SDR AALA2018100219021Access Panel · corrodedCORROSION ON THE ACCESS PANEL 640BB, RIGHT WING BETWEEN RIBS 5 TO 6. REPLACED THE ACCESS PANEL IAW AMM 57-27-11-400-002-A.SDR AALA201808299002Slide · unsecureFOUND DOOR L4 SLIDE STARTING TO COME OUT OF ITS PACK. REPLACED DOOR L4 ESCAPE SLIDE ASSEMBLY IAW AMM 26L00025010.SDR AALA2018083179035Cover · brokenL1 DOOR HINGE COVER BY THE MIDDLE HINGE, SAFETY RELEASE PIN, FOUND BROKEN. REPLACED L1 DOOR HINGE COVER IAW AMM 52-11-11.SDR AALA2018091879043Floor Panel · delaminatedDELAMINTION ON FLOOR PANEL 211JF. REPLACED THE FLOOR PANEL IAW AMM 53-12-11-400-001-A.SDR AALA201809179056Floor Support · corrodedCORROSION FOUND ON THE FLOOR SUPPORT AT FRAME 47.1, IN THE PASSENGER CABIN. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11.SDR AALA2018091109002Support · corrodedCORROSION FOUND ON THE SHAPE SILL IN THE AFT GALLEY AREA, FRAMES 66 TO 68, STRINGER 23L. REPLACED THE SILL IAW SRM 51-72-11 AND DRAWING D53480505.SDR F3LA2018082800412Unknown · odorFUME EXPOSURE DURING DESCENT. ODOR OF MUSTY SOCKS NOTICED THROUGHOUT CABIN. STRONGEST ODOR BETWEEN EXIT ROWS. NR 1 PACK OFF DECREASED STRENGTH OF ODOR.SDR AALA2018082879069Lens · missingEMERGENCY LIGHT LENS WAS MISSING AT SEAT 8 ABC. REPLACED THE LENS IAW 33-50-00.SDR AALA2018082879068Lens · missingEMERGENCY LIGHT LENS WAS MISSING AT SEAT 8 ABC. REPLACED THE LENS IAW 33-50-00.SDR AALA2018082879067Lens · missingEMERGENCY LIGHT LENS WAS MISSING AT SEAT 8 ABC. REPLACED THE LENS IAW 33-50-00.SDR AALA2018082879066Lens · missingEMERGENCY LIGHT LENS WAS MISSING AT SEATS 3C. REPLACED THE LENS IAW 33-50-00.SDR AALA2018082879024Lens · missingEMERGENCY LIGHT LENS MISSING AT SEATS 3A, C AND 8 ABC. REPLACED THE LENSES IAW 33-50-00.SDR AALA201810029003Shear Plate · corrodedCORROSION FOUND THE ON SHEAR PLATE AT STRINGER 23R, BETWEEN FRAMES 69 - 70. REPLACED THE SHEAR PLATE IAW SRM 51-72-11, AND DRAWING D53477180.SDR AALA2018092179062Floor Panel · delaminatedDELAMINATION ON FLOOR PANEL 222CF. REPLACED THE FLOOR PANEL IAW AMM 53-00-00-400-801-A.SDR AALA201809179046Floor Support · corrodedCORROSION FOUND ON THE FLOOR SUPPORT, +Y1292, BETWEEN FRAMES 64 AND 66. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, 51-42-11, AND DWG D53472815.SDR AALA201809179029Seat Track · corrodedCORROSION FOUND ON THE SEAT TRACK, -Y765 BETWEEN FRAMES 12 AND 24. REPLACED THE SEAT TRACK IAW SRM 51-72-1,1 DRAWINGS D53110920, AND D53112814.SDR AALA201809149018Seat Track · corrodedCORRODED SEAT TRACK BETWEEN FRAMES 12 TO 24. REPLACED THE SEAT TRACK IAW SRM 51-72-11, AND DRAWING D53110920.SDR AALA201809129011Floor Support · corrodedCORROSION FOUND ON THE FLOOR SUPPORT, FRAMES 64 TO 66, -Y765. