SDR ASAA2014022107255Transition Panel · corrodedAFT CARGO BAY RT FLOOR TRANSITION PANEL, BS 767-793 HAS MULTIPLE CORROSION SPOTS. ACFT GROUNDED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-60-53-1A1. REPLACED WITH NEW IAW SRM 51-40-02-0G.SDR ASAA2014022107254Floor Support · corrodedAFT CARGO BAY RBL 6, FLOOR SUPPORT FRAME HAS CORROSION IN FWD END. ACFT GROUNDED. REPAIRED AFT FLOOR SUPPORT IAW SRM 53-00-53-2R1.SDR ASAA2014022107235Shear Tie · crackedAFT CARGO BAY AT BS 927 AND S25R FWD STRINGER CLIP IS CRACKED. ACFT GROUNDED. R & R STRINGER CLIP AFT CARGO AT STA 927 S-25R IAW SRM 51-40-02-0G-0.SDR ASAA2014022107071Floor Support · corrodedDURING REMOVAL OF BS 500G BULKHEAD LOWER CENTER ANGLE FOUND FLOOR SUPPORT CORRODED AT RBL 13.8. ACFT GROUNDED. REMOVED CORROSION AND CHECKED LIMITS FOUND TO BE OUT OF LIMITS IAW SRM 53-30-53-1A1. REMOVED CORRODED SECTION OF SUPPORT, FABBED AND INSTALLED NESDR ASAA2014022007327Floor Support · corrodedFWD CARGO BAY AFT LT FLOOR SUPPORT FROM BS 380-500G SEVERAL SCREW HOLES CORRODED. ACFT GROUNDED. REPAIREDFLOOR SUPPORT IAW SRM 53-30-53-2R-3.SDR ASAA2014022007301Floor Support · corrodedFWD CARGO COMPARTMENT RT FLOOR SUPPORT FROM BS 380 TO 500D SEVERAL SCREW HOLES CORRODED. ACFT GROUNDED. R & R RT FLOOR SUPPORT IAW SRM 51-40-02-0G-0.SDR ASAA2014022007292Shear Tie · crackedRT FUSELAGE BS 360, BETWEEN S24-25R HAS FRAME SHEAR TIE IS CRACKED. ACFT GROUNDED. REPAIRED FRAME IAW SRM 53-00-07-2R-7.SDR ASAA2014022007233Crease Beam · corrodedCREASE BEAM INBD ANGLE AT BS 500C, LT OTBD HAS CORROSION. ACFT GROUNDED. REMOVED ANGLE, FABRICATED NEW, AND INSTALLED IAW SRM 51-40-02-0G-0 AND 51-40-05-0G-0.SDR ASAA2014022007097Stringer Clip · crackedLT FUSELAGE STA 500B, STRINGER S-16L CLIP IS CRACKED. ACFT GROUNDED. REMOVED STRINGER CLIP, LOCATED AND DRILLED NEW, INSTALLED STRINGER CLIP AT 500R STR 16L IAW
SRM 51-40-02-0G-0, STEP 4B.SDR ASAA2014022007056Angle · corrodedFLOOR SUPPORT ANGLE AT BS 535 LT OTBD HAS CORROSION. ACFT GROUNDED. REPAIRED FLOOR SUPPORT ANGLE IAW SRM 51-70-12-0G-0.SDR ASAA2014021907461Frame · crackedBS 348.2 FRAME LOWER ANGLE WAS FOUND CRACKED AT LWR FASTENER HOLE. ACFT GROUNDED. R & R FRAME IAW SRM 51-40-02-0G-0.SDR ASAA2014021907320Fitting · crackedRT FWD BOTTOM HORIZONTAL STABILIZER THRUST BEAM CORNER FITTING IS CRACKED. ACFT GROUNDED. FITTING REPLACED ON SB737-55-1091-400-2 IAW EA 400, 55EA, 12366.SDR ASAA2014021907229Support Frame · crackedUPON REMOVAL OF THE L1 MOP SILL THE BS 348.20 FRAME LOWER ANGLE WAS FOUND CRACKED AT LOWER FASTENER HOLE. ACFT GROUNDED. R & R FRAME ANGLE IAW SRM 51-40-02-0G-0.SDR ASAA2014021907215Channel · corrodedAFT WET AREA L2 DOOR MOP SILL CORRODED. ACFT GROUNDED.. REMOVED CORROSION, CHECKED OUT OF LIMITS IAW SRM 53 60-15-1A-1, FIG 101. R & R L2 DOOR MOP SILL IAW IAW SRM 51-40-02-0G-0, W 2", O .071, R .062, L 8FT, D .009.SDR ASAA2014021907191Sill · corrodedAFT WET AREA R2 DOOR MOP SILL CORRODED. ACFT GROUNDED. R & R R2 MOP SILL IAW SRM 51-40 02-0.SDR ASAA2014021707054Track · corrodedLT LATERAL TRACK AT BS 540 IS CORRODED. ACFT GROUNDED. R & R LATERAL TRACK IAW AMM 20-50-11-912-002.SDR ASAA2014021607450Skin · dentedLEFT OTBD FOREFLAP HAS A DENT & DELAMINATED AREA ON UPPER SIDE APPROXIMATELY 40" FROM INBD END. ACFT GROUNDED. REPAIRED LEFT OTBD FOREFLAP DENT & DELAMINATED AREA ON UPPER SIDE APPROXIMATELY 40" FROM INBD END IAW SRM 51-70-10, R & R.SDR ASAA2014021607390Skin · puncturedLEFT WING, NR 3 SPOILER LOWER SURFACE INBD OF ACTUATOR SKIN HAS A PUNCTURE AND PRODUCTION DOUBLER. ACFT GROUNDED. REPAIRED LT WING NR 3 SPOILER LOWER SURFACE IAW EA 400, 57EA, 12286.SDR ASAA2014021607358Rib · crackedRT HORIZONTAL STABILIZER L/E HAS A CRACKED RIB THIRD FROM INBD. ACFT GROUNDED. REPAIRED RIB IAW EA 400, 55 & EA 12393, REV.SDR ASAA2014021607294Skin · damagedLEFT WING NR 3 SPOILER LOWER SURFACE OTBD OF ACTUATOR SKIN HAS A CREASE. ACFT GROUNDED. REPAIRED LT WING NR 3 SPOILER LOWER SURFACE OTBD OF ACTUATOR IAW EA 400, 57EA 12286.SDR ASAA2014021606866Lens · brokenEXIT SIGN LIGHT LENS FROM FWD ENTRANCE IS BROKEN. ACFT GROUNDED. REPLACED LENS. OPS NORMAL.SDR ASAA2014021507008Skin · dentedLT WING INBD FLAP HAS DENT IN LOWER SECTION. ACFT GROUNDED. REPAIRED LT WING INBD FLAP DENT IN LOWER T/E SECTION OF FOREFLAP IAW SRM 51-70-2R-4, REPAIR 4.SDR ASAA2014021407120Shear Tie · corrodedAFT CARGO PIT SHEAR TIE AT BL0, BS 867 CORRODED. ACFT GROUNDED. SHEAR TIE REPAIR IAW SRM 53-00-07-2R-17, REPAIR 17.SDR ASAA2014021407095Shear Tie · corrodedSHEAR TIE, BL 0 CENTER AND RT IN AFT CARGO BAY CORRODED. ACFT GROUNDED. SHEAR TIE REPAIRED IAW SRM 53-00-07-2R-7, REPAIR 7 AND 53-00-07-2R-17, REPAIR 17 .SDR ASAA2014021407084Angle · corrodedAFT CARGO BAY LT BS 827-947, S25L, FLOOR TRANSITION ANGLE HAS NUMEROUS AREAS OF CORROSION. ACFT GROUNDED. REMOVED CORROSION AND CHECKED LIMITS, FOUND TO BE OUT OF LIMITS IAW SRM 