SDR ASAA2014060808288Frame · crackedFRAME BS 500G CRACKED. ACFT GROUNDED. REPAIRED IAW SRM IAW SRM 53-00-07-22-13.SDR ASAA2014060808287Frame · crackedFRAME BS 520 RT SIDE HAS A CRACK. ACFT GROUNDED. REPAIRED IAW SRM IAW SRM 53-00-07-2G-13.SDR EB1R201405140001Skin · corrodedFOUND CORROSION ON THE UPPER AFT SURFACE OF THE LT WING SKIN AT WBL 93.0-WBL 99.0 AT REAR SPAR, AND WBL 135.0 AT REAR SPAR, AND WBL 130.0- WBL 134.0 AT S-13. CLEAN CORROSION AND REPAIRED AREAS IAW MFG MESSAGE CIN-CIN-14-0007-11B AND SRM 57-20-01.SDR ASAA2014042707589Lamp · failedINTERIOR EMERGENCY LIGHTS FOUND ABOVE SEAT 9DEF TO BE INOPERATIVE. ACFT GROUNDED. R & R EMERGENCY AISLE LIGHT LAMP AT 9 DEF, OPS CHECKED GOOD IAW AMM 33-51-21-962-001.SDR ASAA2014041107468Skin · crackedFOUND A CRACK ON RT LOWER SKIN AT AFT SPAR AT SS 150.0. ACFT GROUNDED. REPAIR ACCOMPLISHED IAW EA 400-55EA-12482, REV NEW.SDR ASAA2014041107466Skin · crackedSKIN CRACKED AT LOWER SIDE OF RT STAB AT AFT SPAR AT APPROXIMATELY STABILIZER STA 129.0. ACFT GROUNDED. VERIFIED CRACK HFEC IAW BNDT 51-00.00 PART 6, FIG 23, 16050. REPAIR ACCOMPLISHED REF EA 400-55EA-12482, REV NEW.SDR ASAA2014041007507Skin · crackedFOUND FUSELAGE SKIN CRACKED FWD OF L2 DOOR AT LOWER CORNER FUSELAGE BS 950 AT S17L. ACFT GROUNDED. REPAIRED SKIN IAW SRM 53-00-1-2R-32, DETAIL IV.SDR ASAA2014040907504Door · out of adjustL1 DOOR DIFFICULT TO CLOSE. ACFT GROUNDED. PERFORMED FWD ENTRY DOOR TEST REF TASK 52-11-00-75-051 DOES NOT PASS TORQE TEST. L1 DOOR WAS ADJUSTED. INSTALLED DOOR LINER AND HANDLE AND L1 SLIDE REF MM 25-61-35-402-003 AND MM 52-11-31-409-009. HANDLE TORQUED SDR ASAA2014040707473Seal · out of positionL1 DOOR IS BINDING AND HARD TO CLOSE. ACFT GROUNDED. REPOSITIONED L1 DOOR BULB SEAL, NO BINDING NOTED AFTER SEAL REPOSITION IAW 52-11-31.SDR ASAA2014040407445Wire · burnedNOTICED TOXIC ELECTRICAL BURNING ODOR ON CAPTAINS SIDE OF COCKPIT. ACFT GROUNDED. INSPECT P18 PANEL FOUND T BLOCK 214G WITH DAMAGED WIRE TERMINAL. REMOVED 3 EA WIRES AT TERMINAL 5. WIRE NR`S W276-038, W018-306-10, W018-890-14 REF WIRE DIAGRAM 24-52-21. R & R SDR ASAA2014040307431Skin · crackedR2 DOOR LOWER CUT OUT SKIN IS CRACKED. ACFT GROUNDED. REPAIRED SKIN IAW SRM 53-00-01-2R-32.SDR ASAA2014033107427Frame · corrodedAFT CARGO BAY FRAME BS 807 BETWEEN S27R-27L CORRODED. ACFT GROUNDED. REPAIRED FRAME IAW SRM 53-00-07-2R-17.SDR ASAA2014033107426Frame · corrodedAFT CARGO FRAME, BS 927, S25-26L CORRODED. ACFT GROUNDED. REPAIRED FRAME