IAW SRM 53-02-00 PARAGRAPH 8J FIGURE 212. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND SDR F3LA200800412Shear Plate · corrodedDURING C-CHECK INSP, NOTED LT INTERCOSTGAL WEB UNDER LATERAL SHEAR PLATE AT STRINGER 23 LT FROM FRAME 69 TO FRAME 70 HAS CORROSION ON TOP AND BOTTOM SIDES. MAINT REMOVED CORRODED WEB, DRILLED, TREATED AND PRIMED HOLES AND INSTALLED NEW WEB IAW SRM 51-72-11. UPSDR F3LA200800411Fitting · wornDURING C-CHECK INSP NOTED FWD BATTERY TRAY OB AFT MOUNT HAS WEAR. MAINT REMOVED AND REPLACED FWD BATTERY TRAY OB AFT MOUNT IAW SRM 51-42-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800413Intercostal · corrodedDURING C-CHECK INSP NOTED RT INTERCOSTAL WEB UNDER LATERAL SHEAR PANEL AT STRINGER 23 RT FROM FRAME 69 TO FRAME 70 HAS CORROSION ON BOTTOM SIDE. MAINT REMOVED CORRODED INTERCOSTAL, LOCATED AND DRILLED NEW INTERCOSTAL, TREATED AND PRIMED HOLES AND INSTALLED NEWSDR F3LA200800409Unknown · odorDURING FLIGHT, FLIGHT CREW NOTED AN ODOR OF GAS IN AFT GALLEY. MAINT INSPECTED AC FOR UNSATISFACTORY CABIN AIR QUALITY IAW TSM 21-00-00-810-802. NO ODOR OR SOURCE OF ODOR WAS NOTED. FIRE DEPARTMENT AND HAZMAT CREW INSPECTED THE CABIN AND CARGO COMPARTMENT, SDR F3LA200800405Floorboard · damagedDURING C-CHECK INSP NOTED AFT CARGO PIT FWD FLOORBOARD PANEL 151PE HAS A HOLE AT THE AFT LT EDGE. MAINT REMOVED DAMAGED AREA AND FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800406Panel · damagedDURING C-CHECK INSP, NOTED AFT CARGO PIT AFT LT HAND TRANSITION PANEL 161BF HAS A HOLE AT AFT TOP END. MAINT REPAIRED AND INSTALLED SERVICEABLE PANEL 161BF IAW SRM 53-42-44-400-001. COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800407Panel · damagedDURING C-CHECK INSP NOTED AFT CARGO PIT FWD LT HAND LOWER TRANSITION PANEL 151AE HAS A HOLE AT FWD LOWER END. MAINT REPAIRED AND INSTALLED SERVICEABLE PANEL 151AE IAW SRM 53-42-14-400-001. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. SDR F3LA200800393Control Unit · malfunctionedAFTER TAKEOFF THE FLIGHT CREW NOTICED THE NLG FAILED TO RETRACT. THE FLIGHT CREW FOLLOWED THE ECAM AND CYCLED GEAR AND NOSE GEAR RETRACTED NORMALLY AND THE AC RETURNED TO DEPARTURE. MAINT PERFORMED GEAR SWING SUCCESSFULLY 8 TIMES AND REMOVED AND REPLACED NR 2
Back to Airbus A319-111