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, AND DRAWING D53472190.SDR AALA201809119001Floor Support · corrodedCORROSION WAS FOUND ON THE FLOOR SUPPORT BETWEEN FRAMES 64 AND 66, Y765. REPAIRED THE FLOOR SUPPORT IAW SRM 51-72-11, 51-42-11, AND DWG D53472815.SDR AALA201809119024Support · corrodedCORROSION FOUND ON LOWER SUPPORT BETWEEN FRAMES 66 - 68, STRINGER 23R. REPLACED THE SUPPORT IAW SRM 51-72-11, DRAWING D53480505, AND 53-41-14, REP 1.SDR AALA201809119020Support · corrodedCORROSION FOUND ON THE LOWER SUPPOERT EXISTING REPAIR, AT FRAME 66 AND STRINGER 23L IN THE AFT GALLEY. REPAIRED THE SUPPORT IAW SRM 53-41-14-300-001.SDR AALA201809109003Floor Support · corrodedCORROSION WAS FOUND ON FLOOR SUPPORT BETWEEN FRAMES 68 - 69. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, 51-42-11, AND DRAWING 53472780.SDR AALA2018090759013Floor Panel · delaminatedDELAMINATION ON FLOOR PANEL 221EF AT FRAMES 16 TO 20, Y254 TO Y1292. REPLACED THE FLOOR PANEL IAW SRM 53-12-00-300-006, FIGURE 20106, AND IRM 9701, REVISION H.SDR AALA201809059021Floor Panel · delaminatedDELAMINATION FOUND ON FLOOR PANEL 221PF IN THE FWD GALLEY AREA LOCATED BETWEEN FRAMES 12 - 16, Y765 AND Y1292. REPLACED THE FLOOR PANEL IAW SRM 53-12-00-300-006, FIG 20106, AND IRM 9701, REV H.SDR AALA201809059017Floor Panel · delaminatedDELAMINATION FOUND ON FLOOR PANEL 232FF IN THE FORWARD GALLEY, FRAMES 20 - 24. REPLACED THE FLOOR PANEL IAW SRM 53-12-00-300-006, FIGURE 20106, AND IRM 9701, REVISION H.SDR AALA201809059010Floor Panel · delaminatedDELAMINATION FOUND ON FLOOR PANEL 222EF IN THE FORWARD GALLEY AREA. REPLACED THE FLOOR PANEL IAW SRM 53-12-00-300-006, FIGURE 20106, AND IRM 9701, REVISION H.SDR AALA201809059019Floor Panel · delaminatedFLOOR PANEL 231BF DELAMINATED BETWEEN FRAMES 20 TO 24, Y254 TOY-254 IN THE FORWARD GALLEY. REPLACED THE FLOOR PANEL IAW SRM 53-12-00-300-006, FIGURE 20106, AND IRM 9701, REVISION H .SDR AALA201808249010Bolt · looseFLIGHT ATTENDANT REPORTED THE L2 DOOR ARM - DISARM LEVER HAD EXCESSIVE PLAY. TIGHTENED THE BOLT ON THE L2 DOOR ARMING LEVER. OK FOR SERVICE.SDR DALA2018082305215Power Supply · no testEMERGENCY LIGHT TEST FAILED. FAULTED EPSU 10WL, REPLACED THE POWER SUPPLY AND BATTERY 10WL.SDR AALA201809249007Floor Panel · delaminatedDELAMINATION ON FLOOR PANEL 262BG IN THE AFT GALLEY. REPLACED THE FLOOR PANEL IAW EA 284341.SDR AALA201809189015Frame · crackedFRAME 20 CRACKED, STRINGER 22R. REPAIRED THE FRAME IAW EA 283955.SDR AALA201809149013Intercostal · crackedCRACK INDICATIONS FOUND ON THE INTERCOSTAL FOR DOOR STOP NR 7, FRAME 16. REPLACED THE INTERCOSTAL IAW SRM 51-72-11M, AND DRAWING D53112300.SDR AALA201809119021Intercostal · crackedCRACK INDICATIONS ON THE INTERCOSTAL FOR DOOR STOP 7 AT FASTENER HOLES 1 & 3, LOCATED AT FRAME 16 RIGHT. REPLACED THE INTERCOSTAL IAW SRM 51-72-11 AND DRAWING D53112300.SDR AALA201809059015Floor Panel · delaminatedDELAMINATION ON FLOOR PANEL 251WF, FRAMES 62 TO 64, Y765 TO -Y765. REPLACED THE FLOOR PANEL IAW SRM 53-12-00-300-006, FIGURE 20106, AND IRM 9701, REVISION H.SDR AALA201809059018Floor Panel · delaminatedDELAMINATION FOUND ON FLOOR PANEL 261PF IN THE AFT GALLEY AREA BETWEEN FRAMES 68 - 70, Y1292 THRU -Y1292. REPLACED THE FLOOR PANEL IAW SRM 53-12-00-300-006, FIG 20106, AND IRM 9701, REV H.SDR AALA201809059007Floor Panel · delaminatedDELAMINATION FOUND ON FLOOR PANEL 261BG, IN THE AFT GALLEY AREA BETWEEN FRAMES 