IAW SRM 53-00-07-2R-8.SDR ASAA2014033007457Cargo Track · crackedWHILE PREPPING FOR CIC APPLICATION, FOUND AFT CARGO TRACK, RBL 13.8 CRACKED AT BS 727G. ACFT GROUNDED. REPAIRED CARGO TRACK IAW SRM IAW SRM 53-00-53-2R-2.SDR ASAA2014032907388Cargo Track · corrodedRIGHT CARGO TRACK CORRODED AT CARGO DOOR OPENING, AFT. ACFT GROUNDED. CARGO TRACK REMOVED IAW SRM 51-40-02. INSTALLED NEW CARGO TRACK AND 2 SPLICES IAW SRM 51-40-02.SDR ASAA2014032707389Floor Support · corrodedAFT CARGO BAY FLOOR SUPPORT, BS 747+4.5 CORRODED ON LOWER SURFACE, LBL 8.10. ACFT GROUNDED. REMOVED CORRODED SECTION AND INSTALLED NEW FLOOR SUPPORT IAW SRM 53-00-53-2R-2, REPAIR 2.SDR ASAA2014032707360Stringer Clip · crackedIN FWD CARGO BAY STRINGER CLIP 25R BS 500C IS CRACKED, ACFT GROUNDED. R & R STRINGER CLIP IAW SRM 51-40-02-0G-0.SDR ASAA2014032707359Stringer Clip · crackedIN CARGO BAY STRINGER CLIP 25R BS 500E IS CRACKED, ACFT GROUNDED. R & R STRINGER CLIP IAW SRM 51-40-02-0G-0.SDR ASAA2014032707330Floorbeam · corrodedAFT CARGO FLOOR SUPPORT, BS 747, LBL 12.5 CORRODED AT SPLICE. ACFT GROUNDED. FABRICATED NEW PARTS IAW SRM 51-40-02. INSTALLED REPAIR IAW SRM 53-00-53-2R-2, REPAIR 2.SDR ASAA2014031907459Shear Tie · crackedFWD CARGO BAY FRAME BS 500F SHEAR TIE IS CRACKED BETWEEN STRINGERS 25-2LL. ACFT GROUNDED. REPAIRED SHEAR TIE IAW EA 400-53EA-12411, REV NEW.SDR ASAA2014031907252Pin · out of adjustFORWARD ENTRY DOOR IS INCREASINGLY HARDER TO CLOSE AND LATCH. ACFT GROUNDED. INSPECTED THE L1 DOOR, FOUND THE GUIDE PIN HITTING THE GUIDE, ADJUSTED PIN IAW AMM 52-11-00-705-007, LUBED THE GUIDE ARM ASSY, CHECKED PIN CLEARANCES AND FIT OF DOOR. DOOR OPS CHECKSDR ASAA2014031307227Floor Panel · crackedDENT FOUND IN FWD CARGO BAY FLOOR PANEL AT APPROXIMATELY FS 500 WITH SMALL CRACK APPROX 1 INCH IN LENGTH. ACFT GROUNDED. FABRICATED NEW FLOOR PANEL IAW SRM 51-40-05-0G-0 AND 53-30-53-01-1.SDR ASAA2014031007319Failsafe · crackedFAILSAFE AT RT BS 480 IS CRACKED IN RADIUS JUST BELOW CABIN FLOOR LEVEL. ACFT GROUNDED. FABRICATED, LOCATED AND DRILLED NEW FAILSAFE IAW SRM 51-40-05-0G-0. R & R NEW FAILSAFE IAW SRM 51-40-02-0G-0.SDR ASAA2014030607458Shear Tie · crackedBS 500F, FRAME SHEAR TIE IS CRACKED BETWEEN STRINGERS 25&26R. FOUND DURING DISPLACEMENT OF FRAME. ACFT GROUNDED. REPAIRED SHEAR TIE IAW EA 400, 53EA 124113 REV.SDR ASAA2014030307076Skin · crackedRT HORIZONTAL STABILIZER BOTTOM SKIN CRACKED ON REAR SPAR 5 FT FROM INBD ROOT. ACFT GROUNDED. REPAIRED SKIN IAW SRM 