Airbus A330-243
Service difficulty reports · 5,643
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A330243' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A330243' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HALA20241209350Oil System · leakingETOPS - FOUND #1 ENG LEAKING OIL FROM INLET CONE. REMOVED AND REPLACED #1 ENG FAN SHAFT COVER PACKING PER AMM 71-15-00/801.SDR HALA20241209352Heat Exchanger · leakingETOPS - DURING PDSC, NOTED OIL COATING #2 ENG FROM HEAT EXCHANGER AREA & OIL LEVEL AT -2. FILLED OIL & RAN #2 ENG @ IDLE FOR 5 MINS. DISCOVERED SIGNIFICANT OIL LEAK FROM HEAT EXCHANGER MATRIX. REMOVED & REPLACED #2 ENG AOHE PER AMM 79-21-51. OPS & LEAK CHECK GSDR HALA20241209351Transfer Valve · faultedETOPS - FUEL AFT XFR INOP ENTIRE FLIGHT. REPLACED RH FUEL AFT XFR VALUE PER AMM 28-27-54-04. OPS TEST GOOD PER AMM 28-51-00-710-801. A/C OK FOR SERVICE.SDR HALA20241209354Seal · brokenETOPS - ENG #2 FILLER #21 SEALS BROKEN. REPLACED ANNULUS FILLER PER AMM 72-31-41-400-802-ASDR HALA20241203348Chip Detector · false indicationETOPS - AFTER LANDING ECAM ENG 1 OIL CHIP DETECTED. INSPECTED ENGINE #1 MCD PER AMM 79-00-00-200-806-A. FOUND NO EVIDENCE OF CONTAMINATION. REMOVED & REPLACED EMCD PER AMM 79-22-46-000-811-A. TEST PASS.SDR HALA20241202078Cover · broken4L DOOR EMERGENCY EXIT LIGHT SIGN INOP. REPLACED BROKEN EMERGENCY EXIT LIGHT COVER. COND / SECURITY / OPS CHK OK.SDR HALA20241202347Circuit Card · malfunctionedETOPS - ENG 2 MINOR FAULT. PERFORMED TSM 73-21-809-810-817-A. REMOVED AND REINSTALLED DATA ENTERY PLUS PER AMM 73-21-12. INSPECTED PINS PER 70-50-02-910-802-A .NO DEFECT NOTED. PERFORMED ENG RUN PER AMM 72-00-00-860-816-A.NO DEFECTS NOTED NO FAULTS ON MOTORSDR HALA20241129344Wire · damagedETOPS - FOUND INTERCONNECTING WIRE 18HFON L WING PNEUMATIC LEAK DETECT LOOP A, WITH HIGH RESISTANCE 125 OHMS. REPLACED INTERCONNECTING WIRE 18HF PER AMM 36-22-19-400-803-A. PERFORMED TSM 36-11-81-810-801-A AND CLEANED CONNECTIONS 15HF, 13HF, 91HF, 92HF, 93HF, SDR HALA20241129342Filler · crackedETOPS - #2 ENGINE NUMBER 10 BLADE ANNULUS FILLER CRACKED TAB. REPLACED RIGHT ENGINE NUMBER 10 BLADE ANNULUS FILLER PER AMM 72-31-41-400-802A. OK FOR SERVICE.SDR HALA20241129343Control Unit · faultedETOPS - PERFORMED TEST OF THE VSV SYSTEM PER AMM 75-33-00-740-80LA. TEST FAILED. PERFORMED ENG#2 RUN. FAULT CONFIRMED. ENG 2 CTL. SYS FAULT" BLUE TO DO MSG" SHUT ENG DOWN". FURTHER T/S REQ. REMOVED AND REPLACED VSV CONTROL UNIT, PER AMM 75-33-51, UP TO STEPS.SDR HALA20241125335O-Ring · leakingETOPS - FOUND HYDRAULIC LEAK FROM GREEN MANIFOLD- BRK LINE- LEADING EDGE FLAPS. REPLACED O-RING ON GREEN MANIFOLD LINE LABELED L.E. FLAPS PER AMM 29-11-53. LEAK CHECK GOOD OK FOR SVC.SDR HALA20241125334Engine · making metalETOPS - ENG 1 OIL CHIP DETECTED. REMOVED EMCD AND INSPECTED PER AMM 