64 - 66, Y765 TO Y1732. REPLACED THE FLOOR PANEL IAW SRM 53-02-00-300-011, AND IRM 9701, REV H.SDR AALA201809059006Floor Panel · delaminatedDELAMINATION FOUND ON FLOOR PANEL 261AG IN THE AFT GALLEY BETWEEN FRAMES 64 - 66, Y254 THRU -Y254. REPLACED THE FLOOR PANEL IAW SRM 53-02-00-300-011, AND IRM 9701, REV H.SDR F3LA2018082700405Battery · no testDURING A HEAVY CHECK, THE EMERGENCY LIGHT BATTERY AT 15WL FAILED TO TEST THRU MCDU. REMOVED AND REPLACED EPSU ASSY IAW AMM 33-51-38-PB 401, CONF 00. OPS CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.SDR F3LA2018082700404Battery · failedDURING HEAVY CHECK, EMERGENCY LIGHT BATTERY 13WL FAILED TO TEST THRU MCDU. REMOVED AND REPLACED EPSU ASSY IAW AMM 33-51-38-PB, 401, CONF 00. OPS CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.SDR F3LA2018082700403Battery · no testDURING A HEAVY CHECK, EMERGENCY LIGHT BATTERY 11WL FAILED TO TEST THRU MCDU. REMOVED AND REPLACED EPSU ASSY IAW AMM 33-51-38-PB 401, CONF 00. OPS CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.SDR AALA2018082749013Actuator · defectiveDURING CRUISE, FLIGHT FUEL CENTER RT TRANSFER FAULT MESSAGE APPEARED. REPLACED THE RIGHT JET PUMP CONTROL VALVE ACTUATOR 12QL IAW AMM 28-26-51. OPS CHECKED GOOD.SDR AALA201810019022Skin · corrodedCORROSION TO UPPER SURFACE EXTERNAL SKIN BETWEEN RIBS 4 TO 5, ON THE LT WING BETWEEN WING STA 2440 TO 2300. REPAIRED THE SKIN IAW EA 284511.SDR AALA2018091879032Skin · corrodedCORROSION FOUND ON THE UPPER SURFACE SKIN BETWEEN RIBS 5 TO 6, STRINGER 17R ON THE RIGHT WING. REPAIRED THE SKIN IAW SRM 51-21-11-283-014.SDR AALA201808239024Bottle · low pressureL2 DOOR ASSIST BOTTLE READ LOW PRESSURE. CHARGED THE L2 DOOR EMERGENCY OPERATION CYLINDER IAW AMM 52-22-00.SDR AALA201808239023Bottle · low pressureL3 DOOR ASSIST BOTTLE READ LOW PRESSURE. CHARGED THE L3 DOOR EMERGENCY OPERATION CYLINDER IAW AMM 52-22-00.SDR AALA201808239022Bottle · low pressureR2 DOOR ASSIST BOTTLE READ LOW PRESSURE. CHARGED THE EMERGENCY OPERATION CYLINDER IAW AMM 52-22-00.SDR F3LA2018082100394Unknown · odorAIR TURN BACK DUE TO THE FA REPORTED A ROTTEN EGG, DIRTY SOCK ODOR. DURING CLIMB OUT, WITH BOTH PACKS ON. AFTER TURNING THE NR 2 PACK OFF, THE ODOR WAS STILL APPARENT AND RETURNED TO DEPARTURE. PERFORMED IDENTIFICATION OF CABIN ODOR IAW AMM 05-50-00-810-83SDR DALA2018082315214Sign · brokenEMERGENCY LIGHT AND LENS BROKEN AT THE R4 DOOR BOTTOM. R & R TH EMERGENCY EXIT SIGNSDR AALA2018082109028Warning Light · illuminatedNR 2 ENGINE BLEED FAULT, HOT ACRID ODOR WITH NOTABLE HEAT INCREASE IN COCKPIT TEMPERATURE NOTICED BEFORE THE NR 2 BLEED FAULT. NR 1 & 2 ENGINE BLEED SYSTEM OPS CHECKED GOOD IAW AMM 36-11-00-710-003A. ACCOMPLISHED J/C 26L00021001 WITH NO FINDINGS OF ODOR IAWSDR F3LA2018082100397Unknown · odorDIVERTED DUE TO THE FAS REPORTED A STRONG ELECTRICAL BURNING ODOR BETWEEN THE L1, L2, AND R2 DOORS. NOTABLE MORE ON LEFT SIDE OF THE ACFT. ODOR WAS STRONG AT FIRST DURING CLIMB THEN STARTED TO DISSAPATE. THE ODOR LINGERED THROUGHOUT THE 15 MINUTE FLIGHT.
Back to Airbus A321-211