55-10-01-2R-13.SDR ASAA2014022606996Frame · crackedFRAME BS 500F RT SIDE IS CRACKED AT 1 INCH WIRE PENETRATION HOLE EXTENDING INBD FROM EDGE OF HOLE APPROX .75" IN THE FWD CARGO BAY. ACFT GROUNDED. REPAIRED CRACKED FRAME IAW SRM 53-00-07-2R-13.SDR ASAA2014022507232Stringer · corrodedBS 1088 BULKHEAD APU AIR INLET CUTOUT UPPER STRINGER IS CORRODED. ACFT GROUNDED. R & R STRINGER IAW SRM 51-40-02.SDR ASAA2014022507218Stiffener · corrodedBS 1088, BULKHEAD APU AIR INLET CUTOUT RT VERTICAL STIFFENER IS CORRODED. ACFT GROUNDED. R & R RT VERTICAL STIFFENER IAW SRM 51-40-02-0.SDR ASAA2014022507217Stiffener · corrodedSTA 1088, BULKHEAD APU AIR INLET CUTOUT LT VERTICAL STIFFENER IS CORRODED. ACFT GROUNDED. R & R VERTICAL STIFFENER, STA 1088 BULKHEAD LT SDIE OF APU AIR INLET CUTOUT IAW SRM 51-40-02-0G-0.SDR ASAA2014022507216Support Angle · corrodedBS 1088, BULKHEAD APU AIR INLET CUTOUT LOWER TORQUE BOX LINER DRAIN SUPPORT ANGLE IS CORRODED. ACFT GROUNDED. REPLACED SUPPORT ANGLE IAW SRM 51-40-02-0G-0.SDR ASAA2014022507086Stiffener · corrodedAPU BAY INLET CUTOUT AFT OTBD ANGLE CORRODED FOUND DURING AFT STRAP REPAIR. ACFT GROUNDED. APU BAY INLET CUTOUT AFT OTBD ANGLE REMOVED. FABRICATED NEW AND INSTALLED IAW SRM 51-40-02-0G-0 AND 51-40-05-0G, 0 W, .6 O, .06 R, 0 L ,1" D .06.SDR ASAA2014022407096Stringer · corrodedAPU INLET CUTOUT IN APU COMPARTMENT UPPER STRINGER IS CORRODED. ACFT GROUNDED. R & R UPPER STRINGER IAW SRM 51-40-02-0G-0.SDR ASAA2014022407302Stringer · corrodedAPU INLET CUTOUT IN APU BAY STRINGER IS CORRODED. ACFT GROUNDED. R & R STRINGER IAW SRM 51-40-02-0G-0.SDR ASAA2014022407153Stringer · corrodedAPU INLET DUCT CUTOUT LOWER STRINGER CORRODED. ACFT GROUNDED. R & R STRINGER IAW SRM 51-40-02-0G-0.SDR ASAA2014022407152Channel · crackedFWD CARGO BAY CENTER CHANNEL BS 500A FOR VHF NR 1 ANTENNA IS CRACKED. ACFT GROUNDED. REMOVED, FABRICATED NEW AND INSTALLED NEW CHANNEL IAW SRM 51-40-02-0G-0.SDR ASAA2014022407119Attach Bracket · crackedFWD CARGO BAY CENTER CHANNEL FOR NR 1 VHF ANTENNA STA 500A AFT ATTACH BRACKET IS CRACKED. ACFT GROUNDED. REMOVED ATTACH BRACKET FOR NR 1 VHF ANTENNA SUPPORT CHANNEL FABRICATED AND INSTALLED NEW BRACK IAW DWG 65-45783 AND SRM 51-40-02-0G-0.SDR ASAA2014022407055Stiffener · corrodedAPU INLET CUTOUT IN APU COMPARTMENT FWD STIFFENER IS CORRODED. ACFT GROUNDED. R & R FWD STIFFENER IAW SRM 51-40-02-0G-0.SDR ASAA2014022407053Stiffener · corrodedAPU INLET CUTOUT IN APU COMPARTMENT AFT STIFFENER IS CORRODED. ACFT GROUNDED. R & R AFT STIFFENER IAW SRM 51-40-02-0G-0, W 1", O .060", R .052", L 1", D .008".SDR ASAA2014022307328Floor Support · corrodedAFT CARGO FLOOR SUPPORT RBL 8 IS CORRODED AROUND NUTPLATES BS 787-847. ACFT GROUNDED. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. REPAIRED AREA IAW SRM 53-00-53-2R-1 REPAIR 1, FIG 101.SDR ASAA2014022307298Cargo Track · corrodedAFT CARGO TRACK LBL 3 IS CORRODED AROUND NUTPLATES, BS 787-847. ACFT GROUNDED. REPAIRED CARGO TRACK IAW SRM 55-00-53-2R-1.SDR ASAA2014022207429Skin · crackedFUSELAGE SKIN HAS CRACK INDICATION FWD OF BS 500F, JUST BELOW S10R, IN CABIN. ACFT GROUNDED. REPAIRED SKIN IAW EA AD20130901-400-53-101.SDR ASAA2014022207190Skin · crackedFUSELAGE SKIN HAS TWO MFEC CRACK INDICATIONS, UNDER BS 520, BELOW S14L. ACFT GROUNDED. REPAIRED SKIN IAW SRM 53-00-01-2R-30.SDR ASAA2014022207118Stringer Clip · crackedCRACKED STRINGER CLIP AT STR4L BS 727E. ACFT GROUNDED. R & R NEW STRINGER CLIP IAW SRM 51-40-02-0G-0.SDR ASAA2014022207117Cusp Web · crackedPASSENGER-CARGO FWD CABIN AREA AT FRAME BS 500 ON LT CUSP WEB FWD OTBD CORNER IS CRACKED. ACFT GROUNDED. R & R LT CUSP WEB IAW SRM 51-40-020-0G-0.SDR ASAA2014022107368Stringer · corrodedFWD CARGO BAY AFTER S27R AND BS 500G, STRINGER CORRODED. ACFT GROUNDED. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-03-1A-1. REPAIRED IAW SRM IAW SRM 53-0-03-2R-1, REPAIR 1.SDR ASAA2014022107317Floor Support · corrodedAFT CARGO BAY RT FLOOR SUPPORT FROM BS 727-767 HAS MULTIPLE CORRODED AREAS. ACFT GROUNDED. R & R FLOOR SUPPORT IAW SRM 51-40-02-0G-0.SDR ASAA2014022107314Floor Panel · corrodedAFT CARGO BAY LT FLOOR PANEL FROM BS 727 - 947 HAS MULTIPLE CORRODED AREAS. ACFT GROUNDED. R & R FLOOR PANEL IAW SRM 51-40-02-0G-0.SDR ASAA2014022107313Floor Support · corrodedAFT CARGO BAY FROM BS 787 - 947.5 RT FLOOR SUPPORT CORRODED. ACFT GROUNDED. R & R FLOOR SUPPORT IAW SRM 51-40-02-0G-0.SDR ASAA2014022107299Frame · corrodedAFT CARGO COMPARTMENT BS 807, INBD S27L, CORROSION EXIST ON FWD SIDE OF FRAME. ACFT GROUNDED. REMOVED DOUBLER FABRICATED NEW AND INSTALLED DOUBLER IAW SRM 51-40-07-0G-0 AND 53-00-07-2R-8, REPAIR 8.SDR ASAA2014022107293Floor Support · corrodedAFT CARGO COMPARTMENT, RBL 20, FLOOR CAP STRIP STA 773-860 HAS MULTIPLE CORROSION SPOTS ON UPPER SIDE. ACFT GROUNDED. REMOVED CORRODED FLOOR CAP STRIP. FOUND TO BE OUT OF LIMITS IAW SRM 53-60-15-1A-1. REPLACED NEW FLOOR CAPSTRIP IAW SRM 51-40-02-0G-0.
Back to Boeing 737-4Q8