Boeing 727-223
Service difficulty reports · 5,313
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '727223' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '727223' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA981627Frame · dentedTUL - FOUND BELL FRAME DENTED STATION 1010, BETWEEN STRINGER 26 LT AND 25 LT. INSTALLED BELL FRAME DOUBLER AT STATION 1010, BETWEEN STRINGER 26 LT AND 26 RT PER SRM 51-40-3. (M)SDR AALA981626Frame · dentedTUL - FOUND BELL FRAME DENTED. FABRICATED DOUBLER, DRILLED HOLES, TREATED AND PRIMED PER SRM 51-10-2. (M)SDR AALA981625Web · crackedTUL - FOUND 1.5 INCH CRACK IN WEB BETWEEN 2ND AND 3RD BAY CENTER TANK LBL 13.19 3 INCHES DOWN FROM TOP OF TANK. INSTALLED DOUBLER PER SRM 51-40-2. (M)SDR AALA981624Shear Tie · corrodedTUL - FOUND CORROSION ON SHEAR TIE STATION 950B BETWEEN STRINGER 28RT AND 29 RT. REMOVED DAMAGED SHEAR TIE AND REPAIRED PER SRM 53-10-4. (M)SDR AALA981623Frame · dentedTUL - FRAME STATION 700 DENTED ABOVE STRINGER 24R. REMOVED DAMAGE, REPAIRED DOUBLER SRM 51-40-3, FIG 1 SHEET 3 7075-T6, .063 INCH, 10 INCH DOUBLER, .375 AND .25 FASTENERS 20 EACH MS204700 RIVETS 2 ROWS ON SIDE, 1 ROW ON TOP. (M)SDR AALA981622Frame · dentedTUL - FUSELAGE BELL FRAME DENTED ABOVE STRINGER 24L AT FS 600. INSTALLED BELL FRAME DOUBLER PER SRM 51-40-3 PAGE 1 USING 7075-T6, .071 INCH THICK, 7 INCHES LONG, .375 INCH AND .25 INCH FASTENERS AND 20 MS 20470D RIVETS, TWO ROWS ON BOTTOM AND ONE RAN ON TOP, SDR AALA981621Frame · dentedTUL - BELL FRAME DENTED ABOVE STRINGER 24R AT FS 700. INSTALLED DOUBLER REPAIR PER SRM 51-40-3 FIG 1 SHEET 3 USING 7075 T6, .063 INCH, 10 INCH DOUBLER, .375 FASTENERS AND .25 INCH FASTENER, 20 MS2047AA RIVETS, TWO ROWS ON TOP SIDE AND ONE ROW ON TOP.SDR AALA981620Frame · dentedTUL - FUSELAGE BELL FRAME DENTED ABOVE STRINGER 23-24R AT FS 680. INSTALLED REPAIR DOUBLER PER SRM 51-4-3 FIG 1 PAGE 3 USING 7075-T6, .063 INCH THICK, 8 INCH DOUBLER, 21 MS20470D06 RIVETS TWO ROWS PAST DAMAGE AND ONE ROW ON TOP WITH 3 RIVETS AT EACH END. (M)SDR AALA981619Frame · bentTUL - FRAME 580 BENT STRINGER 23L-25L. REMOVED DAMAGE, MADE DOUBLER AND INSTALLED PER SRM 51-40-3 PAGE 3 FIG 1 DOUBLER IS .5 INCH LONG. 7075-T6, .063 T, .375 AND .25 MS2407DD RIVETS, 31 TOTAL, 4.25 INCHES AT TWO ROWS AND ONE ROW ON TOP. (M)SDR AALA981618Frame · dentedTUL - DENT IN FRAME ABOVE STRINGER 24R AT FS 660. REMOVED DAMAGED AREA AND INSTALLED DOUBLER PER 51-40-3 FIG 1 PAGE 3, 8 INCH DOUBLER OF .063 INCH 7075-T6, 20.375 MS2047DD RIVETS, THREE ROWS. (M)SDR AALA981617Frame · dentedTUL - FOUND DENT IN FRAME AT FS 600 ABOVE STRINGER 23R. REMOVED DAMAGED AREA AND INSTALLED DOUBLER PER 51-40-3 FIG 1 PAGE 3, 8 INCH DOUBLER OF .063 INCH 7075-T6, 20.375 INCH RIVETS MS2047DD, THREE ROWS. (M)SDR AALA981616Frame · dentedTUL - FRAME AT STATION 520 DENTED ABOVE STRINGER 23R. INSTALLED FRAME REPAIR PER SRM 51-40-3. REMOVED DAMAGE AREA, INSTALLED 13 INCH DOUBLER OF .073 7075-T6 WITH THIRTY FOUR .375 D-RIVETS AND FOUR .25 INCH D-RIVETS, TWO .375 INCH SCREWS AND SIX .375 INCH BOLSDR AALA981615Frame · dentedTUL - BELL FRAME DENTED AT STRINGER 26 LT AND 5 INCH ABOVE STRINGER 26 LT. INSTALLED DOUBLER .080 7075-T6 OVER DAMAGE AREA PER SRM 51-40-3. BELL FRAME DOUBLER 13.5 INCH IN LENGTH. (M)SDR AALA981614Frame · dentedTUL - BELL FRAME DENTED. SRM 51-40-3, TREATED AND PRIMED SRM 51-10-2. (M)SDR AALA981613Frame · dentedTUL - BELL FRAME DENTED STATION 1110, ABOVE STRINGER 26 RT. INSTALLED .080 7075-T6 DOUBLER OVER 1 INCH CUTOUT, TWO ROWS ON SIDE, ONE ROW ON TOP FLANGE DOUBLER 7.5 INCH BY 2.5 INCH. .375 AND .25 470DD RIVETS PER SRM 51-40-3 PAGE 1-4. (M)SDR AALA981612Frame · dentedTUL - FOUND FORWARD CARGO FRAME 720A DENTED ABOVE STRINGER 24R. REMOVED DAMAGED SECTION, INSTALLED DOUBLER 8 INCH OF 7075-T6 .063 INCH, TWENTY MS2047DD FASTENERS, THREE ROWS OF FASTENERS, THREE PAST DAMAGE EACH SIDE PER SRM 51-40-3 FIG 1 PAGE 3. (M)SDR AALA981610Shear Tie · crackedTUL - SHEAR TIE CRACKED AT STATION 540 BETWEEN STRINGER 17L AND 16L. REMOVED AND REPLACED SHEAR TIE AT FS 540 BETWEEN STRINGER 17L AND 16L PER SRM 51-10-1. (M)SDR AALA981711Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, FIRST CLASS EMERGENCY EXIT FLOOR PATH LIGHT HAS ONE LIGHT INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA981591Actuator · malfunctionedIAH - FLT 2078 - AFTER TAKEOFF AND GEAR RETRACTION, EN ROUTE TO DFW, LEFT MAIN GEAR INDICATION WAS RED WITH ASSOCIATED GEAR DOOR WARNING LIGHT ILLUMINATED. LANDING GEAR HANDLE RETURNED TO OFF POSITION LIGHTS REMAINED ON. ADDITIONALLY LEFT GEAR GREEN LIGHT ILSDR AALA981590Light · inoperativeDFW - DURING OVERNIGHT CHECK, AFT ENTRY EMERGENCY LIGHT INOPERATIVE. REPLACED AFT ENTRY EMERGENCY LIGHT ASSEMLBY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR EISA98213Indicator · malfunctionedNR 2 ENGINE OIL TEMP EXCEEDED RED LINE DURING FLIGHT. PRECAUTIONARY ENGINE SHUTDOWN ACCOMPLISHED PER FLIGHT MANUAL. FOUND NR 2 OIL TEMP BULB GROUND WIRE BROKEN AT TERMINAL BLOCK. SPLICED WIRE ON TERMINAL BLOCK IAW MM CHAPTER 20. (M)SDR AALA981577Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, AIR STAIRS OVERHEAD EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED AIR STAIRS OVERHEAD EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA981576Wire · brokenDFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING IN FIRST CLASS AND COACH, SEATS 3E THROUGH 21 INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHT STRIP WIRING AT SEAT 3E. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA981570Light · inoperativeDFW - DURING OVERNIGHT MAINTENANCE, R1 DOOR SLIDE EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED R1 DOOR SLIDE EMERGENCY EXIT LIGHT ASSEMBLY SOCKET. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR AALA981565Skin · corrodedTUL - FOUND CORROSION ON SKIN UNDER INTERCOSTAL AT LBL 8. INSTALLED DOUBLER REPAIR PER SRM 53-30-3. (M)SDR AALA981564Spar · corrodedTUL - FRONT SPAR LOWER CHORD CORRODED BELOW NR 1 KRUGER FLAP ACTUATOR FS 300 TO 305. INSTALLED REPAIR PER AARD 57-30-00-2 PAGE 1-3. (M)SDR AALA981563Stringer · crackedTUL - FOUND CRACK IN STRINGER NR 8 AT RIB ATTACHMENT TOP OF RIB. INSTALLED STRINGER REPAIR PER SB 727-57A159. (M)SDR AALA981562Skin · corrodedTUL - FOUND CORROSION ON FUSELAGE SKIN UNDER INTERCOSTAL AT STRINGER 28R, STATION 580 - STATION 600. INSTALLED DOUBLER PER SRM 53-30-3 FIG 3. (M)SDR AALA981561Skin · corrodedTUL - BELLY SKIN CORROSION UNDER STR 27R, STA 1075 - STA 1086. INSTALLED DOUBLER PER SRM 53-30-3 FIG 3. TST: 53,245 HOURS. CYCLES: 32,117. (X)SDR AALA981560Skin · corrodedTUL - SKIN UNDER INTERCOSTAL CORRODED JUST OUTBOARD OF FORWARD CARGO. INSTALLED REPAIR PER SRM 53-30-3 FIG 3. TST: 53,245 HOURS. CYCLES: 32,117. (X)SDR AALA981559Stringer · corrodedTUL - STR 27R OUTBOARD LEG CORRODED TOP EDGE STA 663. REPAIRED PER SRM 53-10-3 FIG 2. TST: 53,245 HOURS. CYCLES: 32,117. (X)SDR AALA981558Stringer · crackedTUL - STR 15R CRACKED AT END TO FIRST FASTENER AT FS 720B. REPAIRED PER SRM 53-20-3 FIG 5. TST: 53,245 HOURS. CYCLES: 32,117. (X)SDR AALA981557Stringer · crackedTUL - STR 15L CRACKED AT END TO FIRST FASTENER FORWARD 4 INCHES OF FS 720C. REPAIRED PER SRM 53-10-3 FIG 5. TST: 53,245 HOURS. CYCLES: 32,117. (X)SDR AALA981556Stringer · corrodedTUL - STR 27R CORRODED AT OUTBOARD END STA 1076. INSTALLED STRINGER REPAIR AT STA 1076 PER SRM 53-10-3 FIG 1. TST: 53,245 HOURS. CYCLES: 32,117. (X)SDR AALA981555Stringer · corrodedTUL - STR 27R CORRODED STA 720F + 4 INCHES TO STA 740. INSTALLED STRINGER SPLICE PER SRM 53-10-3 PG HB FIG 1. TST: 53,245 HOURS. CYCLES: 32,117. (X)SDR AALA981554Stringer · corrodedTUL - CORROSION ON STR 28R OUTBOARD SIDE STA 595. INSTALLED STRINGER SPLICE SECTION REPAIR PER SRM 53-10-3 FIG 1. TST: 53,245 HOURS. CYCLES: 32,117. (X)SDR AALA981553Stringer · corrodedTUL - STR 27R OUTBOARD LEG CORRODED AT STA 680. REMOVED STRINGER SECTION, SPLICED NEW SECTION PER SRM 53-10-3 FIG 1. TST: 53,245 HOURS. CYCLES: 32,117. (X)SDR AALA981552Floorbeam · corrodedTUL - CORROSION AT FLOORBEAM AT STA 344 FROM LBL 24 TO RBL 24. INSTALLED FLOORBEAM REPAIR PER ESO 11697 AT STA 344. ESO DATED 7-28-98. TST: 53,245 HOURS. CYCLES: 32,117. (X)SDR AALA981551Frame · crackedTUL - BELL FRAME CRACKED STA 380 BETWEEN STR'S 7-8, RT SIDE. REPAIRED FRAME PER SRM 53-10-4 FIG 2. TST: 53,245 HOURS. CYCLES: 