79-00-00-200-822-A. FOUND ONE FLAKE, ACCEPTABLE DEBRIS. REINSTALLED EMCD PER AMM 79-22-46-400-811. REMOVED AND INSPECTED SVAVENGE FILTER PER AMM 79-22-45-000-81. NO DEBRIS FOUND. INSTALLED NEWSDR HALA20241122331Gasket · leakingETOPS - DURING ROUTINE TASK CARD OF ENG 2. FOUND LEAK AT GREEN SYS EDP. REMOVED AND REPLACED GEARBOX MATING SURFACE GASKET. REMOVED AND REINSTALLED EDP IN REF TO AMM 29-11-51. OPS CHECK GOOD LEAK CHECK GOOD.NO FAULTS NOTED.SDR HALA20241120076Skin · damagedRAMP AGENT REPORTED FOUND HOLE AT BULK CARGO DOOR. DAMAGE IS LOCATED BTWN FR68 & 69, AND BTWN 5 & 6. DAMAGE WAS NOTED TO BE 0.7IN BY 0.8IN, AND DEPTH OF 0.3IN. ACCOMPLISHED BULK CARGO DOOR EXTERNAL SKIN DAMAGE REPAIR PER E105-C20112-INI. A/C OK FOR SVC.SDR HALA20241120329Computer · malfunctionedETOPS - DURING FLIGHT F. USED 1 AND F. USED 1+2 STOPPED COUNTING UP. LAST 3 DIGITS SHOWED AMBER DASHES. F. USED 2 NORMAL. REMOVED AND REPLACED FCMC 2 PER AMM 28-51-34. TEST OK. RAN BOTH ENGINES AT IDLE PER AMM 31-00-00. NO DEFECTS NOTED. OK FOR SVC.SDR HALA20241119073Battery · faultedEMERGENCY LIGHTS CAME ON DURING FLIGHT. WE RESET LIGHTS. EMERGENCY LIGHTS CAME ON AGAIN AT 1000' ( LEFT SIDE ONLY). REMOVED & REPLACED BATTERY AT 15WL &18WL. PER AMM 33-51-38 OPERATIONAL CHECK OK.SDR HALA20241119328Computer · faultedETOPS - DURING PDSC "FCMC 1 FAULT". REMOVED AND REPLACED FCMC 1 PER TSM 28-51-00-810-801-A. NO FAULTS NOTED.SDR HALA20241118327Fcu · faultedETOPS - ALTITUDE SELECTOR ON FCU LOOSE. DOES NOT FUNCTION PROPERLY. REMOVED AND REPLACED FCU PER AMM 22-81-12. LAND CAT 3 CAPABILITY TEST OK PER AMM 22-97-00. OK FOR SVCSDR HALA20241115325Drain Mast · leakingETOPS-ON PDC FOUND #2 ENG LEAKING FUEL FROM DRAIN MAST. REMOVED AND REPLACED FUEL DRAIN TANK EJECTOR PER AMM 71-71-42. LEAK STOPPED. OK FOR SVC.SDR HALA20241114324Igniter · failedETOPS-SMI 537252 - CREW PLACARD #2 ENG IGN B FAULT (IGNITION SYSTEMS B). REMOVED AND REPLACED #2 ENG IGNITER B REF AMM 74-21-51. OPS TEST GOOD. OK FOR SERVICE. MIC SHEET CLEARED. PLACARD REMOVEDSDR HALA20241112323Chip Detector · false indicationETOPS-REPEAT WRITE UP AFTER LANDING ECAM ENG 1 OIL CHIP DETECTED. PERFORMED TSM 79-20-00-810, FOUND DAMAGED PIN ON EMCD. REMOVED AND REPLACED SCAVANGE OIL FILTER [21195 DM]. NO DEBRIS FOUND ON EMCD. NO DEBRIS FOUND ON THE FILTER. PER AMM 79-22-45. PERFORMED LESDR HALA20241112322Transceiver · inoperativeETOPS-HF RADIOS UNABLE TO TX. REMOVED AND REPLACED HF1 TRANSCEIVER PER AMM 23-11-33. BITE TEST OF HF TRANSCIEVER GOOD. OK TO CONTINUE SERVICESDR HALA20241108320Handset · malfunctionedETOPS - 1L FLIGHT ATTENDANT HANDSET - PA FUNCTION EXTREMELY LOW VOLUME. REPLACED HANDSET ASSY PER AMM 23-73-44. OPS CK OK. OK FOR SERVICESDR HALA20241108319Interphone · inoperativeETOPS - 4L INTERPHONE INOP. REPLACED 4L INTERPHONE PER AMM 23-73-44. OPS CK OK. OK