SDR F3LA200800530Floorbeam · corrodedDURING C3 C-CHECK, INSP NOTED 5 NUT CLIP HOLES CORRODED ON FLOORBEAM Y1292 (L-2) BETWEEN FRAME 66 AND FRAME 68. MAINT REMOVED ALL FASTENERS FROM THE FLOORBEAM, REMOVED DAMAGED FLOORBEAM, AND INSTALLED NEW FLOORBEAM AND FASTENERS IAW SRM 51-42-11. UPON COMPLETSDR F3LA200800529Floorbeam · corrodedDURING C3 C-CHECK, INSPECTION NOTED CORROSION AROUND THE NUT PLATE HOLE ON FLOORBEAM Y1292 AT FRAME 67, AND TOOLING MARK BETWEEN FRAME 67 AND 68 APPROXIMATELY 8 INCHES LONG. MAINTENANCE REMOVED AND REPLACED FLOORBEAM Y1292 BETWEEN FRAME 67 AND FRAME 68, IAW TSDR F3LA200800542Profile · corrodedDURING C3 C-CHECK, INSPECTION NOTED THE TRANSITION PROFILE, LT SIDE BETWEEN FRAMES 28 AND 29 HAD CORROSION AT THE NUT PLATE LOCATIONS. MAINTENANCE REMOVED AND REPLACED TRANSITION PROFILE IAW THE REQUIREMENTS OF A319 SRM 51-72-11. UPON COMPLETION OF THE REPAISDR F3LA200800528Floor Panel · damagedDURING C3 C-CHECK, INSPECTION NOTED FLOOR PANEL 242FF WAS DAMAGED IN SEVERAL PLACES. MAINTENANCE REPAIRED FLOOR PANEL IN ACCORDANCE WITH A319 SRM 53-02-00, PARAGRAPH 3, SOLUTION B, PAGE 245.SDR F3LA200800541Blanking Plate · corrodedDURING C-CHECK, INSP NOTED THE L2 AFT GIRT BAR BLANKING PLATE HAD CORROSION. MAINT REMOVED AND REPLACED CORRODED L2 DOOR AFT GIRT BAR FITTING BLANKING PLATE IAW AMM 52-13-31-400-007. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)SDR F3LA200800540Plate · corrodedDURING C3 C-CHECK, INSPECTION NOTED THE L2 FORWARD GIRT BAR BLANKING PLATE HAD CORROSION. MAINTENANCE REMOVED AND REPLACED CORRODED L2 DOOR FORWARD GIRT BAR FITTING BLANKING PLATE IAW THE REQUIREMENTS OF AMM 52-13-31-400-007. UPON COMPLETION OF THE REPAIR ITSDR F3LA200800539Blanking Plate · corrodedDURING C-CHECK, INSP NOTED THE R2 AFT GIRT BAR BLANKING PLATE HAD CORROSION. MAINT REMOVED AND REPLACED CORRODED R2 DOOR AFT GIRT BAR FITTING BLANKING PLATE IAW AMM 52-13-31-400-007. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)SDR F3LA200800538Blanking Plate · corrodedDURING C-CHECK, INSP NOTED THE R2 FWD GIRT BAR BLANKING PLATE HAD CORROSION. MAINT REMOVED AND REPLACED CORRODED R2 DOOR FWD GIRT BAR FITTING BLANKING PLATE IAW AMM 52-13-31-400-007. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)SDR F3LA200800526Floor Panel · damagedDURING C-CHECK, INSP NOTED THE FLOOR PANEL 251FF NEEDED TOP LAYER OF COMPOSITE REPAIRED IN SEVERAL PLACES. MAINT REPAIRED FLOOR PANEL 251FF IAW SRM 53-02-00 FIGURE 212. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800527Floor Panel · damagedDURING C-CHECK, INSP, NOTED THE FLOOR PANEL 251LF NEEDED TOP LAYER OF COMPOSITE REPAIRED IN SEVERAL PLACES. MAINT REPAIRED FLOOR PANEL 251LF IAW SRM 53-02-00 PARAGRAPH 8.A FIGURE 201. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800520Switch · faultyDURING PRE-FLIGHT INSP, CREW NOTED THE EMERGENCY EXIT AND AISLE LIGHTS WERE ILLUMINATED IN THE ARMED POSITION. MAINT REMOVED AND REPLACED THE TOGGLE SWITCH AND PERFORMED AN OPS CHECK IAW AMM 33-51-00. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND SDR F3LA200800524Sensor · faultyFLIGHT CREW NOTED THE R2 DOOR INDICATION IS INOPERATIVE. WHILE CLOSED AND ARMED, THE ELECTRONIC CENTRALIZED AC MONITORING INDICATION IS AN AMBER BLOCK AND "SLIDE ARMED" INDICATION IS NOT ILLUMINATED. THIS DEFECT HAS BEEN DEFERRED (1063174) AND IS DUE ON 8/05SDR F3LA200800508Bushing · unsecureFLIGHT CREW NOTED THE R1 DOOR WOULD NOT LATCH IN THE OPEN POSITION. MAINTENANCE RESECURED THE GUST LOCK BUSHING IN ACCORDANCE WITH AMM 52-11-00 PB 501.SDR F3LA200800518Floor Panel · gougedDURING C-CHECK, INSP NOTED THE AFT CARGO PIT AFT RT LOWER TRANSITION PANEL 162BF WAS GOUGED AND A PREVIOUS REPAIR WAS PEELING UP. MAINT REPAIRED TRANSITION PANEL 162BF IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPSDR F3LA200800509Floor Panel · peelingDURING C-CHECK, INSP NOTED THE PREVIOUS REPAIRS PEELING LOOSE ON THE AFT CARGO PIT FWD LT UPPER TRANSITION PANEL 151UG. MAINT REPAIRED TRANSITION PANEL 151UG IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (ASDR F3LA200800510Floor Panel · puncturedDURING C2 C-CHECK, INSP NOTED THE AFT CARGO PIT FWD RT LOWER TRANSITION PANEL 152WG WAS PUNCTURED. MAINT REPAIRED TRANSITION PANEL 152WG IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800511Floor Panel · puncturedDURING C2 C-CHECK, INSP NOTED THE AFT CARGO PIT FWD LT UPPER TRANSITION PANEL 151BE WAS PUNCTURED. MAINT REPAIRED TRANSITION PANEL 151BE IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800512Floor Panel · gougedDURING C-CHECK, INSP NOTED THE AFT CARGO PIT FORWARD LT LOWER TRANSITION PANEL 151AE WAS GOUGED IN THE CENTER OF THE PANEL. MAINT REPAIRED TRANSITION PANEL 151AE IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLESDR F3LA200800513Floor Panel · puncturedDURING C-CHECK, INSP NOTED THE AFT CARGO PIT CENTER LT UPPER TRANSITION PANEL 151FE WAS PUNCTURED. MAINT REPAIRED TRANSITION PANEL 151FE IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800514Floor Panel · puncturedDURING C-CHECK, INSP NOTED THE AFT CARGO PIT CENTER LT LOWER TRANSITION PANEL 151DE WAS PUNCTURED. MAINT REPAIRED TRANSITION PANEL 151DE IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800515Floor Panel · puncturedDURING C-CHECK, INSP NOTED THE AFT CARGO PIT FLOOR PANEL 161NF WAS PUNCTURED SEVERAL TIMES. MAINT REPAIRED FLOOR PANEL 161NF IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE.(A)SDR F3LA200800516Floor Panel · puncturedDURING C-CHECK, INSP NOTED THE AFT CARGO PIT AFT LT UPPER TRANSITION PANEL 161CF WAS PUNCTURED IN THE CENTER, COVERED WITH TAPE. MAINT REPAIRED TRANSITION PANEL 161CF IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPSDR F3LA200800517Floor Panel · puncturedDURING C-CHECK, INSP NOTED THE AFT CARGO PIT AFT LT LOWER TRANSITION PANEL 161BF WAS PUNCTURED. MAINT REPAIRED TRANSITION PANEL 161BF IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3L2008F00001Bushing · unsecureFLIGHT CREW NOTED THE R1 DOOR WOULD NOT LATCH IN THE OPEN POSITION. MAINT RESECURED THE GUST LOCK BUSHING IAW THE AMM 52-11-00-PB501. UPON COMPLETION OF THE REPAIR. IT WAS INSPECTED AND FOUND ACCEPTABLE. (K)SDR F3LA200800505Sign · brokenDURING C-CHECK, INSP NOTED R1 DOOR FWD LOWER EXIT LIGHT IS BROKEN. MAINT REMOVED AND REPLACED R1 DOOR FWD LOWER EXIT LIGHT IAW AMM 33-51-13-400-001. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800500Shear Plate · corrodedDURING C-CHECK, INSP NOTED THE RT LATERAL SHEAR PLATE AT Y-1162, FROM FRAME 69 TO FRAME 70, HAD CORROSION AND FOUR SHEARED FASTENERS AT THE FWD EDGE. MAINT REMOVED AND REPLACED THE LATERAL SHEAR PLATE AT Y-1162 AT FRAME 69 TO FRAME 70 IAW SRM 51-42-11. UPON SDR F3LA200800501Sill · damagedDURING C-CHECK, INSP NOTED THE R2 DOOR SILL PLATE REQUIRED REPLACEMENT DUE TO MISDRILLED HOLE. MAINT REMOVED AND REPLACED R2 DOOR SILL PLATE IAW A319 SRM 51-42-11 AND 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800499Floor Panel · brokenDURING C4 S1 C CHECK, INSPECTION NOTED THE AFT CARGO FLOORBOARD, 151CE, HAD TWO BROKEN CORNERS. MAINTENANCE REMOVED AND REPLACED FLOOR PANEL 151CE. INSTALLATION WAS COMPLETED ON EMPIRE AERO CENTER NON ROUTINE NR 9642. UPON COMPLETION OF THE REPAIR IT WAS INSDR F3LA200800486Profile · corrodedDURING C-CHECK INSP NOTED THE AFT CARGO COMPARTMENT RT SIDE PROFILE HAD CORROSION AT FRAME 59 ON RT SIDE IAW A319 SRM 51-72-11 AND 51-44-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800489Fitting · corrodedDURING C-CHECK INSP NOTED THE R1 DOOR GIRT BAR FITTING IB MOUNT HOLES ON SILL PLATE HAD CORROSION. MAINT BLENDED CORROSION IAW SRM 51-74-00. MAINT REPAIRED AREAS THAT WERE DEEPER THAT .016" WITH A FILLER AND FILLED AREAS THAT WERE LESS THAN .016" WITH ADHESIVESDR F3LA200800490Skin · dentedDURING C-CHECK INSP NOTED THAT THE DAMAGE ON NR 1 ENGINE INLET COWL REQUIRES PERMANENT REPAIR OF DENT AT THE 2 O`CLOCK POSITION. MAINT REPAIRED DAMAGED AREA IAW CMM 54-10-00, REPAIR PROCEDURE NR 23. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCESDR F3LA200800482Battery Box · wornDURING C-CHECK INSP, NOTED AFT BATTERY TRAY OB FWD AND AFT MOUNTS HAVE WEAR. MAINT REMOVED AND REPLACED AFT BATTERY TRAY, OB FWD AND AFT MOUNTS IAW SRM 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800485Profile · corrodedDURING C-CHECK INSP NOTED THE AFT CARGO COMPARTMENT SMALL PROFILE RT SIDE JUST INSIDE DOOR FWD OF FRAME C56 HAS CORROSION. MAINT REMOVED SMALL PROFILE, FABRICATED NEW PROFILE, TREATED, PRIMED AND TOP COATED NEW PROFILE AND INSTALLED IAW SRM 51-21-11, 51-53-11,SDR F3LA200800484Profile · corrodedDURING C-CHECK INSP NOTED THE AFT CARGO COMPARTMENT PROFILE AT FRAME C59 HAD CORROSION AT BOTH ENDS OF THE PROFILE. MAINT REMOVED AND REPLACED THE PROFILE IAW SRM 51-42-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800483Profile · gougedDURING C-CHECK INSP NOTED THE AFT CARGO COMPARTMENT PROFILE AT FRAME C63 IS GOUGED AND HAS A RIVET PULLING THROUGH. MAINT REMOVED AND REPLACED PROFILE AT FRAME C63 IAW SRM 51-72-11, 51-21-11 AND 51-42-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUNSDR F3LA200800488Door Frame · corrodedDURING C-CHECK INSP NOTED CORROSION ON TOP LEG OF FRAME C55A AT FWD EDGE OF C2 DOOR. MAINT REPAIRED DAMAGE ON TOP LEG OF FRAME C55A IAW EA NR A9-53R-30442. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800491Fitting · crackedDURING C-CHECK INSP NOTED THE NR 1 ENGINE PYLON PANEL NR 413CL MOUNTS STRUCTURE WAS CRACKED AT AFT UPPER SCREW HOLE. MAINT REPAIRED NR 1 ENGINE PYLON PANEL NR 413CL MOUNT STRUCTURE AT AFT UPPER HOLE IAW SRM 54-52-12 AND 51-42-11. UPON COMPLETION OF THE REPAIR SDR F3LA200800468`Profile · corrodedDURING C-4/S-1 C-CHECK, INSPECTION NOTED AFT CARGO COMPARTMENT PROFILE AT FRAME C58 HAS CORROSION. MAINTENANCE REMOVED AND REPLACED PROFILE IN ACCORDANCE WITH A319 SRM 51-72-11 AND 51-21-11.SDR F3LA200800467Floorbeam · corrodedDURING C-4/S-1 C-CHECK, INSPECTION NOTED AFT CARGO COMPARTMENT CENTER FLOORBEAM BETWEEN FRAME C58 AND C59 HAS CORROSION. MAINTENANCE REMOVED AND REPLACED CORRODED FLOORBEAM IN ACCORDANCE WITH A319 SRM 51-42-11.SDR F3LA200800466Profile · corrodedDURING C-4/ S-1 C-CHECK, INSPECTION NOTED THE AFT CARGO COMPARTMENT, LEFT SIDE PROFILE AFT OF FRAME C62, HAS CORROSION. MAINTENANCE REMOVED AND REPLACED PROFILE IN ACCORDANCE WITH A319 SRM 51-72-11, 51-21-11 AND 51-44-11.SDR F3LA200800465Frame · corrodedDURING C-CHECK INSP NOTED AFT CARGO COMPARTMENT INSIDE OF C2 DOOR SHORT ANGLE PIECE AT FRAME C59 HAS CORROSION. MAINT REMOVED SHORT ANGLE PIECE APPLIED PROTECTION TREATMENT FABRICATED NEW SHORT ANGLE TREATED, PRIMED AND PAINTED AND INSTALLED IAW SRM 51-72-11, SDR F3LA200800470Profile · corrodedDURING C-CHECK INSP NOTED CORROSION SEVERAL PLACES ON AFT MOST PROFILE AT FWD CARGO COMPARTMENT AFT OF FRAME C30. MAINT REMOVED AND REPLACED PROFILE IAW SRM 51-72-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800469Floorbeam · corrodedDURING C-CHECK INSP NOTED AFT CARGO COMPARTMENT CENTER FLOORBEAM HAS CORROSION BETWEEN FRAME C57 AND FRAME C58. MAINT REMOVED AND REPLACED CORRODED FLOORBEAM AT FRAME C57 AND FRAME C58 IAW SRM 51-41-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND SDR F3LA200800449Deu · inoperativeDURING FLIGHT MANY CABIN LIGHTS WERE COMING ON AND OFF ON AC RT. THE F/A NOTICED A BURNING SMELL OVER ROWS 16,17 AND 18 ON AC RT. MAINT FOUND DEU-A 200RH12 INOPERATIVE AND HAD A SMELL TO IT. MAINT REMOVED AND REPLACED DEU-A 200RH12 IAW AMM 23-73-46 AND OPS CHESDR F3LA200800463Floor Panel · damagedDURING C-CHECK INSP NOTED FWD PIT FLOOR PANEL 131CG DAMAGED. MAINT REPAIRED DAMAGE IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800462Floor Panel · damagedDURING C-CHECK INSP NOTED AFT PIT TRANSITION PANEL 151HE DAMAGED. MAINT REPAIRED DAMAGE IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800461Panel · damagedDURING C-CHECK INSP NOTED AFT PIT TRANSITION PANEL 151GE DAMAGED. MAINT REPAIRED DAMAGE IAW SRM 53-02-00, FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800460Floor Panel · damagedDURING C-CHECK INSP NOTED AFT PIT FLOOR PANEL 151CE DAMAGED. MAINT REPAIRED DAMAGE IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800459Floor Panel · damagedDURING C-CHECK INSP NOTED AFT PIT PANEL 152UG DAMAGED. MAINT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)SDR F3LA200800458Floor Panel · damagedDURING C-CHECK INSP NOTED AFT PIT PANEL 152WG DAMAGED. MAINT REMOVED DAMAGED AREA, FILLED DAMAGED AREA IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (B)
Back to Airbus A319-111