32,117. (X)SDR AALA981550Frame · dentedTUL - BELT FRAME STA 580 UPPER LIP DENTED BETWEEN STR 24L AND STR 23L (DISTORTED WEB). REPAIRED PER SRM 53-10-4 FIG 1. TST: 53,245 HOURS. CYCLES: 32,117. (X)SDR AALA981549Frame · crackedTUL - BELT FRAME CRACKED 1 INCH LONG FROM RIVET TO STRINGER. CUT OUT RADIUS, STA 1180, STR 26R. INSTALLED REPAIR PER SRM 51-40-2 FIG 1 USING 7075T6 MATERIAL, .063 INCH THICKNESS WITH 2 ROWS FASTENERS, .1875 INCH HI-LOCKS, AROUND DAMAGE, .75 INCH SPACE BETWEESDR AALA981650Angle · corrodedTUL - AFT CARGO DOOR LOWER CUTOUT CHORD ANGLE CORRODED AT STATION 950E. REMOVED CORROSION, INSTALLED DOUBLER IAW ESO 11697, 8/13/98 AND SRM 51-40-4 PAGE 1 AND 2. (M)SDR AALA981611Angle · corrodedTUL - AFT CARGO DOOR LOWR CUTOUT CHORD ANGLE CORRODED AT STATION 990. REMOVED CORROSION, INSTALLED DOUBLER IAW ESO 11697, 2/13/98 AND SRM 51-40-4 PAGE 1 AND 2. (M)SDR GAIA98078Valve · leakingAFTER DEPARTING TOL, NR 3 STRUT OVERHEAT LIGHT ILLUMINATED AT 100 FT AGL, AND REMAINED ILLUMINATED UNTIL THRUST RETARDED BELOW 70 PERCENT N-1. AIRCRAFT RETURNED TO TOL AND MADE AN UNEVENTFUL LANDING. REMOVED AND REPLACED NR 3 ENGINE BLEED VALVE AND HIGH PRESSDR GAIA98077Seals · leakingDURING CLIMB-OUT FROM TOL TO TOL-BDL-EWR, THE NR 3 PYLON STRUT OVERHEAT LIGHT ILLUMINATED IN THE COCKPIT. THE CREW TURNED OFF THE BLEED AIR AND REDUCED THE POWER TO THE NR 3 ENGINES. THE CREW RETURNED TO TOLEDO AND MADE A ROUTINE LANDING. FOUND 8TH STAGE CHSDR EISA98203Bearing · failedON DEPARTURE, RETRACTING FLAPS FROM 2 DEGREES TO 0 DEGREES INBOARD FLAP GAUGE REMAINED AT 2 DEGREES. LEADING EDGE FLAPS INDICATOR LIGHTS DID NOT INDICATE AN AMBER LIGHT NOR DID FLIGHT ENGINEER PANEL SHOW (FLAP POSITION INDICATOR) LEADING EDGE FLAPS OR SLATS ESDR AALA981517Spar · crackedTUL - FOUND CRACK IN REAR SPAR OF NR 2 FUEL TANK CENTER SECTION AT RBL 20 INCH IN RADIUS OF WEB AT TOP CHORD ANGLE. INSTALLED REPAIR DOUBLER PER ESO 11697 DATED 8-6-98. (M)SDR AALA981516Stringer · corrodedTUL - FOUND STRINGER 30 CORRODED ON RT SIDE AFTER STATION 1148 TO 1160. REMOVED CORRODED AREA OF STRINGER 30. INSTALLED FILLER AND STRINGER SPLICE AT STRINGER 30, STA 1148 TO 1160 PER SRM 53-10-3 PAGE 4B. (M)SDR AALA981515Frame · crackedTUL - TOP OF FRAME AT STATION 1130 CRACKED AREA 27R. SCREW DRIVER TURN FRAME AT STATION 1130 STRINGER 27R. CUT OUT DAMAGED AREA IN UPPER FLANGE OF 1130 FRAME. FABRICATED REPAIR FILLER AND DOUBLER AND INSTALLED IAW SRM 51-40-3 2653538. PREPARED AND PLUGGED SDR GAIA9876Actuator · leakingBSM/MCI - EN ROUTE AFTER LEVEL CRUISE, A-SYSTEM HYDRAULICS WENT TO 1.5 GALLONS, THEN QUANTITY DECREASED TO ZERO, AND THE LOW LEVEL LIGHT ILLUMINATED. PERFORMED A-SYSTEM LOSS PROCEDURE, DECLARED EMERGENCY, AND DIVERTED TO DFW. THE AIRCRAFT LANDING IN DFW WITH
Back to Boeing 727-223