SDR F3LA201911060138Check Valve · failedLP1229537-1 DISCREPENCY: HYD Y RES OVERHEAT IN FLIGHT FOLLOWED ECAM AND QRH AND RETURNED TO MCO.
LP1229537-1 CORRECTIVE ACTION: REF TSM29-13-00-810-802-A. PERFORMED FAULT CONFIRMATION IAW STEP 3B. DETERMINED MORE NOISE THAN USUAL AT CHECK VALVE Y (3083GSDR AALA201911049011Control Panel · out of toleranceAIRCRAFT NOT GROUNDED: CREW DECLARED AN EMERGENCY INTO DCA ON ACCOUNT OF VHF RADIO UNABLE TO TRANSMIT. MAINTENANCE REMOVED AND REPLACED F/O PTT SWITCH IAW AMM 27-92-41. OPS CHECK GOOD. FOUND CONTROL PANEL SWITCH FLOPPING AROUND. REMOVED & REPLACED F/O'S ACP DUSDR ASAA2019103131200Warning System · false activationON CLIMBOUT ECAM SHOWED AIR ENG 1 BLEED FAULT GROUNDED - YES. PERFORMED BITE OF BMC1 REF AMM 36-11-00-740-001-A , TEST OK. NO FAULT CURRENTLY , NO HISTORY 30 DAYS , SEAMC CONTACTEDPER LOGPAGE 8052445: VERIFIED ENG 1 BLEED INOP. EACH MX PROCEDURE CONTAINED IN SDR ASAA2019110191234Slide · unwanted deployL-2 DOOR SLIDE DEPLOYED GROUNDED - YES. REMOVED AND INSTALLED L-2 DOOR SLIDE ASSY. IAW AMM 25-62-44-400-006-A, OPS CHECK OK. NO DEFECTS NOTED AT THIS TIMESDR ASAA2019110121199Light · no indication*APU INOP GPU & AIRSTARD REQD*DURING PREFLIGHT IN PDX FOUND NO RED APU FIRE DISC. GROUNDED - YES. DISC IS STILL INPLACE, BUT DISC IS CLEAR NOT RED. REL IAW MEL 26-22-05-02 (APU INOP/RED DISC).SDR F3LA201910310129Unknown · vibrationLP1222577 -- LOUD VIBRATION IN FLIGHT , FOLLOWED BY VENT EXTRACT FAULT AND INTENSE SMELL OF BURNING FUMES. -- CORRECTIVE ACTION -- DEFERRED PER MEL 21-26-02A CONTROL # 1156277 DUE DATE 11/06/19.SDR ASAA2019102531148Switch · failedHYDRAULIC YELLOW RESERVOIR LOW LEVEL WARNING GROUNDED - YES. R & R LOW LEVEL SWITCH OF THE YELLOW HYD RESERVOIR IAW AMM 29-13-41 PB 401- OPS CHK AND LEAK CHK GOOD A/C OK FOR SERVICESDR F3LA201910240128Unknown · odorODOR EVENT AT CRUISE ALTITUDE STARTED SLIGHT AND GOT VERY STRONG ODOR. DID QRH PROCEDURE FOR ODOR IN FLIGHT, THIS DID NOT CHANGE INTENSITY OF ODOR. CORRECTIVE ACTION: PLACED ON TDI -T 1156114 FOR 60 A.C. DUE AT AC 9424 BY AUTHORITY EA# A0-21T-34386 (ENG #2 ISDR 2019FA0000346Safety Equip · missingAFTER ARRIVAL OF AIRCRAFT AT MAINTENANCE FACILITY, IT WAS FOUND THAT SAFETY RELATED COMPONENTS WERE NOT
INSTALLED IN THE AIRCRAFT AND NO ENTRY WAS MADE IN THE AIRCRAFT TECHNICAL LOGBOOK, NOR WAS IT STATED ON THE SPECIAL FLIGHT PERMITS.