53-60-53-1A-1. REMOVED, FABRICATED NEW AND INSTALLED NEW TRANSITION PANEL IAW SSDR ASAA2014021407072Floor Support · corrodedAFT CARGO BAY BS 907, S26R FLOOR SUPPORT CORRODED AT NUTPLATE. ACFT GROUNDED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-60-53-1A-1, FIG 101. REPAIRED SUPPORT IAW SRM 53-00-53-2R-2.SDR ASAA2014021307179Floorbeam · corrodedFLOORBEAM BS 947.5 RBL 12 AREA HAS CORROSION. ACFT GROUNDED. REPAIRED FLOORBEAM IAW EA 12265 REV.SDR ASAA2014021307121Attach Angle · corrodedAFT CARGO LT LOWER SIDEWALL LOWER ATTACHMENT LANDING CORRODED AROUND SCREW HOLES IN MULTIPLE AREAS FROM BS 727E-767. ACFT GROUNDED. REMOVED CORRODED AND CHECKED LIMITS FOUND TO BE OUT OF LIMITS IAW SRM 53-60-53-1A-1. REMOVED, FABRICATED NEW AND INSTALLED NESDR ASAA2014021307088Attach Angle · corrodedAFT CARGO, LT LOWER SIDEWALL, ATTACHMENT LANDING CORRODED AROUND SCREW HOLES IN MULTIPLE AREAS FROM FWD BULKHEAD OF AFT CARGO TO FRAME 727 F. ACFT GROUNDED. REMOVED CORROSION AND CHECKED LIMITS. FOUND TO BE OUT OF LIMITS IAW SRM 53-60-53-1A-1. REMOVED, FABRSDR ASAA2014021307085Attach Angle · corrodedAFT CARGO RT LOWER SIDEWALL LOWER ATTACHMENT LANDING CORRODED AROUND SCREW HOLES IN MULTIPLE AREAS FROM BS 727D-727 F. ACFT GROUNDED. REMOVED, FABRICATED AND INSTALLED NEW TRANSITION PANEL IAW SRM 51-40-02-0G-0, 51-40-05-0G-0-W.SDR ASAA2014021207228Stringer · crackedR1 DOOR STRINGER CRACKED AT FS 294.5 AND S14R. ACFT GROUNDED. R & R R1 DOOR STRINGER IAW SRM-51-40-02.SDR ASAA2014021207226Transition Panel · corrodedTRANSITION PANEL ON LT SIDE AT FS 500G IS CORRODED. ACFT GROUNDED. TRANSITION PANEL REMOVED, FABRICATED NEW AND INSTALLED IAW SRM 51-40-02.SDR ASAA2014021206974Stringer · crackedR2 DOOR STRINGER 11R CRACKED AT BS 294.5. ACFT GROUNDED. R & R R1 DOOR STRINGER ANGLE IAW SRM 51-40-02.SDR ASAA2014021206973Stringer · crackedR1 DOOR STRINGER CRACKED AT FS 294.5 AND S-14R. ACFT GROUNDED. R & R R1 DOOR STRINGER ANGLE AT FS 294.5 AND S-14R IAW SRM 51-40-02.SDR ASAA2014021206972Stringer · crackedR1 DOOR STRINGER CRACKED AT FS 294.5 AND S-13R. ACFT GROUNDED. R & R R1 DOOR STRINGER ANGLE AT FS 294.5 AND S-13R IAW SRM 51-40-02.SDR ASAA2014021206912Stringer · crackedR1 DOOR STRINGER 12R CRACKED AT BS 294.5. ACFT GROUNDED. R & R R1 DOOR STRINGER IAW SRM 51-40-02.SDR ASAA2014021206905Stringer · crackedR1 DOOR STRINGER CRACKED AT FS 294.5 AND S10R. ACFT GROUNDED. R & R STRINGER IAW SRM 51-40-02.SDR ASAA2014021107177Floor Panel · corrodedAFT CARGO BAY NR 5 FLOOR PANEL HAS MANY AREAS OF CORROSION ON LOWER SURFACE. ACFT GROUNDED. BLENDED CORROSION FOUND TO BE OUT OF LIMITS, FABRICATED NEW FLOOR PANEL IAW SRM 51-30-01, 51-40-05.SDR ASAA2014021107171Floorboard · corrodedAFT CARGO BAY NR 4 FLOORBOARD CORRODED AROUND HOLES. ACFT GROUNDED. FABRICATED, LOCATED AND DRILLED NEW FLOORBOARD IAW SRM 53-60-53-1A-1, FIG 1 AND SRM 51-40-05-0G-0.SDR ASAA2014021107170Floor Panel · corrodedFWD CARGO BAY NR 4 FLOOR PANEL HAS CORRODED ON LWR AFT SIDE. ACFT GROUNDED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-30-53-1A-1, FIG 101. FABRICATED NEW FLOOR PANEL IAW SRM 51-30-01-0G-0-W.SDR ASAA2014021107167Floor Panel · corrodedAFT CARGO BAY NR 1 FLOOR PANEL HAS CORROSION AROUND HOLES. ACFT GROUNDED. BLENDED CORRODED AREA FOUND TO BE OUT OF LIMITS. FABRICATED, LOCATED AND DRILLED NEW FLOOR PANEL IAW SRM 51-30-01-0G-0 AND SRM 53-60-53-1A-1.SDR ASAA2014021106966Floorbeam · crackedFLOORBEAM CRACKED IN TWO PLACES AT BS 540 BETWEEN BL 0.0 AND RBL 24.75. ACFT GROUNDED. R & R FLOORBEAM IAW SRM 51-40-02.SDR ASAA2014021106965Floorbeam · crackedFLOORBEAM CRACKED AT FS 540 AND RBL 24.75 - 45.50. ACFT GROUNDED. R & R FLOORBEAM ANGLE IAW SRM 51-40-02.SDR ASAA2014021106902Floor Support · corrodedFLOOR SUPPORT CORRODED AT FS 315, RBL 15. ACFT GROUNDED. R & R FLOOR SUPPORT IAW SRM 51-40-02-0G-0.SDR ASAA2014021007231Frame · crackedBS 500C FRAME IS CRACKED AT INBD HOLE OF THE AC BRACKET ATTACH POINT. ACFT GROUNDED. REPAIRED FRAME IAW T/C AD20062609 400-53-1-760.SDR ASAA2014021007178Attach Angle · crackedINTERCOSTAL ATTACH ANGLE IS CRACKED AT BS 360, S9L. ACFT GROUNDED. R & R ATTACH ANGLE IAW EA 400, 53EA 12281, REV. CAT B REPAIR IAW SRM 51-00-06.SDR ASAA2014021007069Sill · corrodedL1 DOOR MOP SILL CORRODED. ACFT GROUNDED. R & R L1 DOOR MOPSILL IAW SRM 51-40-02-0G-0, W 2", O .090, R .078, L 7FT, D .012.SDR ASAA2014021006964Gusset · crackedL1 DOOR FWD SIDE BS 312 AT STRINGER 14L GUSSET CRACKED. ACFT GROUNDED. R & R GUSSET IAW SRM 51-40-02-0G-0.SDR ASAA2014021006955Frame · crackedRIGHT FRAME IS CRACKED AT TWO HOLES OF THE BRACKET ATTACH POINT. ACFT GROUNDED. CUT OUT DAMAGE AREA, FABRICATED, LOCATED AND DRILLED AND INSTALLED TWO REPAIR ANGLES AT FRAME IAW T/C AD 20062609-400-53-1-760.SDR ASAA2014021006954Frame · crackedBS 500F FRAME IS CRACKED AT INBD HOLE OF THE BRACKET ATTACH POINT. ACFT GROUNDED. REPAIRED FRAME IAW AD 20062609 400-53-1-760.