FOR SERVICESDR HALA20241108318Heater · faultedETOPS - A.ICE LEFT WSHLD HEAT INOP. ACCOMPANIED WITH 2 CRACKS IN WSHLD. REMOVED AND REPLACED WHC PER AMM 30-42-34. OPS CHECK OF WHC 1 GOOD. OK FOR SERVICE. REMOVED LEFT WINDSHIELD PER AMM 56-11-11. INSTALLED LEFT WINDSHIELD PER AMM 56-71-11. BITE TEST OF WINDSDR HALA20241106314A/C Pack · faultedETOPS - AIR PACK 2 REG FAULT. REMOVED AND REPLACED 522HH6 PER AMM 21-53-11. OPS CHK LEAK CHK GOOD. OK FOR SVC.SDR HALA20241105313Blade · nickedETOPS - FOUND #2 ENG BLADE WITH NICK AND ARC BURN ON #13 LEADING EDGE BLADE. REMOVED AND REPLACED #2 ENG #13 LOW COMPRESSOR BLADE PER AMM 72-31-41. OPS CHECK GOOD, NO VIBE. OK FOR SVC.SDR HALA20241105314None · no discrepancyOTHER - BIRDSTRIKE ON TAKEOFF OGG MULTIPLE BIRDS, DIV TO HNL. PERFORMED INSPECTION OF BIRDSTRIKE PER AMM 05-51-14-200-803-A. NO DAMAGE NOTED ON A/C. NO EVIDENCE ON BIRDSTRIKE NOTED. OPS TES OF FLIGHT CONTOLS GOOD. A/C IS OKAY FOR SVC.SDR HALA20241105312Filter · cloggedETOPS - ENG 1 FUEL FILTER CLOG IN CRUISE. REMOVED AND REPLACED ENG 1 FUEL FILTER PER AMM 73-11-41. OPS TEST OK. NO LEAKS NOTED, OK FOR SVC.SDR HALA20241104066Switch · faultedBTB EMERGENCY LTS IN ARMED POSITION EMER LTS ON IN CABIN- RESETS UNSUCCESSFULL. REMOVED AND REPLACED EMER LIGHT SWITCH 4WL PER ESPM 20-45-21-01 AND OPS TEST PER AMM 33-51-00. OPS OK.SDR HALA20241104311Transfer Valve · faultedETOPS - DURING CRUISE FLIGHT: AMBER ECAM, FUEL OUTR TO INR FAULT. COMPLIED WITH ECAM INSTRUCTIONS. REPEAT WRITE UP. REMOVED AND REPLACED L/H INTER TANK FUEL TRANSFER VALVE ACTUATOR PER AMM 28-26-52-000-801A .OPS CHECK GOOD .OK FOR SERVICESDR HALA20241104309Oil System · leakingETOPS - DIRTY SOCK SMELL DURING DESCENT 5000FT. POWER IDLE, LASTED 1 MINUTE. PERFORMED TSM 21-00-00-810-801-A. NO OIL LEAK FOUND FROM APU. ALSO PERFORMED TSM 71-00-81-810-805-A NO OIL LEAKS NOTED FROM BOTH #1/#2 ENG. PERFORMED LEVEL A DECON. OF ECS PER AMM 21-SDR HALA20241104310Fuel Sys · faultedETOPS - FUEL DISCREPANCY AFTER TO -2000 LBS. FUEL DISCREPANCY ENROUTE -4000 LB. FUEL DISCREPANCY DESCENT -7000 LBS. AFT TANK TRANSFER AND OUTER TANK TRANSFER PUMPS ON ALL THE WAY TO GATE. FINAL FUEL DISCREPANCY -4000 LBS. FOUND FCMC 1 SHOWING 4000 LB IMBALANCESDR HALA20241101307Transceiver · faultedETOPS - HF 1 FAULTING. REMOVED AND REPLACED HF 1 TRANSCEIVER PER AMM 23-11-33/401. OPS TEST AND BITE OK. OK FOR SVC.SDR 2024FA0000794Frame · crackedDURING HFEC INSPECTION OF FR40 LH SIDE FASTENER HOLE LOCATION, FOUND H260 WITH CRACK INDICATION.SDR HALA20241028303Handset · malfunctionedETOPS - INTERPHONE FROM 1L VERY SOFT VOLUME. CAN'T HEAR PA FROM ROW 14-47. REMOVED AND REPLACED HANDSET ASSY AT 2L PER AMM 23-73-44. OPS CHECK OK. OK FOR SERVICE.SDR HALA20241029061Hydraulic System · lowGREEN LEVEL LOW HYDRAULICS ECAM ON TAXI IN WITH APPLICATION OF BRAKES. POST