THE MISSING COMPONENTSSDR ASAA2019102183062Thermostat · failedDURING CLIMB ECAM - AIR ENG 2 BLEED FAULT GROUNDED - YES. COMPLETED RMA 3391 - PERFORMED TEST OF THE FAN AIR VALVE AND SENSE LINE PER AMM AMM 36-11-00NO DEFECT NOTED REMOVED + REPLACE FAN AIR VALVE THERMASTAT PER AMM 36-1-43 OPS CHECK GOOD - ACFT RETURNED NSDR ASAA2019101531096Floorboard · delaminatedFLOOR BOARD 231VF SOFT/ DELAM GROUNDED - YES. RECEIVED NEW FLOOR PANEL P/N E5367190600000. FLOOR PANEL INSTALLED ON CUSTOMER CARD NUMBER 5300-INST-320-01 OPS 2224 JPD STEP 017.SDR AALA201910169014Window Frame · crackedAIRCRAFT WAS GROUNDED: FLIGHT DECK RIGHT HAND SLIDING WINDOW LATERAL WINDSHIELD FRAME VERTICAL STIFFENER CRACKED AT FR 4. REPAIRED WINDOW FRAME PER EA 299400.SDR AALA2019101759055Engine · odorAIRCRAFT WAS GROUNDED: FLIGHT ATTENDANTS REPORTED ODOR AT CRUISE DESCRIBED AS SWEET OR ANTI-FREEZE MID TO AFT CABIN. NO ODOR IN FLIGHT DECK, COMPLIED WITH QRH ODOR PROCEDURE WITH NO CHANGE REPORTED FROM FLIGHT ATTENDANTS. MAINTENANCE REPORTS SOURCE OF ODOR FROSDR WX0A219101473431Power Supply · no testEPSU 13WL FAILED DURING CABIN EMERGENCY LIGHTING TEST / R&R EPSU"SDR WX0A2019101473430Power Supply · no testEPSU 10WL FWD L FAILED DURING CABIN EMERGENCY LIGHTING / R&R EPSU"SDR WX0A2019101473429Power Supply · no testLT & RT OVERWING EPSU FAILED TO TEST. R & R THE EPSU.SDR ANCF201910281201Smoke Warning · false activationSMOKE. OCT 12. ENGINES STARTED AVNCS SMOKE ON ECAM APPEARED - AFTER PUSH BACK AND ENGINES STARTED AVNCS SMOKE ON ECAM APPEARED DURING POWER MASTER FROMAPU TO ENGINES // CORRECTIVE ACTIONS: OCT 14. WAS TRANSFER WITH MEL 21-26-02IS TRANSFER EXTRACTOR FAN CAT C.WSDR WX0A1900010074272None · none(VDR ID 32512) FIVE OBLONG/ DOUBLE DRILLED HOLES B/T FRAME #33 AND #34 IN A FLOOR BEAM WEB NEAR STRINGER 38R. C/W STS EA 24-2019-025 TO ACCOMPLISH REPAIR./COMPLETED REPAIR WEB BEAM FLOOR BETWEEN FR 33 & 34 IAW EA # 20-2019-025 & EA # 74-2019-002"SDR WX0A520191021434Slide · defectiveDEFECT NOTED ON LH OFFWING ESCAPE SLIDE / R&R ESCAPE SLIDE"SDR ASAA2019101410992Warning Light · false activationNR 2 ENGINE SMR T3 FAULT T3 SENSOR J13, ECU GROUNDED - YES. REF TSM TASK 77-20-00-810-829-A. PERFORMED FADEC NON-MOTOR TEST ENG 2 CHA & CHB. NO FAULTS DETECTED.SDR AALA2019101429012Fmc · malfunctionedAIRCRAFT NOT GROUNDED: PILOT REPORTS FLIGHT DIRECTION KILLED OFF AND AUTOTHRUST DID NOT ENGAGE ON TAKEOFF. ON AUTOPILOT AIRCRAFT DID NOT FOLLOW VERTICAL GUIDANCE ON CHSLY4RNAV ARRIVING TO CLT. ALMOST BUSTED TWO LOWER CONSTRAINTS. MAINTENANCE RESET FCU 1&2 IAW SDR ASAA2019101193990Warning Message · false indicationANTI-ICE CAPTAIN AOA DURING CRUISE PL 380 TAT - 35 SAT - 62C GROUNDED - YES. PERFORMED TS 30-31-00-810-809-A LOSS OF POWER SUPPLY FOR THE ANGLE OF ATTACK SENSOR AND OPS TEST OF PROBE ICE PROTECTION IAW AMM 30-31-00-710-001 OPS CHK GOOD A/C OK FOR SERVICESDR AALA2019101099010Light · inoperativeAIRCRAFT NOT GROUNDED: MAINTENANCE REPORTS EMERGENCY LIGHT ON SEAT 4C INOPERATIVE. REMOVED AND REPLACED EMERGENCY LIGHT AND HARNESS CABLE ON SEAT 4C IAW AMM 33-51-19. OPS TEST GOOD.SDR ASAA2019102971147Fitting · crackedCRACK INDICATION FOUND USING ULTRASONIC INSPECTION, LH ACTUATOR FITTING, AFT LUG, FORWARD FACE PER REJECTION CRITERIA OF NTM PROCEDURE. GROUNDED - YES. REMOVED AND REPLACED L/H ACTUATOR FITTING IAW ALASKA EA# A320-53EA-00138. THIS IS A CATEGORY "A" REPAIR. (LSDR AALA2019100989007Contactor · burnedAIRCRAFT NOT GROUNDED: MAINTENANCE REPORTS ELECTRICAL BURNING SMELL IN AC POWER DISTRIBUTION CONTACTORS RACK 107VU. FOUND AVIONICS VENT BLOWER FAN CONTACTOR MICRO SWITCH RELAY BURNED FIN 8HQ. REMOVED AND REPLACED CONTACTOR RELAY 8HQ IAW ESPM 20-45-24-0101-1.SDR WX0A2019100973427Power Supply · inoperativeL2,R2 DOORS AND CENTER REAR CEILING EMERG. EXIT LIGHTS INOP / R&R AFT EPSU"SDR ASAA2019102841107Floor Support · corrodedMAIN CABIN FLOOR STRUCTURE, FR69 TO FR70, R/H FRAME SUPPORT IS CORRODED. GROUNDED - YES. REMOVED AND REPLACED R/H FRAME SUPPORT IAW A320 SRM 51-44-11 AND AIRBUS DRAWING D53474180. FRAME SUPPORT HAS NO ALLOWABLE DAMAGE IN SRMSDR ASAA2019102841106Floor Support · corrodedMAIN CABIN FLOOR STRUCTURE, FR69 TO FR70, L/H FRAME SUPPORT IS CORRODED. GROUNDED - YES. FRAME SUPPORT HAS NO ALLOWABLE DAMAGE IN SRM. REMOVED AND REPLACED L/H FRAME SUPPORT IAW A320 SRM 51-42-11SDR ASAA2019102143032Threshold · corrodedAFT CARGO DOOR THRESHOLD PLATE AT FR.53 CORRODED O/B OF TORSION BOX GROUNDED - YES. REMOVED AND REPLACED AFT CARGO DOOR THRESHOLD PLATE IAW A320 SRM 51-72-11-911-001 AND AIRBUS DWG E53470500SDR ASAA2019100430906Warning Message · false activationAFTER LANDING, FUEL L & R OUTER XFR OPEN ON ECAM GROUNDED - YES. PERFORMED FUNCTIONAL (BITE) TEST OF FLSS CH1 & CH2 NO FAULTS. REF. AMM 28-46-00-740-00-A. ECAM MSG FUEL L&R OUTER XFR OPEN WERE NOT PRESENTSDR ASAA2019100730907Apu · shutdownAPU AUTO SHUTDOWN. GROUNDED - YES. PERFORMED TEST AND RESET OF APU. OPS CK GOOD PER A320 AMM 49-00-00.SDR ASAA2019111431321Shear Plate · corrodedR/H LATERAL SHEAR PLATE AT C69/70 CORRODED. GROUNDED - YES. REMOVED AND REPLACED RH LATERAL SHEAR PLATE AT C69/70 IAW A320 SRM 51-42-11, 51-44-11, AND DWG D53474180SDR ASAA20191031177Floor Support · corrodedC67/68 R/H, FLOORBEAM CORRODED AT FASTENER HOLES NEAR SCUFF PLATE. GROUNDED - YES. REMOVAL OF DAMAGE NOT ACCOMPLISHED AFTER REAMING HOLES TO MAX ALLOWABLE SIZE PER A320 SRM 53-41-14. CONTINUED WITH REPAIR #3. CUT OUT DAMAGE PER A320 SRM 53-41-14. FABBED REPAIRSDR ASAA2019102931146Shear Plate · corrodedL/H LATERAL SHEAR PLATE AT C69/70 CORRODED GROUNDED - YES. SHEAR PLATE HAS NO ALLOWABLE DAMAGE LIMITS GIVEN IN A320 SRM. REMOVED AND REPLACED SHEAR PLATE IAW A320 SRM 51-42-11.SDR ASAA2019102931145Floor Support · corrodedMAIN CABIN FLOORBEAM, C69/70 Y160, UPPER SURFACE CORRODED GROUNDED - YES. CORROSION ON FLOOR BEAM FOUND TO HAVE 100% MATERIAL LOSS. REMOVED AND REPLACED FLOOR BEAM IAW A320 SRM 51-42-11.SDR ASAA2019102931144Seat Track · corrodedMAIN CABIN FLOOR, FORWARD RIGHT SIDE, SEAT TRACK BEAM BETWEEN FLOOR PANELS #232EF & 232FF CORRODED (DOTS: F044, F045) FR 20 - FR 21, BS 8077 - BS 8197, RBL 51, BL -Y1290 GROUNDED - YES. REMOVED CORROSION FROM SEAT TRACK ORIGINAL THICKNESS .087, REMOVED .038, RSDR ANCF201910280201Electrical Box · odorSMOKE. OCT 2. IFE SYS ROWS 7.8,9,10 ABC IN