FLIGHT REPORT SHOWED "HYD G RSVR UNDERFILLED" AND "HYD G ENG 2 PUMP LO PR". SERVICED GREEN HYD PER AMM TASK 12-12-29-611-802-A. PERFORMED TSM 29-11-00-810-820-A & TSM 29-11-00-810-824-SDR HALA20241028302Eec · faultedETOPS - BTB ENG 2 EPR MODE FAULT AFTER ENG 1 START. REMOVED AND REPLACED ENG 2 EEC PER A330 AMM 73-21-34 OPS CHECK GOOD NO FAULTS NOTED OK FOR SVC ENGINE RUN CHECKS GOOD.SDR HALA20241025300Flex Line · leakingETOPS - (BTB) LOSS OF GREEN HYD FLUID. FOUND BRAKE MANIFOLD SPLY LINE PIC32-11-11-25 ITEM 10 DAMAGED. FLEX LINE REMOVED AND REPLACED. POST INSTALLLATION CHKS SATIS. HYD RAT EXT SOL 2 CB CYCLED. NORMAL BRAKES AND GEAR DOORS CYCLED OP NORMAL.SDR 2024FA0000854Seat Track · corrodedFOUND CORROSION ON SEAT TRACK AT FR36, Y2462 ON THE CROWN AREA AND BELOW CROWN AREA BETWEEN FR 26/27.4.SDR HALA20241024298Controller · malfunctionedETOPS - INFO TO MX. COCKPIT ZONE CONTROLLER IS MALFUNCTIONING. PER MOC. ZONE CONT RESET IN FLIGHT NO CHANGE. COCKPIT TEMP IS TOO HOT. THEN TOO COLD. AND AIR COCKPIT KNOB IS INEFECTIVE. REPLACED ZONE CONTROLLER AND CKPT TRIM AIR VALVE (637HK) PER AMM 21-63-34 ASDR HALA20241023297Actuator · faultedETOPS - BTB FUEL APU LP VALVE FAULT. REMOVED AND REPLACED APU LP VALVE ACTUATOR PER AMM 28-29-52. OPS CHECK GOOD. SECURITY CHECK GOOD. BTB AGAIN FOR SAME ISSUE. REMOVED AND REPLACED RELAY 6QF, NO CHANGE FAULT STILL ACTIVE AT SHUT DOWN.ECB RERACKED, FAULT CONTISDR HALA20241022293Blanket · puncturedETOPS - #2 ENG RH C DUCT THERMAL BLANKET PUNCTURED. LOCATED BOTTOM OF C DUCT & ROUGHLY CENTERED. REPAIRED THERMAL BLANKET PER CMM 78-30-20. OK FOR SVC.SDR HALA20241015289Interphone · weakETOPS - PA IS VERY QUIET FROM 1R INTERPHONE. REMOVED AND REPLACED 1R INTERPHONE TEST OK PER: AMM 23-73-44.SDR HALA20241015288Relay · faultedETOPS - AFTER TAKEOFF WHEN SELECTING FLAPS UP THE YELLOW HYD ELETRIC PUMP BEGAN RUNNING-GUARDED SWITCH ON LIGHT ILLUMINATED, GREEN HYD ELEC PUMP ECAM MEMO,AND ELEC PUMP RUNNING INDICATION ON SD PAGE. REMOVED AND REPLACED YELLOW HYDRAULIC RELAY (24KS2) PER ESPMSDR HALA20241015051Power Supply · inoperative3L DOOR EXIT SIGNS DO NOT ILLUMINATE. REMOVED & REPLACED 3L DOOR EXIT SIGN EPSU ASSY AND CHECKED OK PER A330 AMM 33-51-38. A/C OK FOR CONTINUE SVC,SDR HALA20241015050Power Supply · inoperative4L EXIT SIGN AND OVERHEAD EXIT INOP. REMOVED AND REPLACED ESPU (17WL) PER AMM 33-51-38. OPS CHECK TEST OK.SDR HALA20241016052Skin · damagedLH WING #7 SLAT (Z517) DAMAGEDSDR HALA20241011287Fan · inoperativeBULK CARGO VENT FAULT. DIV TO OAK. REMOVED AND REPLACED BULK CARGO EXTRACTION FAN PER AMM 21-28-53. OP CHK GOOD OK FOR SVC.SDR HALA20241011048Slide · no testWHILE PERFORMING T/C 330-335100-01-1 FOUND 3L SLIDE FAULTING. REMOVED AND REPLACED SLIDE PER AMM 25-62-42-000-801-A01 AND 25-62-42-400-801A OPS CHK GOOD. OK FOR SVC
Back to Airbus A330-243