MIDDLE OF FLIGHT SHUTTED DOWN WITH MODERATE BURNED SMELL IFE GENERAL SYS DISCONNECTED // CORRECTIVE ACTIONS: OCT 2. SYST RESETED IFE REMAINS DISCONNECTED ON SEAT SEAT ROW 9ABC, ROW SEAT 7,8 AND 10 OPERSATED AND CHECK SDR ASAA2019102131031Web · corrodedAFT CARGO TORSION BOX UPPER WEB AT FR. 56 HAS CORROSION. GROUNDED - YES. REMOVED AND REPLACED AFT CARGO TORSION BOX WEB IAW A320 SRM 51-42-11 AND AIRBUS DWG 17E53470321.SDR ASAA2019100493905Warning Message · false activationECAM "COND HOT AIR" FAULT. GROUNDED - YES. FAULT NOT PRESENT ON PFR OR ECAM. PERFORMED TEMP CONTROL TEST IN CFDS PASSED. OPERATED PACKS WITH APU BLEED. NO FAULTS. REF 21-63-00.SDR AALA2019100199028Floor Panel · delaminatedAIRCRAFT WAS GROUNDED: AFT CARGO COMPARTMENT FLOOR PANEL 151LF DELAMINATED. REPLACED FLOOR PANEL PER AMM 53-22-14-400-802-ASDR AALA2019100199027Floor Panel · delaminatedAIRCRAFT WAS GROUNDED: FORWARD CARGO COMPARTMENT FLOOR PANEL 131EF DELAMINATED. REPLACED FLOOR PANEL PER AMM 53-22-14-000-001-A.SDR ASAA2019092830861Apu · shutdownAPU AUTO SHUT DOWN GROUNDED - YES. ON DEFERRAL PER LOGPAGE 8045652: VERIFIED APU AUTO SHUTDOWN WAS ON ECAM. RELEASED PER MEL 49-10-01-01. M PROCEDURES C/W. MEL LOG UPDATED. PLACARD INSTALLED. AUTHORIZED BY SEAMC. MDDR 71467 ISSUED.SDR ASAA2019092730860Control Unit · failedAUTO FLT FCU 1 FAULT GROUNDED - YES. R & R FCU IAW AMM 22-81-12 PB 401 OPS CHK GOOD , A/C RELEASED FROM MEL 22-81-01-01-A MAINT PROC REVERSED, MDDR 71435 REMOVED PLACARD REMOVED , LOG UPDATED , MCC JOE NOTIFIEDSDR ASAA2019092730859Warning System · false activationHOT AIR FAULT WHEN PACK 1 ONLY OK ON PACK 2 OR PACK 1+2 GROUNDED - YES. CYCLED A/C POWER PACK ONE OPS CHECK GOOD PER AMM 21-61-00SDR ANCF2019102892401Engine · stalledSEP 24. DURING TAKE OFF JUSTON INITIAL CLIMB E FELT 3 STALLS FROM ENGINE N-2 THE EGT REACHES 944 C° WE RETURN TO BOGOTA AS PER COMPANY POLICE PLEASE DOWNLOAD THE CVR AND THE FDR // CORRECTIVE ACTIONS: SEP 25. IN ACCORDANCE WITH TSM 73-00-00-810-866-A.THE BOROSSDR ASAA2019092430819Warning System · false activationCLASS II AIR BLEED MAINTENANCE STATUS MSG GROUNDED - YES. RESET FWC 1 & 2 PER AMM 36-00-00. OK FOR SVCSDR ASAA2019092430818Warning System · false activationUPON MANUAL ENGINE START WITH EXTERNAL AIR ENGINE STARTED SUCCESSFULLY BUT WITH ECAM IGN A FAULT IGN B FAULT. GROUNDED - YES. ENG 1 IGN B ON MEL. T/SHOOT C/OUT PER TSM 74-00-00-810-802A, FOUND OK. IGNITION TEST ON SYS A PASSED PER AMM 74-00-00-710-043. ENGINESDR ASAA2019092430817Not Reported · leakingGATE RETURN FOR FUEL LEAKAGE ASSOSIATED WITH MEL 28-20-01-A GROUNDED - YES. PERFORMED BITE TEST 28-15-00-740-002-A AND TRANSFERRED AND BALANCED FUEL LOAD NO FAULTS NOTED.SDR ASAA2019092330815Warning System · false activationFUEL MODE SELECTOR FAULT GROUNDED - YES. PERFORMED BITE TEST PER AMM TASK 28-15-00-740-002-A. NO FAULTS NOTED.SDR ANCF2019102892201Engine · failedATB. SEP 22. ATB: DURING LIFT OFF ENG 2 FAIL + ENG 2 SHUT DOWN // CORRECTIVE ACTIONS: OCT 9. IN ACCORDANCE WITH JIC -32S-71-000245 RV 00 AND AMM 71-00-00-000-042-A/400-042-A THE ENGINE 2 WAS REMOVED AND REPLACED, THE OPERATIONAL TESTS WERE PERFORMED WITH SATIS